PERIC
Filter
Showing 1–30 of 56 results
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Custom Model 11 |
| Pricing | Upon Request |
| Measurement Principle | Infrared Light Scattering |
| Range | 0–5 mg/L |
| Resolution | 0.01 mg/L |
| Adjustable Alarm Threshold | 0.9–2.5 mg/L |
| Communication Interface | RS485 |
| Power Supply | 24 VDC |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Customized Environmental Protection Concierge Service Integrated Platform |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | NL |
| Pricing | Available Upon Request |
| Power Supply | AC 220 V ±15%, with Li-ion backup battery (≥6 h runtime during mains failure) |
| Operating Temperature | −30 °C to +70 °C |
| Communication Interface | RS485 (custom protocol support available) |
| Data Upload Protocol | HJ212 (customizable, e.g., MQTT, Modbus TCP, HTTP RESTful APIs) |
| Digital Inputs | 1 channel |
| Digital Outputs | 1 channel |
| Analog Inputs | 4 channels (0–5 V / 0–20 mA configurable) |
| Local Storage | MicroSD card (up to 32 GB, FAT32 formatted) |
| Network Connectivity | LTE Cat 1 / Cat 4 (4G), with fallback to SMS-based alarm notification |
| Special Functions | Power-loss detection & logging, enclosure tamper detection (door open/close event), automatic battery charging and state-of-charge monitoring |
| Compliance | Meets GB/T 17626 ESD/Surge immunity requirements |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Customized Atmospheric Environment Integrated Supervision Platform |
| Pricing | Available upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | CJJC-3 |
| Quotation | Upon Request |
| Communication | 4G (TCP/UDP/HTTP/MQTT) + RS485 |
| Power Supply | AC 85–265 V / DC 110–370 V |
| Operating Temperature | −30 to +70 °C |
| Electrical Parameters Measured | Phase & total voltage, current, active/reactive power, energy, grid frequency |
| Accuracy Class | Active Energy Class 1 |
| Voltage Input Range | AC 7–265 V (direct) |
| Current Input Range | 0–5 A (direct) |
| Mounting | DIN rail |
| Dimensions (L×W×H) | 92 × 76 × 59 mm |
| Data Upload Protocol | HJ 212 (customizable) |
| Special Functions | Power-on/off alarm, cover-open detection, internal temperature monitoring, built-in antenna & terminal block |
| Enclosure Design | Tamper-resistant, fully integrated wiring |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Custom 2 |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Custom Version |
| Pricing | Upon Request |
| Detection Gases | Hydrogen, Combustible Gases (e.g., CH₄), Oxygen, Ammonia |
| Measurement Ranges | 0–100% LEL (H₂ & combustibles), 0–25% O₂, 0–100 ppm NH₃ |
| Accuracy | ≤±3% FS (H₂ & combustibles), ≤±2% FS (O₂), ≤±5% FS (NH₃) |
| T90 Response Time | ≤30 s (H₂), ≤60 s (combustibles, O₂, NH₃) |
| Certification | CCC (China Compulsory Certification) |
| Design | Explosion-Proof (Ex d IIB T6 Gb), Modular Controller Architecture, Integrated Sampling & Pre-treatment Compatibility |
| Environmental Resistance | Vibration-resistant, Salt Mist Resistant |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Custom10 |
| Pricing | Upon Request |
| Gas Measurement Range | NH₃ (0–10,000 ppm), NO (0–3,000 ppm), NO₂ (0–3,000 ppm), N₂O (0–1,000 ppm), CH₃OH (0–2,000 ppm), CH₂O (0–1,000 ppm), CH₄ (0–30,000 ppm), O₂ (0–24% vol), CO (0–2,000 ppm), CO₂ (0–14% vol), SO₂ (0–1,000 ppm) |
| Accuracy | ≤ ±2% FS for all listed gases |
| Detection Technologies | NDIR, UV-DOAS, TDLAS |
| Application Scope | Dual-fuel diesel, LNG, methanol, and ammonia-fueled marine engines |
| Compliance Support | ASTM D6595, ISO 8178-4, IMO MARPOL Annex VI Tier III test protocols |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Custom Model 8 |
| Quotation | Upon Request |
| Response Time | ≤60 s |
| Measurement Principle | UV Differential Optical Absorption Spectroscopy (UV-DOAS) with Hot-Wet Sampling |
| Detection Target | Monoethanolamine (MEA), Diethanolamine (DEA), and related alkanolamines |
| Range | 0–20 ppm |
| LOD | 200 ppb |
| Accuracy | ≤±5% FS |
| Sample Flow Rate | ≥2 L/min |
| Optical Path Length | ≥7 m |
| Operating Temperature | −5 to 40 °C |
| Operating Humidity | 15–85% RH |
| Preconditioning | Heated Wet Sampling + Multi-Stage Filtration |
| Compliance | Designed for marine GLP-aligned operation |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Custom 9 |
| Pricing | Upon Request |
| Detection Principle | Laser Raman Spectroscopy |
| Target Analytes | Monoethanolamine (MEA), Diethanolamine (DEA) |
| Concentration Range | 0–55% (w/w) |
| Accuracy | ≤ ±1% FS |
| Response Time | ≤ 30 s |
| Operating Temperature | −10 to 50 °C |
| Operating Humidity | 15–85% RH |
| Probe Configuration | In-situ or Extractive |
| System Architecture | Modular (Separated Spectrometer Unit & Immersion Probe) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Custom-1 |
| Pricing | Upon Request |
| Principle | Laser Raman Spectroscopy |
| Form Factor | Portable |
| Detection Range | H₂: 0–100% vol, O₂: 0–20% vol, N₂: 0–100% vol |
| Accuracy | ≤0.3% vol (0–10% range), ≤3% FS (10–100% range) |
| Response Time | Default 30 s, Adjustable |
| Power | Integrated Rechargeable Battery (≥8 h runtime) |
| Dimensions | Approx. 40 × 30 × 25 cm (l×w×h), Luggage-Sized Enclosure |
| Sampling | Built-in Diaphragm Pump with External Gas–Liquid Separator |
| Compliance | Designed for IAEA Safety Standards, NRC Regulatory Guidance (NUREG-0711), and ISO 17025 Traceability Framework |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Custom T |
| Pricing | Upon Request |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Detection Method | Wavelength Modulation Spectroscopy (WMS) with Digital Lock-in Amplification |
| Gas Species | H₂O (dew point), O₂, HF, NH₃, CO, CO₂, H₂S |
| Concentration Ranges | 0–1000 ppm (H₂O), 0–25% vol (O₂), 0–10 ppm (HF), 0–100 ppm (NH₃, CO, CO₂), 0–2% vol (CO₂), 0–100 ppm (H₂S) |
| Accuracy | ±3% FS for all listed gases |
| Detection Limits | 0.1 ppm (H₂O, HF, NH₃, CO, CO₂), 0.1% vol (O₂), 0.01 ppm (H₂S), 0.5 ppm (H₂S — alternate spec) |
| Form Factors | Portable, In-situ Online, Ambient-Temperature & High-Temperature Configurations |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Custom V1 |
| Pricing | Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Custom Model 5 |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Customized 3 |
| Pricing | Available Upon Request |
| Measurement Species | H₂, O₂ |
| Dimensions (L×W×H) | ≤1100×550×2100 mm (including nozzles and mounting brackets) |
| H₂ Range | 0–5% vol |
| Low-range H₂ | 0–0.5% vol |
| O₂ Range | 0–2.5% vol / 0–25% vol (switchable) |
| Low-range O₂ | 0–1% vol |
| H₂ Accuracy | ±2% FS |
| O₂ Accuracy | ±1% FS (for 0–2.5% / 0–25% ranges), ±2% FS (for 0–1% range) |
| Measurement Principles | Tunable Diode Laser Absorption Spectroscopy (TDLAS) for O₂ |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Customized 4 |
| Pricing | Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Customized 7 |
| Quotation | Upon Request |
| Repeatability | 2% F.S. |
| Resolution | 0.01% VOL |
| Response Time | ≤30 s |
| CO₂ Measurement Range | (0–10)% VOL |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Accuracy | ±2% F.S. |
| Operating Ambient Temperature | −20 °C to +55 °C |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Customized-6 |
| Pricing | Available Upon Request |
| Brand | Peric |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Customized Sub-Metering Electricity Monitoring & Regulatory Platform |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Model | DQF |
| Measurement Principle | Thermal Conductivity |
| Range | 0–1% H₂ (v/v) |
| Response Time | ≤2.5 min |
| Accuracy | ±5% FS |
| Alarm Threshold | >0.75% H₂ |
| Power Supply | AC 220 V |
| Power Consumption | ≤10 W |
| Enclosure Rating | Ex d II CT6 |
| Output Signals | 1–5 V DC & 4–20 mA |
| Display | Digital Panel Meter (H₂ %) |
| Alarm Output | Audible/Visual + Relay Contacts |
| Compliance | GB/T 3836.1–2021 (Explosion-Proof), JJG 915–2008 (Calibration Standard for Thermal Conductivity Gas Analyzers) |
| Brand | PERIC |
|---|---|
| Model | DYF |
| Measurement Principle | Catalytic Combustion (Pd-Catalyzed Exothermic Reaction) |
| Measurement Range | 0–1% O₂ |
| Resolution | 0.01% O₂ |
| Response Time (T₉₀) | ≤2.5 min |
| Accuracy | ±5% FS |
| Alarm Threshold | >0.75% O₂ |
| Output Signals | 1–5 V DC, 4–20 mA |
| Display | LED Digital Panel |
| Power Supply | AC 220 V ±10%, 50 Hz ±2.5 Hz |
| Power Consumption | ≤10 W |
| Environmental Operating Range | 0–40 °C, <95% RH |
| Enclosure Rating | Ex d II CT6 (IEC 60079-1 & IEC 60079-2 compliant) |
| Compliance | GB/T 11606–2007, JB/T 8279–1999, GB 3836.1–2010, GB 3836.2–2010 |
| Brand | PERIC |
|---|---|
| Model | EMO-HJV |
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Power Supply | AC 220 V ±10%, with built-in rechargeable battery supporting ≥6 hours operation during power outage |
| Sampling Method | Active pump-driven aspiration with integrated hydrophobic dust/water filter |
| Communication Interfaces | 4G LTE (Cat 1), Ethernet (RJ45), LoRaWAN (optional), RS485 (Modbus RTU) |
| Local Storage | MicroSD card slot (up to 32 GB) |
| Data Upload Protocol | MQTT/HTTP over TLS 1.2 |
| Remote Capabilities | OTA firmware update, remote zero/span calibration, drift compensation algorithm |
| Data Integrity | 断点续传 (Resume-on-Interruption) with local queue buffering |
| Expandability | Optional meteorological module (wind speed/direction, temperature, humidity, pressure, rainfall) |
| Compliance | Designed per IEC 61326-1 (EMC), EN 50270 (gas detection equipment), and aligned with technical requirements of China’s HJ 653–2013 and HJ 93–2013 for ambient air monitoring stations |
| Detection Parameters & Ranges | PM₂.₅ (0–1000 µg/m³, resolution: 1 µg/m³), PM₁₀ (0–1000 µg/m³, resolution: 1 µg/m³), CO (0–12.5 µmol/mol, resolution: 0.01 µmol/mol), SO₂ (0–1000 nmol/mol, resolution: 1 nmol/mol), NO₂ (0–1000 nmol/mol, resolution: 1 nmol/mol), O₃ (0–1000 nmol/mol, resolution: 1 nmol/mol), VOCs (0–50 µmol/mol, resolution: 1 nmol/mol) |
| Sensor Technologies | Optical scattering (PM), electrochemical (CO, SO₂, NO₂, O₃), photoionization detection (PID) for VOCs, NDIR for CO₂ (optional) |
| Brand | PERIC |
|---|---|
| Model | EMO-YC |
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Certification | CCEP, CPA, CMA |
| Measurement Principle | Laser Light Scattering |
| Particle Range | TSP/PM10/PM2.5: 0–10 mg/m³ |
| LOD | 0.001 mg/m³ |
| Accuracy | ±10% |
| Temp. Range | −40–80 °C (±0.3 °C) |
| RH Range | 0–100% RH (±3% RH) |
| Wind Speed | 0–30.0 m/s (0.1 m/s res.) |
| Wind Direction | 0–360° (8-sector) |
| Barometric Pressure | 300–1100 hPa (1 Pa res.) |
| IP Rating | IP54 |
| Power Input | AC 220 V |
| Data Transmission | 4G Cellular + Optional Wired Ethernet |
| Operating Temp. | −20–70 °C |
| Humidity Limit | ≤95% RH non-condensing |
| Brand | PERIC |
|---|---|
| Model | EO-VD |
| Detection Principle | Photoionization Detection (PID) |
| Measurement Target | Total Volatile Organic Compounds (TVOC), including benzene, aliphatic hydrocarbons, and alkanes |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Protection Rating | IP66 |
| Explosion Protection | Ex d IIC T6 Gb |
| Communication Interface | 4G LTE + Ethernet (RJ45) |
| Alarm Output | Visual (LED strobe) + Audible (≥85 dB at 1 m) |
| Data Protocol | HJ 212–2017 (China EPA Standard) |
| Operating Temperature | −10 °C to +55 °C |
| Relative Humidity | ≤93 % RH (non-condensing at 25 °C) |
| Atmospheric Pressure Range | 86–106 kPa |
| Response Time (T90) | ≤20 s |
| Accuracy | ±10 % of Full Scale (FS) |
| Display | High-resolution color LCD (≥3.5″, 320×240 pixels) |
| Sensor Configuration | Triple-sensor simultaneous monitoring (customizable VOC selectivity) |
| Calibration Gas | Isobutylene (default), traceable to NIST or equivalent national standards |
| Typical Measurement Ranges | 0–20, 0–50, 0–200, 0–2000 μmol/mol or 0–50, 0–125 mg/m³ (selectable) |
| Display Resolution | 0.1 or 1 μmol/mol |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Customized FTIR-Based Remote Toxic Gas Detection and Alarm System |
| Pricing | Upon Request |
| Detector Type | Cooled HgCdTe (MCT) |
| Maximum Detection Range | 4.28 km |
| Spectral Resolution | 1.6 cm⁻¹ |
| Spectral Acquisition Rate | 20 Hz |
| Operating Temperature Range | −40°C to +65°C |
| Enclosure Rating | IP66 |
| Dimensions (L×W×H) | 370 × 320 × 500 mm |
| Weight | 28 kg |
| Explosion-Proof Certification | Certified |
| Detectable Gases | ≥10 toxic/hazardous gases (e.g., SF₆, NH₃, HCl, HF, CO, CH₄, VOCs) |
| Minimum Detectable Column Density | 32 mg/m² for SF₆ (at 5°C target-background thermal contrast) |
| Alarm Response Time | ≤1 s |
| Gas Identification Capability | Multi-component analysis under spectral overlap conditions |
| Imaging Mode | Pseudocolor IR gas cloud overlay with visible-light co-registration |
| Calibration | Automated blackbody reference calibration |
| Deployment Options | Fixed-mount or vehicle-mounted |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | G-WA10 |
| Pricing | Upon Request |
| Detection Principles | Electrochemical, Infrared (IR), Catalytic Combustion, Thermal Cracking + IR |
| Supported Gases | >30 toxic, flammable, and corrosive gases including NH₃, NF₃, SiH₄, AsH₃, B₂H₆, PH₃, H₂S, Cl₂, HF, HCl, HBr, SO₂, O₃, CO, NO, O₂, CH₄, C₂H₂, C₂H₄, C₃H₆, H₂, D₂, C₄F₆, CH₃F, CH₂F₂, COS, IPA, TEOS, GeH₄, ClO₂, CH₃ClO₂S |
| Sampling | Integrated diaphragm pump with flow & pressure monitoring and auto-adaptive regulation |
| Sensor Architecture | Modular, hot-swap intelligent sensors with offline calibration capability |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GAF X8-II |
| Pricing | Upon Request |
| Display | 4.3-inch HD TFT LCD |
| Communication | LoRa wireless protocol (sub-GHz ISM band, up to 5 km line-of-sight range) |
| Output Interface | Digital output (isolated relay or 4–20 mA configurable) |
| Application Domain | Confined-space occupational health monitoring, tunneling (e.g., shield TBM construction), underground infrastructure safety management |
| Compliance Context | Designed for deployment in environments requiring adherence to OSHA 1910.120 (HAZWOPER), ISO 17025-accredited field measurement workflows, and GLP-aligned data integrity practices |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GAP TW |
| Price | Upon Request |
| Detection Gases | O₂ (0–30.0 %vol), Combustible Gas (CH₄, 0–100 %LEL) |
| Detection Principles | Electrochemical (O₂), Catalytic Bead (Combustible) |
| Sampling Method | Natural Diffusion |
| Measurement Accuracy | ±3% FS (O₂), ±5% FS (Combustible) |
| Display Resolution | 0.1 %vol (O₂), 1 %LEL (Combustible) |
| Alarm Thresholds (Configurable) | O₂ Low: 19.5 %vol, O₂ High: 23.5 %vol |
| Combustible | 25 %LEL |
| Response Time | ≤60 s (both gases) |
| Alarms | Visual (LED), Audible (≥75 dB @ 30 cm), Vibration, Voice Prompt |
| Power | ICR18500 Li-ion Battery, 3.7 V / 2000 mAh |
| Operating Time | ≥10 h (continuous) |
| Operating Temperature | −10 to +55 °C |
| Operating Humidity | 0–95 %RH (non-condensing) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GAP X2 P |
| Price | Upon Request |
| Detection Gases | Combustible Gas (EX), Hydrogen Sulfide (H₂S), Carbon Monoxide (CO), Oxygen (O₂) |
| Measurement Ranges | 0–100% LEL (EX), 0–100 ppm (H₂S), 0–1000 ppm (CO), 0–30% VOL (O₂) |
| Accuracy | ≤±5% FS (EX), ±10% (CO), ±5 µmol (H₂S) |
| Response Time | ≤45 s |
| Operating Temperature | −20 °C to +50 °C |
| Dimensions & Weight | 160 × 80 × 60 mm / 0.4 kg |
| Display | 3.5″ IPS, 320 × 480 resolution, bilingual (English/Chinese) |
| Power | 4600 mAh Li-ion battery, standby >9 h |
| Ingress Protection & Certification | IP66, Ex ib IIB T3 Gb |
| Alarm Modes | Audible (≥85 dB), visual (high-brightness LED), and vibration |
| Data Logging | 3000-event alarm memory |
| Sampling Method | Integrated micro-diaphragm pump (pump-suction) |
| Charging Interface | Micro-USB, compatible with portable power banks |
| Brand | PERIC |
|---|---|
| Model | GAP X4 |
| Gas Detection Channels | CH₄ (0–100% LEL), O₂ (0–30.0% vol), CO (0–500 ppm), H₂S (0–100 ppm) |
| Detection Principles | Catalytic combustion (CH₄), electrochemical (O₂, CO, H₂S) |
| Sampling Method | Diffusion |
| Response Time (T₉₀) | ≤60 s for all gases |
| Accuracy | ±5% FS (CH₄), ±3% FS (O₂), ±10% relative (CO, H₂S) |
| Display Resolution | 1% LEL / 0.1% vol / 1 ppm / 1 ppm |
| Alarm Thresholds (Configurable) | CH₄: 25% LEL |
| O₂ | Low 19.5% vol, High 23.5% vol |
| CO | 24 ppm |
| H₂S | 18 ppm |
| Power | Rechargeable 3.7 V Li-ion battery (103450 type) |
| Operating Temp | −10 °C to +55 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Ingress Protection | IP65 |
| Explosion Protection | Ex ib IIB T3 Gb per GB 3836.1–2010 & GB 3836.4–2010 |