MCL Think Nano
Filter
Showing 1–30 of 75 results
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Custom & OEM Solutions |
| Product Type | Motorized Translation Stage |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | MadAFM™ |
| Instrument Type | Material-Grade AFM |
| Positional Detection Noise | <0.15 nm RMS |
| Max Sample Size | 50 mm × 50 mm × 40 mm |
| XY Sample Stage Travel | 25 mm |
| Z Focus & Head Travel | 50 mm |
| Closed-Loop Nanopositioner Range (XY) | 30/65/100 µm |
| Z Nanopositioner Range | 15/30 µm |
| Nanopositioner Resolution (30 µm range) | 0.03 nm |
| Nanopositioner Noise Floor (peak-to-peak) | 2.7 pm |
| Optical Alignment | 635 nm Class II laser + 1.6 MP coaxial CMOS camera |
| Software | AFMView®-OD (USB 2.0 interface, Windows 8.1/10/11) |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MadPLL® |
| Price Range | USD $14,000 – $72,000 (based on configuration) |
| Positional Detection Noise | 0.15 nm RMS |
| Sample Diameter Limit | <15 mm |
| XY Scan Range (with compatible stages) | up to 200 µm |
| Z-Range (with Nano-OP30) | 30 µm (closed-loop), 100 µm (open-loop) |
| PLL Frequency Lock Range | 10–100 kHz |
| Phase Shift Resolution | <0.1° |
| Demodulation Bandwidth | 3 kHz |
| PCC Compensation Range | ±50 pF |
| Operating Systems | Windows 7/10/11 (32/64-bit), LabVIEW 2015+ compatible |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nano-Mini |
| Drive Type | Motorized (Piezo-Driven) |
| Stage Type | Flexure-Guided Closed-Loop Translation Stage |
| Body Material | Titanium or Invar |
| Motion Range | 10 μm |
| Resolution | 0.02 nm |
| Resonant Frequency (no load) | 1.5 kHz ±20% |
| Resonant Frequency (50 g load) | 650 Hz ±20% |
| Stiffness | 1.0 N/μm ±20% |
| Angular Deviation (Roll/Pitch) | ≤1 μrad |
| Angular Deviation (Yaw) | ≤2 μrad |
| Max Horizontal Load | 0.5 kg |
| Max Vertical Load | 0.15 kg |
| Position Sensing Technology | PicoQ® Integrated Capacitive Sensor |
| Controller Compatibility | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-View®/M Series |
| Type | Motorized Translation Stage |
| Positioning Architecture | Hybrid Manual Micropositioning + Piezoelectric Nanopositioning (Closed-Loop) |
| Axes | XY or XYZ |
| Nanopositioner Range | Up to 300 µm per axis |
| Nanopositioner Resolution | 0.1–0.6 nm (model-dependent) |
| Micropositioner Range | 25 mm (X/Y), Graduation: 1 µm vernier |
| Stiffness | 1.0 N/µm |
| Angular Deviation (θ roll/pitch/yaw) | ≤1 µrad / ≤1 µrad / ≤3 µrad |
| Max Horizontal Load (nanopositioner) | 0.5 kg (low-profile), 100 g (high-speed) |
| Controller | Nano-Drive® |
| Software Compatibility | LabVIEW API, Native SDK |
| Microscope Compatibility | Olympus IX/IX2, Nikon TE2000/Ti, Leica DMI, Zeiss Axiovert/Axio Observer, RM21™ Platform |
| Sensor Technology | Proprietary PicoQ® Absolute Position Sensing |
| Mounting Options | Standard 1/4"-20 (1" grid) or M6 (25 mm grid) threaded breadboard interface |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | MicroStage Automated Micropositioner |
| Motion Axes | XY |
| Travel Range | 25 mm per axis |
| Encoder Resolution (optional) | 20 nm |
| Step Size | 95 nm |
| Max Speed | 4 mm/sec |
| Controller | Micro-Drive™ USB |
| LabVIEW Compatibility | Yes |
| Load Capacity (horizontal) | 5 kg |
| Body Material | Aluminum |
| Microscope Compatibility | Olympus IX/IX2, Nikon TE2000/Ti, Leica DMI, Zeiss Axiovert/Axio Observer, RM21™ Platform |
| Software Interface | USB 2.0 |
| Control Options | PC-driven motion commands, optional wireless joystick |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | C-Focus™ System |
| Product Type | Motorized Precision Translation Stage for Objective Lens Positioning |
| Motion Range | 100 µm |
| Resolution | 0.2 nm |
| Resonant Frequency | 500 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Max Recommended Load | 0.5 kg |
| Sensor Technology | Proprietary PicoQ® capacitive position sensing |
| Control Interface | 16-bit USB digital interface (included) |
| Closed-Loop Architecture | Yes |
| Compatibility | Universal retrofit for all upright and inverted microscopes via standard threaded adapters |
| Actuation Method | Piezo-driven lens positioner (Nano-F100S) |
| Sub-nanometer Positioning Capability | Yes |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Cyto-Lite™ |
| Laser Wavelengths | 405 nm, 532 nm, 640 nm |
| Output Power | 10 mW (405 nm & 640 nm), 20 mW (532 nm) |
| Control Interface | USB 2.0 |
| Modulation | Onboard DDS sine-wave generator + 16-bit DAC per channel |
| Feedback Modes | Constant current or constant optical power |
| Power Supply | Three independent linear regulators |
| Protection Features | Overcurrent protection, watchdog circuitry, ESD protection per channel |
| Fiber Delivery | Single-mode PM fiber, collimated free-space output optional |
| Compliance | CE, RoHS, FDA 21 CFR Part 1040.10 (Laser Product Safety) |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Cyto-Lite™ |
| Laser Wavelengths | 405 nm, 532 nm, 640 nm |
| Output Power | 10 mW (405 nm & 640 nm), 20 mW (532 nm) |
| Control Interface | USB 2.0 |
| Modulation | Onboard DDS sine-wave generator + 16-bit DAC per channel |
| Feedback Modes | Constant current or constant optical power |
| Power Supply | Three independent linear regulators with ESD and overcurrent protection |
| Fiber Delivery | Single-mode PM fiber, collimated free-space option available |
| Compliance | CE, RoHS, FDA 21 CFR Part 11–ready software architecture |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Optical Translation Stage |
| Model | Mad-Deck™ |
| Drive Type | Motorized (Stepper-Based) |
| Motion Axes | X, Y, Z (All Motorized) |
| Linear Encoder Resolution (Optional) | 50 nm |
| Micropositioning Step Size | 95 nm |
| Max. Speed | 1.5 mm/sec |
| Native Accuracy | 1.0 µm |
| Native Repeatability | < 100 nm |
| Body Material | Aluminum |
| Controller | Micro-Drive™ |
| Interface | Bidirectional USB |
| Software Compatibility | LabVIEW-based GUI, Custom VI Development, Third-Party Integration |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | MadMotor™-UHV |
| Product Type | Motorized Translation Stage |
| Travel Range | 10 mm per axis |
| Sensor Resolution (optional) | 500 nm |
| Minimum Step Size | 100 nm |
| Maximum Speed | 1 mm/s |
| UHV Compatibility | 1 × 10⁻¹¹ mbar |
| Bakeable Temperature | 150 °C |
| Recommended Max. Load | 6 kg |
| Body Material | Aluminum |
| Motor Type | MadMotor™ Piezo Motor |
| Controller | Mad-Drive™ DSP Controller (1/2/3-axis, USB interface, LabVIEW-compatible) |
| Software Interface | MadMotor™ DLL with stepper-motor-like abstraction |
| Mounting | Flange-mount or freestanding |
| Compliance | Designed for GLP/GMP-aligned UHV system integration |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Manual MicroStage Series |
| Product Type | Manual Translation Stage |
| Travel Range (X/Y) | 25 mm |
| Graduation | 10 µm |
| Vernier Resolution | 1 µm |
| Body Material | Aluminum |
| Locking Mechanism | Integrated Continuous Pre-Loaded Position Lock (10 N per axis) |
| Compatibility | Olympus IX/IX2, Nikon TE2000/Ti, Leica DMI, Zeiss Axiovert/Axio Observer inverted microscopes |
| Optional Mounting | Breadboard base with 1/4"-20 (1" grid) or M6 (25 mm grid) threaded holes |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | MCL-MANNZ |
| Product Type | Motorized & Manual Hybrid Translation Stage |
| XY Travel Range | 25 mm |
| Z Travel Range | 200 µm |
| XY Resolution (Manual) | 1 µm (vernier), 10 µm (main scale) |
| Z Resolution | 0.4 nm |
| Z Resonant Frequency | 250 Hz ±20% |
| Max Horizontal Load (Z-axis) | 0.5 kg |
| Closed-Loop Control | Yes (PicoQ® absolute position sensing) |
| Controller | Nano-Drive® C |
| Interface | USB 2.0, 0–10 V analog input |
| Compatible Microscopes | Olympus IX, Nikon TE/Ti, Leica DMI, Zeiss Axiovert/Axio Observer |
| Mounting Compatibility | 3″ (75 mm) slides, 35 mm Petri dishes, inverted microscopes, optical tables |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-3D200 |
| Motion Range (XYZ) | 200 µm |
| Resolution | 1 nm |
| Resonant Frequency (X/Y) | 150 Hz ±20% |
| Resonant Frequency (Z) | 500 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Max. Horizontal Load | 0.5 kg |
| Max. Vertical Load | 0.2 kg |
| Body Material | Aluminum |
| Controller | Nano-Drive® |
| Control Type | Closed-loop |
| Guidance Mechanism | True Flexure |
| Drive Type | Piezoelectric |
| Product Category | Motorized Translation Stage |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-3D500 |
| Motion Range (XYZ) | 500 µm |
| Resolution | 1 nm |
| Resonant Frequency (X/Y) | 150 Hz ±20% |
| Resonant Frequency (Z) | 200 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Max. Horizontal Load | 0.5 kg |
| Max. Vertical Load | 0.2 kg |
| Body Material | Aluminum |
| Control Architecture | Closed-loop with integrated Nano-Drive® controller |
| Center Aperture | 12.7 mm (0.5 in) diameter |
| Guidance Mechanism | Monolithic flexure design |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-Align3 Series |
| Product Type | Motorized Precision Nanopositioning Stage |
| Motion Axes | Z, θX, θY |
| Profile Height | 0.8 in (20.3 mm) |
| Central Aperture | 2.6 in × 2.6 in (66 mm × 66 mm) |
| Z Travel Range | 100 µm or 200 µm |
| Angular Range (θX/θY) | 2 mrad or 4 mrad |
| Closed-Loop Resolution (Z/θ) | 0.2 nm / 4 nrad (Nano-Align3-100) or 0.4 nm / 8 nrad (Nano-Align3-200) |
| Resonant Frequency | 600 Hz ±20% (100 µm version) or 450 Hz ±20% (200 µm version) |
| Stiffness | 1.0 N/µm |
| Max Horizontal Load | 0.5 kg |
| Max Vertical Load | 0.2 kg |
| Body Materials | Aluminum, Titanium, or Invar |
| Controller | Nano-Drive® or Nano-Drive®85 |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-Align5 Series |
| Type | Motorized 5-Axis Nanopositioning Stage (XYZ + θX + θY) |
| Travel Range (XYZ) | 100/200/300 µm |
| Angular Range (θX/θY) | up to 3.3/4.5 mrad |
| Resolution (XYZ) | 0.2–0.6 nm |
| Resolution (θX/θY) | 2.2–9.0 nrad |
| Center Aperture | 66 mm × 66 mm |
| Body Material | Aluminum (standard), optional Invar or Titanium |
| Resonant Frequency | 250–450 Hz |
| Stiffness | 1.0 N/µm |
| Max Load (horizontal) | 0.5 kg |
| Max Load (vertical) | 0.2 kg |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-Align6 Series |
| Product Type | Motorized 6-Axis Nanopositioning Stage |
| Motion Ranges (Nano-Align6-100) | 100 μm × 100 μm × 100 μm × 1.1 mrad × 1.5 mrad × 5 mrad |
| Motion Ranges (Nano-Align6-200) | 200 μm × 200 μm × 200 μm × 2.3 mrad × 3.0 mrad × 5 mrad |
| Resolution (Nano-Align6-100) | 0.2 nm (XYZ), 2.2 nrad (θX), 3.0 nrad (θY), 10 nrad (θZ) |
| Resolution (Nano-Align6-200) | 0.4 nm (XYZ), 4.6 nrad (θX), 6.0 nrad (θY), 10 nrad (θZ) |
| Center Aperture | 35 mm diameter |
| Control | Closed-loop with integrated PicoQ® capacitive sensors |
| Body Materials | Aluminum, Titanium, or Invar |
| Recommended Max Load (horizontal) | 0.5 kg |
| Recommended Max Load (vertical) | 0.2 kg |
| Resonant Frequencies | X (450/400 Hz), Y (350/300 Hz), Z (450/350 Hz), ±20% |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrumentation |
| Model | Nano-Bio Series |
| Product Type | Motorized Translation Stage |
| Motion Range Options | 50 µm × 50 µm, 100 µm × 100 µm, 200 µm × 200 µm, 300 µm × 300 µm |
| Resolution | 0.1–0.6 nm (model-dependent) |
| Closed-Loop Feedback | PicoQ® Integrated Absolute Position Sensing |
| Structural Material | Aluminum (standard), Invar or Titanium (Nano-Bio2M & select models) |
| Resonant Frequency | 200–500 Hz (X/Y axis, model-dependent) |
| Stiffness | 1.0 N/µm |
| Angular Deviation (Roll/Pitch/Yaw) | ≤1 µrad / ≤1 µrad / ≤3 µrad |
| Max Load (Horizontal/Vertical) | 0.5 kg / 0.2 kg |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-BioS Series |
| Motion Range | 100 μm × 100 μm |
| Resolution | 0.2 nm / 0.4 nm / 0.6 nm |
| Closed-Loop Control | Yes |
| Body Material | Anodized Aluminum (standard), Invar or Titanium (optional for 100/200 μm models) |
| Stiffness | 1.0 N/μm |
| Roll/Pitch Angular Deviation | ≤1 μrad |
| Yaw Angular Deviation | ≤3 μrad |
| Max Horizontal Load | 0.5 kg |
| Max Vertical Load | 0.2 kg |
| Resonant Frequency (X) | 400 / 350 / 300 Hz ±20% |
| Resonant Frequency (Y) | 280 / 230 / 180 Hz ±20% |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nano-Cyte® |
| Pricing | Upon Request |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-CZ200 |
| Motion Axis | Z-axis only |
| Travel Range | 200 µm |
| Resolution | 0.4 nm |
| Resonant Frequency | 500 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Max Horizontal Load | 0.5 kg |
| Max Vertical Load | 0.1 kg |
| Body Material | Aluminum |
| Control | Closed-loop with integrated PicoQ® position sensing |
| Optional Center Aperture | Up to 0.25" diameter |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-CZ500 |
| Motion Axis | Z-axis only |
| Travel Range | 500 µm |
| Resolution | 1.0 nm |
| Resonant Frequency | 200 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Max Load (horizontal) | 0.5 kg |
| Max Load (vertical) | 0.1 kg |
| Body Material | Aluminum |
| Control | Closed-loop with integrated PicoQ® position sensor |
| Optional Center Aperture | Up to 0.5 in diameter |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-Drive® Series |
| Type | Motorized Translation Stage Controller |
| Compliance | CE |
| Control Interface | Analog (0–10 V BNC), Optional 16-bit/20-bit USB Digital |
| Feedback | Closed-loop servo with Proportional-Integral (PI) control |
| Bandwidth Selection | Adjustable for stability under high inertial load |
| Form Factor | Benchtop unit or OEM circuit board |
| High-Power Variant | Nano-Drive®85 |
| Software Compatibility | Windows XP/Vista/7 (32/64-bit), LabVIEW-ready, TCSPC synchronization support (ISS option) |
| Regulatory Alignment | Designed for GLP-compliant lab environments |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Type | Motorized Precision Translation Stage |
| Model | Nano-F3D |
| Motion Range (X/Y/Z) | 100 µm |
| Resolution | 0.2 nm |
| Resonant Frequency (X/Y/Z) | 300/200/400 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Max Recommended Load | 0.5 kg |
| Body Material | Aluminum and Brass |
| Compatible Threads | RMS, M25, M26 |
| Control | Closed-loop with proprietary on-axis position sensors |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-F450 |
| Travel Range | 450 µm |
| Resolution | 0.9 nm |
| Resonant Frequency (no load) | 240 Hz ±20% |
| Resonant Frequency (150 g load) | 160 Hz ±20% |
| Resonant Frequency (250 g load) | 130 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Max Recommended Load | 0.5 kg |
| Body Material | Aluminum and Brass |
| Compatible Mounting Threads | RMS, M25, M26 |
| Control Architecture | Closed-loop with PicoQ® capacitive position sensing |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-Gauge™ |
| Type | Motorized Translation Stage |
| Measurement Resolution | 1.5 nm (Nano-Gauge™1) / 5.0 nm (Nano-Gauge™5) |
| Full-Scale Range | 25 mm |
| Output Interface | USB 2.0 (Plug & Play) |
| Probe Loading Range | 1–10 lb/in |
| Probe Tip Options | Hardened steel, sapphire, silicon nitride balls (Ø 0.25–8 mm) |
| Housing Material | Aluminum |
| Dimensions | 63.5 × 79.2 × 42.9 mm |
| Data Acquisition Interval | 50 ms – 60 s |
| Compliance | CE-marked, RoHS-compliant |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-H Series |
| Motion Range | 50 μm × 50 μm or 100 μm × 100 μm |
| Resolution | 0.1 nm (Nano-H50) / 0.2 nm (Nano-H100) |
| Resonant Frequency (X) | 500 Hz ±20% |
| Resonant Frequency (Y) | 250 Hz ±20% |
| Stiffness | 1.0 N/μm |
| Angular Deviation (Roll/Pitch) | ≤1 μrad |
| Angular Deviation (Yaw) | ≤3 μrad |
| Max Load (Horizontal) | 0.5 kg |
| Max Load (Vertical) | 0.2 kg |
| Body Material Options | Aluminum, Invar, Titanium |
| Controller | Nano-Drive® |
| Closed-Loop Position Sensing | PicoQ® Technology |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-HL |
| Motion Axis | Single-Axis |
| Travel Range | 50/100/200 µm |
| Resolution | 0.1–0.4 nm (model-dependent) |
| Load Capacity | 10 kg (horizontal & vertical) |
| Control | Closed-loop with PicoQ® absolute position sensing |
| Body Material | Solid aluminum block (50 mm thick) |
| Resonant Frequency | 450 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-HS Series |
| Type | Motorized Piezoelectric Translation Stage |
| Motion Configurations | XY (Nano-HS2), XYZ (Nano-HS3, Nano-HS3M) |
| Positioning Resolution | 0.01 nm (10 pm) |
| Z-Axis Step Response Time | ≤2 ms |
| Z-Axis Resonant Frequency | 5.0 kHz ±20% |
| XY Resonant Frequency (HS2) | 1.5 kHz ±20% |
| XY Resonant Frequency (HS3) | 1.0 kHz ±20% |
| Max Scanning Frequency | 300 Hz |
| Stiffness (Z-axis) | 8 N/µm |
| Max Horizontal Load | 0.1 kg |
| Max Vertical Load | 0.1 kg |
| Body Materials | Aluminum, Invar, or Titanium |
| Position Noise | <2 pm RMS (all axes) |
| Control Architecture | Closed-loop with integrated PicoQ® absolute position sensors |
| Controller | Nano-Drive® |