- All
- Favorite
- Popular
- Most rated
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JBS-500B |
| Instrument Type | Pendulum Impact Tester |
| Impact Energy | 500 J (large hammer), 250 J (small hammer) |
| Impact Velocity | 5.4 m/s |
| Pendulum Lift Angle | 150° |
| Support Span | 40 mm |
| Anvil Radius | R1.0–R1.5 mm |
| Striking Edge Radius | R2.0–R2.5 mm |
| Distance from Pendulum Center to Impact Point | 800 mm |
| Standard Specimen Dimensions | 10 × 10 × 55 mm |
| Power Supply | 3-phase 4-wire, 50 Hz, 380 V |
| Angular Accuracy | ±0.1° |
| Mainframe Dimensions (L×W×H) | 2124 × 600 × 1340 mm |
| Digital Control Cabinet Dimensions (L×W×H) | 360 × 400 × 1200 mm |
| Net Weight | 450 kg |
| Environmental Requirements | Non-corrosive atmosphere, vibration-free installation site, absence of strong electromagnetic fields |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JB-300C |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energy | 300 J / 150 J (achieved via adjustable counterweights) |
| Impact Velocity | 5.2 m/s |
| Pendulum Pre-Lift Angle | 150° |
| Specimen Support Span | 40 mm |
| Support Anvil Radius | R1.0–R1.5 mm |
| Striking Edge Radius | R2.0–R2.5 mm and R8 mm |
| Distance from Pendulum Pivot to Impact Point | 750 mm |
| Standard Specimen Dimensions | 10 × 10 × 55 mm |
| Power Supply | 3-phase, 4-wire, 50 Hz, 380 V, 180 W |
| Overall Dimensions | 2124 × 600 × 1340 mm |
| Angular Resolution | ±0.1° |
| Axial Positioning Accuracy | ±0.05 mm |
| Net Weight | 450 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | JBW-750C |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energies | 750 J, 600 J, 450 J, 300 J, 150 J |
| Impact Velocity | 5.5 m/s |
| Pendulum Pre-Lift Angle | 150° |
| Distance from Pendulum Axis to Impact Point | 825 mm |
| Specimen Support Span | 40 mm |
| Anvil Radius (Clamp Corner) | R1–R1.5 mm |
| Striking Edge Radius | R2–R2.5 mm (standard: R2 mm |
| optional | R8 mm) |
| Striking Edge Angle | 30° |
| Striking Edge Thickness | 16 mm |
| Specimen Support Surface Tilt | 0° |
| Specimen Dimensions | 10 × 10 (or 7.5 or 5) × 55 mm |
| Overall Dimensions | 2450 × 1200 × 2455 mm |
| Net Weight | 2500 kg |
| Power Supply | 3-phase AC 380 V ±10%, 50 Hz, 5 A |
| Operating Temperature Range | 10–35 °C |
| Relative Humidity Limit | ≤85% RH |
| Installation Requirement | Mounted on ≥300 mm thick reinforced concrete foundation or ≥1500 kg rigid base |
| Leveling Tolerance | ≤0.2 mm/m on machine base reference surface |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CSL-1 |
| Sample Dimensions Supported | 10×10×55 mm, 10×7.5×55 mm, 10×5×55 mm |
| Notch Types | V-notch (GB/T 229–2007, ISO 148-1:2016 compliant) and U-notch (2 mm root radius, GB/T 229–2007) |
| Notching Stroke | 350 mm |
| Feed Rate | 2.5 mm/min |
| Overall Dimensions (L×W×H) | 350×350×700 mm |
| Net Weight | 80 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WEW-1000B |
| Instrument Category | Universal Testing Machine (UTM) – Hydraulic, Dual-Column, Floor-Mounted |
| Max Test Force | 1000 kN |
| Force Accuracy | ±1% or ±0.5% (per ISO 7500-1 Class 1) |
| Force Resolution | 0.01 kN |
| Displacement Resolution | 0.01 mm |
| Deformation Measurement Accuracy | 0.01 mm |
| Tensile Space | 700 mm |
| Compression Space | 380 mm |
| Piston Stroke | 150 mm |
| Round Specimen Grip Range | Φ13–Φ40 mm |
| Flat Specimen Grip Thickness | 0–15 mm |
| Flat Specimen Max Grip Width | 75 mm |
| Compression Platen Diameter | φ160 mm (optional 204×204 mm square platen) |
| Bend Support Span | Adjustable up to 450 mm |
| Bend Roller Width | 140 mm |
| Bend Roller Diameter | Φ40 mm |
| Max Bending Deflection | 150 mm |
| Max Crosshead Speed | 50 mm/min |
| Gripping Method | Hydraulic Auto-Grip System |
| Power Supply | Main Oil Pump Motor 1.1 kW + Crosshead Motor 0.75 kW |
| Host Dimensions (W×D×H) | 890×660×2250 mm |
| Control Console Dimensions (W×D×H) | 1000×700×1400 mm |
| Net Weight | 2700 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WEW-300B |
| Instrument Category | Universal Testing Machine (UTM) |
| Max. Test Load | 300 kN |
| Load Range | 12–300 kN |
| Load Accuracy | ±1% or ±0.5% |
| Load Resolution | 0.01 kN |
| Displacement Resolution | 0.01 mm |
| Deformation Measurement Accuracy | 0.01 mm |
| Tensile Space | 550 mm |
| Compression Space | 380 mm |
| Piston Stroke | 150 mm |
| Round Specimen Grip Diameter | Φ6–Φ26 mm |
| Flat Specimen Grip Thickness | 0–15 mm |
| Flat Specimen Max. Grip Width | 75 mm |
| Compression Platen Diameter | φ160 mm (optional 204×204 mm) |
| Bending Span (Two-Point) | 450 mm |
| Bending Roller Width | 120 mm |
| Bending Roller Diameter | Φ30 mm |
| Max. Bending Deflection | 150 mm |
| Max. Piston Speed | 50 mm/min |
| Clamping Method | Automatic Hydraulic Clamping |
| Round Specimen Jaw Sets | Φ6–Φ13 mm & Φ13–Φ26 mm |
| Flat Specimen Jaw Set | 0–15 mm |
| Compression Fixture | φ160 mm |
| Bending Fixture | Two-point support, max. span 450 mm |
| Oil Pump Motor Power | 1.1 kW |
| Crosshead Motor Power | 0.75 kW |
| Mainframe Dimensions (W×D×H) | 720×580×1950 mm |
| Control Cabinet Dimensions (W×D×H) | 1000×700×1400 mm |
| Weight | 2150 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | JBS-300Z |
| Impact Energy | 150 J / 300 J |
| Impact Velocity | 5.2 m/s |
| Compliance | GB/T 229–2007, GB/T 3803–2002 |
| Control System | Microcontroller-Based Digital Measurement & Display |
| Output | Printed Test Reports (Absorbed Energy, Pendulum Lift Angle, Mean Value) |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JBS-300B |
| Instrument Category | Charpy/Izod Impact Tester |
| Nominal Impact Energy | 150 J / 300 J |
| Impact Velocity | 5.2 m/s |
| Pendulum Center-to-Anvil Distance | 750 mm |
| Specimen Span | 40.0 ± 0.2 mm |
| Pendulum Pre-lift Angle | 150° |
| Impact Blade Radius | R2–R2.5 mm (standard), R8 ± 0.05 mm (optional) |
| Specimen Dimensions | 10 × 10 × 55 mm (also compatible with 7.5, 5, and 2.5 mm thickness variants) |
| Anvil Radius | R1–R1.5 mm |
| Compliance | GB/T 229–2007, GB/T 3803–2002 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JB-750C |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energies | 750 J, 600 J, 450 J, 300 J, 150 J |
| Impact Velocity | 5.5 m/s |
| Pendulum Arm Length (from pivot to impact point) | 825 mm |
| Pre-lift Angle | 150° |
| Anvil Span | 40 mm |
| Specimen Dimensions | 10 × 10 (or 7.5 or 5) × 55 mm |
| Hammer Nose Radius | R2–R2.5 mm (standard R2 mm |
| Hammer Included Angle | 30° |
| Hammer Blade Thickness | 16 mm |
| Specimen Support Surface Tilt | 0° |
| Base Plate Leveling Tolerance | ≤0.2/1000 |
| Power Supply | 3-phase AC 380 V ±10%, 50 Hz, 5 A |
| Net Weight | 2500 kg |
| Overall Dimensions | 2450 × 1200 × 2455 mm |
| Environmental Requirements | Ambient temperature 10–35 °C |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JBS-300C |
| Instrument Type | Pendulum Impact Tester |
| Impact Energy | 300 J (large hammer), 150 J (small hammer) |
| Impact Velocity | 5.2 m/s |
| Pendulum Pre-Lift Angle | 150° |
| Specimen Support Span | 40 mm |
| Support Anvil Fillet Radius | R1.0–R1.5 mm |
| Striking Edge Fillet Radius | R2.0–R2.5 mm and R8 mm |
| Distance from Pendulum Pivot to Impact Point | 750 mm |
| Standard Specimen Dimensions | 10 × 10 × 55 mm |
| Power Supply | 3-phase, 4-wire, 50 Hz, 380 V, 180 W |
| Overall Dimensions | 2124 × 600 × 1340 mm |
| Angular Accuracy | ±0.1° |
| Axial Positioning Accuracy | ±0.05 mm |
| Net Weight | 450 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JBN-300 |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energies | 150 J, 300 J |
| Impact Velocity | 5.2 m/s |
| Pendulum Arm Length (from axis to impact point) | 750 mm |
| Specimen Support Span | 40 mm |
| Anvil Radius (Charpy/Izod) | R1–R1.5 mm |
| Hammer Nose Radius | R2–R2.5 mm |
| Hammer Blade Thickness | 16 mm |
| Angular Accuracy | ±0.1° |
| Standard Specimen Dimensions | 10 × 10 × 55 mm |
| Machine Dimensions (L×W×H) | 2300 × 600 × 1400 mm |
| Net Weight | 550 kg |
| Power Supply | 3-phase AC 380 V ±10%, 50 Hz, 5 A |
| Environmental Requirements | Non-corrosive atmosphere, vibration-free installation site, absence of strong electromagnetic fields |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JBDW-450C |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energy | 450 J |
| Impact Velocity | 5.2 m/s |
| Temperature Range | –190 °C to +20 °C (–196 °C achievable with ≥99.99% liquid nitrogen) |
| Specimen Dimensions | 10 mm × 10 mm × 55 mm |
| Anvil Span | 40 mm |
| Hammer Blade Radius | R2–R2.5 mm |
| Hammer Thickness | 16 mm |
| Pendulum Arm Length | 800 mm |
| Pre-lift Angle | 150° |
| Temperature Stability | ±2 °C fluctuation, ≤3 °C gradient |
| Specimen Tray Capacity | 6 positions (4 uniformly cooled) |
| Refrigeration Method | Liquid Nitrogen Cooling |
| Net Weight | 880 kg |
| Power Supply | 3-phase AC 380 V ±10% |
| Overall Dimensions | 1600 mm × 850 mm × 1530 mm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC009-JB-300B / MC009-JB-500B |
| Quotation | Available Upon Request |
| Impact Energy | 150/300 J (JB-300B) / 250/500 J (JB-500B) |
| Pendulum Pivot-to-Impact Point Distance | 750 mm (JB-300B) / 800 mm (JB-500B) |
| Impact Velocity | 5.2 m/s (JB-300B) / 5.4 m/s (JB-500B) |
| Pre-Lift Angle | 150° |
| Specimen Support Span | 40 mm |
| Anvil Radius | R1–R1.5 mm |
| Striking Edge Radius | R2–R2.5 mm and R8 ± 0.05 mm |
| Specimen Dimensions | 10 × 10 × 55 mm (standard), with optional 7.5, 5, or 2.5 mm thicknesses |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | JB-500B |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energies | 250 J, 500 J |
| Impact Velocity | 5.4 m/s |
| Pendulum Arm Length (from pivot to impact point) | 800 mm |
| Specimen Support Span | 40 mm |
| Anvil Radius (support edge) | R1–R1.5 mm |
| Striking Edge Radius | R2–R2.5 mm |
| Striking Blade Thickness | 16 mm |
| Angular Accuracy | ±0.1° |
| Standard Specimen Dimensions | 10 mm × 10 mm × 55 mm |
| Overall Dimensions (L×W×H) | 2300 mm × 600 mm × 1400 mm |
| Net Weight | 550 kg |
| Power Supply | 3-phase AC 380 V ±10%, 50 Hz, 5 A |
| Ambient Requirements | Non-corrosive environment, free from mechanical vibration and strong electromagnetic fields |
| Brand | YANRUN |
|---|---|
| Model | JBDW-500Y |
| Type | Pendulum Impact Tester |
| Impact Energy | 250 J, 500 J |
| Impact Velocity | 5.4 m/s |
| Pendulum Arm Length | 800 mm |
| Specimen Span | 40 mm |
| Notch Radius (Anvil) | R1–R1.5 mm |
| Impact Blade Radius | R2–R2.5 mm |
| Blade Thickness | 16 mm |
| Cooling Method | Compressor-Based Refrigeration |
| Temperature Range | 0 °C to –60 °C |
| Temperature Stability | ±1.5 °C fluctuation, ≤2 °C gradient |
| Specimen Dimensions | 10 mm × 10 mm × 55 mm |
| Machine Dimensions (L×W×H) | 1500 mm × 850 mm × 1340 mm |
| Net Weight | 850 kg |
| Power Supply | 3-phase AC 380 V ±10%, 50 Hz, 5 A |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JB-500C |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energy | 250 J / 500 J (achieved via interchangeable pendulum weights) |
| Impact Velocity | 5.4 m/s |
| Pendulum Pre-lift Angle | 150° |
| Support Span | 40 mm |
| Anvil Radius (support) | R1.0–R1.5 mm |
| Striking Edge Radius | R2.0–R2.5 mm |
| Striking Blade Thickness | 16 mm |
| Distance from Pendulum Axis to Impact Point | 800 mm |
| Standard Specimen Dimensions | 10 × 10 × 55 mm |
| Power Supply | 3-phase, 4-wire, 50 Hz, 380 V, 180 W |
| Overall Dimensions (L×W×H) | 2124 × 600 × 1340 mm |
| Minimum Resolution | 2.5 J |
| Axial Positioning Accuracy | ±0.05 mm |
| Net Weight | 450 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WAW-300B |
| Instrument Category | Universal Testing Machine (UTM) |
| Maximum Test Load | 300 kN |
| Force Range | 6–300 kN |
| Force Accuracy | ±1% or ±0.5% of full scale (FS) |
| Force Resolution | 0.002 kN |
| Displacement Resolution | 0.01 mm |
| Deformation Measurement Accuracy | 0.005 mm |
| Control Modes | Constant Force / Constant Displacement / Constant Strain (0.4–100% FS) |
| Control Accuracy | ±1.0% of set value when <10% FS |
| Tensile Space | 650 mm |
| Compression Space | 550 mm |
| Piston Stroke | 200 mm |
| Round Specimen Clamping Diameter | Φ6–Φ26 mm |
| Flat Specimen Clamping Thickness | 0–15 mm |
| Bending Span (Two-Point) | 350 mm |
| Bending Support Roller Width | 140 mm |
| Bending Support Roller Diameter | Φ30 mm |
| Max Bending Deflection | 150 mm |
| Max Piston Speed | 50 mm/min |
| Gripping Method | Hydraulic |
| Host Dimensions (W×D×H) | 850 × 580 × 2150 mm |
| Oil Source Dimensions (W×D×H) | 950 × 700 × 1150 mm |
| Weight | 2150 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | WES-600 |
| Max Test Force | 600 kN |
| Force Measurement Range | 4–100% FS |
| Force Accuracy | ≤ ±1% of reading |
| Force Resolution | 0.01 kN |
| Tensile Space | 650 mm |
| Compression Space | 380 mm |
| Gripping Method | Manual (hydraulic option available) |
| Round Specimen Clamping Diameter | Φ13–40 mm |
| Flat Specimen Thickness Capacity | 0–15 mm (optional: 15–30 mm) |
| Flat Specimen Max Width | 75 mm |
| Structural Layout | Bottom-mounted hydraulic actuator |
| Safety Protection | Overload and stroke limit protection |
| Display | LCD digital interface |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC009-JB-300S / MC009-JB-500S |
| Price | Upon Request |
| Impact Energy | 150/300 J (JB-300S) / 250/500 J (JB-500S) |
| Pendulum Pivot-to-Impact Point Distance | 750 mm (JB-300S) / 800 mm (JB-500S) |
| Impact Velocity | 5.2 m/s (JB-300S) / 5.4 m/s (JB-500S) |
| Pre-lift Angle | 150° |
| Support Span | 40 mm |
| Anvil Radius | R1–R1.5 mm |
| Striking Edge Radius | R2–R2.5 mm and R8 ± 0.05 mm |
| Specimen Dimensions | 10 (or 7.5, 5, 2.5) × 10 × 55 mm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC009-JB-300 |
| Quotation | Upon Request |
| Impact Energy | 150/300 J |
| Impact Velocity | 5.0 m/s |
| Pendulum Pre-lift Angle | 135° |
| Anvil Span | 40 mm |
| Anvil Radius (Notch Support) | R1.0–R1.5 mm |
| Striking Edge Radius | R2.0–R2.5 mm |
| Standard Specimen Dimensions | 10 × 10 × 55 mm |
| Pendulum Arm Length | 800 mm |
| Overall Dimensions (L×W×H) | 1000 × 630 × 1520 mm |
| Net Weight | 320 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JB-50 |
| Instrument Type | Pendulum Impact Tester |
| Impact Energy | 50 J (large hammer), 25 J (small hammer) |
| Impact Velocity | 4.0 m/s |
| Pre-lift Angle | 150° |
| Support Span | 40 mm |
| Anvil Radius | R1.0–R1.5 mm |
| Striking Edge Radius | R2.0–R2.5 mm |
| Distance from Pendulum Center to Impact Point | 550 mm |
| Standard Specimen Dimensions | 10 × 10 × 55 mm |
| Overall Dimensions | 800 × 530 × 1200 mm |
| Weight | 150 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | JB-300 |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energy | 300 J (large hammer), 150 J (small hammer) |
| Impact Velocity | 5.0 m/s |
| Pendulum Pre-lift Angle | 135° |
| Support Span | 40 mm |
| Anvil Radius (Support Edge) | R1.0–R1.5 mm |
| Striking Edge Radius (Hammer Nose) | R2.0–R2.5 mm |
| Distance from Pendulum Center to Impact Point | 800 mm |
| Standard Specimen Dimensions | 10 × 10 × 55 mm |
| Overall Dimensions (L×W×H) | 1000 × 630 × 1520 mm |
| Net Weight | 350 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WES-100B |
| Instrument Category | Universal Testing Machine (UTM) |
| Maximum Test Load | 100 kN |
| Force Range | 4–100% FS |
| Force Measurement Accuracy | ≤ ±1% of reading |
| Force Resolution | 0.01 kN |
| Tensile Test Space | 550 mm |
| Compression Test Space | 380 mm |
| Gripping Method | Manual |
| Round Specimen Diameter Range | Φ6–26 mm |
| Flat Specimen Thickness Range | 0–15 mm |
| Flat Specimen Max Jaw Width | 70 mm |
| Brand | YANRUN |
|---|---|
| Model | JBWS-300C |
| Type | Pendulum Impact Tester |
| Impact Energy | 150 J / 300 J (achieved via adjustable counterweight assembly) |
| Impact Velocity | 5.2 m/s |
| Pendulum Lift Angle | 150° |
| Support Span | 40 mm |
| Anvil Radius (support) | R1.0–R1.5 mm |
| Striking Edge Radius | R2.0–R2.5 mm and R8 mm |
| Distance from Pendulum Axis to Impact Point | 750 mm |
| Standard Specimen Dimensions | 10 × 10 × 55 mm |
| Power Supply | 3-phase, 4-wire, 380 V, 50 Hz, 180 W |
| Angular Accuracy | ±0.1° |
| Axial Positioning Accuracy | ±0.05 mm |
| Machine Weight | 450 kg |
| Overall Dimensions (L×W×H) | 2124 × 600 × 1340 mm |
Show next