- All
- Favorite
- Popular
- Most rated
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CS844 |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace |
| Carbon/Sulfur Range | 0.6 ppm – 6 wt% |
| Analysis Time | < 50 seconds |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Citius HRT |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Resolution | 100,000 (FWHM at m/z 500) |
| Acquisition Rate | 100–200 full-spectrum scans per second |
| Mass Accuracy | < 1 ppb (rms, external calibration) |
| Dynamic Range | 10⁵–10⁶ |
| Ion Sources | ESI, APCI, DESI compatible |
| Flight Path Length | 64 m (folded via FFP™ technology) |
| Calibration Modes | External standard, continuous internal standard, pseudo-external |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | H836EN |
| Instrument Type | Hydrogen Analyzer |
| Detection Range | 0.01–100 ppm (w/w) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TruTOF HT |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Acquisition Rate | 80 full-scan spectra/sec |
| Data Transfer Rate | 20,000 spectra/sec |
| Mass Range | m/z 5–1000 |
| Resolution (FWHM) | 2000 |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) with rapid switching |
| Ion Source | Field-serviceable design |
| Dynamic Signal Tracking | Yes |
| Quantitation Limit | Sub-pg level for target analytes |
| Regulatory Compliance | EPA-certified for environmental and food safety applications |
| Form Factor | Benchtop |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Hydrogen Analyzer |
| Model | RHEN602 |
| Detection Range | 0.05 ppm – 500 ppm |
| Precision | < 0.02 ppm |
| Sample Capacity | Up to 6 g |
| Furnace Type | Programmable Graphite Electrode Furnace |
| Calibration Options | Certified Reference Materials (CRMs) and Standard Gases |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | GC-TOFMS |
| Model | Pegasus HT |
| Mass Range | 5–1000 m/z |
| Sensitivity | 1 pg octafluoronaphthalene (OFN) |
| Acquisition Speed | 500 full spectra per second |
| Detector | Microchannel Plate (MCP) Detector |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DH603 |
| Instrument Type | Hydrogen Analyzer |
| Measurement Principle | Thermal Extraction with Solid-State Detection |
| Temperature Range | Ambient to 1100 °C |
| Sample Form | Solid Metallic Specimens (Ferrous Alloys, Weld Metals, Castings, Forgings) |
| Optional Accessories | Diffusible Hydrogen Sampler, Residual Hydrogen Sampler, Vacuum Sampling Probes for Molten Metal |
| Calibration Method | Standardless Gas Calibration via Internal Reference Signal Stabilization |
| Compliance | Designed to Support ASTM E1442, ISO 3690, AWS A4.3, and EN ISO 17025–accredited laboratory workflows |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SC832 |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | Resistance Furnace |
| Measurement Range | C: 0.0175 mg to 200 mg |
| S | 0.0035 mg to 98 mg |
| Analysis Time | < 100 s |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Pegasus HRT |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Data Acquisition Rate | 200 full-spectrum scans/sec |
| Mass Resolution (Full Width at Half Maximum, FWHM) | 50,000 across full mass range |
| Mass Accuracy | <100 ppb (external calibration, 3-day interval) |
| Dynamic Linear Range | 10⁵–10⁶ |
| Ion Transmission Efficiency (Multi-Reflection Path) | >80% |
| Effective Flight Path Length | 64 m |
| Calibration Options | External standard, Continuous internal standard, Pseudo-external standard |
| Software | ChromaTOF v5.2+ with TrueSignal™ Deconvolution, PeakFind™, Library Search (NIST, Wiley, LECO Custom) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | Dumas Combustion-Based Elemental Analyzer |
| Application Focus | Total Nitrogen, Protein, Carbon, Sulfur, and/or Oxygen Determination in Organic and Inorganic Matrices |
| Model Family | TruSpec® Micro, TruSpec® Soil, TruSpec® CHN, TruSpec® CS, TruSpec® CNS (Configurable per application) |
| Compliance | ASTM D5142, D6347/D6347M, D7329, ISO 13878, AOAC 992.15, 993.13, 2001.11, USP <467>, EPA Method 440.1, EN ISO 13878 |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Imported Instrument |
| Model | CS744 |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace |
| Analysis Time | 40 s |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Chromatography Type | Comprehensive Two-Dimensional Gas Chromatography (GC×GC) |
| Mass Range | m/z 1500 |
| Sensitivity | <1 fg (on-column, octadecane) |
| Scan Speed | 35,000 spectra/s |
| Detector Configuration | Dual Detection — High-Resolution TOF-MS + Flame Ionization Detector (FID) with Long-Life Design |
| Model | Pegasus BT 4D MOSH/MOAH System |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Imported Instrument |
| Model | GCxGC |
| Application Scope | General-Purpose |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CHN828 |
| Pricing | Upon Request |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Imported Instrument |
| Model | RC-612 |
| Heating Method | Infrared |
| Compliance | AWS A4.3 / ANSI/AWS A4.3, ASTM E1019 (carbon), ASTM E203 (moisture), ISO 11722, ISO 11723 |
| Optional Accessories | 50-position Autosampler, SmartLine® Remote Diagnostics, Analytical Balance Integration |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Pegasus |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOFMS) |
| Autosampler | CTC LEAP CombiPAL (Auto Headspace / Liquid / SPME) |
| Oven Temperature Control | LTM A68 with Range 0–400 °C and Ramp Rate ±1800 °C/min |
| Data Acquisition Speed | Up to 500 full-spectrum scans per second |
| Software | ChromaTOF v5.x or later |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Model | Pegasus GC-HRT 4D+ |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Chromatography Type | Comprehensive Two-Dimensional Gas Chromatography (GC×GC) |
| Mass Range | 15–1500 Da |
| Resolution | 25,000 / 50,000 (FWHM at m/z 200) |
| Sensitivity | 0.1 pg OFN (octafluoronaphthalene), S/N > 150 (UR model) |
| Acquisition Rate | 200 spectra/s |
| Ionization Modes | Electron Impact (EI) and Chemical Ionization (CI) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TC-500 |
| Instrument Type | Oxygen and Nitrogen Analyzer |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Model | O836Si |
| Instrument Type | Oxygen Analyzer |
| Detection Range | 0.03–150 ppm |
| Analytical Precision | ±0.015 ppm |
| Analysis Time | 110 s |
| Detector | Non-Dispersive Solid-State Infrared (NDIR) |
| Furnace | Programmable Pulse Electrode Furnace with Power & Current Control |
| Sample Introduction | Flip-Action Loading Port |
| Output Units | ppma and ppmw |
| Peak Separation Method | Surface Oxide vs. Bulk Oxide Quantification |
| Blank Level | Ultra-Low Background |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOFMS) |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 10–1500 Da |
| Resolution | 2500 (FWHM at m/z 502) |
| IDL | <8 fg Octafluoronaphthalene (OFN) |
| Acquisition Speed | 50,000,000 amu/s |
| Dynamic Linear Range | >6 orders of magnitude |
| Ion Source | Stay Clean™ Self-Cleaning Electron Ionization Source |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ON736 |
| Analysis Time | 85 s |
| Detection Principle | Inert Gas Fusion Coupled with Non-Dispersive Infrared (NDIR) and Thermal Conductivity Detection (TCD) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | GC×GC-TOFMS |
| Model | Pegasus 4D |
| Mass Range | 5–1000 m/z |
| Sensitivity | >100:1 S/N for 1 pg octafluoronaphthalene (OFN) under full-spectrum, high-speed acquisition |
| Acquisition Rate | 500 spectra/sec (5000 Hz) |
| Detector | Dual Microchannel Plate (MCP) Detector |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Imported Instrument |
| Model | TGM800 |
| Pricing | Available Upon Request |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | FP628 |
| Instrument Principle | Dumas Combustion Method |
| Analysis Time | 4.5 min per sample |
| Nitrogen Range | 0.04–50 mg absolute |
| Precision | ±0.02 mg or 0.5% RSD (whichever is greater) |
| Sample Mass | up to 750 mg (typical 500 mg) |
| Readability | 0.0001% w/w |
| Detector | Thermal Conductivity (TC) Cell |
| Carrier Gas | Helium (99.99%, 35 psi ±10%) |
| Combustion Gas | Oxygen (99.99%, 35 psi ±10%) |
| Assist Gas | Oil-free, dry compressed air (40 psi ±10%) |
| Furnace Temp | Primary furnace up to 950 °C, secondary furnace up to 1050 °C |
| Autosampler | 30-position (expandable to 120 via stacking) |
| Dimensions | 81 × 70 × 76 cm (H×W×D) |
| Weight | 124 kg (net), 147 kg (shipping) |
| Power | 230 V AC ±10%, 50/60 Hz, single-phase, 12 A, 4000 BTU/hr cooling requirement |
| Compliance | ASTM D515, ISO 14891, AOAC 992.15, USP <282>, FDA 21 CFR Part 11 ready (with optional audit trail module) |
Show next