Kipp & Zonen
Filter
Showing 1–30 of 60 results
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | Brewer MkIII Spectrophotometer |
| Measurement Principle | Double-monochromator UV spectrophotometry with PMT detection |
| Wavelength Range | 286.5–363 nm |
| Spectral Resolution | 0.6 nm |
| Wavelength Stability | ±0.01 nm over full operating temperature range |
| Power Supply | 230 VAC or 115 VAC / Optional DC input |
| Operating Temperature | −20 °C to +50 °C (−50 °C to +50 °C with optional cold-weather enclosure) |
| Measured Parameters | Total Ozone Column (TOC), SO₂ Column, Spectral UV Irradiance (286.5–363 nm), UVA (315–400 nm), UVB (280–315 nm), UVE (250–260 nm), UV Index (UVI) |
| Compliance | Designed to meet WMO/GAW reference instrument requirements for ground-based UV and ozone monitoring |
| Sample Compatibility | Direct solar irradiance (direct sun, zenith sky, and diffuse sky modes) |
| Software Interface | PC-based control with 24/7 autonomous operation capability, remote telemetry support |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CSD3 |
| Spectral Range | 400–1100 nm |
| Operating Temperature | -40 to +70 °C |
| Sunshine Signal Output | 1 ± 0.1 V (for direct irradiance > 120 W/m²) |
| Accuracy | >90% (monthly sunshine hours) |
| Accuracy | >90% (clear-sky direct signal) |
| Analog Output | 1 mV/(W/m²) |
| Long-term Drift | <2 %/year |
| Thermal Response | <0.1 °C |
| Response Time | <1 ms |
| Power Supply | 12 VDC |
| Integrated Heater | Yes |
| Desiccant Indicator | Visual humidity indicator |
| Connector | Waterproof M12 plug/socket |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CSD3 |
| Spectral Range | 400–1100 nm |
| Operating Temperature | −40 to +70 °C |
| Sunshine Signal Output | 1 ± 0.1 V (for direct irradiance > 120 W/m²) |
| Accuracy | >90% (monthly sunshine hours) |
| Accuracy | >90% (clear-sky direct signal) |
| Analog Output | 1 mV/(W/m²) |
| Long-term Drift | <2 %/year |
| Temperature Response | <0.1 °C |
| Response Time | <1 ms |
| Power Supply | 12 VDC |
| Built-in Heater | Yes |
| Desiccant Indicator | Integrated humidity indicator |
| Cable Connector | Waterproof IP68-rated mating connector |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Imported |
| Model | CM4 |
| Operating Temperature Range | -40 °C to +150 °C |
| Irradiance Measurement Range | 0 to 4000 W/m² |
| Spectral Range | 305–2800 nm |
| Response Time (95%) | < 5 s |
| Nonlinearity | < ±0.5 % of reading |
| Zero Offset (Thermal, 5 K/h) | < ±5 W/m² |
| Tilt Dependence | < ±1 % (0–90°) |
| Calibrated Against ISO 9060 | 2018 Secondary Standard |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP11 |
| Measurement Principle | Thermopile-based Pyranometer (ISO 9072-1 Secondary Standard) |
| Spectral Range | 305–2800 nm |
| Response Time (95%) | < 5 s |
| Zero Offset (Thermal, 5 K/h) | ±7 W/m² |
| Non-linearity | < ±0.5 % (0–1000 W/m²) |
| Tilt Error | < ±1 % (up to 80°) |
| Operating Temperature | −40 °C to +80 °C |
| Calibration Traceability | NIST-traceable via Kipp & Zonen Calibration Laboratory |
| Compliance | ISO 9060:2018 Class C (formerly Secondary Standard), IEC 61724-1:2021 Annex A |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP6 |
| Measurement Principle | Thermopile-based Pyranometer Pair (Upward- and Downward-Facing) |
| Output Signal | Analog mV per W/m² |
| Spectral Range | 305–2800 nm |
| Response Time (95%) | < 5 s |
| Operating Temperature | –40 to +80 °C |
| IP Rating | IP67 |
| Cosine Response Error | ±5 % (up to 70° zenith angle) |
| Azimuth Error | < 0.2 % |
| Calibration Traceability | ISO/IEC 17025-accredited laboratory (NIST-traceable) |
| Compliance | ISO 9060:2018 Class C (Secondary Standard), WMO Guide to Instruments and Methods of Observation (CIMO), ASTM E892 |
| Brand | Kipp & Zonen |
|---|---|
| Model | CNR4 |
| Measurement Principle | Four-Component Thermopile-Based Net Radiometry |
| Sensor Integration | Integrated 10 kΩ Thermistor and Pt-100 Temperature Sensors |
| Optional Accessories | Solar Radiation Shield, Heater-Ventilation Unit (HVU) for Fouling Mitigation |
| Compliance | ISO 9060:2018 (Secondary Standard), WMO Guide to Meteorological Instruments and Methods of Observation |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CSD3 |
| Measurement Principle | Threshold-based direct solar irradiance detection (≥120 W/m²) |
| Operating Temperature Range | –40 °C to +70 °C |
| IP Rating | IP67 |
| Housing Material | Anodized aluminum with tempered glass tube |
| Desiccant Indicator | Integrated humidity indicator window |
| Service Access | Quick-release waterproof connector |
| Compliance | WMO Guide to Instruments and Methods of Observation (CIMO Guide), ISO 9060:2018 Class C (for pyranometer-coupled operation) |
| Brand | Kipp & Zonen |
|---|---|
| Model | NR Lite2 |
| Measurement Principle | Thermopile-based Single-Component Net Radiation Sensor |
| Spectral Range | 0.3–100 µm |
| Operating Temperature | −40 to +80 °C |
| Output Signal | 0–25 mV (analog, proportional to net radiation in W/m²) |
| Sensitivity | ~5 µV/(W/m²) typical |
| Response Time | < 1 s (95%) |
| Zero Offset (Thermal) | < ±5 W/m² |
| Zero Offset (Solar) | < ±2 W/m² |
| Field of View | 180° (hemispherical) |
| Housing Material | Anodized aluminum with anti-stick hydrophobic coating |
| Cable Length | 5 m standard (shielded, twisted-pair) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Imported |
| Model | PQS1 |
| Output Signal | 0–2.5 V analog (with integrated amplifier) |
| Cable Length | Standard 5 m (optional 15 m) |
| Spectral Range | 400–700 nm (McCree-defined PAR) |
| Cosine Response Error | < ±3% at 75° zenith angle |
| Operating Temperature | –40 °C to +70 °C |
| IP Rating | IP68 |
| Housing Material | Anodized aluminum with quartz diffuser |
| Compliance | ISO 9047, ASTM E2847, WMO Guide to Meteorological Instruments and Methods of Observation |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Imported (Netherlands) |
| Model | SUV5 |
| Measurement Range | Total UV Irradiance (280–400 nm) |
| Output Options | RS-485 Modbus® RTU digital interface |
| Analog Outputs | 4–20 mA or 0–1 V |
| Temperature Compensation | Internal linearized correction over full operating range (-40 to +70 °C) |
| Desiccant Lifetime | ≥10 years (maintenance-free operation) |
| Housing | Anodized aluminum, IP67 rated |
| Spectral Response | Cosine-corrected, ±5% angular response up to 75° zenith angle |
| Stability | <±1 %/year (typical drift) |
| Brand | Kipp & Zonen |
|---|---|
| Model | SUVA / SUVB / SUV-E |
| Spectral Range (SUVA) | 315–400 nm |
| Spectral Range (SUVB) | 280–315 nm |
| Spectral Range (SUV-E) | Erythemal Action Spectrum (CIE 1987) weighted |
| Output Options | 0–1 V analog + RS-485 Modbus® RTU digital |
| Directional Response Error | < ±2 % (10° to 80° zenith angle) |
| Temperature Dependence | < ±0.1 %/°C (with integrated thermistor compensation) |
| Power Consumption | < 1.5 mA @ 12 VDC |
| Operating Temperature | –40 °C to +80 °C |
| IP Rating | IP68 |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP6 |
| ISO 9060 | 1990 Classification: First Class |
| Spectral Range (50% points) | 285–2800 nm |
| Thermal Offset (at 200 W/m²) | <12 W/m² |
| Temperature Response Drift | <4% (−10 °C to +40 °C) |
| Non-stability (annual) | <1% |
| Non-linearity (100–1000 W/m²) | <1% |
| Tilt Error (0–90°, 1000 W/m²) | <1% |
| Leveling Accuracy | <0.1° |
| Response Time (63%) | <6 s |
| Response Time (95%) | <18 s |
| Max. Irradiance | 2000 W/m² |
| Sensitivity | 5–20 µV/W/m² |
| Impedance | 20–200 Ω |
| Output Signal (0–1500 W/m²) | 0–30 mV |
| Spectral Selectivity (350–1500 nm) | <3% |
| Field of View | 180° |
| Operating Environment | −40 °C to +80 °C, 0–100% RH |
| Ingress Protection | IP67 |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | Brewer MkIII |
| Wavelength Range | 286.5–363 nm |
| Spectral Resolution | 0.6 nm |
| Wavelength Stability | ±0.01 nm (over full operating temperature range) |
| Detector | Photomultiplier Tube (PMT) |
| Optical Design | Dual Monochromator |
| Power Supply | 230 VAC or 115 VAC |
| Operating Temperature | −20 °C to +50 °C (−50 °C to +50 °C with optional cold-weather housing) |
| Measured Parameters | Total Ozone Column, SO₂ Column, Spectral UV Irradiance (UVA, UVB, UVE), UV Index (UVI) |
| Brand | Kipp & Zonen |
|---|---|
| Model | Brewer MkIII |
| Optical Design | Dual Monochromator |
| Wavelength Range | 286–363 nm (Ozone & SO₂ measurement bands) |
| Stray Light Rejection | <1×10⁻⁷ (typical) |
| Tracking System | Dual-axis solar tracker with azimuth/elevation control |
| Data Acquisition | PC-controlled via RS-232/USB, 24/7 unattended operation capable |
| Compliance | Meets WMO/GAW requirements for total ozone and UV spectral irradiance monitoring |
| Software | GW-Basic v3.75f (Kipp & Zonen validated, firmware-integrated) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CA2 |
| Spectral Range | 0.3–3 µm (with quartz window) / 0.2–50 µm (bare detector) |
| Sensitivity | 7–20 µV/W/m² |
| Impedance | 20–200 Ω |
| Output Range | 0–30 mV |
| Maximum Irradiance | 2000 W/m² |
| Response Time (63%) | < 6 s |
| Response Time (95%) | < 18 s |
| Operating Temperature | −40 °C to +80 °C |
| Relative Humidity | 0–100 % non-condensing |
| Power Supply | 12 VDC |
| Mounting Rod | 170 mm × 10 mm diameter |
| Field of View (90% energy acceptance) | 20° |
| Housing Material | Brass with conical reflector and removable quartz window |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CGR4 / SGR4 |
| Spectral Range (CGR4) | 4500–42000 nm |
| Spectral Range (SGR4) | 4400–50000 nm |
| Sensitivity | 5–15 µV/W/m² |
| Response Time | 18 s |
| Window Heating Offset (CGR4) | < 4 W/m² |
| Zero Offset B | < 2 W/m² |
| Temperature Dependence of Sensitivity (−20 to +50 °C) | < 1 % |
| Operating Temperature Range | −40 to +80 °C |
| Net Irradiance Range | −250 to +250 W/m² |
| Field of View | 180° |
| Non-linearity Error | < 1 % |
| Analog Output (SGR4) | 4–20 mA / 0–1 V (mV/W·m²) |
| Digital Output (SGR4) | 2-wire RS-485 Modbus® |
| Power Supply (SGR4) | 5–30 VDC |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CGR4 |
| Pricing | Upon Request |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Germany |
| Model | CHM15K |
| Measurement Range | 5 m to 15,000 m |
| Laser Wavelength | 1064 nm |
| Laser Class | 1M (per DIN EN 60825-1:2007) |
| Power Supply | 230 VAC ±10%, 250 W (standard), 800 W (heating mode) |
| Operating Temperature | −40 °C to +50 °C |
| Enclosure Rating | IP65 |
| Dimensions | 500 × 500 × 1550 mm |
| Weight | 70 kg (130 kg with packaging) |
| Data Output Formats | NetCDF, ASCII, XML |
| Communication Interfaces | RS485, Ethernet (LAN), optional RS232 / modem |
| Sampling Frequency | 100 MHz |
| Vertical Resolution | 15 m (full range), 5 m (0–150 m) |
| Minimum Detection Height | 5 m |
| Pulse Repetition Rate | 5–7 kHz |
| Measurement Cycle | Adjustable from 2 s to 600 s |
| Safety Compliance | EN 61326-1, EN 61010-1, ISO 10109-11 |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CHP1 / SHP1 |
| Spectral Range | 200–4000 nm |
| Sensitivity | 7–14 µV/W/m² |
| Response Time (63%) | < 5 s (CHP1), < 0.7 s (SHP1) |
| Response Time (95%) | < 2 s (SHP1) |
| Zero Offset (5 K/h temp. change) | < 1 W/m² |
| Temperature Dependence of Sensitivity | < 0.5 % (-20 to +50 °C for CHP1 |
| Field of View | 5 ± 0.2° |
| Operating Temperature | -40 to +80 °C |
| Non-linearity Error | < 0.2 % |
| Maximum Irradiance | 4000 W/m² |
| ISO 9060 | 2018 Classification: Secondary Standard, Spectral Responsivity Class B |
| Output Options | CHP1 — 10 kΩ thermistor + Pt-100 |
| Power Supply | 5–30 VDC (SHP1), polarity-reversal protected |
| Internal Heating | Low-power, non-interfering with detector thermal stability |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CHP1 |
| Price | Upon Request |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CM4 |
| Spectral Range | 300–2800 nm |
| Sensitivity | 4–10 µV/W/m² |
| Response Time | < 8 s |
| Zero-Offset A | < 4 W/m² |
| Zero-Offset B | < 15 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 20 W/m² |
| Temperature Dependence of Sensitivity (-20 °C to +150 °C, over any 50 °C interval) | < 3 % |
| Operating Temperature Range | -40 °C to +150 °C |
| Maximum Irradiance | 4000 W/m² |
| Field of View | 180° |
| Integrated Pt-100 Temperature Sensor | Yes |
| Internal Class I Temperature Compensation | Yes |
| High-Temperature Signal Cable Length | 10 m |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CMP Series |
| Output Signal | ~10 mV per 1000 W/m² (typical) |
| Calibration | Individually calibrated with traceable certificate |
| Power Requirement | None (passive thermopile sensor) |
| Desiccant Life | ≥10 years (CMP3/CMP10 integrated) |
| Compliance | ISO 9060:2018 Class C (formerly Secondary Standard),符合WMO Guide to Meteorological Instruments and Methods of Observation |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands (manufactured in Vlaardingen) |
| Model | CMP3 / CMP6 / CMP11 / CMP21 / CMP22 |
| ISO 9078 Classification | Secondary Standard (CMP3, CMP11, CMP21, CMP22), First Class (CMP6) |
| Response Time (95%) | 18 s (CMP3/CMP6), 5 s (CMP11/CMP21/CMP22) |
| Thermal Offset (200 W/m²) | ±15 to ±3 W/m² |
| Temperature Offset (5 K/h) | ±5 to ±1 W/m² |
| Long-term Stability (annual) | ±1% to ±0.5% |
| Non-linearity (0–1000 W/m²) | ±2.5% to ±0.2% |
| Directional Error (80°, 1000 W/m²) | ±20 to ±5 W/m² |
| Spectral Range (50% points) | 310–2800 nm (CMP3/CMP6), 200–3600 nm (CMP11/CMP21/CMP22) |
| Max. Irradiance | 2000 W/m² (CMP3/CMP6/CMP11), 4000 W/m² (CMP21/CMP22) |
| Sensitivity | 5–20 µV/(W/m²) (CMP3), 7–14 µV/(W/m²) (CMP6/CMP11/CMP21/CMP22) |
| Output Signal | 0–15 mV |
| Operating Temperature | −40 to +80 °C |
| Tilt Accuracy | ±3% to ±0.2% |
| Leveling Accuracy | 1° (CMP3), 0.5° (CMP6/CMP11), 0.1° (CMP21/CMP22) |
| Optional Cable Lengths | 10 m (standard), 25 m, 50 m |
| Optional Temperature Sensor | 10 kΩ thermistor or PT-100 (CMP21/CMP22) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP10 |
| Spectral Range | 285–2800 nm |
| Sensitivity | 7–14 µV/W/m² |
| Response Time | < 5 s |
| Zero Offset A | < 7 W/m² |
| Zero Offset B | < 2 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 10 W/m² |
| Temperature Dependence of Sensitivity (−10 °C to +40 °C) | < 1 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Irradiance | 4000 W/m² |
| Field of View | 180° |
| Key | Brand: Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP11 |
| Spectral Range | 285–2800 nm |
| Sensitivity | 7–14 µV/W/m² |
| Response Time (63%) | < 1.66 s |
| Zero Offset A | < 7 W/m² |
| Zero Offset B | < 2 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 10 W/m² |
| Temperature Dependence of Sensitivity (−10 °C to +40 °C) | < 1 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Irradiance | 4000 W/m² |
| Field of View | 180° |
| Output Signal | 0–20 mV (passive, no power required) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP21 |
| Spectral Range | 285–2800 nm |
| Sensitivity | 7–14 µV/W/m² |
| Response Time | 5 s |
| Zero Offset A | < 7 W/m² |
| Zero Offset B | < 2 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 10 W/m² |
| Temperature Dependence of Sensitivity (−20 °C to +50 °C) | < 1 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Solar Irradiance | 4000 W/m² |
| Field of View | 180° |
| Output Signal | 0–20 mV (passive, no power required) |
| Brand | KIPP & ZONEN |
|---|---|
| Origin | Netherlands |
| Model | CMP22 Pyranometer |
| Spectral Range | 200–3600 nm |
| Sensitivity | 7–14 µV/W/m² |
| Response Time (95%) | 5 s |
| Zero-Offset A (thermal, 5 K/h) | < 3 W/m² |
| Zero-Offset B (nighttime, 200 W/m² net IR) | < 1 W/m² |
| Directional Error (up to 80° zenith, 1000 W/m² beam) | < 5 W/m² |
| Temperature Dependence of Sensitivity (−20 °C to +50 °C) | < 0.5 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Irradiance | 4000 W/m² |
| Field of View | 180° (2π steradian) |
| Dome Material | High-Purity Fused Quartz |
| Integrated Level | Top-Mounted Bubble Vial |
| Desiccant System | Threaded Desiccant Cartridge with Refill Kit Included |
| Cable | Yellow UV-Stable PVC Cable with IP68 Waterproof Connector (pre-wired lengths optional) |
| Key | Brand: Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP22 |
| Spectral Range | 200–3600 nm |
| Sensitivity | 7–14 µV/W/m² |
| Response Time | 5 s |
| Zero Offset A | < 3 W/m² |
| Zero Offset B | < 1 W/m² |
| Directional Error (up to 80°, 1000 W/m² beam) | < 5 W/m² |
| Temperature Dependence of Sensitivity (−20 °C to +50 °C) | < 0.5 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Irradiance | 4000 W/m² |
| Field of View | 180° |
| Output Signal | 0–20 mV (passive, no power required) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CMP3 |
| Spectral Range | 300–2800 nm |
| Output Signal | 0–55 mV (passive, no power required) |
| Sensitivity | 10 µV/W/m² (typical), 5–20 µV/W/m² (range) |
| Response Time (95%) | <18 s |
| Zero Offset A (thermal) | <15 W/m² |
| Zero Offset B (nighttime cooling) | <5 W/m² |
| Directional Error (up to 80° zenith, 1000 W/m² beam) | <20 W/m² |
| Temperature Dependence of Sensitivity (−10 °C to +40 °C) | <4 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Irradiance | 2000 W/m² |
| Field of View | 180° (2π steradian, hemispherical) |
| Calibration Compliance | ISO 9060:2018 Secondary Standard |