- All
- Favorite
- Popular
- Most rated
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 9073 |
| Ion Type | Sodium |
| Measurement Range | 0–0.01 ppb and 0–10,000 ppm (user-selectable) |
| Repeatability | <5% of reading or ±0.05 ppb (whichever is greater) |
| Response Time (T90) | <2 min |
| Analog Outputs | Two 4–20 mA outputs (max. load: 900 Ω) |
| Operating Temperature | 5–45 °C |
| Power Supply | 220 VAC, 50/60 Hz |
| pH Conditioning Required | Yes (pH >10) |
| Electrode Type | Sodium-selective glass electrode |
| Calibration Method | AUTOCAL (automated 1- or 2-point standard addition) |
| Sample Handling | Integrated pH adjustment and acid-tolerant configuration available |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | POLYMETRON 9523 |
| Instrument Type | Multi-Ion Analyzer |
| Compliance | ISO 7888, ASTM D1125 |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company |
| Instrument Type | Online Sodium Analyzer |
| Measurement Range | 0–10,000 ppb (programmable up to 0–200 ppm) |
| Detection Limit | 0.01 ppb |
| Response Time (T90) | 180 s |
| Accuracy | ±6 mg/L at 100 mg/L |
| Temperature Operating Range | 5–50 °C |
| Enclosure Rating | IP65 |
| Power Supply | 90–240 VAC, ±10%, 50/60 Hz, 80 VA |
| Calibration | Manual 1-point or 2-point |
| Communication Protocols | Modbus RTU (JBUS), Profibus DP |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | EZ1005.99001102, EZ1005.99001E02 |
| Instrument Type | Online Analyzer |
| Measuring Range | 1–10 mg/L Cl⁻ |
| Detection Limit | ≤1 mg/L Cl⁻ |
| Response Time | 10 min (including dilution + 5 min measurement) |
| Accuracy | ≤2% F.S. (with certified standard solutions) |
| Operating Temperature | 10–30°C |
| Sample Flow Rate | 100–300 mL/min |
| Sample Turbidity Limit | <50 NTU |
| Max Particle Size | 100 µm |
| Sample Solids Content | <0.1 g/L |
| Power Supply | 110–240 VAC, 4 A, 50/60 Hz, Max 150 VA |
| Analog Output | 4–20 mA (standard 1 channel, up to 8 optional) |
| Digital Communication | RS232, Modbus TCP/IP, Modbus RTU (RS485) |
| Enclosure Rating | IP55 (analyzer), IP65 (panel PC) |
| Dimensions | 690 × 465 × 330 mm |
| Weight | 25 kg |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | EZ3003.99001102, EZ3004.99001102, EZ3005.99001102 |
| Measurement Range | EZ3003: 1–10 mg/L Cl⁻ |
| EZ3004 | 10–100 mg/L Cl⁻ |
| EZ3005 | 100–1,000 mg/L Cl⁻ |
| Detection Limit | ≤1 mg/L Cl⁻ |
| Response Time | 5 min |
| Accuracy | ≤2% F.S. (using certified standard solutions) |
| Operating Temperature | 10–30 °C |
| Sample Temperature Range | 10–30 °C |
| Sample Flow Rate | 100–300 mL/min |
| Power Supply | 110–240 VAC, 4 A, 50/60 Hz, max. 150 VA |
| Analog Output | 4–20 mA (1 channel standard, up to 8 optional) |
| Digital Output | RS232, Modbus TCP/IP or RS485 (optional) |
| Enclosure Rating | IP55 (analyzer), IP65 (panel PC) |
| Dimensions | 690 × 465 × 330 mm |
| Weight | 30 kg |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | EZ3503, EZ3504, EZ3505 |
| Instrument Type | Online Chloride Analyzer |
| Measurement Range | EZ3503: 1–10 mg/L Cl⁻ |
| EZ3504 | 10–100 mg/L Cl⁻ |
| EZ3505 | 100–1,000 mg/L Cl⁻ |
| Detection Limit | ≤1 mg/L Cl⁻ |
| Response Time | 8 minutes |
| Accuracy | ≤2% F.S. (with certified standard solutions) |
| Operating Temperature | 10–30 °C |
Show next