| Brand | BRIGHT |
|---|---|
| Origin | United Kingdom |
| Model | Chiron 300D |
| Dimensions (L×W×D) | 725 × 900 × 360 mm |
| Number of Grinding/Polishing Plates | 2 |
| Plate Diameter | 300 mm |
| Speed Control | Stepless DC speed regulation from 100–1000 rpm (10 rpm increments) with optional fixed-speed modes at 250 / 500 / 750 / 1000 rpm |
| Vertical Feed Resolution | 0.1 mm per step |
| Rotation Direction | Reversible (clockwise/counterclockwise) |
| Motor | Brushless DC, 220 V, 1.1 kW |
| Water Supply | 6 mm OD tubing, 40–100 psi |
| Net Weight | 95 kg |
| Housing Material | Integrated ABS safety shroud and waste tray |
| Base Construction | Precision-cast iron chassis |
| Surface Treatment | PTFE-coated plate adapters for rapid consumable change |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASIN |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Model | Helios 5 DualBeam |
| Landing Voltage Range | 20 eV – 30 keV |
| SEM Resolution | Down to 0.6 nm @ 15–30 keV (depending on configuration) |
| FIB Current Range | 1 pA – 100 nA |
| Ion Acceleration Voltage | 500 V – 30 kV |
| Stage Travel | Up to 150 × 150 × 10 mm (X/Y/Z, model-dependent) |
| Automated TEM Lamella Preparation | Supported (via AutoTEM 5 software) |
| STEM Imaging Capability | Integrated (sub-nm resolution at 30 keV) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | Czech Republic |
| Model | Talos F200i S/TEM |
| Accelerating Voltage | 20–200 kV |
| TEM Line Resolution | ≤0.10 nm |
| TEM Information Resolution | ≤0.12 nm |
| STEM Resolution | ≤0.16 nm |
| LACBED Convergence Angle | ≥100 mrad |
| Diffraction Angle | up to 24° |
| EDS Configuration | Side-mounted, retractable |
| Electron Source | High-brightness field emission gun (FEG) |
| Specimen Stage Z-Travel (standard holder) | ±0.375 mm |
| Tilt Range (3D tomography holder) | ±90° |
| Specimen Drift | ≤0.5 nm/min |
| Camera | 4k × 4k Ceta 16M CMOS |
| Brand | BRIGHT |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MAS600 |
| Total Magnification | 1× (Macro-scale imaging, non-magnifying optical path) |
| Zoom Ratio | None (Fixed-optic macro imaging system) |
| Field Diameter | 20–500 mm |
| Working Distance | 15–500 mm |
| Objective Type | N/A (Integrated telecentric macro optics) |
| Illumination Type | Adjustable LED Ring Light |
| Depth of Field | 10 mm |
| Numerical Aperture | 0.005 |
| Image Sensor | 5.0 MP Color sCMOS |
| Max Display Resolution | 2560 × 1920 (5.0 MP) |
| Zoom Range | 22× digital pan-zoom (software-based, non-optical) |
| Minimum Field of View | 1.5 mm × 1.0 mm |
| Maximum Field of View | 330 mm × 240 mm |
| Output Interface | USB 3.0 |
| Power Input | 24 V DC |
| Column Height | 600 mm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Model | Helios 5 Laser PFIB |
| Integrated Beams | SEM + Plasma FIB (Xe⁺) + Femtosecond Laser (1030 nm / 515 nm) |
| Laser Pulse Width | <280 fs (1ω), <300 fs (2ω) |
| Laser Repetition Rate | 1 kHz – 1 MHz |
| Laser Spot Size | 15 µm |
| Maximum 3D Volume | 2000 × 2000 × 1000 µm³ |
| Plasma FIB Beam Current | ~1 mA (equivalent), Cutting Current: 74 µA |
| Beam Co-location Accuracy | <250 nm at WD = 4 mm |
| Laser Safety Class | Class 1 Enclosed System |
| Software | Integrated Laser Control, Automated 3D Serial Sectioning Workflow, EBSD-Coupled 3D Reconstruction Module, Scriptable Laser Programming Interface |
| Brand | GATAN |
|---|---|
| Origin | USA |
| Model | SOLARUS (950) |
| RF Power | 50 W with auto-matching |
| Vacuum System | 70 L/s turbomolecular pump + dual-stage diaphragm pump |
| Base Pressure | 5 × 10⁻⁶ Torr |
| Operating Pressure | 400 mTorr |
| Chamber Dimensions | 3.5" diameter × 2.0" depth |
| Gas Control | Triple independent MFCs (H₂, O₂, Ar) |
| Cleaning Cycle Time | <2 min (pump-down + plasma treatment + vent) |
| Sample Loading | Dual front ports for TEM/SEM sample holders + top port for >25 TEM grids or SEM stages |
| Plasma Observation | Integrated viewport |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Model | Apreo ChemiSEM |
| Instrument Type | Floor-standing High-Resolution FE-SEM |
| Electron Gun | Schottky Thermal Field Emission |
| Secondary Electron Resolution | 0.7 nm @ 30 kV |
| Backscattered Electron Resolution | 0.7 nm @ 30 kV |
| Magnification Range | 50× – 1,000,000× |
| Accelerating Voltage | 200 V – 30 kV |
| Landing Energy Range | 20 eV – 30 keV |
| Maximum Sample Size at 10 mm WD | 3 mm (min. mag. 29×) |
| Chamber Ports | 18 |
| Stage Travel | X = 110 mm, Y = 110 mm, Z = 65 mm, Tilt = −15° to +90°, Rotation = 360° continuous |
| Standard Detector System | Trinity In-lens Detection System (T1, T2, T3), TD, DBS |
| Optional Detectors | DBS-GAD, Low-Vacuum SE Detector, STEM 3+ Segmented Detector (BF/DF/HADF/HAADF), IR CCD, Thermo Scientific™ Nav-Cam™ Navigation Camera |
| Brand | Gatan |
|---|---|
| Origin | USA |
| Model | Alto 2500 |
| Vacuum Performance | <1×10⁻⁶ mbar (preparation chamber) |
| Operating Temperature Range | –190 °C to +50 °C (sample stage) |
| Cooling Method | Liquid nitrogen–cooled cryo-stage & subcooled nitrogen gas–cooled SEM stage |
| Cryo-Stage Stability | ±1 °C |
| Imaging Compatibility | Field-emission SEM (FE-SEM), FIB-SEM, and dual-beam systems |
| Brand | BRIGHT |
|---|---|
| Origin | United Kingdom |
| Model | Chiron 250DA |
| Disc Diameter | 254 mm |
| Disc Quantity | 2 |
| Speed Range (Main Disc) | 100–1000 rpm, infinitely variable |
| Speed Range (Grinding Head) | 20–120 rpm, infinitely variable |
| Sample Holders | 6 positions |
| Holder Sizes | Φ22 mm / Φ30 mm / Φ45 mm |
| Z-Axis Grinding Depth | 0.1 mm per step, adjustable from 0 to 5 mm |
| Pressure Modes | Single-point pneumatic (0–50 N) and central pneumatic (0–160 N) |
| Motor Type | Brushless DC motor (220 V, 1.1 kW) + Stepper motor for grinding head (26 V, 200 W) |
| Timer Range | 0–99 minutes |
| Dimensions (L×W×D) | 725 × 1200 × 760 mm |
| Net Weight | 134 kg |
| Compliance | CE, RoHS, ISO 15510 (Metallographic Sample Preparation), ASTM E3, ISO 643, EN 10365 |
| Brand | BRIGHT |
|---|---|
| Origin | United Kingdom |
| Model | Cratos W50S |
| Instrument Type | Microhardness Tester |
| Test Force Range | 0.098–9.80 N (10–1000 gf) |
| Hardness Range | 1–2967 HV |
| Measurement Modes | HV / HK |
| Compliance | ISO 6507, ASTM E384, JIS Z2244, GB/T 4340.2 |
| Resolution | 0.025 µm |
| Dwell Time | 0–60 s |
| Illumination | Halogen |
| Max Specimen Height | 185 mm |
| Dimensions | 560 × 335 × 675 mm |
| Weight | 52 kg |
| Brand | Gatan |
|---|---|
| Origin | USA |
| Model | SmartEMIC |
| Price | $120,000 |
| Category | Electron Microscope Accessories & Peripherals |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Model | Quattro |
| Instrument Type | Floor-standing SEM |
| Electron Source | Cold Field-Emission Gun (CFEG) |
| Magnification Range | 6× to 2,500,000× |
| Accelerating Voltage | 200 V to 30 kV |
| Landing Voltage | 20 eV to 30 keV (with beam deceleration option) |
| Probe Current | 1 pA to 200 nA (continuously adjustable) |
| Secondary Electron Resolution | 1.3 nm @ 30 kV (SE, low-vacuum mode) |
| Backscattered Electron Resolution | 2.5 nm @ 30 kV (BSE, high-vacuum mode) |
| Working Distance for EDS | 10 mm |
| EDS Take-off Angle | 35° |
| Chamber Width | 340 mm |
| Number of Available Ports | 12 (including 3 EDS-compatible ports, two at 180° opposition) |
| Stage Type | 5-axis motorized eucentric stage |
| XY Travel (Quattro C / Quattro S) | 55 × 55 mm / 110 × 110 mm |
| Z Travel | 65 mm |
| Tilt Range | –15° to +90° |
| Rotation | Continuous 360° |
| Maximum Sample Height (from eucentric height) | 85 mm |
| Max Sample Weight | 5 kg (at 0° tilt) |
| Max Sample Diameter (full rotation compatible) | 122 mm |
| Detector Options | In-chamber Everhart-Thornley detector (ETD), Low-Vacuum Detector (LVD), Gas Secondary Electron Detector (GSED), Integrated STEM-in-SEM (WetSTEM™), IR-CCD chamber camera, Nav-Cam™ optical navigation camera |
| Software Platform | 64-bit Windows-based GUI with multi-view display, montage navigation, undo/redo functionality, joystick and multifunction control panel support |
| Brand | ROCK |
|---|---|
| Origin | Hong Kong, China |
| Model | MaipSCAN |
| Instrument Type | Floor-standing SEM |
| Electron Source | Tungsten Filament |
| Secondary Electron Resolution | 3.0 nm @ 30 kV (SE and W) |
| Magnification Range | 7× – 1,000,000× |
| Accelerating Voltage | 0.2 – 30 kV |
| Backscattered Electron Resolution | 4.0 nm @ 30 kV (VP mode with BSD) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Model | Scios 2 DualBeam |
| Electron Source | Schottky Field Emission Gun |
| STEM Resolution | 0.8 nm at 30 kV (WD = 7 mm) |
| SEM Resolution | 1.6 nm at 1 keV, 1.4 nm at 1 keV with beam deceleration |
| Ion Beam Resolution | 3.0 nm at 30 kV |
| Ion Beam Current Range | 1.5 pA – 65 nA |
| Electron Beam Current Range | 1 pA – 400 nA |
| Acceleration Voltage (e-beam) | 200 V – 30 kV |
| Landing Voltage (e-beam) | 20 eV – 30 kV |
| Acceleration Voltage (ion-beam) | 500 V – 30 kV |
| Stage | 5-axis motorized, X/Y = 110 mm, Z = 65 mm, tilt = −15° to +90°, rotation = 360° |
| Maximum Sample Diameter | 110 mm |
| Maximum Sample Height (at full X/Y rotation) | 85 mm |
| Maximum Sample Mass | 5 kg |
| Chamber Ports | 21 |
| Chamber Inner Width | 379 mm |
| Integrated Detectors | In-lens ETD, T1 (in-lens BSE), T2 (in-lens SE), optional T3 (in-lens SE), DBS (segmented solid-state BSE), ICE (ion conversion & electron detector), IR-CCD, Nav-Cam+™ optical navigation camera |
| Brand | Gatan |
|---|---|
| Origin | USA |
| Model | C1000 |
| Temperature Range | –185 °C to +400 °C (model-dependent) |
| Cooling Medium | Liquid Nitrogen |
| Sample Diameter | 10 mm |
| Cooling Time | <10 min (RT to –185 °C) |
| Temperature Stability | ±0.5 °C |
| Tilt | 45° |
| Rotation | ±5° |
| Compatibility | Field-emission, standard, and environmental SEMs |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SFA |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Czech Republic |
| Model | Prisma E SEM |
| Instrument Type | Floor-standing SEM |
| Electron Source | Tungsten Filament |
| Secondary Electron Resolution | 3.0 nm @ 30 kV (SE), 8.0 nm @ 3 kV (SE) |
| Backscattered Electron Resolution | 4.0 nm @ 3 kV (BSE), 10 nm @ 3 kV (SE) |
| Accelerating Voltage | 200 V – 30 kV |
| Magnification Range | 5× – 1,000,000× |
| Low Vacuum Range | up to 130 Pa |
| ESEM Mode Pressure | up to 2600 Pa (H₂O), 4000 Pa (N₂) |
| Sample Chamber Width | 340 mm |
| Expandable Ports | 12 total, including 3 EDS ports (2 at 180° opposing positions) |
| Stage | 5-axis motorized eucentric stage (X=110 mm, Y=110 mm, Z=65 mm, T=–15° to 90°, R=360° continuous) |
| Standard Detectors | ETD (high-vacuum SE), LVD (low-vacuum SE), GSED (ESEM SE), IR CCD camera in chamber |
| Brand | BRIGHT |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Cratos W50 |
| Instrument Type | Microhardness Tester |
| Test Force Range | 10–1000 gf (0.098–9.80 N) |
| Hardness Range | 1–2967 HV |
| Measurement Mode | HV/HK |
| Loading Method | Closed-Loop Sensor-Controlled Auto-Loading/Holding/Unloading |
| Indentation Imaging | Integrated 1.3 MP CCD Camera with Real-Time Dynamic View |
| X-Y Motorized Stage | 120 × 120 mm Platform, 25 × 25 mm Travel, 0.003 mm Step Accuracy |
| Resolution | 0.025 µm |
| Dwell Time | 0–60 s |
| Standards Compliance | ISO 6507, ASTM E384, JIS Z2244, GB/T 4340.2 |
| Brand | Gatan |
|---|---|
| Origin | USA |
| Model | ALTO 1000 |
| Sample Temperature Range | −210 °C (LN₂ slush) to +50 °C |
| SEM Cold Stage Operating Range | −185 °C to +50 °C |
| Cold Stage Stability | ±1 °C |
| Pre-chamber Base Pressure | <1×10⁻³ mbar |
| Integrated LN₂ Slush Station | Yes (ALTO 1000D/E) |
| Vacuum Transfer Device (VTD) | Yes (ALTO 1000D/E) |
| Cryo-Fracture Knife | Standard |
| Sputter Coater | Optional (ALTO 1000E, magnetron-based, multi-metal compatible) |
| Control Interface | Dedicated compact keypad with real-time parameter display |
| Interlock System | Full electro-mechanical interlocking with SEM communication |
| Brand | Thermo Fisher |
|---|---|
| Origin | Czech Republic |
| Model | Talos L120C TEM |
| Accelerating Voltage | 120 kV |
| Point Resolution | < 0.37 nm |
| Line Resolution | 0.204 nm |
| Magnification Range (TEM) | 25× – 650,000× |
| Magnification Range (STEM) | 200× – 2.2 M× |
| Alpha Tilt Range (Standard Holder) | −90° to +90° |
| STEM HAADF Resolution | ≤ 1.0 nm |
| Detector | 4k × 4k Ceta CMOS Camera |
| Brand | Gatan |
|---|---|
| Origin | USA |
| Model | MonoCL4 |
| Manufacturer | Gatan, Inc. |
| Detector Type | Parabolic Mirror Collection with Direct-Coupled Czerny-Turner Monochromator |
| Spectral Range | 185–850 nm |
| Spectral Resolution | Adjustable via Micrometer Slit (Typical FWHM < 1.5 nm at 500 nm) |
| Collection Efficiency | Optimized via Diamond-Turned Parabolic Mirror (75 mm retractable stroke) |
| Detection | PMT with Integrated Preamplifier |
| Software | DigitalMicrograph® with MonoCL4 Plugin |
| Compliance | Fully Compatible with SEM/TEM/EPMA Platforms |
| Brand | Thermo Fisher |
|---|---|
| Origin | Czech Republic |
| Model | Talos F200X S/TEM |
| Accelerating Voltage | 200 kV (standard configuration) |
| Resolution | <0.12 nm TEM point resolution, <0.16 nm STEM HAADF resolution |
| EDS System | Super-X with four integrated silicon drift detectors (SDDs) |
| Camera | Ceta 16M CMOS, 25 fps at 512 × 512 |
| Stage | Piezo-driven high-precision stage with sub-nanometer stability |
| Software | Thermo Scientific Velox S/TEM Platform (FDA 21 CFR Part 11 compliant audit trail option available) |
| Brand | Gatan |
|---|---|
| Origin | USA |
| Model | PECS II 685 |
| Ion Source | Two rare-earth magnet-equipped Penning ion guns (maintenance-free) |
| Beam Energy Range | 100 eV – 8.0 keV |
| Beam Current Density | 10 mA/cm² (peak) |
| Beam Diameter Control | Via gas flow or discharge voltage |
| Sample Capacity | Ø ≤ 32 mm, H ≤ 15 mm |
| Polishing Angle Adjustment | ±10° per gun, independently adjustable |
| Dual-Beam Modulation | Single- or dual-beam angular modulation |
| Sample Rotation | 1–6 rpm, continuously variable |
| Cooling | Liquid nitrogen-cooled stage |
| Vacuum System | 80 L/s turbomolecular pump + dual-stage diaphragm pump |
| Base Pressure | ≤ 5 × 10⁻⁶ Torr |
| Operating Pressure | ≤ 8 × 10⁻⁵ Torr |
| Vacuum Gauge | Cold-cathode gauge (main chamber), solid-state gauge (foreline) |
| Load Lock | Whisperlok™ airlock technology (< 1 min exchange, no main chamber vent) |
| User Interface | 10-inch color touchscreen with recipe-based operation |
| Compliance | Designed for GLP-compliant lab environments |