- All
- Favorite
- Popular
- Most rated
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | SR11 |
| Output Signal | 0–2.5 V DC (with integrated amplifier) |
| Sensitivity | 15 µV/(W/m²) |
| Spectral Range | 305–2800 nm |
| Max. Irradiance | 2000 W/m² |
| Temp. Coefficient of Sensitivity | ±0.1 %/°C |
| Operating Temperature | −40 °C to +80 °C |
| Long-term Instability (per year) | < ±1 % |
| Non-linearity (0–1000 W/m²) | < ±2.5 % |
| Tilt Response (at 1000 W/m²) | < ±3 % |
| Compliance | ISO 9060:2018 Class A, ISO 9847 |
| Dimensions (incl. mounting mast) | 420 × 355 × 150 mm (L × W × H) |
| Weight | 2.6 kg |
| Cable | 3 m shielded cable with PENTAX 7-pin connector |
| Compatible RTUs | A723, A733, A75x series |
| Brand | ADCON |
|---|---|
| Model | Hydra Probe II |
| Measurement Parameters | Volumetric Water Content (VWC), Soil Temperature, Electrical Conductivity (EC) |
| Dielectric Constant Range | 1–65 (±1.5% or ±0.2, whichever is greater) |
| VWC Accuracy | ±0.03 m³/m³ (typical mineral soils) |
| EC Range | 0–20 dS/m |
| EC Accuracy | ±2% or ±0.002 dS/m (whichever is greater) |
| Temperature Range | −10°C to +65°C |
| Temp Accuracy | ±0.6°C |
| Probe Dimensions | Ø3.0 cm × 5.7 cm |
| Encapsulated Body | Ø4.2 cm × 12.4 cm |
| Weight | 200 g (probe only) |
| Output | SDI-12 digital interface |
| Power Supply | 6–30 VDC, typical current draw ≤20 mA |
| IP Rating | IP68 (continuous submersion rated) |
| Calibration | Factory-calibrated |
| Brand | ADCON |
|---|---|
| Origin | Switzerland |
| Model | LVE1 |
| Pressure Ranges | 1, 3, 10 bar |
| Overpressure Limits | 3, 7, 20 bar |
| Output Signal | 0.1–2.5 V DC |
| Supply Voltage | 3.2–12 V DC |
| Accuracy (0–40°C) | ±0.1% FS |
| Resolution | < 0.01% FS |
| Long-term Stability | ≤1 mbar (for ranges < 2 bar), ≤0.1% FS (for ranges ≥ 2 bar) |
| Operating Temperature | −40°C to +80°C |
| Temp. Compensation Range | 0°C to +80°C |
| Probe Dimensions | Ø22 mm × 95 mm |
| Cable | Ventilated PE, standard 15 m (custom lengths available) |
| Connector | Binder 7-pin M9 male |
| IP Rating | IP68 (probe), IP67 (connector) |
| Wetted Materials | 316L stainless steel (DIN 1.4435), FKM fluorocarbon elastomer, polyethylene |
| Media Compatibility | Water, wastewater, groundwater, non-corrosive aqueous solutions |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Wet |
| Power Supply | 5.5–12 VDC |
| Output Signal | 0–2.5 VDC |
| Dimensions | 45 × 90 × 90 mm |
| Weight | 500 g |
| IP Rating | IP66 |
| Operating Temperature | −20 to +60 °C |
| Relative Humidity Range | 0–100 %RH |
| Sensing Principle | Capacitive Condensation |
| Repeatability | ±3 % |
| Housing Material | PTFE-coated ceramic sensor element |
| Cable | 3 m, 7-pin waterproof PENTAX connector |
| Mounting | Integrated mast clamp for Ø40–50 mm poles |
| Part Number | 200.733.060 |
| Brand | ADCON |
|---|---|
| Origin | Imported (Netherlands/Germany) |
| Manufacturer Type | Authorized Distributor |
| Model | CMP-3 |
| Compliance | ISO 9060:2018 Class C (Secondary Standard) |
| Spectral Range | 310–2800 nm |
| Sensitivity | 5–20 µV/W·m⁻² |
| Max Irradiance | 2000 W/m² |
| Temperature Coefficient of Sensitivity | ±5% (−10 °C to +40 °C) |
| Operating Temperature | −40 °C to +80 °C |
| Long-term Stability | ±1% per year |
| Non-linearity (0–1000 W/m²) | ±2.5% |
| Tilt Response (at 1000 W/m²) | ±3% |
| Output Signal | 0–2.5 V DC (integrated Adcon signal conditioner) |
| Cable | 2 m shielded cable with PENTAX 7-pin connector |
| Mounting | Pole-mount compatible with dual pipe clamps |
| Brand | Adcon |
|---|---|
| Origin | Imported |
| Model | TR1 |
| Power Supply Voltage | 5.5–15 VDC |
| Current Consumption | <1.5 mA typical |
| Operating Temperature Range | −40 °C to +60 °C |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±2 %RH (0–90 %RH at +20 °C), ±3 %RH (90–100 %RH at +20 °C) |
| RH Long-Term Stability | <1 %RH/year |
| RH Temperature Coefficient | ±0.03 %RH/°C |
| Temperature Accuracy | ±0.2 °C at +20 °C |
| Temperature Sensor | Pt1000 (DIN Class A) |
| Output Signal | 0–2.5 VDC (dual-channel, independent for T & RH) |
| Enclosure Material | Tecapet® |
| Ingress Protection | IP65 |
| Dimensions | Ø12 mm × 101 mm |
| Weight | 13 g |
| Connector | 8-pin M12 male |
| Filter Cap | Stainless steel mesh cap (sintered metal cap optional) |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | SP-lite |
| Pricing | Available Upon Request |
| Brand | ADCON |
|---|---|
| Origin | Switzerland |
| Model | BP1 |
| Measurement Range | 500–1500 mbar |
| Accuracy | ±0.1% FS (0–80°C) |
| Output Signal | 0.1–2.5 VDC |
| Linearity | ±0.025% FS |
| Long-term Stability | ≤1 mbar (for ranges ≤1 mbar) |
| Operating Temperature | −20°C to +80°C |
| Enclosure Material | Polycarbonate |
| Sensor Element Material | 316L Stainless Steel (DIN 1.4435) |
| Cable | 3 m PE-shielded, with PENTAX 7-pin waterproof connector |
| IP Rating | IP67 (sensor: IP68) |
| Supply Voltage | 3.5–12 VDC @ <3 mA |
| Shock Resistance | 20 g (11 ms) |
| Vibration Resistance | 20 g (5–2000 Hz, ±3 mm amplitude) |
| Pressure Cycle Endurance | 10 million cycles at 0–100% FS (25°C) |
| Housing Dimensions (incl. mounting bracket, vent, cable gland) | 145 × 90 × 70 mm |
| Sensor Dimensions | Ø21 × 121 mm |
| Weight (incl. 3 m cable) | 500 g |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Application | Drip Irrigation System Efficiency Monitoring |
| Resolution | 1 mm (rainfall mode) / 5 g per tip (irrigation mode) |
| Collection Orifice Area | 50 cm² |
| Tip Volume | 5 g |
| Operating Temperature Range | −30 °C to +70 °C |
| Weight | 0.4 kg |
| Housing Material | Styrosun® |
| Cable | 5 m shielded cable with PENTAX 7-pin connector |
| Compatible RTUs | A723, A733, A753 series |
| Mounting | Pole-mounted with two pipe clamps |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | LP-02 |
| Calibration Standard | ISO 9060:2018 Class C (Secondary Standard) & WMO Guide (2018) |
| Spectral Range | 305–2800 nm |
| Sensitivity | 15 µV/(W·m⁻²) |
| Max Irradiance | 2000 W·m⁻² |
| Temp. Coefficient of Sensitivity | ±0.1 %/°C |
| Operating Temperature | −40 °C to +80 °C |
| Long-Term Stability (per year) | ±1 % |
| Non-Linearity (0–1000 W·m⁻²) | ±2.5 % |
| Tilt Response (at 1000 W·m⁻²) | ±3 % |
| Output Options | 0–2.5 V analog (with integrated Adcon amplifier) or mV-level thermopile signal (no amplifier) |
| Cable | 3 m shielded cable with PENTAX 7-pin connector |
| Mounting | Rigid pole-mount bracket |
| Dimensions (w/ bracket) | 420 × 355 × 150 mm (L×W×H) |
| Weight | 2.15 kg |
| Compliance | ISO 9060:2018, WMO No. 8, ASTM E824-94 |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | ST |
| Measurement Range | -20°C to +40°C |
| Accuracy | ±0.3°C |
| Sensor Element | Pt100 Class B |
| Output Signal | 0–2.5 V |
| Supply Voltage | 5.5–8 V DC |
| Probe Length | 30 cm (12 in) |
| Total Length | 45 cm (17.7 in) |
| Cable Length | 5 m (shielded, PUR jacket |
| Enclosure Material | Stainless Steel |
| Ingress Protection | IP67 |
| Connector | 7-pin male plug |
| Max Custom Depth | 100 cm (39.4 in) |
| Ordering Code | 200.733.040 |
| Brand | ADCON |
|---|---|
| Origin | Germany (Manufactured for HACH) |
| Model | Pro |
| Wind Speed Range | 0.4–270 km/h |
| Startup Wind Speed | <0.4 m/s |
| Wind Speed Sensor | Three-cup aluminum rotor with low-friction bearings |
| Wind Direction Sensor | Precision Hall-effect transducer with aluminum/stainless-steel vane |
| Housing Material | Anodized aluminum, seawater-corrosion resistant |
| Mounting | 80 cm mast arm with universal bracket |
| Cable Configuration | Integrated PENTAX connector + Y-split cable (dual-sensor interface to single ADCON RTU port) |
| Compliance | WMO-recommended installation geometry and performance criteria |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | SM1 |
| Communication Protocol | SDI-12 |
| Outer Tube Diameter | Φ32 mm |
| Top Cap Diameter | Φ82 mm |
| IP Rating | IP67 |
| Operating Voltage | 5.6–12 VDC |
| Soil Moisture Range | 0–100% vol |
| Moisture Resolution | 0.1% vol |
| Moisture Accuracy | ±2% vol |
| Measurement Principle | Capacitive Dielectric Sensing |
| Temperature Range (Soil) | –55 to +70 °C |
| Temp Resolution | 0.125 °C |
| Temp Accuracy | ±0.5 °C (0–70 °C) |
| Temp Sensor Count | Up to 5 |
| Temp Sensor Spacing | 30 cm (positions at 15, 45, 75, 105, 135 cm) |
| Moisture Sensor Spacing | 10 cm |
| Sensor Length Options | 30, 60, 90, 120, 150 cm |
| Cable | 5 m, 7-pin waterproof Pico-BNC (Pentax) connector |
| Housing Material | UV-stabilized, shrink-resistant PVC |
| Mounting Options | Direct insertion (slurry) or conduit-based installation |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | PQS1 |
| Spectral Range | 400–700 nm ±4 nm |
| Sensitivity | 10–50 µV/µmol·m⁻²·s⁻¹ |
| Output Signal | 0–2.5 V (standard Adcon analog, with integrated amplifier) |
| Cable Length | 5 m (optional 15 m) |
| Response Time | <1 µs |
| Long-Term Drift | <2% per year |
| Nonlinearity (0–10,000 µmol·m⁻²·s⁻¹) | <1% |
| Cosine Response Error (up to 80° incidence at 1000 µmol·m⁻²·s⁻¹) | <30 µmol·m⁻²·s⁻¹ |
| Temperature Coefficient | −0.12%/°C |
| Field of View | 180° |
| Leveling Accuracy (integrated bubble vial) | ±0.2° |
| Detector Type | Silicon photodiode |
| Operating Temperature | −30°C to +70°C |
| Storage Temperature | −30°C to +70°C |
| Humidity Tolerance | 0–100% RH (non-condensing) |
| Ingress Protection | IP67 |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Model | A512 |
| Measurement Principle | Resistive Soil Water Potential (Tensiometric Equivalent) |
| Max. Sensors Supported | 3 × Standard ADCON Model 200 Sensors |
| Output Signal | 0–2.5 V analog |
| Input Range | 0–200 cBar |
| Accuracy | ±5% of full scale |
| Enclosure Material | Anodized aluminum |
| IP Rating | IP67 |
| Dimensions (L×W×H) | 100 × 110 × 50 mm (incl. cable glands & mounting bracket) |
| Cable | 3 m, 7-pin PENTAX 53 waterproof connector |
| Compatible RTUs | A720, A723, A732, A733 |
| Sensor Housing | Stainless steel with patented dual concentric electrode geometry embedded in hydrophilic matrix |
| Operating Temperature | –20 °C to +60 °C |
| Long-term Stability | Non-dissolving, freeze-thaw resistant, no gypsum degradation |
| Mounting Flexibility | Single-depth multi-sensor or multi-depth profiling configuration |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | SEN-R |
| Price | Upon Request |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | RG1 |
| Resolution | 0.1 mm (400 cm² collector) / 0.2 mm (200 cm² collector) |
| Collection Area | 200 cm² or 400 cm² |
| Accuracy | ±2% up to 60 mm/h |
| Output | Reed switch pulse (dry contact, hermetically sealed, Meder Germany, >1 million actuations) |
| Operating Temperature | 0 °C to +75 °C |
| Weight | 0.5 kg |
| Housing Material | Anodized aluminum |
| Cable | 1 m PUR shielded cable with PENTAX 7-pin M9 male connector |
| Compliance | Compatible with ADCON A723/A733/A753 RTUs |
| Mounting | Pole- or surface-mountable |
| Heating | Not integrated |
| Key | Brand: ADCON |
|---|---|
| Origin | Imported |
| Device Type | Cloud-Connected Wireless Data Acquisition & Management Platform |
| Communication | Dual-Mode RF + GPRS/UMTS |
| Enclosure Rating | IP67 |
| Operating System | Embedded Linux |
| Software Version | AddVANTAGE Pro v6.4 |
| Database Backend | Oracle |
| Deployment Model | Web-Based SaaS Architecture |
| Compliance | WMO Certified Sensor Interface |
Show next