Empowering Scientific Discovery

LECO Corporation

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelCS844
Measurement PrincipleInfrared Absorption
Heating SystemHigh-Frequency Induction Furnace
Carbon/Sulfur Range0.6 ppm – 6 wt%
Analysis Time< 50 seconds
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
ManufacturerLECO Corporation
TypeImported
ModelMSX255
Instrument CategoryMetallographic Cutting Machine
Blade Diameter300 mm (12 in)
Motor Power4 kW (5.4 HP)
SafetyInterlocked Guard with Automatic Shutdown
ControlManual Z-axis Lever, Manual X/Y Stage Adjustment
CoolingExternal Coolant Recovery Tank
EnclosureSealed Spindle Housing & Sealed Electronic Control Cabinet
IlluminationIntegrated LED Worklight
BrakingElectronic Brake System
StageT-slot Table (350 mm × 250 mm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelCitius HRT
Instrument TypeTime-of-Flight (TOF) Mass Spectrometer
Resolution100,000 (FWHM at m/z 500)
Acquisition Rate100–200 full-spectrum scans per second
Mass Accuracy< 1 ppb (rms, external calibration)
Dynamic Range10⁵–10⁶
Ion SourcesESI, APCI, DESI compatible
Flight Path Length64 m (folded via FFP™ technology)
Calibration ModesExternal standard, continuous internal standard, pseudo-external
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelH836EN
Instrument TypeHydrogen Analyzer
Detection Range0.01–100 ppm (w/w)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelTruTOF HT
Instrument TypeTime-of-Flight Mass Spectrometer (TOF-MS)
Acquisition Rate80 full-scan spectra/sec
Data Transfer Rate20,000 spectra/sec
Mass Rangem/z 5–1000
Resolution (FWHM)2000
Ionization ModesElectron Ionization (EI) and Chemical Ionization (CI) with rapid switching
Ion SourceField-serviceable design
Dynamic Signal TrackingYes
Quantitation LimitSub-pg level for target analytes
Regulatory ComplianceEPA-certified for environmental and food safety applications
Form FactorBenchtop
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
ManufacturerLECO Corporation
TypeHydrogen Analyzer
ModelRHEN602
Detection Range0.05 ppm – 500 ppm
Precision< 0.02 ppm
Sample CapacityUp to 6 g
Furnace TypeProgrammable Graphite Electrode Furnace
Calibration OptionsCertified Reference Materials (CRMs) and Standard Gases
ComplianceDesigned for GLP/GMP environments with audit-trail-capable software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
ManufacturerLECO Corporation
Instrument TypeGC-TOFMS
ModelPegasus HT
Mass Range5–1000 m/z
Sensitivity1 pg octafluoronaphthalene (OFN)
Acquisition Speed500 full spectra per second
DetectorMicrochannel Plate (MCP) Detector
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
ManufacturerLECO Corporation
Instrument TypeOxygen Bomb Calorimeter
Measurement ModeIsoperibol
Temperature Range0–80 °C
Temperature Resolution0.0001 °C
Precision≤0.10% RSD
Single-Sample Analysis Time≤5.5 min
Heat Capacity Calibration Range35,000 kJ/kg
Outer Water Jacket Volume12 L
Inner Water Bucket Volume6 L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelDH603
Instrument TypeHydrogen Analyzer
Measurement PrincipleThermal Extraction with Solid-State Detection
Temperature RangeAmbient to 1100 °C
Sample FormSolid Metallic Specimens (Ferrous Alloys, Weld Metals, Castings, Forgings)
Optional AccessoriesDiffusible Hydrogen Sampler, Residual Hydrogen Sampler, Vacuum Sampling Probes for Molten Metal
Calibration MethodStandardless Gas Calibration via Internal Reference Signal Stabilization
ComplianceDesigned to Support ASTM E1442, ISO 3690, AWS A4.3, and EN ISO 17025–accredited laboratory workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelSC832
Measurement PrincipleInfrared Absorption Spectroscopy
Heating SystemResistance Furnace
Measurement RangeC: 0.0175 mg to 200 mg
S0.0035 mg to 98 mg
Analysis Time< 100 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginGermany
ManufacturerLECO Corporation
Product TypeImported Instrument
ModelVC-50
Instrument CategoryPrecision Cutting Machine
Maximum Sample Diameter38 mm (1.5 in)
Blade Thickness Options0.25 mm or 0.36 mm
Rotational Speed Range0–500 rpm
Compatible Blade Diameters102 mm (4 in) or 127 mm (5 in)
Blade Material OptionsDiamond or Aluminum Oxide
Sample ClampingIntegrated Vise for ≤38 mm Samples
Feed MechanismManual Micrometer-Driven Slide with Counterweight Loading System
Safety FeatureAutomatic Shutdown
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelPegasus HRT
Instrument TypeTime-of-Flight Mass Spectrometer (TOF-MS)
Data Acquisition Rate200 full-spectrum scans/sec
Mass Resolution (Full Width at Half Maximum, FWHM)50,000 across full mass range
Mass Accuracy<100 ppb (external calibration, 3-day interval)
Dynamic Linear Range10⁵–10⁶
Ion Transmission Efficiency (Multi-Reflection Path)>80%
Effective Flight Path Length64 m
Calibration OptionsExternal standard, Continuous internal standard, Pseudo-external standard
SoftwareChromaTOF v5.2+ with TrueSignal™ Deconvolution, PeakFind™, Library Search (NIST, Wiley, LECO Custom)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
ManufacturerLECO Corporation
Instrument TypeDumas Combustion-Based Elemental Analyzer
Application FocusTotal Nitrogen, Protein, Carbon, Sulfur, and/or Oxygen Determination in Organic and Inorganic Matrices
Model FamilyTruSpec® Micro, TruSpec® Soil, TruSpec® CHN, TruSpec® CS, TruSpec® CNS (Configurable per application)
ComplianceASTM D5142, D6347/D6347M, D7329, ISO 13878, AOAC 992.15, 993.13, 2001.11, USP <467>, EPA Method 440.1, EN ISO 13878
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
ManufacturerLECO Corporation
TypeImported Instrument
ModelCS744
Measurement PrincipleInfrared Absorption
Heating SystemHigh-Frequency Induction Furnace
Analysis Time40 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeTime-of-Flight Mass Spectrometer (TOF-MS)
Chromatography TypeComprehensive Two-Dimensional Gas Chromatography (GC×GC)
Mass Rangem/z 1500
Sensitivity<1 fg (on-column, octadecane)
Scan Speed35,000 spectra/s
Detector ConfigurationDual Detection — High-Resolution TOF-MS + Flame Ionization Detector (FID) with Long-Life Design
ModelPegasus BT 4D MOSH/MOAH System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
ManufacturerLECO Corporation
TypeImported Instrument
ModelGCxGC
Application ScopeGeneral-Purpose
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelCHN828
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
ManufacturerLECO Corporation
TypeImported Instrument
ModelRC-612
Heating MethodInfrared
ComplianceAWS A4.3 / ANSI/AWS A4.3, ASTM E1019 (carbon), ASTM E203 (moisture), ISO 11722, ISO 11723
Optional Accessories50-position Autosampler, SmartLine® Remote Diagnostics, Analytical Balance Integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPegasus
Instrument TypeTime-of-Flight Mass Spectrometer (TOFMS)
AutosamplerCTC LEAP CombiPAL (Auto Headspace / Liquid / SPME)
Oven Temperature ControlLTM A68 with Range 0–400 °C and Ramp Rate ±1800 °C/min
Data Acquisition SpeedUp to 500 full-spectrum scans per second
SoftwareChromaTOF v5.x or later
Regulatory ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
ManufacturerLECO Corporation
TypeTube Furnace
ModelTF4
Maximum Temperature1350 °C
Temperature Control Accuracy±0.5 °C
Rated Power3520 W
Heating ElementSilicon Molybdenum (MoSi₂) Rods
Internal Chamber Dimensions69 cm (L) × 36 cm (W) × 72 cm (H)
Configuration Options2-Tube or 4-Tube Modular Arrangement
Primary ApplicationPre-conditioning of Ceramic Crucibles for Combustion-Based Elemental Analysis (C/S, O/N/H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
ManufacturerLECO Corporation
ModelPegasus GC-HRT 4D+
Instrument TypeTime-of-Flight Mass Spectrometer (TOF-MS)
Chromatography TypeComprehensive Two-Dimensional Gas Chromatography (GC×GC)
Mass Range15–1500 Da
Resolution25,000 / 50,000 (FWHM at m/z 200)
Sensitivity0.1 pg OFN (octafluoronaphthalene), S/N > 150 (UR model)
Acquisition Rate200 spectra/s
Ionization ModesElectron Impact (EI) and Chemical Ionization (CI)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelTC-500
Instrument TypeOxygen and Nitrogen Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
ManufacturerLECO Corporation
Product TypeImported Instrument
ModelAMH55
Instrument CategoryMicrohardness Tester
Measurement Range0–2000 HV (typical for Vickers microhardness)
Total Test Force1–60 kgf
Test Space (X × Y)260 × 150 mm
Automation LevelFully Automated / Semi-Automated / Lite Configurations Available
Software PlatformCornerstone® v5.0+
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLECO
OriginUSA
ManufacturerLECO Corporation
ModelO836Si
Instrument TypeOxygen Analyzer
Detection Range0.03–150 ppm
Analytical Precision±0.015 ppm
Analysis Time110 s
DetectorNon-Dispersive Solid-State Infrared (NDIR)
FurnaceProgrammable Pulse Electrode Furnace with Power & Current Control
Sample IntroductionFlip-Action Loading Port
Output Unitsppma and ppmw
Peak Separation MethodSurface Oxide vs. Bulk Oxide Quantification
Blank LevelUltra-Low Background
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0