- All
- Favorite
- Popular
- Most rated
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR5000 |
| Instrument Architecture | Dual-Wavelength |
| Detector Type | CCD Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm (200–900 nm) |
| Spectral Bandwidth | 2 nm |
| Stray Light | < 0.05% T (KI solution at 220 nm) |
| Automation Level | Automatic Wavelength Selection & Calibration |
| Data Storage Capacity | 2000 measurement records with timestamp, sample ID, operator code, and method metadata |
| Interface | USB 1.1 (for PC connectivity, printer, keyboard, and firmware/data transfer) |
| Power Supply | 200–240 V, 50/60 Hz |
| Weight | 15.5 kg |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR3900 |
| Instrument Architecture | Dual-Beam |
| Detector Type | CCD Array |
| Wavelength Range | 320–1100 nm |
| Wavelength Accuracy | ±1.5 nm (340–900 nm) |
| Spectral Bandwidth | 5 nm |
| Stray Light | ≤0.001% T |
| Display | 7″ TFT WVGA Color Touchscreen (800 × 480 px) |
| Data Storage | 2000 Measurement Records |
| Preloaded Methods | >220 Standard Water Quality Methods |
| User-Defined Methods | Up to 100 |
| Barcode Recognition | Yes (Hach Predefined Reagents) |
| AQA Compliance Support | Yes |
| Connectivity | Ethernet, Dual USB Ports, Optional Printer Interface |
| Operating Environment | 10–40 °C, ≤80% RH (non-condensing) |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Dimensions | 151 × 350 × 255 mm |
| Weight | 4.2 kg |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR6000 |
| Optical Design | Pseudo-Double-Beam |
| Detector | CCD Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±1 nm (200–900 nm) |
| Stray Light | <3.3 Abs / <0.05% T (KI solution at 220 nm) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR/5000 |
| Optical Design | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm (200–900 nm) |
| Spectral Bandwidth | 2 nm |
| Wavelength Resolution | 0.1 nm |
| Stray Light | <0.05% T at 220 nm |
| Absorbance Range | ±3.0 ABS |
| Measurement Modes | Transmittance (%T), Absorbance (ABS), Concentration |
| Data Storage Capacity | 2000 data points with timestamp, sample ID, operator code, and result |
| Interface | USB 1.1 (to PC, printer, external keyboard) |
| Power Supply | 200–240 V, 50/60 Hz |
| Weight | 15.5 kg |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing) |
Show next