Empowering Scientific Discovery

Hach Company

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Instrument TypePortable
Measurement PrincipleIon-Selective Electrode (ISE)
Sensor ArchitectureIntegrated CARTRICAL Cartridge with pH, Temperature, and Selective Electrodes
CalibrationFactory-Calibrated Cartridge
Maintenance Interval~2x per year (typical operation)
Sample HandlingNo pretreatment required
Controller CompatibilitySC100 / SC200 / SC1000 Digital Controllers
Housing MaterialStainless Steel Body with Ryton End Caps
Immersion RatingFully Submersible
Mounting OptionsRod, Chain, or Wall-Mount Kits
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
ManufacturerHACH Company
ModelAmtax™ Compact
Instrument TypeOnline Analyzer
Measurement PrincipleGas-Phase Separation with Colorimetric Detection (Nesslerization-based)
Range Options0.2–12.0 mg/L NH₄–N
Accuracy±2.5% of reading or ±0.2 mg/L (whichever is greater, per certified standard solution)
Detection Limit0.5 mg/L NH₄–N
Cycle Time13–120 min (user-selectable)
Output Signals4–20 mA (max. load 500 Ω)
Digital InterfacesRS485 / RS232 with Modbus RTU or PROFIBUS DP protocol support
Alarm OutputsTwo programmable relay outputs (24 V DC, 1 A each)
Sample ChannelsDual-inlet capability (two independent sample streams)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Instrument TypeOnline Analyzer
Measurement PrincipleColorimetric Distillation Method
Measurement Range0.2–1200 mg/L NH₄–N
Accuracy≤ ±5% (varies by range
Detection Limit0.2 mg/L NH₄–N
Measurement IntervalUser-definable (13 min to 24 h)
Batch Capacity>10 samples per cycle
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Instrument TypeLaboratory
Measurement PrincipleIon-Selective Electrode (ISE) Method
Measurement Range0.2–1000 mg/L NH₄–N
Accuracy±5% of reading or ±0.2 mg/L (with certified standard solutions)
Detection Limit0.2 mg/L NH₄–N
Response Time (T90)<2 minutes
Sample Temperature Range0–40°C
Sample pH Range5–9
Immersion Depth0.3–3.0 m
Max Sample Pressure0.3 bar
Sensor Housing Material316 Stainless Steel with Ryton® end caps
Dimensions48 × 361 mm
Cable Length10 m (standard)
Weight1.3 kg
Operating CertificationsCE compliant
Warranty2 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
ManufacturerHach Company
ModelNH6000sc
Instrument TypeOnline Analyzer
Measurement PrincipleGas-Sensing Electrode (GSE)
Measurement Range0.02–5.0 mg/L NH₄–N (standard range), extendable to 10–1000 mg/L NH₄–N via range selection
Accuracy≤1 mg/L: ±0.02 mg/L + 3% of reading
>1 mg/L±0.02 mg/L + 5% of reading
Detection Limit0.02 mg/L NH₄–N
Response Time<5 minutes (for concentrations >0.2 mg/L)
Measurement IntervalUser-selectable (5, 10, 15, 20, or 30 min)
Sample Flow Rate1.0–20.0 L/h
Operating Temperature–20 to 45 °C
Enclosure RatingIP55 / NEMA 3R
Power Supply115 VAC or 230 VAC
Weight~45 kg
Dimensions575 × 991 × 425 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Instrument TypeOnline Analyzer
Measurement PrincipleIon-Selective Electrode (ISE) Method
Measurement Range0–1000 mg/L NH₄–N and 0–1000 mg/L K⁺
Accuracy±5% of reading + 0.2 mg/L
Measurement ModeContinuous Real-Time Monitoring
CalibrationBuilt-in Matrix Calibration with Auto-Compensation for Interfering Ions
Sensor ArchitectureIntegrated CARTRICAL™ Sensor Cartridge (K⁺-ISE, pH Reference Electrode, and Temperature Sensor in Single Housing)
Controller CompatibilityDigital SC Platform Integration
OptionalAutomated Cleaning Module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelAmtax NA8000
Instrument TypeOnline Analyzer
Measurement PrincipleSalicylate–Indophenol Blue Method
Measurement RangeNA8000.01: 0.020–160.0 mg/L (auto-ranging)
NA8000.020.020–1000 mg/L (auto-ranging with dilution)
Accuracy0.020–15.00 mg/L: ±(0.06 mg/L or 3%)
0.050–30.00 mg/L±(0.15 mg/L or 3%)
12.00–160.0 mg/L±(0.90 mg/L or 3%)
80.00–1000 mg/L±10%
Detection Limit0.02 mg/L
Measurement Cycle10–15 minutes
Repeatability≤2% (low range) to ≤3% (high range)
Display Resolution0.001 mg/L (≤9.999), 0.01 mg/L (10.00–99.99), 0.1 mg/L (100.0–999.9), 1 mg/L (≥1000)
Power Consumption100 W
Sampling Pressure0.04–1 bar (0.6–14.5 psi)
Sampling Flow Rate100–600 mL/min
Sampling Temperature5–40 °C
Operating Temperature5–40 °C
Relative Humidity≤95% RH (non-condensing)
Enclosure RatingIP55 (indoor use only)
Dimensions (L×W×H)455 × 365 × 805 mm
Weight~28 kg (excl. reagents)
Power Supply100–240 VAC, 50/60 Hz
Outputs2 × 24 VDC/3 A SPDT relays
Data Storage20,000 records
Event Log Capacity20,000 entries (retained for ≥2 years)
CalibrationAutomatic, manual, or remote-triggered
Sample Pretreatment CompatibilityCYQ-series water samplers (e.g., CYQ-106C, CYQ-104C)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0