| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CS844 |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace |
| Carbon/Sulfur Range | 0.6 ppm – 6 wt% |
| Analysis Time | < 50 seconds |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Imported |
| Model | MSX255 |
| Instrument Category | Metallographic Cutting Machine |
| Blade Diameter | 300 mm (12 in) |
| Motor Power | 4 kW (5.4 HP) |
| Safety | Interlocked Guard with Automatic Shutdown |
| Control | Manual Z-axis Lever, Manual X/Y Stage Adjustment |
| Cooling | External Coolant Recovery Tank |
| Enclosure | Sealed Spindle Housing & Sealed Electronic Control Cabinet |
| Illumination | Integrated LED Worklight |
| Braking | Electronic Brake System |
| Stage | T-slot Table (350 mm × 250 mm) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Citius HRT |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Resolution | 100,000 (FWHM at m/z 500) |
| Acquisition Rate | 100–200 full-spectrum scans per second |
| Mass Accuracy | < 1 ppb (rms, external calibration) |
| Dynamic Range | 10⁵–10⁶ |
| Ion Sources | ESI, APCI, DESI compatible |
| Flight Path Length | 64 m (folded via FFP™ technology) |
| Calibration Modes | External standard, continuous internal standard, pseudo-external |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | H836EN |
| Instrument Type | Hydrogen Analyzer |
| Detection Range | 0.01–100 ppm (w/w) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TruTOF HT |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Acquisition Rate | 80 full-scan spectra/sec |
| Data Transfer Rate | 20,000 spectra/sec |
| Mass Range | m/z 5–1000 |
| Resolution (FWHM) | 2000 |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) with rapid switching |
| Ion Source | Field-serviceable design |
| Dynamic Signal Tracking | Yes |
| Quantitation Limit | Sub-pg level for target analytes |
| Regulatory Compliance | EPA-certified for environmental and food safety applications |
| Form Factor | Benchtop |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Hydrogen Analyzer |
| Model | RHEN602 |
| Detection Range | 0.05 ppm – 500 ppm |
| Precision | < 0.02 ppm |
| Sample Capacity | Up to 6 g |
| Furnace Type | Programmable Graphite Electrode Furnace |
| Calibration Options | Certified Reference Materials (CRMs) and Standard Gases |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | GC-TOFMS |
| Model | Pegasus HT |
| Mass Range | 5–1000 m/z |
| Sensitivity | 1 pg octafluoronaphthalene (OFN) |
| Acquisition Speed | 500 full spectra per second |
| Detector | Microchannel Plate (MCP) Detector |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Isoperibol |
| Temperature Range | 0–80 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ≤0.10% RSD |
| Single-Sample Analysis Time | ≤5.5 min |
| Heat Capacity Calibration Range | 35,000 kJ/kg |
| Outer Water Jacket Volume | 12 L |
| Inner Water Bucket Volume | 6 L |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DH603 |
| Instrument Type | Hydrogen Analyzer |
| Measurement Principle | Thermal Extraction with Solid-State Detection |
| Temperature Range | Ambient to 1100 °C |
| Sample Form | Solid Metallic Specimens (Ferrous Alloys, Weld Metals, Castings, Forgings) |
| Optional Accessories | Diffusible Hydrogen Sampler, Residual Hydrogen Sampler, Vacuum Sampling Probes for Molten Metal |
| Calibration Method | Standardless Gas Calibration via Internal Reference Signal Stabilization |
| Compliance | Designed to Support ASTM E1442, ISO 3690, AWS A4.3, and EN ISO 17025–accredited laboratory workflows |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SC832 |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | Resistance Furnace |
| Measurement Range | C: 0.0175 mg to 200 mg |
| S | 0.0035 mg to 98 mg |
| Analysis Time | < 100 s |
| Brand | LECO |
|---|---|
| Origin | Germany |
| Manufacturer | LECO Corporation |
| Product Type | Imported Instrument |
| Model | VC-50 |
| Instrument Category | Precision Cutting Machine |
| Maximum Sample Diameter | 38 mm (1.5 in) |
| Blade Thickness Options | 0.25 mm or 0.36 mm |
| Rotational Speed Range | 0–500 rpm |
| Compatible Blade Diameters | 102 mm (4 in) or 127 mm (5 in) |
| Blade Material Options | Diamond or Aluminum Oxide |
| Sample Clamping | Integrated Vise for ≤38 mm Samples |
| Feed Mechanism | Manual Micrometer-Driven Slide with Counterweight Loading System |
| Safety Feature | Automatic Shutdown |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Pegasus HRT |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Data Acquisition Rate | 200 full-spectrum scans/sec |
| Mass Resolution (Full Width at Half Maximum, FWHM) | 50,000 across full mass range |
| Mass Accuracy | <100 ppb (external calibration, 3-day interval) |
| Dynamic Linear Range | 10⁵–10⁶ |
| Ion Transmission Efficiency (Multi-Reflection Path) | >80% |
| Effective Flight Path Length | 64 m |
| Calibration Options | External standard, Continuous internal standard, Pseudo-external standard |
| Software | ChromaTOF v5.2+ with TrueSignal™ Deconvolution, PeakFind™, Library Search (NIST, Wiley, LECO Custom) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | Dumas Combustion-Based Elemental Analyzer |
| Application Focus | Total Nitrogen, Protein, Carbon, Sulfur, and/or Oxygen Determination in Organic and Inorganic Matrices |
| Model Family | TruSpec® Micro, TruSpec® Soil, TruSpec® CHN, TruSpec® CS, TruSpec® CNS (Configurable per application) |
| Compliance | ASTM D5142, D6347/D6347M, D7329, ISO 13878, AOAC 992.15, 993.13, 2001.11, USP <467>, EPA Method 440.1, EN ISO 13878 |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Imported Instrument |
| Model | CS744 |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace |
| Analysis Time | 40 s |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Chromatography Type | Comprehensive Two-Dimensional Gas Chromatography (GC×GC) |
| Mass Range | m/z 1500 |
| Sensitivity | <1 fg (on-column, octadecane) |
| Scan Speed | 35,000 spectra/s |
| Detector Configuration | Dual Detection — High-Resolution TOF-MS + Flame Ionization Detector (FID) with Long-Life Design |
| Model | Pegasus BT 4D MOSH/MOAH System |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Imported Instrument |
| Model | GCxGC |
| Application Scope | General-Purpose |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CHN828 |
| Pricing | Upon Request |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Imported Instrument |
| Model | RC-612 |
| Heating Method | Infrared |
| Compliance | AWS A4.3 / ANSI/AWS A4.3, ASTM E1019 (carbon), ASTM E203 (moisture), ISO 11722, ISO 11723 |
| Optional Accessories | 50-position Autosampler, SmartLine® Remote Diagnostics, Analytical Balance Integration |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Pegasus |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOFMS) |
| Autosampler | CTC LEAP CombiPAL (Auto Headspace / Liquid / SPME) |
| Oven Temperature Control | LTM A68 with Range 0–400 °C and Ramp Rate ±1800 °C/min |
| Data Acquisition Speed | Up to 500 full-spectrum scans per second |
| Software | ChromaTOF v5.x or later |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Tube Furnace |
| Model | TF4 |
| Maximum Temperature | 1350 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Rated Power | 3520 W |
| Heating Element | Silicon Molybdenum (MoSi₂) Rods |
| Internal Chamber Dimensions | 69 cm (L) × 36 cm (W) × 72 cm (H) |
| Configuration Options | 2-Tube or 4-Tube Modular Arrangement |
| Primary Application | Pre-conditioning of Ceramic Crucibles for Combustion-Based Elemental Analysis (C/S, O/N/H) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Model | Pegasus GC-HRT 4D+ |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Chromatography Type | Comprehensive Two-Dimensional Gas Chromatography (GC×GC) |
| Mass Range | 15–1500 Da |
| Resolution | 25,000 / 50,000 (FWHM at m/z 200) |
| Sensitivity | 0.1 pg OFN (octafluoronaphthalene), S/N > 150 (UR model) |
| Acquisition Rate | 200 spectra/s |
| Ionization Modes | Electron Impact (EI) and Chemical Ionization (CI) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TC-500 |
| Instrument Type | Oxygen and Nitrogen Analyzer |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Product Type | Imported Instrument |
| Model | AMH55 |
| Instrument Category | Microhardness Tester |
| Measurement Range | 0–2000 HV (typical for Vickers microhardness) |
| Total Test Force | 1–60 kgf |
| Test Space (X × Y) | 260 × 150 mm |
| Automation Level | Fully Automated / Semi-Automated / Lite Configurations Available |
| Software Platform | Cornerstone® v5.0+ |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Model | O836Si |
| Instrument Type | Oxygen Analyzer |
| Detection Range | 0.03–150 ppm |
| Analytical Precision | ±0.015 ppm |
| Analysis Time | 110 s |
| Detector | Non-Dispersive Solid-State Infrared (NDIR) |
| Furnace | Programmable Pulse Electrode Furnace with Power & Current Control |
| Sample Introduction | Flip-Action Loading Port |
| Output Units | ppma and ppmw |
| Peak Separation Method | Surface Oxide vs. Bulk Oxide Quantification |
| Blank Level | Ultra-Low Background |