BrandLufft
OriginGermany
ModelWS100-UMB
Measurement Principle24 GHz Doppler radar-based particle detection
Power SupplyDC 12–36 V (solar-compatible)
Operating Temperature−40 °C to +70 °C
Heating FunctionIntegrated radar dome heater
Communication ProtocolsModbus RTU, SDI-12, CAN, ASCII, MQTT (optional)
IP RatingIP66
MaintenanceNo moving parts, maintenance-free design
ComplianceCE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/6-4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
OriginGermany
ModelWS500-UMB
Measurement PrinciplesUltrasonic (wind speed & direction), NTC thermistor (temperature), Capacitive polymer (relative humidity), MEMS capacitive (barometric pressure)
Wind Speed Range0–60 m/s
Wind Speed Accuracy±0.3 m/s or ±3% (0–35 m/s)
Wind Direction Range0–359.9°
Wind Direction Accuracy±3°
Temperature Range−50 to +60 °C
Temperature Accuracy±0.2 °C (−20 to +50 °C), ±0.5 °C (outside range)
Relative Humidity Range0–100 %RH
RH Accuracy±2 %RH
Barometric Pressure Range300–1200 hPa
Pressure Accuracy±1.5 hPa
Power Supply24 VDC ±10%, <4 VA (unheated), 10 W max with heater
Output InterfaceRS-485, 2-wire, half-duplex
Operating Temperature−50 to +60 °C
Enclosure MaterialAnodized aluminum
Weight1.3 kg
Dimensions (H × Ø)290 mm × 150 mm
ColorWhite powder-coated finish
ProtocolLufft UMB protocol (binary/ASCII over RS-485)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOTT Hydromet
OriginGermany
ModelOTT Qliner2
Velocity Range±10 m/s
Velocity Accuracy±1% of reading or ±0.5 cm/s
Sampling Rateup to 1 Hz
Beam Frequency1 MHz / 2 MHz
Depth Range20 m (1 MHz) / 10 m (2 MHz)
Cell Size0.3–4 m (1 MHz) / 0.1–2 m (2 MHz)
Minimum Blanking Distance0.2 m (1 MHz) / 0.05 m (2 MHz)
Max. Number of Cells40
Temperature Range–4 °C to 40 °C
Temp. Accuracy/Resolution±0.1 °C / 0.01 °C
Operating Temp.–5 °C to 40 °C
Storage Temp.–20 °C to 45 °C
Ingress ProtectionIP68
Shock ResistanceIEC 721-3-2
Vessel Dimensions940 × 470 × 223 mm
Weight11 kg (including sensor and battery)
PowerRechargeable 12 V DC battery, ~24 h operation
Wireless InterfaceBluetooth 2.4 GHz, up to 150 m range
PDA OSWindows Mobile with localized Chinese GUI
PC SoftwareData visualization, ASCII export, profile replay, and QA/QC post-processing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOTT Hydromet
OriginImported
ModelOTT CBS
Measurement Range0–15 m / 0–30 m (selectable)
Accuracy±5 mm (standard), ±1.5 mm (USGS-compliant, within first 3 m of 15 m range)
Resolution1 mm / 0.1 mbar
OutputSDI-12, 4–20 mA (0.1% accuracy, 15-bit)
Power Supply10–30 V DC (typically 12 V or 24 V)
Power Consumption320 mAh/day (1-min interval), 25 mAh/day (15-min interval)
Operating Temperature–20 to +60 °C
Storage Temperature–40 to +85 °C
EnclosureIP43-rated CBS engineering plastic
Dimensions165 × 205 × 115 mm
Weight1500 g
EMC ComplianceIEC 61326 / EN 61326
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
OriginGermany
ModelVENTUS-X-UMB
Heating FunctionIntegrated PTC-based anti-icing system
Measurement PrincipleTime-of-flight ultrasonic anemometry
Output ProtocolsSDI-12, Modbus RTU, ASCII, CAN bus (configurable)
Environmental CertificationIP66, EN 60950-1, EN 61000-6-2/-6-3, IEC 60068-2-30 (damp heat), IEC 60068-2-14 (thermal cycling), IEC 60068-2-6 (vibration), IEC 60068-2-52 (salt mist), IEC 60068-2-31 (ice accretion test)
Operating Temperature Range–40 °C to +70 °C (with active heating)
Wind Speed Range0–60 m/s
Wind Direction Range0–360°
Resolution0.1 m/s (wind speed), 1° (wind direction)
Accuracy±0.2 m/s (wind speed), ±2° (wind direction)
Power Supply12–30 V DC
Power Consumption<1.5 W (standby), <4.5 W (heating active)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginImported
ModelPQS1
Output Signal0–2.5 V analog (with integrated amplifier)
Cable LengthStandard 5 m (optional 15 m)
Spectral Range400–700 nm (McCree-defined PAR)
Cosine Response Error< ±3% at 75° zenith angle
Operating Temperature–40 °C to +70 °C
IP RatingIP68
Housing MaterialAnodized aluminum with quartz diffuser
ComplianceISO 9047, ASTM E2847, WMO Guide to Meteorological Instruments and Methods of Observation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOTT Hydromet
OriginImported
Manufacturer TypeAuthorized Distributor
ModelOTT ecoN
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
ModelSUVA / SUVB / SUV-E
Spectral Range (SUVA)315–400 nm
Spectral Range (SUVB)280–315 nm
Spectral Range (SUV-E)Erythemal Action Spectrum (CIE 1987) weighted
Output Options0–1 V analog + RS-485 Modbus® RTU digital
Directional Response Error< ±2 % (10° to 80° zenith angle)
Temperature Dependence< ±0.1 %/°C (with integrated thermistor compensation)
Power Consumption< 1.5 mA @ 12 VDC
Operating Temperature–40 °C to +80 °C
IP RatingIP68
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
OriginGermany
ModelWS502-UMB
Measurement PrinciplesUltrasonic time-of-flight (wind speed/direction), NTC thermistor (air temperature), capacitive hygrometer (relative humidity), MEMS barometric pressure sensor, photodiode-based pyranometer (global solar radiation)
Power Supply12–30 V DC, solar-compatible
Communication ProtocolsModbus RTU/ASCII, SDI-12, CAN bus, UMB-protocol (native), optional MQTT/HTTP via gateway
Environmental RatingIP66
Operating Temperature Range–40 °C to +70 °C
Wind Measurement Range0–75 m/s (0.01 m/s resolution), Direction: 0–360° (0.1° resolution)
Temperature Range–40 to +70 °C (±0.2 °C accuracy)
Relative Humidity Range0–100 %RH (±2 %RH typical)
Pressure Range500–1100 hPa (±0.5 hPa)
Radiation Range0–2000 W/m² (±5 % uncertainty)
Integrated Fan AspirationYes
Heating FunctionYes (ultrasonic transducers)
Data OutputReal-time wind quality index (e.g., signal-to-noise ratio, data validity flags), configurable sampling interval (1 s to 10 min)
External Sensor SupportRain gauge (pulse input), Pt100/Pt1000 temperature probes, analog 4–20 mA inputs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOTT Hydromet
OriginGermany
ModelOTT CTD
Pressure Measurement PrincipleDifferential Pressure with Integrated Vent Tube
Temperature SensorPT1000-class RTD
Conductivity MethodFour-Electrode Cell (Low Polarization)
Depth Ranges0–4 m, 0–10 m, 0–20 m, 0–40 m, 0–100 m
Depth Resolution0.01 %FS
Depth Accuracy±0.05 %FS
Temperature Range–25 to +70 °C
Temp. Resolution0.01 °C
Temp. Accuracy±0.1 °C
Conductivity Ranges0.001–2.000 mS/cm and 0.10–100.00 mS/cm
Cond. Resolution0.001 / 0.01 mS/cm
Cond. Accuracy±0.5 % of reading (low range), ±1.5 % of reading (high range)
Housing MaterialDIN 1.4539 (904L) stainless steel, laser-welded
CableKelvar-reinforced polyurethane sheath
Memory4 MB flash (≥500,000 logged values)
Battery OptionsReplaceable AA alkaline, lithium primary (Li-SOCl₂), or rechargeable Li-ion
Lithium Battery Life≥10 years (typical at 15-min logging interval)
CommunicationIR interface (IEC 62209-compliant), optional ITC telemetry unit for SMS/GPRS
EMC ComplianceEN 61000-6-3 / EN 55011 Class B
Overload Capacity4× full scale
Environmental CompensationAutomatic air pressure, temperature, density, and altitude correction
Enclosure RatingIP68 (permanent submersion)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
ModelWS601-UMB
Measurement ParametersWind Speed, Wind Direction, Air Temperature, Relative Humidity, Atmospheric Pressure, Precipitation
PrincipleUltrasonic Time-of-Flight (Wind), NTC Thermistor (Temperature), Capacitive Polymer Sensor (Humidity), MEMS Capacitive Barometer (Pressure), Tipping-Bucket Rain Gauge (Precipitation)
Power SupplyLow-power design, solar-compatible
EnclosureCompact all-in-one housing with active ventilation fan and heated ultrasonic transducers
OutputWind quality indicator, integrated electronic compass, optional external temperature probe support
Communication ProtocolsModbus RTU/ASCII, SDI-12, CAN bus, ASCII serial, optional MQTT/HTTP for IoT integration
ComplianceIP66 rated enclosure, CE marked, RoHS compliant
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOTT Hydromet
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelOTT CWS
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
ModelWS501-UMB
Measurement PrincipleUltrasonic time-of-flight (wind speed & direction), NTC thermistor (temperature), capacitive humidity sensor (relative humidity), MEMS capacitive barometer (atmospheric pressure), thermopile pyranometer (global solar radiation)
Power SupplyDC 12–30 V, solar-compatible
Communication ProtocolsSDI-12, Modbus RTU (RS-485), CAN bus, UMB-ASCII (native), optional MQTT/HTTP via gateway
Wind Measurement Range0–60 m/s (±0.1 m/s @ <5 m/s), 0–360° (±2°)
Temperature Range–40 to +70 °C (±0.2 °C)
Relative Humidity Range0–100 %RH (±2 %RH)
Pressure Range500–1100 hPa (±0.5 hPa)
Radiation Range0–2000 W/m² (±5 %)
Operating Temperature–40 to +70 °C
IP RatingIP66
HeatingIntegrated ultrasonic transducer heating (–40 to +5 °C activation)
Fan-Assisted AspirationYes, continuous low-power fan for radiation and humidity sensor thermal stabilization
Sensor MountingIntegrated, single-mast mounting
Data OutputReal-time analog/digital, quality flags per parameter
ComplianceCE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/-4, WMO Guide to Instruments and Methods of Observation (CIMO) Class II recommended
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOTT Hydromet
OriginImported
ModelOTT SWS
Wind Speed Range0–65 m/s
Wind Speed Accuracy±0.5 m/s or ±5%
Wind Speed Resolution0.1 m/s
Wind Speed Repeatability±0.2 m/s or ±5%
Wind Direction Range0°–360°
Wind Direction Accuracy±5°
Wind Direction Resolution±1°
Measurement PrincipleUltrasonic time-of-flight (orthogonal X/Y axes)
Output InterfacesRS-232C, RS-485, SDI-12
Sensor Power Supply9–36 VDC
Heater Power Supply24 VDC
Power Consumption<0.5 W
Operating Temperature−40 °C to +60 °C
Relative Humidity0–100% RH (non-condensing)
MTBF80,000 hours
Dimensions (H × D)203.2 mm × 101.6 mm
Weight1.0 kg
Mounting3/4″ IPS vertical pipe (26 mm ID)
Optional FeaturesAutomatic north alignment, integrated de-icing heater, field-configurable via serial interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOTT Hydromet
OriginImported
ModelOTT PLS-C
Output OptionsRS485 (SDI-12 protocol) or SDI-12 digital interface
Measurement PrincipleDifferential pressure via vented ceramic capacitive sensor with integrated temperature, density, altitude, and gravity compensation
Accuracy±0.05 mm water column
Overpressure Rating10× full scale
EnclosureLaser-welded stainless steel housing
CableKelvar-reinforced, submersible, long-term dimensional stability
ComplianceDesigned for long-term unattended operation in accordance with ISO 4064-1 (water metering), ASTM D4044 (groundwater monitoring), and USGS NWIS data quality standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOTT Hydromet
OriginGermany
ModelPluvio2
Measurement PrinciplePrecision Weighing
Collection Area200 cm² or 400 cm²
Max. Real-Time Rain Intensity1800 mm/h
Resolution0.01 mm / 0.01 mm/h
Accuracy±0.1 mm
Operating Temperature−40 °C to +60 °C
Heating Option24 VDC / 50 W
Power Consumption180 mW (15 mA @ 12 VDC)
Enclosure RatingIP54 (housing), IP67 (pressure unit), IP64 (electronics)
CommunicationUSB (configuration), SDI-12, RS485, Pulse Output
MaterialStainless steel & aluminum housing, polyethylene collector bucket
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
OriginGermany
ModelWS200-UMB
Measurement PrincipleUltrasonic time-of-flight anemometry
Wind Speed Range0–60 m/s
Wind Direction Range0–360°
Power Supply12–24 VDC, solar-compatible
Operating Temperature−40 to +70 °C
IP RatingIP66
Communication ProtocolsSDI-12, RS-232/485, Modbus RTU, CAN bus, MQTT (optional)
Integrated Electronic CompassYes
Heating FunctionIntegrated ultrasonic transducer heating
Output ParametersWind speed (m/s), wind direction (°), wind quality index (WQI), status diagnostics
External Sensor SupportRain gauge, temperature/humidity probe, barometric pressure sensor
ComplianceCE, RoHS, WMO Guide to Instruments and Methods of Observation (CIMO)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
ModelNR Lite2
Measurement PrincipleThermopile-based Single-Component Net Radiation Sensor
Spectral Range0.3–100 µm
Operating Temperature−40 to +80 °C
Output Signal0–25 mV (analog, proportional to net radiation in W/m²)
Sensitivity~5 µV/(W/m²) typical
Response Time< 1 s (95%)
Zero Offset (Thermal)< ±5 W/m²
Zero Offset (Solar)< ±2 W/m²
Field of View180° (hemispherical)
Housing MaterialAnodized aluminum with anti-stick hydrophobic coating
Cable Length5 m standard (shielded, twisted-pair)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOTT Hydromet
OriginGermany
ModelOTT Pluvio2 S
Collection Area200 cm²
Capacity450 mm
Rainfall Intensity Range0.03–3000 mm/h
Resolution0.01 mm / 0.01 mm/h
Accuracy±0.1 mm or ±1%
Operating Temperature−40 to +60 °C
IP RatingIP67 (load cell & electronics), IP65 (housing)
Power Supply5.5–28 VDC (180 mW)
Output InterfacesSDI-12, RS485 (2-/4-wire), Pulse/Contact, USB (configuration & service)
MTBF>100 years
ComplianceWMO No. 8 (CIMO Guide), ISO 9001, CE, EMC/EMI EN 61000-4-2/4/5/6 Level 5, EN 61000-4-3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOTT Hydromet
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHydrolab HL7
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOTT Hydromet
OriginImported
ModelHACH OTT netDL 500/1000
Communication InterfacesEthernet (RJ45, 10 Mbps for netDL 1000), USB Device/Host, RS-232 (2 ports on netDL 1000
Sensor ProtocolsSDI-12, Modbus RTU
I/O CapabilitiesConfigurable AI/AO, Status I/O (4 on netDL 1000
Integrated Web ServerYes (HTTP/HTTPS with TLS/SSL)
Optional GSM/GPRS ModemMotorola G30
Power Supply9–28 VDC (typ. 12 VDC)
Sleep Current< 250 µA
Active Current25–400 mA (configuration-dependent)
Memory4 MB Flash
Display122 × 32 pixel monochrome LCD with LED backlight
Operating Temperature–40 °C to +70 °C
Enclosure RatingIP41
Dimensions (L×W×H)netDL 1000 — 232 × 124 × 86 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOTT Hydromet
OriginGermany
ModelOTT Parsivel2
Optical PrincipleLaser Extinction (780 nm)
Measurement Area180 × 30 mm (54 cm²)
Particle Diameter Range0.2–5 mm (liquid), 0.2–25 mm (solid)
Velocity Range0.2–20 m/s
Size & Velocity Bins32 × 32
Precipitation Type Recognition8 classes (drizzle, rain, rain/snow mix, snow, graupel, freezing rain, hail, fog)
Rainfall Intensity Range0.001–1200 mm/h
Accuracy±5% (liquid), ±20% (solid)
Visibility Range100–20,000 m (±10%)
Radar Reflectivity Z9.9–99 dBZ (±20%)
Power Supply10–28 VDC
Standby Power1.5 W (60 mA @ 24 VDC)
Heating Power100 W (peak, 24 VDC)
Operating Temperature−40 °C to +70 °C
Enclosure RatingIP65 (sensor head IP67)
ComplianceEN 61000-4-2/3/4/5/6, EN 55022 Class B, CE, WMO-compliant output codes (SYNOP 4677/4688, METAR 4678, NWS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
ModelWS300-UMB
Measurement ParametersAir Temperature, Relative Humidity, Atmospheric Pressure, Dew Point Temperature
Sensor PrinciplesNTC Thermistor (Temperature), Capacitive Polymer (Humidity), MEMS Barometric Sensor (Pressure)
Power SupplyLow-power design, compatible with solar power systems
EnclosureCompact, integrated, IP66-rated housing
Fan-Assisted AspirationIntegrated active ventilation fan for radiation-shielded temperature/humidity measurement
Communication InterfacesRS-232, RS-485, SDI-12, Modbus RTU, CAN bus, UMB-ASCII
ExpandabilitySupports external rain gauge, PT100/PT1000 temperature probes, and third-party analog/digital sensors
ComplianceCE, RoHS, WEEE, EN 61326-1 (EMC), EN 61000-6-2/-6-4
Operating Temperature Range–40 °C to +70 °C
Storage Temperature Range–40 °C to +70 °C
Relative Humidity Range0–100 % RH (non-condensing)
Pressure Range500–1100 hPa
Typical Power Consumption<1.5 W (standby), <3.2 W (fan active)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
OriginImported
ModelLufft Ventus-UMB
Instrument TypeUltrasonic Anemometer
Resolution0.1 m/s
Measurement Range0–90 m/s
Accuracy±0.2 m/s or ±2% RMS (0–65 m/s), whichever is greater
Operating Temperature−40 °C to +60 °C (with integrated heater)
Relative Humidity Range0–100% RH
Protection RatingIP68
Show next