BrandHACH
OriginImported
Manufacturer TypeManufacturer
ModelTOC600
Instrument TypeOnline TOC Analyzer
Detection PrincipleDirect Conductivity Method
Oxidation MethodUV Photolysis
Measurement Range1–1000 ppb C
Accuracy±2% (10–40 °C), ±5% (40–50 °C)
Resolution1 ppb C
Repeatability±1% or ±1 ppb (whichever is greater)
Inlet Conductivity Range0.05–150 mS/cm
Inlet Pressure10–100 psig (69–690 kPa)
Flow Rate60–300 mL/min
Output Options4–20 mA, RS-232/RS-485
Operating EnvironmentAmbient ≤70 °C (heat sink required above 70 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
ManufacturerHACH Company
Model Numbers8653600, 8651600
Instrument TypeOnline TOC Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodUV/Persulfate Oxidation
Measurement Range0–25 mg C/L to 0–100 mg C/L (Auto-ranging)
Accuracy±0.5 mg C/L or ±3% of reading (whichever is greater)
Resolution0.5 mg C/L
Detection Limit0.5 mg C/L
RepeatabilityTOC: ±0.5 mg C/L or ±2% of reading (whichever is greater)
TIC±4% of reading
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Instrument TypeOnline TOC Analyzer
ModelAstroTOC™ HT
Oxidation MethodHigh-Temperature Catalytic Combustion (Pt-catalyzed, 680 °C)
Measurement Range0–25 mg/L to 0–20,000 mg/L TOC
Accuracy±5% of reading (≤1000 mg/L, undiluted, 25 °C)
Detection Limit<0.1 mg/L (at 0–25 mg/L range, 25 °C)
Repeatability±5% of reading (≤1000 mg/L) or ±2% (2000–20,000 mg/L), undiluted, 25 °C
Response Time (T₉₀)<8 minutes
Sample Flow Rate20–200 mL/min
Sample Temperature Range2–70 °C
Operating Ambient Temperature5–40 °C
Inlet Pressure0.15–6 bar
Power Supply115/230 VAC, 50/60 Hz, max. 1500 W
Enclosure RatingIP54 / NEMA 12
Dimensions (H×W×D)983 × 973 × 244 mm
Weight97 kg
CertificationsCE, UL 61010-1, CSA C22.2 No. 61010-1
Carrier GasCO₂-free air or nitrogen, 2.8–6.2 bar
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Instrument TypeLaboratory TOC Analyzer
ModelQbD1200+
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodUV/Persulfate Oxidation
Measurement Range0–100 ppm
Accuracy±3% (≥500 ppb)
Repeatability<2%
Detection Limit<50 ppb (typical, per USP <643> and EP 2.2.44)
Resolution0.01 ppm
ComplianceUSP <643>, EP 2.2.44, JP 2.49, ICH Q5A(R2), FDA 21 CFR Part 11, GLP/GMP-ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Instrument TypeOnline TOC Analyzer
Detection PrincipleDirect Conductivity Measurement
Oxidation MethodUV Photolysis (185/254 nm)
Measurement Range0.05–1999 ppb C
Accuracy±0.5 ppb or ±5% of reading, whichever is greater
Detection Limit0.05 ppb C
Repeatability±0.05 ppb (for TOC < 5 ppb)
Conductivity Range for Sample Inlet0.05–5 µS/cm (Auto Mode), 0.05–100 µS/cm (Clean Mode)
Maximum Inlet Pressure< 100 psig (690 kPa)
Display Resolution0.01 ppb (0.00–19.99 ppb), 0.1 ppb (20.0–199.9 ppb), 1 ppb (200–1999 ppb)
Sensor OptionsS10, S20, or S20P
CommunicationRS-485 (Modbus RTU)
Data OutputLocal print support, real-time analog output (4–20 mA), digital interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Model(s)QP1680-TOC, QP1680-TOC/TN, QP1680-TN
Instrument TypeLaboratory TOC/TN Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodHigh-Temperature Catalytic Combustion
Measurement RangeTC, TIC, NPOC, TN: 0–30,000 mg/L
Detection LimitsTC/TIC/NPOC > 50 µg/L
ResolutionParticles ≤ 800 µm
Repeatability< 5% (0–10 mg/L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer StatusManufacturer
Instrument TypeOnline TOC Analyzer
Oxidation MethodUV/Persulfate
Measurement PrincipleNDIR Detection of CO₂ after Acidification and Catalytic Oxidation
Measurement Range0–5 mg/L to 0–20,000 mg/L (multi-range)
Accuracy±2% of reading (non-diluted), ±4% (diluted)
Detection Limit≤0.015 mg/L at 25°C (0–5 mg/L range)
Response TimeT₉₀ ≤ 8 min, T₂₀ ≤ 3 min
Sample Pressure0.15–6 bar (2–87 psig)
Flow Rate25–200 mL/min
Operating Temperature2–70°C (sample), 5–40°C (ambient)
Humidity≤80% RH at 31°C
CommunicationRS232/RS485 (optional)
Analog OutputDual 4–20 mA
Power Supply115/230 VAC, 50/60 Hz
Dimensions981 × 675 × 20 mm
Weight54 kg
ComplianceUSEPA Method 415.1, Standard Methods 5310C, ISO 8027
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeLaboratory-Based TOC Analyzer
ModelQP1680 TOC Analyzer
Oxidation MethodHigh-Temperature Catalytic Combustion (680 °C)
Detection PrincipleNon-Dispersive Infrared (NDIR) Detection of CO₂
Measurement Range0.5–30,000 µg/L (ppb to ppm) as C
Detection Limit≤0.5 µg/L (ppb) as C
Sample ThroughputUp to 60 samples per hour with autosampler
ComplianceASTM D5997, USP <643>, EP 2.2.44, ISO 8245, and compliant with FDA 21 CFR Part 11 requirements for electronic records and signatures
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Instrument TypeOnline TOC Analyzer
Oxidation MethodUV/Persulfate (Acid + UV)
Detection PrincipleNDIR (Non-Dispersive Infrared)
Measurement Range0–2.000 / 5.000 / 10.000 / 25.000 / 50.000 mg/L
Detection Limit≤5 µg/L (at 25°C, 0–5000 µg/L range)
Response TimeT₉₀ ≤ 5 min
Sample Flow Rate25–200 mL/min
Sample Temperature2–70°C
Operating Temperature5–40°C
Inlet Pressure0.15–6 bar
OutputDual 4–20 mA (user-configurable)
Alarms5 programmable alarms (TOC concentration, system fault, shutdown)
CommunicationRS232/RS485 (Modbus RTU, CSV)
Power Supply115/230 VAC, 50/60 Hz
Enclosure RatingIP66 / NEMA 4
Dimensions (W×H×D)981 × 675 × 220 mm
Weight54 kg
Carrier GasCO₂-free air or nitrogen (2.8–6.2 bar)
CertificationsCE, UL, CSA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelQbD1200
Instrument TypeOnline TOC Analyzer
Detection PrincipleUV-Persulfate Oxidation with NDIR Detection
Oxidation MethodUV (254 nm) + Sodium Persulfate
Measurement Range0.4 ppb – 100,000 ppb (as C)
Accuracy±2% of reading or ±3 ppb (whichever is greater)
Resolution1 ppb
Detection Limit0.4 ppb
Repeatability±2% of reading or ±3 ppb (whichever is greater)
Analysis Time~5 minutes per sample
Calibration CycleAutomated 90-minute calibration
Sample Carryover<0.2% (from 500 ppb to baseline)
Overload RecoveryFull recovery to 1 ppb after single measurement at 1,000 ppm
Auto-ranging & Auto-dilutionYes
Reagent RequirementSingle reagent system (acid + oxidant pre-mixed or separately supplied)
Power Supply100–240 VAC, 47–63 Hz
Dimensions (Analyzer)320 × 507 × 410 mm
Weight10 kg
Operating Environment10–35 °C, ≤90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model8653800
Instrument TypeOnline TOC Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodUV/Persulfate with Hydroxyl Radical Enhancement (O₂ carrier gas mode) or UV/Persulfate alone (instrument air carrier gas mode)
Operating Temperature Range5–45 °C
Accuracy±0.5 mg C/L or ±3% of reading (whichever is greater)
Resolution0.5 mg C/L
Detection Limit>0.5 mg C/L
RepeatabilityTOC: ±0.5 mg C/L or ±2% of reading (whichever is greater)
TIC±4% of reading
Sample Pathway4 mm ID integrated flow cell, no pretreatment required
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Instrument TypeOnline TOC Analyzer
ModelQL3580M
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodUV/Persulfate with Hydroxyl Radical Enhancement
Measurement Range0–10 mg C/L
Accuracy±3% of reading or ±0.05 mg C/L (whichever is greater)
Resolution0.5 mg C/L
Detection Limit0.5 mg C/L
Repeatability±2% of reading or ±0.05 mg C/L (whichever is greater)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Instrument TypeOnline TOC Analyzer
ModelA-1000XP
Detection PrincipleDirect Conductivity Measurement
Oxidation MethodUV Photolysis (185/254 nm)
Measurement Range0.05–1999 ppb C
Accuracy±0.05 ppb (MDL to 0.999 ppb)
Detection Limit0.02 ppb C
Conductivity Cell Temperature Control±0.01 °C
Inlet Water Resistivity Requirement (Auto Mode)15.0–18.2 MΩ·cm
Inlet Conductivity Range (Clean Mode)0.05–100 µS/cm
Max Inlet Pressure100 psig (690 kPa)
Display Resolution0.001 ppb C
Communication InterfacesRS-232 (local printing), RS-485 (modbus RTU, up to 1200 m)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
ModelBIOTECTOR B3500dw
Instrument TypeOnline TOC Analyzer
Oxidation MethodTwo-Stage Advanced Oxidation (TSAO) with Hydroxyl Radicals
Measurement PrincipleNDIR Detection of CO₂ after Acidification and Oxidation
Measurement Range (Standard)0–250 mgC/L
Extended Range (with Overrange Tracking)0–1,000 mgC/L
Accuracy±3% of reading or ±0.45 mgC/L (standard range)
RepeatabilitySame as accuracy specification
Detection LimitNot specified
ResolutionNot specified
Sample Particle Size Limit≤100 µm
Operating Temperature0–45 °C
Sample Inlet Temperature0–60 °C
Chloride ToleranceUp to 30% w/w
Humidity Range5–85% RH, non-condensing
Power Supply115/220 VAC
Dimensions (H×W×D)750 × 500 × 320 mm
Weight46 kg
Data Storage9,999 reaction records + 99 error logs
Communication ProtocolsModbus®, PROFIBUS
Cycle TimeTypically 7.5 minutes
Display40×16 LED-backlit LCD
LanguagesEnglish, Spanish, French (others on request)
Maintenance IntervalEvery 6 months
ComplianceEPA-approved oxidation method (U.S. Patent No. 6,623,974 B1)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Instrument TypeOnline TOC Analyzer
ModelAstro TOC UV TURBO
Measurement PrincipleUV-Persulfate Oxidation + NDIR Detection
Oxidation MethodDual-stage oxidation (acidic sparging for inorganic carbon removal followed by 185/254 nm UV photolysis with persulfate)
Measurement Range0–2.000, 0–5.000, 0–10.000, 0–25.000, 0–50.000 mg/L as C
Detection Limit≤5 µg/L (at 25°C, 0–5000 µg/L range)
Response TimeT₉₀ ≤ 5 min
Repeatability< ±2% RSD (at ≥100 µg/L)
Sample Flow Rate25–200 mL/min
Sample Temperature Range2–70°C
Operating Ambient Temperature5–40°C
Inlet Pressure0.15–6 bar
Enclosure RatingIP66 / NEMA 4
CertificationsCE, UL 61010-1, CSA C22.2 No. 61010-1
Dimensions (H×W×D)981 × 675 × 220 mm
Weight54 kg
Power Supply115/230 VAC, 50/60 Hz
Analog OutputsTwo isolated 4–20 mA outputs (user-configurable scaling)
Digital CommunicationRS232/RS485 (Modbus RTU or CSV format)
Alarm FunctionsFive configurable alarms (TOC concentration, system fault, maintenance due, flow loss, pressure deviation)
Carrier GasCO₂-free air or nitrogen (2.8–6.2 bar)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
ManufacturerHACH Company
ModelBIOTECTOR B3500e TOC
Instrument TypeOnline TOC Analyzer
Oxidation MethodTwo-Stage Advanced Oxidation (TSAO) using hydroxyl radicals
Measurement PrincipleNDIR detection of CO₂ after acidification and purge
Measurement Range (Standard)0–250 mg C/L
Extended Range (with Overrange Tracking)0–1,000 mg C/L
Accuracy±3% of reading or ±0.45 mg C/L (whichever is greater) for standard range
RepeatabilitySame as accuracy specification
Detection LimitNot specified
ResolutionNot specified
Sample Inlet Temperature0–60 °C
Operating Ambient Temperature0–45 °C
Relative Humidity5–85% non-condensing
Chloride ToleranceUp to 30% w/w
Particle Size Limit≤100 µm
Cycle TimeTypically 7.5 minutes
Data Storage9,999 reaction records + 99 error logs
Display40×16 high-contrast LED-backlit LCD
Communication ProtocolsModbus®, PROFIBUS
Power Supply115/220 VAC
Dimensions (H×W×D)750 × 500 × 320 mm
Weight46 kg
LanguagesEnglish, Spanish, French (others available on request)
Auto-CleaningIntegrated TSAO-based self-cleaning per cycle
CalibrationFully automated
TIC MeasurementAcidification + sparging prior to NDIR detection
TC MeasurementSum of TOC + TIC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ManufacturerHach Company
Product TypeOnline TOC Analyzer
Model8653700
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodUV/Persulfate with Optional Hydroxyl Radical Enhancement
Measurement Range0–100 µg C/L and 0–2000 µg C/L (Auto-Ranging)
Accuracy±10 µg C/L or ±3% of reading (whichever is greater)
Resolution0.001 ppb C
Detection Limit<10 µg C/L
Repeatability±10 µg C/L or ±2% of reading (whichever is greater)
Carrier Gas OptionsHigh-Purity Oxygen (for enhanced oxidation) or Instrument Air (for standard operation)
Sample PathwayIntegrated 4-mm ID flow cell, no pretreatment required
Reagent-Free OperationNo alkaline reagents used in CO₂ detection pathway