Empowering Scientific Discovery

Hach Company

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ManufacturerHach Company
Product TypeImported
ModelCL17D Residual and Total Chlorine Analyzer – Distribution Network Version
Instrument TypeOnline Analyzer
Measurement PrincipleDPD Colorimetric Method (N,N-Diethyl-p-phenylenediamine)
Measured ParameterResidual Chlorine / Total Chlorine
Range0–5 mg/L as Cl₂
Accuracy±5% or ±0.005 mg/L as Cl₂ (whichever is greater)
Repeatability±0.035 mg/L or ±5% as Cl₂ (whichever is greater)
Detection Limit0.035 mg/L as Cl₂
Sample Temperature Range5–40 °C
Cycle Time10 minutes
Analog Output4–20 mA (configurable across 0–5 mg/L range)
Alarm OutputsTwo user-configurable concentration alarms, each with SPDT relay (5 A, 230 VAC)
Dimensions42 × 32 × 18 cm
Turbidity & Color CompensationAutomatic
CalibrationBuilt-in calibration curve
Diagnostic CapabilitySelf-diagnostic system
Reagent LifetimeUp to 120 days (unopened)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
ModelCLF10sc / CLT10sc
Instrument TypeLaboratory-Grade Analyzer
Measurement PrincipleAmperometric (Three-Electrode Electrochemical Detection)
Measured ParametersFree Chlorine, Total Chlorine
Measurement Range0–10 ppm
LOD≤30 ppb (0.030 ppm)
Resolution0.001 ppm (1 ppb)
Accuracy±3% for free chlorine
Repeatability±30 ppb or ±3%, whichever is greater
Operating Temperature0–45 °C (32–113 °F)
ComplianceEPA Method 334.0
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
ModelAccuChlor2
Instrument TypeOnline Analyzer
Measurement PrincipleAmperometric Electrochemical Sensor Method
Measured ParametersResidual Chlorine (Free & Total)
Sample Temperature Range0–49 °C
Flow Rate150–600 mL/min (recommended: 500 mL/min)
Sample pH Range3.0–10.0
Sample Alkalinity Range0.05–300 mg/L as CaCO₃
Sample Turbidity Limit< 252 NTU
Electrode MaterialsCathode – Gold
Buffer SolutionFor Free Chlorine – distilled 5% food-grade white vinegar
DisplayGraphical dot-matrix LCD (128 × 64 pixels), LED backlight, character height up to 13 mm
Measurement RangeAuto-ranging: 0–60.0 mg/L
Resolution0.001 mg/L (0–9.999 mg/L), 0.01 mg/L (10.0–60.0 mg/L)
Fixed-range mode0–60.0 mg/L, resolution 0.01 mg/L
Relay Outputs3 electromechanical relays
Analog OutputsTwo independent 4–20 mA outputs
Power Supply230 VAC ±10%, 50 Hz
Accuracy±0.1% of full scale
Sensitivity±0.05% of full scale
Repeatability±0.05% of full scale
Enclosure RatingNEMA 4X / IP65
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginUSA
ManufacturerHACH Company
Product TypeImported
ModelULR CL17 sc
Instrument CategoryOnline Analyzer
Measurement PrincipleDPD Colorimetric Method (ASTM D1253, ISO 7393-2)
Measured ParameterTotal Chlorine (as Cl₂)
Measurement Range0.008–5 mg/L Cl₂
Accuracy±5% or ±0.01 mg/L (whichever is greater) for 0–4 mg/L
Detection Limit0.008 mg/L Cl₂ at 25 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelCL17
Instrument TypeOnline Analyzer
Measurement PrincipleDPD Colorimetric Method (N,N-Diethyl-p-phenylenediamine)
Measured ParameterResidual Chlorine and Total Chlorine
Range0–5 mg/L as Cl₂
Accuracy±5% or ±0.035 mg/L as Cl₂ (whichever is greater)
Repeatability0.02 mg/L as Cl₂
Resolution0.001 mg/L as Cl₂
Detection Limit0.035 mg/L as Cl₂
Sample Temperature Range5–40 °C
Analog Output4–20 mA, scalable within 0–5 mg/L range
Alarm OutputsTwo user-configurable concentration alarms, each with SPDT relay (5 A, 230 VAC)
Dimensions42 mm (H) × 32 mm (W) × 18 mm (D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Model9187sc
Instrument TypeOnline Analyzer
Measurement PrincipleElectrochemical Amperometric Sensor
Measured ParameterClO₂ (Chlorine Dioxide)
Range0.010–2 ppm (mg/L) ClO₂
Accuracy±5% of reading or ±10 ppb ClO₂, whichever is greater
Repeatability0.02 mg/L
Resolution0.01 ppm
LOD10 ppb (0.01 mg/L) ClO₂
Response Time (t₉₀)<90 s
Sample Flow Rate200–250 mL/min
Operating Temperature0–45 °C
Sample Temperature Range0–45 °C
Storage Temperature−20 to 60 °C
Calibration IntervalEvery 2 months
Membrane & Electrolyte Replacement IntervalEvery 6 months
Inlet Connection1/4-in. O.D. tubing
Outlet Connection1/2-in. I.D. tubing
Enclosure RatingIP66 / NEMA 4X
Dimensions270 × 250 mm (10.63 × 9.84 in.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginUSA
ManufacturerHACH Company (a Danaher subsidiary)
Product TypeImported Online Analyzer
ModelCL17sc / CL17Dsc
Instrument CategoryOnline Residual & Total Chlorine Analyzer
Measurement PrincipleDPD Colorimetric Method (ASTM D1253, ISO 7393-2)
Measured ParameterFree Chlorine, Total Chlorine
Range0–10 mg/L as Cl₂
Accuracy±5% or ±0.04 mg/L (whichever is greater) for 0–5 mg/L
Detection Limit0.03 mg/L as Cl₂
Cycle Time2.5 min (standard) or 10 min (extended) per measurement
ComplianceDesigned to meet EPA 334.0, USP <643>, and WHO Guidelines for drinking water quality monitoring
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0