Optical Measurement Instruments
Filter
Showing 2881–2910 of 3895 results
| Brand | Phasics |
|---|---|
| Origin | France |
| Model | SID4-NIR |
| Aperture | 3.6 × 4.8 mm² |
| Spatial Resolution | 29.6 µm |
| Sampling Points | 160 × 120 |
| Wavelength Range | 1.5–1.6 µm |
| Dynamic Range | > 200 µm |
| Accuracy | > 15 nm RMS |
| Sensitivity | < 1 nm RMS (low-gain mode) |
| Frame Rate | 60 fps |
| Processing Rate | 10 Hz (high-resolution mode) |
| Dimensions | 44 × 33 × 57.5 mm |
| Weight | 250 g |
| Brand | Phasics |
|---|---|
| Model | SID4-UHR |
| Wavelength Range | 400–1100 nm |
| Active Aperture | 15 × 15 mm² |
| Spatial Resolution | 29.6 µm |
| Phase Sampling Resolution | 512 × 512 (optional up to 666 × 666) |
| Phase Resolution | 2 nm RMS |
| Absolute Accuracy | 15 nm RMS |
| Frame Rate | 8 fps (raw data), 1 fps (full-resolution real-time processing) |
| Chromatic Correction | Achromatic, non-collimated beam compatible |
| Brand | Phasics |
|---|---|
| Model | SID4-UV-HR |
| Wavelength Range | 190–400 nm |
| Active Area | 13.8 × 10.88 mm² |
| Spatial Resolution | 38.88 µm |
| Sampling Resolution | 355 × 280 pixels |
| Phase Sensitivity | 1 nm RMS |
| Absolute Accuracy | 10 nm RMS |
| Frame Rate | 30 fps |
| Real-Time Processing Speed | >3 fps (full resolution) |
| Interface | CameraLink |
| Brand | Phasics |
|---|---|
| Origin | France |
| Model | SID4-V |
| Vacuum Compatibility | < 10⁻⁶ mbar |
| Wavelength Range | 400–1100 nm |
| Aperture | 4.73 × 3.55 mm² |
| Phase Sampling | 160 × 120 points (>19,000) |
| Spatial Resolution | 29.6 µm |
| Phase Accuracy | 15 nm RMS |
| Phase Sensitivity | <2 nm RMS |
| Dynamic Range | >100 µm |
| Frame Rate | ≥60 fps (acquisition), ≥7 Hz (full-resolution real-time processing) |
| Interface | Gigabit Ethernet |
| Dimensions | 54 × 46 × 75.3 mm |
| Weight | ~250 g |
| Brand | Photonic Lattice |
|---|---|
| Origin | Japan |
| Model | PA-200-L |
| Measurement Principle | Full-field photoelastic imaging using photonic crystal polarizer array |
| Wavelength | 520 nm |
| Birefringence Range | 0–130 nm |
| Minimum Resolution | 0.001 nm |
| Repeatability | < 0.1 nm (σ) |
| Field of View (Standard) | 27 × 36 mm to 99 × 132 mm |
| Optional FOV (with beam-expanding lens) | down to 7 × 8.4 mm |
| Camera Resolution | 2056 × 2464 pixels |
| Output Parameters | Retardation (nm), Fast Axis Orientation (°), Stress Conversion (MPa, optional) |
| Software Options | Real-time analysis module, Lens-specific analysis suite, External control interface (TCP/IP, LabVIEW SDK) |
| Key | Brand: Photonic Lattice |
|---|---|
| Origin | Japan |
| Model | PA-300 |
| Measurement Range | 0–130 nm (retardation) |
| Wavelength | 520 nm |
| Minimum Resolution | 0.001 nm |
| Repeatability | < 0.1 nm (σ) |
| Field of View (Standard) | 27 × 36 mm to 99 × 132 mm |
| Optional FOV (with beam-expanding lens) | 7 × 8.4 mm |
| Camera Resolution | 2056 × 2464 pixels |
| Output Parameters | Retardation (nm), Fast Axis Orientation (°), Stress Conversion (MPa, optional) |
| Compliance | ISO 11146, ASTM F2649, JIS R3203 |
| Brand | Photonic Lattice |
|---|---|
| Origin | Japan |
| Model | PA-micro |
| Measurement Range | 0–130 nm |
| Repeatability | <1.0 nm |
| Pixel Resolution | 1120 × 868 |
| Wavelength | 520 nm |
| Objective Lenses | 5× (1.1 × 0.8 mm), 10× (0.5 × 0.4 mm), 20× (270 × 200 µm), 50× (110 × 80 µm), 100× (55 × 40 µm) |
| Dimensions | 250 × 487 × 690 mm |
| Weight | 11 kg |
| Interface | Gigabit Ethernet (camera signal) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Software | PA-View (for Micro) |
| Brand | Photonic Lattice |
|---|---|
| Origin | Japan |
| Model | Ultra-Large-Area WPA |
| Wavelengths | 523 nm, 543 nm, 575 nm |
| Retardation Measurement Range | up to 3500 nm |
| Optical Configuration | Custom-engineered wide-aperture circular polarized light source + wide-angle polarization-sensitive area sensor |
| Application Focus | In-line and lab-based birefringence/residual stress assessment of automotive laminated glass, architectural glazing, and large-format optical substrates |
| Brand | Photonic Lattice |
|---|---|
| Origin | Japan |
| Model | WPA-200-L |
| Measurement Principle | Quantitative Full-Field Retardation Imaging via Polarized Light Interference |
| Max. Retardation Range | 0–3500 nm |
| Wavelength Options | 520 nm, 543 nm, 575 nm |
| Spatial Resolution (Retardation) | 0.001 nm |
| Repeatability (σ) | <1 nm |
| Standard FOV | 33 × 40 mm to 240 × 320 mm |
| Optional Micro-FOV Lenses | 3 × 4 mm to 12.9 × 17.2 mm |
| Output Data | Retardation (nm), Slow Axis Orientation (°), Stress Conversion (MPa, optional) |
| Software Modules | Real-Time Analysis, Lens-Specific Evaluation, Batch Data Processing, External Trigger Control |
| Compliance | Designed for ISO 11476 (Optical Elements — Birefringence Measurement), ASTM F2730 (Plastic Optical Components), and GLP-aligned data audit trails |
| Brand | Photonic Lattice |
|---|---|
| Origin | Japan |
| Model | WPA-200-XL |
| Measurement Principle | Full-field photoelastic imaging at multiple wavelengths |
| Output | Retardation (nm), Fast-axis orientation (°), Stress-equivalent birefringence (MPa, optional) |
| Wavelengths | 520 nm, 543 nm, 575 nm |
| Birefringence Range | 0–3500 nm |
| Resolution | 0.001 nm |
| Repeatability | <0.1 nm (σ) |
| Field of View | 218 × 290 mm to 360 × 480 mm (standard) |
| Imaging Sensor | High-sensitivity CCD camera |
| Software Options | Real-time analysis module, Lens-specific evaluation suite, External control interface, CD-mode measurement mode |
| Compliance | Designed for ISO 11477 (plastics — determination of birefringence), ASTM D4093 (optical properties of transparent plastics), and GLP-aligned data integrity workflows |
| Brand | Photek |
|---|---|
| Origin | USA |
| Model | ILCI-25 |
| Image Intensifier Type | MCP125 (single-stage) or MCP225 (dual-stage) |
| Effective Aperture | 25 mm |
| Input Window | Fused Silica (optional MgF₂) |
| Photocathode Types | Solar Blind, Bialkali, LNS20, S20, S25 |
| MCP Diameter | 25 mm |
| Output Window | Fiber Optic Faceplate |
| Phosphor Screen | P43 (optional) |
| Resolution | 32 lp/mm (MCP125), 23 lp/mm (MCP225) |
| Gain | 10⁴ W/W (MCP125), 10⁶ W/W (MCP225, single-photon capable) |
| Gating Speed | 5 ns minimum gate width |
| Timing Jitter | ±2.5 ns |
| Optical Input Interface | Nikon F-Mount |
| Output Mount | 52 mm diameter lens thread |
| Integrated Lens | 50 mm f/1.2 |
| Minimum Delay | 50 ns |
| Delay/Gate Resolution | 5 ns |
| Gain Control | 12-bit DAC |
| Anode Current Protection Thresholds | 200 nA, 400 nA, 600 nA, 800 nA, 1 µA |
| Trigger Input | 50 Ω, rising/falling edge, up to 100 kHz |
| Trigger Sources | External TTL input or internal timebase |
| Control Interface | Micro-USB, touchscreen LCD (100 × 58 mm), optical encoder |
| Housing | Aluminum alloy |
| Dimensions (L×W×H) | 145 × 90 × 115 mm (excl. mounts/lenses) |
| Weight | <2 kg |
| Power Supply | +12 VDC @ 2 A max (external adapter included) |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LiNbO3_EO_Intensity_Modulator |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LiNbO3_EO_Phase_Modulator |
| Pricing | Available Upon Request |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | A-TAKT |
| Type | CCD-based spectroradiometer |
| Spectral Bandwidth Options | 2 nm, 5 nm, 8 nm |
| Field-of-View Apertures | 0.50°, 1.0°, 1.25°, 1.50° |
| Lens Options | Fixed-focus 50 mm or zoom 75 mm |
| Stray-light Suppression | Optional shielded brightness accessory |
| Mounting Interface | 1/4"-20 SAE threaded port |
| Communication Interfaces | USB 2.0, RS-232 |
| OS Compatibility | Windows Vista (32/64-bit) and later, macOS 10.7+ |
| SDK Available | Yes, C/C++, .NET, LabVIEW compatible |
| Compliance Support | ASTM E308, CIE 15:2018, ISO/CIE 11664, IEC 62369-1, FDA 21 CFR Part 11 (audit trail via software logging) |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | V-5HSC |
| Detection Principle | Filter-based tristimulus photometry conforming to CIE 1931 2° standard observer |
| Luminance Range | 0.01 to 6,000 cd/m² |
| Dynamic Range | 60,000:1 |
| Measurement Speed | Up to 30 readings per second |
| Spectral Matching f₁′ (CIE X/Y/Z) | 3.4% / 3.2% / 3.4% |
| Interface | RS232 with ASCII command protocol |
| Flicker Measurement | JEITA-compliant (built-in, no add-on required) |
| Display | Integrated high-contrast OLED screen |
| Power | Rechargeable Li-ion battery (≥8 hrs continuous operation) |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | CINEBRATE |
| Wavelength Range | 380–780 nm |
| Detector | 126-element linear array |
| Lens | Fixed-focus 75 mm |
| Focusing Distance | 3–30 m |
| Target Acquisition | Integrated laser alignment system |
| Measurement Spot Size | 99–987 mm (at specified distance) |
| Integration Time | 3 ms – 30 s |
| Spectral Bandwidth | 5 nm |
| Spectral Resolution | 4 nm |
| Luminance Range | 0.171–171 cd/m² |
| Luminance Accuracy (NIST-traceable) | ±2% @ 3.43 cd/m² |
| Luminance Repeatability | <1% @ 3.43 cd/m² |
| Chromaticity Accuracy (CIE Standard Illuminant A) | ±0.0015 CIEx,y @ 3.43 cd/m² |
| Chromaticity Repeatability | ±0.0015 CIEx,y @ 3.43 cd/m² |
| Frame Synchronization Frequency | 20–400 Hz |
| Field of View | 2° |
| Power Supply | Rechargeable Li-ion battery or AC adapter |
| Data Interface | USB 2.0 |
| Display | 640×480 full-color touchscreen LCD |
| Dimensions | 335.6 × 201.7 × 81.5 mm |
| Weight | 1.7 kg |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-521 |
| Type | Automatic |
| Illuminance Range | 0.01–999,999 lx |
| Luminance Range | 0.001–999,999 cd/m² |
| Chromaticity Accuracy | ±0.002 in CIE 1931 xy |
| Correlated Color Temperature (CCT) Range | 1000–100,000 K |
| Display | Backlit capacitive touchscreen |
| Data Storage | SD card (up to 52,000 measurements) |
| Interface | USB 2.0 |
| Battery | Rechargeable Li-ion, 6 hours continuous operation |
| Compliance | NIST-traceable calibration, ISO/CIE-compliant photometric geometry |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-655 |
| Spectral Range | 380–780 nm |
| Detector Array | 128-element CCD |
| Spectral Resolution | 3.12 nm/pixel |
| Standard Aperture | 1° |
| Optional Apertures | 0.5° |
| Auto-Synchronization | Yes (to source refresh rate) |
| Data Storage | SD card |
| Interface | USB 2.0, Bluetooth (optional), RS-232 emulation via driver |
| Battery Life | Up to 12 hours (rechargeable Li-ion) |
| Display | 2.25" × 3" full-color touchscreen |
| Measurement Modes | Luminance, Illuminance, Radiance, Irradiance, Chromaticity (CIE x,y & u',v'), CCT, Duv, CRI (Ra, R1–R14), Dominant Wavelength, Purity, Spectral Power Distribution (SPD) |
| Remote Probe Support | Up to 15 filter-based probes (luminance, illuminance, or colorimetric) |
| Compliance | NIST-traceable calibration, ISO/IEC 17025-accredited calibration services available |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-655 |
| Spectral Resolution | 3.12 nm/pixel |
| Detector Array | 128-element CCD |
| Standard Aperture | 1° |
| Optional Apertures | 0.5° |
| Measurement Modes | Luminance, Radiance, Illuminance, Chromaticity, CCT, CRI, Dominant Wavelength, SPD |
| Sync Capability | AutoSync with AC mains or source flicker frequency |
| Interface | USB 2.0, Bluetooth (optional), RS-232 (via emulator driver) |
| Data Storage | SD card (included) |
| Power | Rechargeable Li-ion battery (≥12 h continuous operation) |
| Display | 2.25" × 3" full-color touchscreen + 5-way keypad |
| Compliance | NIST-traceable calibration, ISO/IEC 17025–accredited calibration labs |
| Brand | Photo Research |
|---|---|
| Model | PR-670 |
| Spectral Resolution | 1.56 nm/pixel |
| Detector Array | 256-element CCD |
| Apertures | 1°, 0.5°, 0.25°, 0.125° (motorized) |
| Display | 2.25" × 3" full-color touchscreen |
| Battery Life | up to 12 hours (rechargeable Li-ion) |
| Data Storage | SD card (thousands of spectra) |
| Interface | USB 2.0, Bluetooth (optional), RS-232 emulation (driver-supported) |
| Sync | AutoSync for flicker-free measurement at variable refresh rates |
| Remote Trigger | TTL-compatible input |
| Compliance | CIE 127, ISO/CIE 11664, ASTM E308, USP <1033>, GLP/GMP-ready data logging |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-680L |
| Power Supply | Rechargeable Li-ion Battery |
| Display | 2.25" × 3" Full-Color Touchscreen |
| Detectors | 256-element CCD spectroradiometer + PMT photometer |
| Apertures | 1°, 0.5°, 0.25°, 0.125° (motorized) |
| Shutter | Motorized auto-shutter |
| Sync | AutoSync for flicker-free measurement |
| Interfaces | USB 2.0, Bluetooth (optional), RS-232 (via driver), Analog Output (optional) |
| Storage | SD card (up to 32 GB) |
| Operating Modes | Spectral Radiometry, PMT Photometry, Auto-Select Mode |
| Compliance | CIE 1931, CIE 1964, ISO/CIE 11664, ANSI C78.377, IEC 62368-1, FDA 21 CFR Part 11 (via SpectraWin software audit trail) |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-705 |
| Type | Automated |
| Spectral Range | 380–1068 nm (PR-715 variant) |
| Minimum Measurable Spot Size | 0.02 mm |
| Field of View Options | Multiple selectable |
| Radiance Sensitivity | 0.003 cd/m² |
| Haze Measurement Range | 20% |
| Transmittance Measurement Range | 50% |
| Haze Repeatability | ±0.2% |
| Transmittance Repeatability | ±0.5% |
| Measurement Time | 50 ms per acquisition |
| Detector | Thermoelectrically Cooled Sealed InGaAs/Si CCD Array |
| Compliance | MIL-STD-461/810 (as configured for military night vision applications) |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-730/735 |
| Detector Type | Cooled CCD (512 pixels) |
| Spectral Resolution | 0.781 nm/pixel |
| Minimum Luminance | 0.0003 cd/cm² |
| Spectral Bandwidth Options | 2 nm, 5 nm, 8 nm |
| Display | High-resolution full-color touchscreen |
| Communication Interfaces | USB, RS-232, Bluetooth (up to 100 m range) |
| Aperture Options | 8 interchangeable field-of-view apertures |
| Calibration Software | SpectraWin with user-accessible self-calibration module |
| Optical Compatibility | Fully compatible with PR LR-127 LED measurement accessory |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-740/745 |
| Detector Type | Cooled 512-pixel CCD |
| Spectral Resolution | Up to 0.781 nm/pixel |
| Minimum Luminance | 0.000017 cd/cm² |
| Spectral Bandwidth Options | 2 nm, 5 nm, 8 nm |
| Display | High-Resolution Full-Color Touchscreen |
| Interface Options | USB, RS-232, Bluetooth (up to 100 m range) |
| Calibration | User-performed via SpectraWin Remote Mode & Built-in Self-Calibration Software |
| Optical Accessories | Eight interchangeable apertures |
| Compliance | ASTM E308, CIE 15:2018, ISO/CIE 11664, USP <1058> (analytical instrument qualification framework) |
| Brand | Photo Research |
|---|---|
| Model | PR-745 |
| Spectral Range | 380–1080 nm |
| Spectral Bandwidth Options | 4, 8, or 14 nm (automatically selectable) |
| Polarization Error | Ultra-low |
| Stray Light Rejection | High-performance optical design |
| Aperture Options | Up to 8 interchangeable field stops |
| Interface Options | USB (standard), RS-232 (optional), Bluetooth (wireless, optional) |
| Display | Full-color touchscreen |
| Data Storage | SD card |
| Battery Option | Rechargeable Li-ion (8 h operation) |
| Dynamic Range | Optimized for low-light NIR radiance measurement |
| Software | SpectraWin 2® (Windows XP/Vista/7, 32-/64-bit) |
| Compliance | Supports ASTM E308, ISO/CIE colorimetric standards, and GLP/GMP data integrity requirements (audit trail, user access control, electronic signature ready) |
| Brand | Photo Research |
|---|---|
| Model | PR-788 |
| Detector | 512-element cooled CCD array |
| Spectral Bandwidth | Standard 5 nm (optional 2/4/8 nm adjustable) |
| Wavelength Accuracy | < 0.4 nm |
| Spectral Resolution | 1 nm |
| Luminance Range | 1.71×10⁻⁵ to 6.85×10⁶ cd/m² (dependent on aperture and accessory) |
| Aperture Options | 2°, 1°, 0.5°, 0.25°, 0.125°, 0.1°, 0.1°×1° (horizontal slit), 0.5°×1.5° (vertical slit) |
| Colorimetric Accuracy | ±0.0015 CIE x,y |
| Colorimetric Repeatability | ±0.0005 CIE x,y |
| Polarization Error | < 0.2% |
| Stray Light | < 0.06% |
| Exposure Time | 7 ms – 120 s |
| Data Interface | USB, RS-232, Bluetooth |
| Storage | SD card |
| Power | Rechargeable Li-ion battery or 90–240 V AC adapter |
| Operating Temperature | 1–35 °C, ≤90% RH non-condensing |
| Weight | 6.01 kg |
| Dimensions | 28 × 17 × 20.3 cm |
| Digitization | 16-bit ADC |
| Synchronization Frequency | 20–2000 Hz |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model Series | PR-805, PR-810, PR-880, PR-810L |
| Detection Principle | Photomultiplier Tube (PMT) with Precision Interference Filter Wheel Architecture |
| Luminance Range (PR-810L) | 1 × 10⁻⁶ to 5.184 × 10⁵ fL |
| Luminance Range (PR-880) | 1 × 10⁻⁴ cd/m² min |
| Luminance Range (PR-810) | 1 × 10⁻⁴ fL min |
| Luminance Range (PR-805) | 9 × 10⁻⁴ fL min |
| Field-of-View Options | 3°, 1°, 0.25°, 0.125° (PR-810 & PR-810L) |
| Dynamic Range | 9 × 10⁶:1 (PR-805/810), 9 × 10⁸:1 (PR-810L) |
| Built-in Rechargeable Battery | >12 h continuous operation |
| Calibration Traceability | NIST-traceable, internal reference source (PR-880) |
| Compliance | MIL-STD-461E (EMI), ANSI PH2.17, CIE S 014/E:2006, ISO/CIE 11664-2:2019 |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-920 |
| Detector | Scientific-grade thermoelectrically cooled 1024 × 1024 CCD array |
| Spectral Matching | CIE 1931 photopic (V(λ)) and colorimetric (x̄(λ), ȳ(λ), z̄(λ)) functions via precision interference filters |
| Measurement Parameters | Luminance (cd/m²), Chromaticity (CIE x,y |
| Spatial Resolution | Up to 1 megapixel full-frame acquisition |
| Optional Automation | Motorized 5-axis translation stage for programmable area scanning |
| Compliance | ASTM E308, CIE Publication No. 15, ISO/CIE 11664 series, USP <1058> (for instrument qualification in regulated environments) |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-920 |
| Type | Automated Imaging Photometer |
| Luminance Range | Not specified in input |
| Chromaticity Accuracy | Enabled by CIE 1931 Standard Observer-matched filter set |
| Spatial Resolution | 1024 × 1024 pixel cooled CCD array |
| Measurement Capabilities | Luminance, Chromaticity, Luminance Uniformity, Emitter Shape & Distortion, Convergence, MTF (Modulation Transfer Function) |
| Optional Accessory | Motorized 5-axis translation stage for automated spatial scanning |
| Compliance | Designed to support ISO/CIE-compliant photometric and colorimetric measurement workflows |
| Repeatability | High repeatability for luminance and chromaticity (exact values not provided in source data) |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-930 |
| Sensor Type | Interline-cooled CCD |
| Dynamic Range | 12-bit |
| Resolution | 8 MP (3,296 × 2,472) |
| Pixel Size | 5.5 × 5.5 µm |
| Minimum Measurable Spot | 27.5 × 27.5 µm (5×5 pixel binning) |
| FOV (@ 1 | 1 Macro Lens): 18.13 × 13.59 mm |
| Luminance Range | 0.005–500 cd/m² (ND-1 to ND-3 filters optional) |
| Luminance Accuracy (A-source) | ±2% (>0.05 cd/m²), ±3% (0.005–0.05 cd/m²) |
| Luminance Accuracy (Sample) | ±1% (>0.05 cd/m²), ±2% (0.005–0.05 cd/m²) |
| Luminance Repeatability (A-source) | ≥0.2% (>0.05 cd/m²), ≥1% (0.005–0.05 cd/m²) |
| Chromaticity Accuracy (A-source) | ±0.0015 CIE x,y (>0.05 cd/m²), ±0.005 CIE x,y (0.005–0.05 cd/m²) |
| Chromaticity Accuracy (Sample) | ±0.0015 CIE x,y (>0.05 cd/m²), ±0.005 CIE x,y (0.005–0.05 cd/m²) |
| Chromaticity Repeatability | ±0.001 CIE x,y (>0.05 cd/m²), ±0.003 CIE x,y (0.005–0.05 cd/m²) |
| Interface | USB 2.0 |
| Power Input | 100–240 VAC, 50–60 Hz |
| Power Consumption | 12 V, 3.8 A (45.6 W) |
| Operating Temperature | 5–30 °C, non-condensing |
| Weight | 3.77 kg |