| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 8600 |
| Magnet Type | Electromagnetic |
| Measurement Principle | Vibrating Sample Magnetometry (VSM) |
| Temperature Range | 10 K – 1273 K |
| Magnetic Field Range | Up to 3.62 T |
| Magnetic Moment Sensitivity | 5 × 10⁻⁸ emu |
| Field Sweep Rate | 10,000 Oe/s |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | CryoComplete |
| Pricing | Upon Request |
| Temperature Range | 77 K to 500 K |
| Resistance Measurement Range | 100 µΩ to 1 GΩ (standard) |
| Cryogen | Liquid Nitrogen |
| Vacuum Environment | Yes |
| Temperature Stability | ±50 mK |
| LN₂ Capacity | 1.2 L |
| Cool-down Time to 77 K | 15 min |
| Hold Time at 77 K | 8 h |
| Optical Windows | 4 quartz windows |
| Sample Mounting | Pre-wired 8-pin board |
| Measurement Modes | DC, AC (sine/triangle/square), lock-in (3 full channels) |
| Source Current Range | 1 pA to 100 mA |
| Source Frequency Range | 100 µHz to 100 kHz (square wave <5 kHz) |
| Max Measured Voltage | 10 V |
| Input Impedance | >10 GΩ (differential) |
| Sample Leakage Current | 50 pA @ 10 V (coaxial) or 50 fA @ 10 V (guarded triaxial) |
| Voltage Noise | <5 nV/√Hz @ 83 Hz |
| 1/f Voltage Noise (sample test) | <100 nV |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | F71 (3-axis), F41 (1-axis) |
| Measurement Range | 35 mT to 35 T |
| DC Accuracy | ±0.15% of reading (standard probe, 350 mT–3.5 T range) |
| AC Bandwidth | 550 Hz (–3 dB), HF Mode: 20 Hz–7 kHz (–0.2%) |
| Resolution | < 0.1 µT |
| Probe Compatibility | FP-Series Hall Probes only |
| Compliance | Designed for GLP/GMP environments with audit-ready data logging capability |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Microscopy |
| Price | Upon Request |
| Magnetic Field | 0–7 T (Vertical Bore) |
| Bore Diameter | 42 mm (Room-Temperature Bore) |
| Temperature Range | 3.5 K to 325 K (420 K Optional) |
| Vacuum Environment | UHV-Compatible |
| Optical Access | Multiple Collinear & Off-Axis Ports |
| Sample Diameter Capacity | Up to 16 mm |
| Motion Control | High-Precision Motorized X-Y-Z Translation Stage |
| Compatible Cryostat | ST-500 High-Stability Microscope Cryostat |
| Primary Measurement Modalities | Micro-Raman, Photoluminescence (PL), Magneto-Optical Kerr Effect (MOKE) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OptiMag |
| Pricing | Upon Request |
| Magnetic Field Range | 6–12 T (up to 16 T with optional configurations) |
| Temperature Range | 1.5–325 K |
| Sample Bore Diameter | 1.25–1.75 in |
| Helium Dewar Volume | 12 L |
| Hold Time (Static Cryogenic) | ~60 h |
| Field Homogeneity | ±0.5% to ±0.001% over 1 cm Ø sphere |
| Optical Access | Axial (bottom or top), along field direction |
| Cooling Environment | Continuous-flow cryogen or vacuum |
| Compatible Configurations | Vector magnet (2–3 independent coils), horizontal-field, Mössbauer-compatible vertical-drive with top-loaded source/absorber |
| Optional Add-ons | M81 Synchronous Source Transport Measurement System, M91 Fast Hall Probe System, He-3 Insert (<1.4 K), Lambda-point refrigerator (for 9–16 T systems) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Room Temperature Bore Superconducting Magnet |
| Magnetic Field Range | 6–14 T |
| Bore Temperature | Ambient (300 K) |
| Sample Environment Options | Ambient Atmosphere, Vacuum, Ultra-High Vacuum (UHV), Cryogenic Insert Compatible (1.5 K – 800 K) |
| Optical Access | Optional Viewports |
| Bore Diameter | Customizable |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SuperOptiMag |
| Price | Upon Request |
| Magnetic Field Strength | 5–7 T (up to 8 T with Lambda cryocooler) |
| Temperature Range | 1.5 K to 325 K |
| Sample Environment | Continuous-flow cryogen or high-vacuum |
| Optical Access | Bottom, side, and top windows (strain-relieved options available) |
| Field Orientation | Horizontal or vertical |
| Bore Diameter | 0.75 in to 1.25 in |
| Field Homogeneity | ±0.5% over standard sample volume |
| Static Hold Time | ~130 hours (SOM-2 with 1-inch bore, f/2–f/2.5) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | SuperVariMag |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DSR 500 |
| Quotation | Available Upon Request |
| Rotation Speed Range | 0.3–1500 rpm |
| Torque Range | 0.05–30 mN·m |
| Temperature Control Range | −50 °C to 300 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Viscosity Range | 1–5.4×10⁸ mPa·s (dependent on spindle geometry) |
| Display | 7-inch capacitive touchscreen |
| Data Output | USB, RS232, 4–20 mA analog (user-configurable) |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Dimensions (measuring head) | 180 × 135 × 250 mm |
| Stand Dimensions | 280 × 200 × 30 mm |
| Stainless Steel Spindle Rod Length | 500 mm |
| Weight | 6.7 kg |
| Compliance | CE, RoHS, ISO 2555, ASTM D2196, USP <911> (rheological characterization), GLP-compliant data logging |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DSR 500 CP4000 PLUS |
| Price | Upon Request |
| Display | 7″ Touchscreen Interface |
| Rotational Speed Range | 0.3 – 1500 rpm |
| Torque Range | 0.05 – 30 mN·m |
| Temperature Control Range | −50 °C to +300 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Viscosity Range | 1 – 5.4 × 10⁸ mPa·s (dependent on geometry) |
| Shear Rate Control | Direct, programmable |
| Data Output | USB, RS232, 4–20 mA analog |
| Compliance | ASTM D2196, ISO 3219, ISO 6721-10, USP <911>, GLP-ready audit trail in RheoTex software |
| Dimensions (Measurement Head) | 180 × 135 × 250 mm (L×W×H) |
| CP4000 Base Unit | Ø600 × W300 mm |
| Weight | Approx. 22 kg (head + base) |
| Integrated Temperature Probe | Pt100 Class A |
| Language Support | English, French, Spanish, Russian |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Brand | Lamy Rheology |
|---|---|
| Origin | France |
| Model | B-ONE TOUCH |
| Viscosity Range | 1–540,000,000 mPa·s |
| Rotational Speed | 0.3–250 rpm |
| Torque Range | 0.05–13 mN·m (standard) / 0.005–0.8 mN·m (LR version) |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Display | 7" capacitive touchscreen |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Battery Backup | 1 hour operation without AC power |
| Dimensions (probe) | Ø85 mm × 310 mm |
| Dimensions (control unit) | 265 × 125 × 65 mm |
| Weight | 2 kg |
| Compliance | CE, RoHS |
| Safety | 4-digit user password protection |
| Interface | USB, RS232, optional analog 4–20 mA output |
| Brand | Lamy Rheology |
|---|---|
| Origin | France |
| Model | CP2000 |
| Instrument Type | Rotational Viscometer (Fixed Benchtop) |
| Viscosity Range | 1–450,000,000 mPa·s |
| Rotational Speed | 0.3–1500 rpm |
| Torque Range | 0.05–30 mN·m |
| Temperature Control | 5–80 °C (Peltier air-air), ±0.1 °C accuracy |
| Display | 7″ capacitive touchscreen |
| Compliance | ASTM D2196, ISO 2555, ISO 3219, USP <911> |
| Data Output | RS232, USB, 4–20 mA analog |
| Security | User authentication with 4-digit PIN |
| Weight | 22 kg (head + CP2000 stand) |
| Brand | Lamy Rheology |
|---|---|
| Origin | France |
| Model | RM100+ / RM200 / EvA MS-R |
| Viscosity Range | 1–540,000,000 mPa·s |
| Speed Range | 0.3–1500 rpm |
| Torque Range | 0.05–13 mNm (RM100+), 0.05–30 mNm (RM200) |
| Temperature Control | Pt100 sensor (−20 to 120 °C) |
| Compliance | ASTM D2196, ISO 2555, ISO 3219, DIN 53019 |
| Interface | RS-232, USB, parallel port (printer), 4–20 mA analog output |
| Display | 7″ capacitive touchscreen (RM100+ TOUCH variant) |
| Power | 90–240 VAC, 50/60 Hz |
| Software | Visco RM, Rheomatic-T/P |
| Safety | User authentication (4-digit PIN), configurable access levels |
| Brand | Lamy Rheology |
|---|---|
| Origin | France |
| Model | RM200 TOUCH |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | 1–540,000,000 mPa·s |
| Rotational Speed Range | 0.3–1500 rpm |
| Torque Range | 0.05–40 mN·m (AC 115 version) |
| Temperature Range | −50 °C to 300 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Torque Resolution | 100 µN·m |
| Display | 7″ capacitive touchscreen |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Interface | RS232, USB, 4–20 mA analog output |
| Dimensions (head) | 180 × 135 × 250 mm |
| Weight | 6.7 kg |
| Brand | Lamy Rheology |
|---|---|
| Origin | France |
| Model | RM100 TOUCH |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 100–5,000,000,000 mPa·s |
| Rotational Speed | 0.3–1500 rpm |
| Torque Range | 0.05–40 mN·m |
| Temperature Range | −50 °C to 300 °C (with optional RT-1 furnace) |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Display | 7″ capacitive touchscreen |
| Interface | RS232, USB, 4–20 mA analog output |
| Temperature Sensor | Integrated Pt100 |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Dimensions (main unit) | 180 × 135 × 250 mm |
| Weight | 15 kg |
| Compliance | ASTM D2196, ISO 2555, ISO 3219, DIN 53019 |
| Brand | Lamy Rheology |
|---|---|
| Origin | France |
| Model | RM100 + RT-3 High-Temperature Furnace |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–540,000,000 mPa·s |
| Rotational Speed | 0.3–1500 rpm |
| Torque Range (Standard) | 0.05–13 mN·m |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Temperature Control (RT-3) | Ambient to 300 °C ±0.2 °C |
| Display | 7″ capacitive touchscreen |
| Interfaces | RS-232, USB, 4–20 mA analog output |
| Security | User authentication with 4-digit password |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Compliance | CE, RoHS |
| Sample Compatibility | Disposable cups MB-B/C/D, coaxial cylinder systems |
| Software Integration | RHEOMATIP-compatible |
| Data Management | On-device method programming, real-time data logging, USB backup |
| Brand | Lamy Rheology |
|---|---|
| Origin | France |
| Model | RM100i |
| Rotational Speed Range | 0.3–1500 rpm |
| Torque Range | 0.05–13 mNm (Standard) / 0.005–0.8 mNm (LR Version) |
| Viscosity Range | 1–540,000,000 mPa·s |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Temperature Control (with RT-1 furnace) | Ambient to 300 °C (±0.2 °C) |
| Display | 7" capacitive touchscreen |
| Interface | RS232, USB, 4–20 mA analog output |
| Compliance | ASTM D2555, ISO 2555, DIN ISO 3219, MS-R |
| Safety | User authentication via 4-digit password |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Brand | Lamy Rheology |
|---|---|
| Origin | France |
| Model | RM100L TOUCH |
| Instrument Type | Fixed-mount in-line rotational viscometer |
| Viscosity Range | 1–500,000 mPa·s |
| Rotational Speed | 5–600 rpm |
| Torque Range | 0.05–20 mN·m |
| Temperature Compatibility | With PT100 sensor (−20 to +100 °C) |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Display | 7" capacitive touchscreen |
| Analog Output | 4–20 mA (user-configurable torque or viscosity signal) |
| Digital Interfaces | RS232, USB |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Measurement Head Dimensions | Ø85 × 312 mm |
| Control Unit Dimensions | 120 × 145 × 261 mm |
| Total Weight | 4 kg |
| Security | 4-digit password protection with customizable username |
| Cleaning | In-situ CIP-compatible without disassembly |
| Brand | Lamyrheology |
|---|---|
| Origin | France |
| Model | RM200+CP-1 |
| Instrument Type | Rotational Viscometer (Fixed Benchtop) |
| Viscosity Range | 1–540,000,000 mPa·s |
| Rotational Speed | 0.3–1500 rpm |
| Torque Range | 0.05–30 mN·m (standard) |
| Temperature Control | Peltier air-air (5–80 °C ±0.2 °C) |
| Display | 7″ capacitive touchscreen |
| Compliance | ASTM D2196, ISO 2555, ISO 3219, USP <911>, GLP-ready audit trail via RHEOMATIP software |
| Interface | RS232, USB, 4–20 mA analog output |
| Safety | User authentication with 4-digit password |
| Dimensions (main unit) | 300 × 490 × 570 mm |
| Weight | 16 kg |
| Brand | JHX (Distributor) |
|---|---|
| Origin | France |
| Model | RV-SPRING |
| Display | 7-inch capacitive touchscreen |
| Measured Parameters | Viscosity, Torque, Speed, Time, Temperature |
| Viscosity Units | cP, P, mPa·s, Pa·s |
| Shear Rate Control | Yes |
| Temperature Control Interface | Direct integration with external temperature units |
| Operating Languages | English, French, Spanish, Russian |
| User Authentication | 4-digit operator ID |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Analog Output | 4–20 mA (user-configurable torque output) |
| Digital Interfaces | RS232, USB (data export & printer connectivity) |
| Software Compatibility | RheoTex™ |
| Compliance Features | LIMS-ready, QC limit setting, audit trail support for GLP/GMP environments |
| Brand | Lamy Rheology |
|---|---|
| Origin | France |
| Model | TX-700 |
| Touchscreen Display | 7" Color LCD |
| Force Sensor Options | 10 N (1 kg), 20 N (2 kg), 50 N (5 kg), 250 N (20 kg), 500 N (50 kg) |
| Force Resolution | 0.001 N (0.1 g) up to 50 N |
| Force Accuracy | ±0.05 % FS |
| Speed Range | 0.1–10 mm/s (±0.2 %) |
| Maximum Travel Height | 240 mm |
| Displacement Resolution | 0.1 mm |
| Temperature Measurement | Integrated PT100 probe, range −50 °C to +300 °C |
| Sample Platform | Adjustable height, 160 mm diameter, insertable stage 120 × 220 mm |
| Operating Modes | Compression, Relaxation, Tension, TPA Cycle, Penetration, Relative Compression |
| Data Interface | RS232, USB, 4–20 mA analog output |
| Software Control | Optional external PC control via dedicated software |
| Data Export | USB backup and CSV export |
| Safety | Operator ID lock (4-digit numeric code) |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Dimensions (L×W×H) | 610 × 340 × 650 mm |
| Weight | 22 kg |
| Language Support | English, French, Spanish, Russian |
| Compliance | Designed for GLP-compliant environments |
| Brand | Lamyrheology |
|---|---|
| Origin | France |
| Model | RM100 |
| Instrument Type | Fixed Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 15–6,000,000 mPa·s (L1–L4 spindles) / 100–180,000,000 mPa·s (R2–R7 spindles) |
| Rotational Speed | 0.3–250 rpm |
| Torque Range | 0.05–13 mN·m (Standard) / 0.005–0.8 mN·m (LR Version) |
| Accuracy | ±1% of Full Scale |
| Repeatability | ±0.2% |
| Display | 7" Capacitive Touchscreen |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Weight | 6.7 kg |
| Security | User Authentication via 4-digit PIN |
| Brand | Lamyrheology |
|---|---|
| Origin | France |
| Model | BLACK ONE Basic |
| Instrument Type | Fixed Rotational Viscometer |
| Drive System | Direct-Drive Motor (Spring-Free) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 20 – 180 × 10⁶ mPa·s (20 – 180 M mPa·s) |
| Speed Range | 0.3 – 250 rpm (21 discrete speeds) |
| Torque Range | 0.05 – 10 mN·m |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Digital Output | Real-time speed, torque, viscosity, and time-stamped data via RS-232/USB |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Dimensions (W×L×H) | 122 × 130 × 660 mm |
| Weight | 6 kg |
| Spindle Interface | Bayonet-type quick-connect |
| Compliance | ASTM D2196, ASTM D1084, ISO 2555, ISO 3219 |
| Brand | Lamyrheology |
|---|---|
| Origin | France |
| Model | FIRST RM Standard |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 3–180,000,000 mPa·s |
| Rotational Speed | 0.3–250 rpm |
| Torque Range (Standard) | 0.05–13 mN·m |
| Torque Range (LR Version) | 0.005–0.8 mN·m |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Temperature Range (with Pt100 probe) | −50 °C to +300 °C |
| Display | 7" capacitive touchscreen |
| Interface | RS232, USB, 4–20 mA analog output |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Weight | 6.7 kg |
| Compliance | ASTM D2196, ISO 2555, ISO 3219 |
| Brand | Lamyrheology |
|---|---|
| Origin | France |
| Model | GT300 PLUS |
| Instrument Type | Online Rotational Viscometer |
| Viscosity Range | 100–5×10⁹ mPa·s |
| Speed Range | 0.3–1500 rpm |
| Torque Range | 0.05–30 mN·m |
| Temperature Range | 15–300 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Display | 7" capacitive touchscreen |
| Interface | RS232, USB, 4–20 mA analog output |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Dimensions (main unit) | 180 × 135 × 250 mm |
| Weight | 15 kg |
| Brand | Lamyrheology |
|---|---|
| Origin | France |
| Model | RM100 CP2000 PLUS |
| Instrument Type | Benchtop Cone-Plate Rotational Viscometer |
| Viscosity Range | 5–8,000,000 mPa·s |
| Shear Rate Range | 0.1–20,000 s⁻¹ |
| Rotational Speed | 0.3–1500 rpm |
| Torque Range | 0.05–30 mN·m |
| Temperature Range | −20 °C to +300 °C (with external bath or Peltier module) |
| Temperature Accuracy | ±0.1 °C |
| Repeatability | ±0.2% of full scale |
| Display | 7-inch touchscreen interface |
| Connectivity | RS232, USB, 4–20 mA analog output |
| Compliance | GLP-compliant data logging, ASTM D2196/D1084, ISO 2555/3219, USP <911> |
| Language Support | English, French, Spanish, Russian |
| Operator Access Control | 4-digit user ID lock |
| Brand | Lamyrheology |
|---|---|
| Origin | France |
| Model | RM200 CP4000 PLUS |
| Temperature Range | −20 °C to 300 °C |
| Rotational Speed | 0.3–1500 rpm |
| Torque Range | 0.05–30 mN·m |
| Viscosity Range | 1–540,000,000 mPa·s (dependent on geometry) |
| Shear Rate Range | up to 20,000 s⁻¹ |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Display | 7″ capacitive touchscreen |
| Interface | RS-232 serial & USB |
| Temperature Sensor | Integrated Pt100 |
| Gap Auto-Adjustment | Yes |
| Compliance | ASTM D2196, ISO 3219, USP <911>, GLP-ready audit trail support |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | GDCJ-3-100 |
| Temperature Range | −70 °C to +150 °C |
| Test Zone Dimensions | 450 × 450 × 450 mm (W × D × H) |
| Temperature Transition Time (Door Switch) | ≤5 s |
| Temperature Recovery Time in Test Zone | ≤5 min |
| Temperature Uniformity | ±2 °C |
| Heating Rate (Typical) | 40 min (−70 °C → +150 °C) |
| Cooling Rate (Typical) | 45 min (+150 °C → −70 °C) |
| Refrigeration System | Twin-compressor cascade configuration with imported Copeland/Tecumseh or Bitzer semi-hermetic units |
| Control System | PLC-based with 7-inch color TFT-LCD HMI (English/Chinese switchable) |
| Communication Interface | RS-232 standard |
| Compliance | Designed per IEC 60068-2-14, MIL-STD-810G Method 503.5, GB/T 2423.22 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | GDJS-010 |
| Temperature Range | −20 °C to +150 °C |
| Refrigeration | Hermetic Compressor Cooling |
| Explosion-Proof | Standard (Non-Explosion-Proof) |
| Temperature Uniformity | ±1 °C |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Deviation | ±1 °C |
| Heating Rate | ≤60 min (−20 °C → +150 °C) |
| Cooling Rate | ≤80 min (+150 °C → −20 °C) |
| Interior Dimensions | 450 × 450 × 450 mm |
| Internal Volume | 91.1 L |
| Humidity Range | 30–98 %RH |
| Humidity Control Accuracy | ±2–3 %RH |
| Controller | Fuji PID-based Touchscreen HMI with Programmable Profile Storage |
| Construction | SUS304 Stainless Steel Interior |
| Insulation | Polyurethane Foam (≥100 mm Thickness) |
| Viewing Window | Double-Layer Hollow Glass with Anti-Condensation Heater |
| Safety Protections | Low-Water Cut-off, Over-Temperature Cut-off, Compressor High-Pressure Protection |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | GFGDJS-1500 |
| Internal Dimensions (W×D×H) | 1000 × 1000 × 1500 mm |
| Temperature Range | −40 °C to +100 °C |
| Temperature Cycling Range | −40 °C to +100 °C |
| Humidity Range | 30–98% RH (at 40–90 °C) |
| Humidity Cycling Range | 75–95% RH (at 25–85 °C) |
| Temperature Uniformity | ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Deviation | +2 / −3% RH |
| Heating/Cooling Rate | 1.0–2.0 °C/min (linearly adjustable) |
| Timer Range | 0–9999 h |
| Power Supply | AC 380 V, 50 Hz |
| Total Power Consumption | 32 kW |
| Refrigerant | R23 / R404A |
| Control Resolution | 0.1 °C |
| Display | 5.7″ LED touchscreen interface |
| Compliance | GB/T 19394–2003, GB/T 9535–1998, GB/T 6492–1986, IEC 61215:2005, IEC 61646, IEC 61345:1998 |