Empowering Scientific Discovery

Hach Company

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Instrument TypeOnline Analyzer
Detection PrinciplePhotometric (Colorimetric) Method
Detectable MetalsMulti-parameter (Cu, Fe, Ni, Mn, Cr, Zn, CN⁻)
Analysis Time10–15 min per cycle
Accuracy/Precision≤2% F.S. (using certified standard solutions)
Resolution<2%
Sample ProcessingIntegrated on-board digestion module (optional in EZ1000
Output4–20 mA analog output with alarm capability
CommunicationEthernet with Modbus TCP/IP support
Sample HandlingUp to 8-channel sequential sampling
Dilution CapabilityBuilt-in automatic sample dilution for extended dynamic range
Control InterfaceIndustrial-grade panel PC with embedded control software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Instrument TypeOnline Analyzer
Detection PrincipleMonochromatic Wavelength-Dispersive X-Ray Fluorescence (MWDXRF)
Target ElementsPb, As
Measurement TimeAutomatically selected between 10–50 minutes (10 min for high concentration
Detection LimitsPb: 0.005 mg/L
As0.001 mg/L
Analytical RangePb: 0.15–10 mg/L
As0.1–5 mg/L
Sample Flow Rate50–80 mL/min
Sample Pressure5–50 psi
Power Supply230 VAC ±10%, 50–60 Hz
Power Consumption400 VA
X-ray Tube50 kV / 1 mA, air-cooled, 50 W
RepeatabilityPb: 1.5% at 1 ppm
As1.8% at 0.5 ppm
Enclosure RatingIP53
CommunicationRS-485 (Modbus RTU)
Operating Temperature10–40 °C
Relative Humidity30–85 % RH
Dimensions (H×W×D)1040 × 600 × 437.16 mm
Relay Outputs2 channels, 220 V, 3 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Instrument TypeOnline Analyzer
Detection PrinciplePhotometric Colorimetry
Measurable MetalsCr(VI), Total Cr, Total Cu, Total Ni, Total Mn (Multi-Parameter Configurable)
Analysis Time25 min (Cr(VI))
Accuracy/Precision±3% F.S.
Resolution0.001 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelEZ6000 Trace Metals Analyzer
Instrument TypeOnline Analyzer
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Target AnalytesArsenic (As³⁺/Total As), and configurable for additional heavy metals (e.g., Cd, Pb, Cu, Zn)
Analysis Cycle Time≤ 40 minutes (including digestion, if integrated)
Accuracy/Precision±5% of full scale
Resolution≤ 1 µg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
ModelHach EZ Series (EZ1000 for Dissolved Metals / EZ2000 for Total Metals)
Instrument TypeOnline Analyzer
Detection PrincipleColorimetric Spectrophotometry (not ICP-OES — correction applied per technical accuracy)
Target MetalsCu, Fe, Ni, Mn, Cr, Zn (Dissolved and/or Total forms)
Accuracy/Precision≤2% F.S. (with certified standard solutions)
ResolutionAs specified in individual parameter datasheets
Sample ThroughputUp to 8-channel sequential analysis
Onboard DigestionIntegrated UV/persulfate digestion module (EZ2000 series only)
Output4–20 mA analog output with alarm thresholds
CommunicationModbus TCP/IP via Ethernet
Sample Volume per Analysis<15 mL
Optical Path LengthExtended (≥50 mm) for enhanced sensitivity
Control PlatformIndustrial-grade panel PC with embedded real-time OS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
ManufacturerHach Company
Instrument TypePortable
Detection PrincipleColorimetric Spectrophotometry
Measurable MetalsAs, Cr(Total), Cr(VI), Cu, Ni, Zn, Cd, Pb
Measurement Range (Typical)As 0–4000 ppb
Reagent Catalog Numbers2822800, 2242500, 1271099, 2105869, 2651600, 2429300, TNT852, TNT850
Kit ConfigurationsHM01 (DR2800 + battery + MP6P probe), HM02 (DR2800 + battery + H170NP pH/ORP probe + PHW77-SS stainless steel probe), HM03 (no DR2800, includes MP6P), HM04 (no DR2800, includes H170NP + PHW77-SS)
ComplianceDesigned for field use in accordance with EPA Method 200.7, ISO 11969, and ASTM D3559/D5191 for metals analysis in water
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0