Empowering Scientific Discovery

Hach Company

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSea-Bird Scientific
OriginImported
Manufacturer TypeAuthorized Distributor
ModelHydro-T
Measurement Range–5 to 45 °C
Initial Accuracy±0.002 °C
Typical Stability<0.002 °C/year
Resolution0.0001 °C
Clock Accuracy±5 seconds/month
BatterySaft LS14500 3.6 V Li-SOCl₂ (hazard-free)
Sampling Capacity15.9M samples
Max Deployment DurationUp to 2 years (dependent on sampling interval)
Housing MaterialEngineering-grade polymer
Pressure Rating1500 m (4900 ft)
Weight0.2 kg (air), 0.05 kg (water)
Calibration11-point NIST-traceable calibration in SBE’s ISO/IEC 17025-accredited thermal calibration bath
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Instrument TypePortable
Measurement PrincipleIon-Selective Electrode (ISE)
Sensor ArchitectureIntegrated CARTRICAL Cartridge with pH, Temperature, and Selective Electrodes
CalibrationFactory-Calibrated Cartridge
Maintenance Interval~2x per year (typical operation)
Sample HandlingNo pretreatment required
Controller CompatibilitySC100 / SC200 / SC1000 Digital Controllers
Housing MaterialStainless Steel Body with Ryton End Caps
Immersion RatingFully Submersible
Mounting OptionsRod, Chain, or Wall-Mount Kits
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: HACH
Model9123
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
ModelAPA6000
Measurement PrincipleAutomated titration pump coupled with colorimetric detection
Range (Low)0.05–2.0 mg/L Cu²⁺
Range (High)1.0–10.0 mg/L Cu²⁺
Accuracy (Low)±3% or ±0.03 mg/L (whichever is greater)
Accuracy (High)±5% or ±0.05 mg/L (whichever is greater)
Resolution0.001 ppm
Repeatability±3% of reading or <±0.03 mg/L (whichever is greater)
Cycle Time~4 minutes per analysis
DisplayDigital and graphical output calibrated to Cu²⁺ concentration
Sample Flow Rate20–1000 mL/min
Operating Temperature5–50 °C
Relative Humidity≤95% RH, non-condensing
Inlet Pressure0.17–6.9 bar
Calibration FrequencyConfigurable from twice daily to once weekly (calibration duration: ~35 min)
Analog OutputsTwo isolated 4–20 mA outputs
Alarm OutputsTwo SPDT relays
Power Supply95–240 VAC, 50/60 Hz
Enclosure RatingNEMA 4X (IP65)
Mounting OptionsPanel-mount, benchtop, or wall-mount (hardware included)
Data Storage30-day onboard history with trend and graphical analysis capability
Maintenance IntervalUp to 30 days unattended operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Instrument TypePortable
Measurement PrincipleCoulometric Titration (Acidic/Alkaline KMnO₄ Method)
Measurement Range0–5000 mg/L as O₂
Accuracy±2% of full scale
Repeatability±2% of full scale
Detection Limit0.2 mg/L
Typical Analysis Time15 minutes
Batch CapacitySingle-sample per run
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer StatusManufacturer
ModelAnatel PAT700
Measurement Range0.5–2,000 ppb C TOC
Repeatability±0.3 ppb or ±1% (whichever is greater)
Accuracy±1 ppb or ±5% (whichever is greater)
TOC Resolution0.1 ppb
Conductivity/Resistivity Resolution0.01 µS/cm or MΩ·cm
Temperature Resolution0.1 °C
Conductivity CompensationTemperature-compensated and non-temperature-compensated modes
Inlet Pressure10–100 psig (69–690 kPa)
Flow Rate60–300 mL/min
Analog OutputsThree 4–20 mA
Digital I/OTwo digital inputs, four digital outputs
Communication InterfacesRS232, USB, Ethernet, Serial printer port
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ManufacturerHach Company
Product TypeImported Instrument
ModelHQd Series
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer StatusOriginal Equipment Manufacturer (OEM)
Model3650EX
Power Supply2 × AA NiCd or alkaline batteries (2.4–3 V DC)
Battery LifeUp to 40 hours continuous operation
Measurement PrincipleElectrochemical amperometric sensing with proprietary membrane-based sensor
Enclosure RatingIP67 / NEMA 4X
CertificationATEX II 1G Ex ia IIC T4 Ga
Temperature Range–5 °C to +100 °C
Output InterfaceRS-232 serial digital interface
Zero Drift< 0.5 % FS per 24 h
Housing MaterialFully stainless steel (316L)
Data LoggingInternal non-volatile memory with PC download capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
ModelTitraLab AT1000
Titration TypesPotentiometric (zero-current or controlled-current), Amperometric, Colorimetric
Titration ModesSample, Blank, Sample + Blank, QC Sample, QC Sample + Blank
Measured ParametersmV/pH, Conductivity, Temperature
ResolutionmV/pH: ±0.1 mV / ±0.001 pH
Conductivity±0.5% of reading
Temperature±0.3 °C / ±0.51 °F
Sample HolderIntegrated design with magnetic stirring
max. beaker capacity250 mL
Electrode InputsDual-channel
Burette Capacities2.5 / 5 / 10 / 25 mL (ISO 8655-3 compliant)
Motor Resolution20,000 steps with microstepping (128 μsteps/step)
Calibration ModesElectrode & titrant calibration — automatic, fixed-point, or user-defined (up to 5 points)
Calibration SchedulingConfigurable interval-based alerts and reminders
Data StorageLast 100 measurements (samples, blanks, QC samples) + last 10 calibrations, including timestamp, operator ID, sample ID
Data ExportUSB drive
Interface5.7" color VGA touchscreen
Calibration Curve DisplayDirect or derivative plots
Connectivity2× electrode ports, 2× USB, 1× RS-232, 1× Ethernet
Dimensions (H×W×D)220 × 400 × 360 mm
Weight4 kg
Power Supply100–240 V AC, 50/60 Hz
Operating Environment15–35 °C, 20–80% RH (non-condensing)
Storage Range−5–40 °C
Safety CertificationIEC/EN 61010-1
EMC ComplianceIEC/EN 61326-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
ApplicationLaboratory Use
Measured ParameterTotal Phosphorus
Measurement PrincipleAcidic Persulfate Digestion + Ammonium Molybdate Colorimetry at 880 nm
Measurement Range0.01–3.8 mg/L as PO₄–P
Accuracy<2% at 1 mg/L
Detection Limit0.01 mg/L
Resolution0.001 mg/L
Sample pH Range2–10
Digestion Conditions150 °C, 6 bar
Particle ToleranceUp to 100 µm
Calibration MethodSingle- or Multi-point
Auto-sampler Options36-position (with stirring) or 53-position (without stirring)
DisplayColor LCD
Weight40 kg (digestion/analysis unit), 5 kg (auto-sampler)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ManufacturerHach Company
Product TypeImported
ModelCL17D Residual and Total Chlorine Analyzer – Distribution Network Version
Instrument TypeOnline Analyzer
Measurement PrincipleDPD Colorimetric Method (N,N-Diethyl-p-phenylenediamine)
Measured ParameterResidual Chlorine / Total Chlorine
Range0–5 mg/L as Cl₂
Accuracy±5% or ±0.005 mg/L as Cl₂ (whichever is greater)
Repeatability±0.035 mg/L or ±5% as Cl₂ (whichever is greater)
Detection Limit0.035 mg/L as Cl₂
Sample Temperature Range5–40 °C
Cycle Time10 minutes
Analog Output4–20 mA (configurable across 0–5 mg/L range)
Alarm OutputsTwo user-configurable concentration alarms, each with SPDT relay (5 A, 230 VAC)
Dimensions42 × 32 × 18 cm
Turbidity & Color CompensationAutomatic
CalibrationBuilt-in calibration curve
Diagnostic CapabilitySelf-diagnostic system
Reagent LifetimeUp to 120 days (unopened)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTrojan
OriginImported
Manufacturer TypeAuthorized Distributor
ModelTrojanUVSigna
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelCA9400 Single-Channel / Dual-Channel Transmitter
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelEclox
Instrument TypePortable
Biological Indicator*Aliivibrio fischeri* (freeze-dried, ISO 11348-compliant)
Operating Temperature Range−20 °C to +55 °C
IP RatingIP67
Weight1.4 kg (instrument only, with batteries)
Dimensions230 × 77 × 125 mm (instrument)
Power Supply4 × AA alkaline batteries (≥250 tests per set)
DisplayBacklit graphical LCD
Data Storage32 KB non-volatile memory
InterfaceRS232 serial output
Measurement TimeDefault 15 s (configurable: 6–20 s)
Toxicity Screening Range0–100% inhibition (linear response: 10–90%)
Screening Assay Duration5, 15, or 30 min
CertificationCE Marked
Bacterial Reagent Storage−18 °C (12 months)
Reagent Shelf LifeChemical luminescence reagents — 24 months at room temperature
Additional Onboard ParametersResidual chlorine, total chlorine, arsenic (colorimetric), pH, conductivity (TDS), platinum-cobalt color, organophosphate nerve agents, carbamate insecticides
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginUSA
ManufacturerHACH Company
Product TypeImported Instrument
ModelPolymetron 9210
PricingUpon Request
Measurement Range0–1000 ppb or 0–5000 ppb SiO₂
Repeatability±0.5 ppb / ±2 ppb
Detection Limit<0.5 ppb / <2 ppb
Cycle Time10 min per channel
Operating Pressure0.2–2 bar
Operating Temperature5–50 °C
Sample Flow Rate15–20 L/h
Communication InterfaceRS-485
Analog Output4–20 mA
Channel Capacity1–6 channels
CalibrationDual-point (chemical zero & slope)
Data LoggingIntegrated memory with timestamped records
User InterfaceGraphical menu with intuitive navigation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Measurement PrincipleCoulometric Titration with Acidic Potassium Permanganate Oxidation
Range0–20 / 40 / 100 / 200 / 400 / 1000 mg/L as O₂
Repeatability±2% RSD
Accuracy±5% of reading
LOD0.4 mg/L
Resolution0.01 mg/L
Single-Test Duration5–10 min
Data Storage100 test records
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
ManufacturerHACH Company
ModelAmtax™ Compact
Instrument TypeOnline Analyzer
Measurement PrincipleGas-Phase Separation with Colorimetric Detection (Nesslerization-based)
Range Options0.2–12.0 mg/L NH₄–N
Accuracy±2.5% of reading or ±0.2 mg/L (whichever is greater, per certified standard solution)
Detection Limit0.5 mg/L NH₄–N
Cycle Time13–120 min (user-selectable)
Output Signals4–20 mA (max. load 500 Ω)
Digital InterfacesRS485 / RS232 with Modbus RTU or PROFIBUS DP protocol support
Alarm OutputsTwo programmable relay outputs (24 V DC, 1 A each)
Sample ChannelsDual-inlet capability (two independent sample streams)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelMS9000
Instrument TypeOnline Water Quality Analyzer
Measured ParameterspH, Dissolved Oxygen (DO), Electrical Conductivity (EC), Turbidity, Permanganate Index (COD<sub>Mn</sub>), Ammonia Nitrogen (NH<sub>3</sub>-N), Total Phosphorus (TP), Total Nitrogen (TN), Temperature
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Instrument TypeOnline Analyzer
Measurement PrincipleColorimetric Distillation Method
Measurement Range0.2–1200 mg/L NH₄–N
Accuracy≤ ±5% (varies by range
Detection Limit0.2 mg/L NH₄–N
Measurement IntervalUser-definable (13 min to 24 h)
Batch Capacity>10 samples per cycle
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
ModelTOC600
Instrument TypeOnline TOC Analyzer
Detection PrincipleDirect Conductivity Method
Oxidation MethodUV Photolysis
Measurement Range1–1000 ppb C
Accuracy±2% (10–40 °C), ±5% (40–50 °C)
Resolution1 ppb C
Repeatability±1% or ±1 ppb (whichever is greater)
Inlet Conductivity Range0.05–150 mS/cm
Inlet Pressure10–100 psig (69–690 kPa)
Flow Rate60–300 mL/min
Output Options4–20 mA, RS-232/RS-485
Operating EnvironmentAmbient ≤70 °C (heat sink required above 70 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
ModelSP510
Measurement PrincipleColorimetric (Titanium Yellow Method)
Range0.3–100 mg/L as CaCO₃
Accuracy±10% of setpoint (0.3–2 mg/L), ±4% of setpoint (5–100 mg/L)
Cycle Time~2 minutes per measurement
Alarm Outputs1 SPDT relay
Power Supply115/230 VAC, 50/60 Hz
CertificationsUL, CSA, CE
Reagent ConsumptionUp to 2 months per reagent pack
Maintenance IntervalPump tube replacement every 6 months
CalibrationAutomatic zero and span calibration supported
ComplianceDesigned for continuous operation in industrial water treatment environments per ISO 9001-manufactured quality system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
ModelMS8000 Series Online Automatic Water Quality Analyzer
PricingUpon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0