BrandHACH
ModelAPA6000
Measurement PrincipleAutomated titration pump coupled with colorimetric detection
Range (Low)0.05–2.0 mg/L Cu²⁺
Range (High)1.0–10.0 mg/L Cu²⁺
Accuracy (Low)±3% or ±0.03 mg/L (whichever is greater)
Accuracy (High)±5% or ±0.05 mg/L (whichever is greater)
Resolution0.001 ppm
Repeatability±3% of reading or <±0.03 mg/L (whichever is greater)
Cycle Time~4 minutes per analysis
DisplayDigital and graphical output calibrated to Cu²⁺ concentration
Sample Flow Rate20–1000 mL/min
Operating Temperature5–50 °C
Relative Humidity≤95% RH, non-condensing
Inlet Pressure0.17–6.9 bar
Calibration FrequencyConfigurable from twice daily to once weekly (calibration duration: ~35 min)
Analog OutputsTwo isolated 4–20 mA outputs
Alarm OutputsTwo SPDT relays
Power Supply95–240 VAC, 50/60 Hz
Enclosure RatingNEMA 4X (IP65)
Mounting OptionsPanel-mount, benchtop, or wall-mount (hardware included)
Data Storage30-day onboard history with trend and graphical analysis capability
Maintenance IntervalUp to 30 days unattended operation
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
ModelSP510
Measurement PrincipleColorimetric (Titanium Yellow Method)
Range0.3–100 mg/L as CaCO₃
Accuracy±10% of setpoint (0.3–2 mg/L), ±4% of setpoint (5–100 mg/L)
Cycle Time~2 minutes per measurement
Alarm Outputs1 SPDT relay
Power Supply115/230 VAC, 50/60 Hz
CertificationsUL, CSA, CE
Reagent ConsumptionUp to 2 months per reagent pack
Maintenance IntervalPump tube replacement every 6 months
CalibrationAutomatic zero and span calibration supported
ComplianceDesigned for continuous operation in industrial water treatment environments per ISO 9001-manufactured quality system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
ModelMS8000 Series Online Automatic Water Quality Analyzer
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product Origin CategoryImported
ModelHACH Polymetron NA9600 sc
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
ModelAPA6000
Measurement PrincipleFlow Injection Analysis (FIA) with Photometric Detection at 600 nm
RangeTotal Alkalinity: 0–500 mg/L as CaCO₃
Phenolphthalein Alkalinity0–250 mg/L as CaCO₃
Accuracy±5% of reading or ±1.0 mg/L (whichever is greater)
Repeatability±3% of reading or ±0.6 mg/L (whichever is greater)
Response Time (90%)<10 min
Analysis Cycle8 min
Auto-Calibration Interval60 min
Sample Temperature5–50 °C
Analog OutputsTwo isolated 4–20 mA outputs, fully configurable across full scale
Alarm OutputsTwo SPDT relays (230 VAC, 5 A)
Power Supply95–240 VAC, 50/60 Hz ±2 Hz
Enclosure RatingNEMA 4X (indoor) / IEC 529 IP66 with air-purge interface
Drain ConnectionVertical orientation recommended
Sample Flow Rate100–2000 mL/min
Inlet/Outlet Fittings1/4" NPT inlet, 3/4" NPT drain
Sample Pressure0.03–2.04 bar
Dimensions (W×H×D)522 × 627 × 526 mm
Mounting OptionsWall-mounted, benchtop, or panel-mounted
Weight25.5 kg
Data Storage30 days of timestamped results with trend/graphing capability
Key FeaturesFully automated calibration, reagent replenishment, and system cleaning
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
ModelFiltrax
Sample Flow Rate~900 mL/h
Power Supply230 VAC ±10%, 50–60 Hz
Sample Temperature Range5–40 °C
Ambient Operating Temperature−20 to +40 °C
Enclosure RatingIP55 (Outdoor Installation)
Control Unit Dimensions430 × 530 × 220 mm
Filter Housing Dimensions92 × 500 × 340 mm
Weight41 kg
Heated Sample Intake Tubing Length5 m (standard)
Optional Sample Transport Tubing2 m (unheated), 10/20/30 m (heated)
Filtration Cut-off0.15 µm (ultrafiltration membrane)
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginUSA
ManufacturerHACH Company
Product TypeImported
ModelGLI 3400
PricingAvailable Upon Request
Electrode Constant Options0.05, 0.5, 1.0, 5.0, 10.0
Conductivity Range0–200,000 µS/cm (dependent on electrode constant)
Resistivity Range0.001–20 MΩ·cm
Operating Temperature–20 to 200 °C
Max Flow Rate3 m/s
Pressure Rating100 psig at 200 °C
Accuracy±0.01% of reading
Probe Weight0.45 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
ModelAPA6000
Measurement PrincipleColorimetric EDTA Complexation (USEPA-Approved Method)
Low-Range Range0.05–10 mg/L as CaCO₃
High-Range Range10–1000 mg/L as CaCO₃
Accuracy (Low)±5% or ±0.05 mg/L as CaCO₃, whichever is greater
Accuracy (High)±5% or ±2 mg/L as CaCO₃, whichever is greater
Repeatability (Low)±3% or ±0.03 mg/L as CaCO₃
Repeatability (High)±5% or ±2 mg/L as CaCO₃
T90 Response Time (Low)≤5 min
T90 Response Time (High)≤17 min
Cycle Time (Low)4 min
Cycle Time (High)8.2 min
Sample Temp.5–50 °C
Sample Flow Rate100–2000 mL/min
Inlet Pressure0.03–2.04 bar
Drain Fitting3/4″ NPT
Analog OutputsDual 4–20 mA (isolated, configurable for hardness or status)
Alarm OutputsTwo SPDT relays
CertificationsNRTL Listed (UL/CSA), CE Marked
Power Supply95–240 VAC, 50/60 Hz ±2 Hz
Data Storage30-day internal logging with timestamped values, trend plotting, and export via serial interface
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
ModelGLI E53 / E33 / PRO-E3
Measurement PrincipleInductive (Toroidal) Conductivity
Conductivity Range0.0–2,000,000 µS/cm
TDS Range0–9,999 ppm
Concentration Range0.0–200% w/w
Temperature Range−20.0 to +200.0 °C
Accuracy (Conductivity)±0.2% FS (E53/E33), ±0.05% FS (PRO-E3)
Repeatability±0.1% FS (E53/E33), ±0.05% FS (PRO-E3)
OutputDual 4–20 mA (E53/E33), Single 4–20 mA (PRO-E3)
Enclosure RatingNEMA 4X / IP65 (E53/E33), NEMA 4X + Class I, Div 2, Groups A/B/C/D, T5 (PRO-E3)
Power Supply190–260 VAC (E53/E33), 16–30 VDC (PRO-E3)
InstallationPanel-mount, wall-mount, or pipe-mount
ComplianceCE, UL 61010-1, ATEX/IECEx (PRO-E3), FDA 21 CFR Part 11-ready software support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
ModelUVASsc
Measurement PrincipleUV Absorption at 254 nm
Optical Path Length Options1 mm, 2 mm, 5 mm, 50 mm
Measuring Range Options0.01–60 m⁻¹, 0.1–600 m⁻¹, 0–1500 m⁻¹, 2–3000 m⁻¹
Measurement Cycle1 minute
Response Time>1 min (adjustable)
Turbidity CompensationDual-beam optical system
Analog OutputsTwo isolated 0/4–20 mA outputs (max. load 500 Ω)
Communication ProtocolsMODBUS RTU or PROFIBUS DP (configurable)
Enclosure RatingIP65
Operating Temperature+2 °C to +40 °C
Probe Pressure RatingMax. 0.5 bar (suitable for submersion up to 2 m depth)
Power Supply230 VAC ±10%, 50 Hz, 15 VA OR 24 VDC/AC ±25%, 800 mA
Probe DimensionsØ70 × 333 mm
Probe Weight~3.6 kg
Installation OptionsImmersion or flow-through cell
Self-cleaning MechanismMechanical wiper integrated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
ManufacturerHACH Company
ModelU53
Measurement PrincipleUltrasonic Time-of-Flight (Pulse-Echo)
Range0.25–6.0 m
Depth Resolution±1 mm
Accuracy±0.5% of full scale
Repeatability±0.1% of full scale
Sensitivity±0.1% of full scale
Temperature Compensation Range–40 to +80 °C
Operating Ambient Temperature–20 to +60 °C
OutputTwo independent 4–20 mA or 0–20 mA analog outputs
RelaysFour SPDT relays
Enclosure RatingNEMA 4X (IP65)
Mounting OptionsPanel, surface, and pipe mounting
Sensor Weight1.6 kg
Sensor Cable Length3.05 m (10 ft)
Instrument Weight0.5 kg
Flow UnitsL/s, m³/s, gal/min, ft³/s, ML/d, Mgal/d
Depth Unitsmm, m, in, ft
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Model3700 Series Electrodeless Conductivity Sensor
Connection InterfaceDigital (SC100/SC1000 Compatible)
Sensor Body MaterialsPolypropylene (PP), Polyvinylidene Fluoride (PVDF), Perfluoroalkoxy (PFA), Polyetheretherketone (PEEK)
Process Connections2" Sanitary Clamp or 2" NPT
Standard Cable Length6 m (with 1 m extension cable and digital adapter D6120800)
ComplianceDesigned for continuous online water quality monitoring in compliance with ISO 7888, ASTM D1125, and USP <645> conductivity requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
ModelpH/ORP Digital Sensor
OriginImported
ManufacturerHACH Company
Sensor InterfaceDigital (HACH SC Series Compatible)
Cable Options4.5 m integrated cable (standard), 10 m cable (6120600/6120500 variants)
Temperature RatingUp to 70°C (PEEK/Ryton models), 60°C (stainless steel models)
Electrode TypesGlass pH (standard & HF-resistant), Pt or Au ORP
MaterialsRyton®, PVDF, 316SS, PEEK
Temperature CompensationIntegrated Pt1000 RTD
ComplianceDesigned for continuous online water quality monitoring per ISO 5667, ASTM D1293, USP <791>, and EPA Method 150.1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Model3400 Series Digital Conductivity Sensor
Sensor Constants0.05, 0.5, 1.0, 5.0, 10 cm⁻¹
Cell MaterialsTitanium (D3422), Graphite (D3433), 316 Stainless Steel (D3444/D3455), Sanitary 316SS with Hygienic Flange (D3455)
Connection InterfaceDigital Bus (HACH Smart Sensor Protocol)
Cable Length6–7 m standard (with 1 m extension kit included for D3433/D3444/D3455)
Compatible ControllersSC100 and SC1000 Universal Digital Controllers
Mounting TypesInsertion (D3422), Submersible (requires analog 3422 analog variant), Sanitary Flanged (D3455)
Enclosure MaterialPVDF or Ryton per model
Electrical InterfaceIntegrated digital bus connector with auto-ID and calibration memory
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
ModelOWF-100
Measurement PrincipleUV Fluorescence
Range0–2.0 mg/L and 0–10 mg/L (selectable)
Repeatability±7% FS
Stability±5% FS/day (in deionized water)
Response TimeT90 = 3 min
Sample Temperature0–30 °C
Sample Pressure0.02–0.3 MPa
Sample Flow Rate2–7 L/min
Ambient Operating Temperature0–45 °C
Analog Output4–20 mA, max. load 600 Ω
Power Supply220 VAC ±10%, 50/60 Hz
Power Consumption~50 VA
Dimensions (W×H×D)300 × 1500 × 500 mm
Weight40 kg
InstallationIndoor only
Optical DesignWindowless full-flow measurement cell
MaintenanceNo moving parts, reagent-free operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer StatusManufacturer
Measurement PrincipleUV Absorption (Dual-Beam, 210 nm)
Optical Path Lengths1 mm, 2 mm, 5 mm
NO₃–N Range0.1–100.0 mg/L (1 mm), 0.1–50.0 mg/L (2 mm), 0.1–25.0 mg/L (5 mm)
LOD (NO₃–N)0.1 mg/L (typical)
Accuracy±3% ±0.5 mg/L (1 mm), ±5% ±1.0 mg/L (2 mm), ±5% ±0.5 mg/L (5 mm)
Resolution0.1 mg/L or 0.5 mg/L depending on configuration
Sludge CompensationYes
Measurement Interval1 min or 5 min
Response Time (T₁₀₀)≤1 min (1 mm path), ≤15 min (2 mm path)
Installation OptionsImmersion & Flow-Through Cell
Housing MaterialStainless Steel (316L), Dual-Sealed or Single-Sealed variants
CalibrationStandard Solution-Based
Maintenance IntervalEvery 6 months
Operating Temperature2–40 °C
Max Submersion Depth2 m (0.5 bar)
Probe Cable Length10 m (extendable)
Dimensions (L × D)33.3 × 7.0 cm, 32.7 × 7.0 cm, or 32.3 × 7.5 cm
Self-Cleaning FunctionIntegrated ultrasonic or mechanical wiper (model-dependent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
ModelTC2300
TypeOnline Optical Particle Counter
OriginImported (USA-manufactured)
ManufacturerHACH Company, a Danaher Corporation business
Particle Detection PrincipleLight Obscuration (LO) / Single-Particle Optical Sizing (SPOS)
Measurement Channels8 user-selectable size thresholds
Flow ControlIntegrated precision peristaltic sampling pump with adjustable flow rate (typically 20–60 mL/min)
Display7-inch full-color capacitive touchscreen interface
ComplianceDesigned to support ASTM D6978-05 (for clean water), ISO 21501-4, and USP <788> & <789> particulate matter testing guidelines (when configured per application requirements)
Data OutputModbus RTU/TCP, 4–20 mA analog outputs, optional Ethernet/IP or OPC UA integration
Enclosure RatingIP65-rated NEMA 4X housing for industrial environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
ModelTxpro-2
Measurement PrincipleQuadruple-beam Optical Transmission/Scattering
Measurement Range (RD240/242)0–10 g/L
Measurement Range (RD260/262)0–25 g/L
Accuracy (RD240/242)±2% of reading or ±0.1 g/L, whichever is greater
Accuracy (RD260/262)±2% of reading or ±0.2 g/L, whichever is greater
Repeatability (RD240/242)±2% of reading or ±0.05 g/L, whichever is greater
Repeatability (RD260/262)±2% of reading or ±0.1 g/L, whichever is greater
Operating Temperature–20 °C to +55 °C
Analog OutputsTwo isolated 0/4–20 mA outputs, max. load 800 Ω
RelaysThree SPDT relays, 2 A @ 250 VAC
Signal AveragingAdjustable from 1 second to 5 minutes
Power Supply90–265 VAC, 50/60 Hz
Max. Power Consumption25 VA
Enclosure RatingNEMA 4X (IP66)
MountingPipe clamp for up to 50 mm OD pipe
ComplianceCE, UL 61010-1, CSA C22.2 No. 61010-1
Dimensions144 × 144 × 150 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
ManufacturerHACH Company
ModelAMTAX sc
Measurement PrincipleGas-Sensing Electrode (Ammonia-Selective Electrode)
Measurement Ranges (as NH₄-N)Low Range: 0.05–20 mg/L
Medium Range1–100 mg/L
High Range10–1000 mg/L
LOD0.05 mg/L (low), 1 mg/L (medium), 10 mg/L (high)
Accuracy±3% ±0.05 mg/L (low), ±3% ±1.0 mg/L (medium), ±4.5% ±10 mg/L (high)
Repeatability±2% ±0.05 mg/L (low), ±2% ±1.0 mg/L (medium), ±2% ±10 mg/L (high)
Response Time (T₉₀)≤5 min
Measurement IntervalAdjustable from 5 to 120 min
Sample Temp.4–40 °C
Sample pH5–9
Operating Temp.−20–45 °C
Relative Humidity≤95% non-condensing
Power Supply230 VAC/50 Hz or 115 VAC/50–60 Hz
Power Consumption100 W nominal (peak: 1000 VA)
Enclosure RatingIP66
Sample Flow Rate≤3 m/s
Filtrate Flow≥5 mL/min for ≥4 min per 5-min cycle
External Cabinet Dimensions540 × 720 × 390 mm
Analyzer Weight35 kg (incl. reagents)
Cable Length2 m from enclosure
Optional Heated Sampling Hose5 m or 10 m