PERIC
Filter
Showing 31–56 of 56 results
| Brand | PERIC |
|---|---|
| Model | GAP-D10 |
| Type | Portable Gas Analyzer |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measurand | NH₃ |
| Range | 0–100 ppm / 0–1000 ppm (switchable) |
| Detection Limit | <50 ppb (typical, 1σ, 1-s averaging) |
| Sampling Flow Rate | ≥2.8 L/min |
| Response Time (T₉₀) | ≤30 s |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 0–95 % RH (non-condensing) |
| Accuracy | ≤±1 % FS |
| Power Supply | 220 V AC, 50 Hz |
| Enclosure Rating | IP54 |
| Optical Path | Heated Multi-Pass Gas Cell |
| Signal Processing | Digital Lock-in Amplifier with 2f-WMS Demodulation |
| Brand | PERIC |
|---|---|
| Model | GAP-O3 |
| Measurement Principle | UV Absorption (254 nm) |
| Detection Range | 0–1000 nmol/mol |
| Detection Limit | ≤1 nmol/mol |
| Accuracy | ±3% FS |
| Repeatability | ≤1% |
| Response Time (T90) | ≤20 s |
| Zero Drift (4 h) | ±2 nmol/mol |
| Span Drift (4 h) | ±4 nmol/mol |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Display | 5-inch capacitive touchscreen |
| Power Supply | DC 12 V (with internal rechargeable Li-ion battery) |
| Compliance | Designed for continuous ambient and industrial process monitoring per ISO 13964, ASTM D5012, and EPA Reference Method EQOA-01 |
| Brand | PERIC |
|---|---|
| Model | GHB-X4 |
| Gas Detection Channels | O₂, CO, H₂S, Combustible Gas (CH₄-calibrated) |
| Measurement Principle | Electrochemical (CO, H₂S), Catalytic Bead (Combustible), Zirconia/Galvanic (O₂) |
| Power Supply | 3.7 V Li-ion (Detector: 5000 mAh |
| Magnetic Battery Pack | 27,000 mAh) |
| Intrinsic Safety Rating | Ex ib IIC T3 Gb per GB/T 3836.1–2021 & GB/T 3836.4–2021 |
| Operating Frequency Band | 410.15–493.125 MHz (default 430.125 MHz) |
| Max Transmit Power | 22.0 dBm |
| Receiver Sensitivity | −147 dBm (typ.) |
| LoRa Modem | SX1262-based |
| Network Topology | Self-organizing multi-hop mesh via repeaters |
| Default Upload Interval | 5 min |
| Standby Duration | ≥24 h (detector only), ≥7 days (with magnetic battery pack) |
| Charging Protocol Support | QC3.0 / FCP / SCP / VOOC / AFC (18 W fast charge) |
| Alarm Output | Dual-tone voice alert + dual-color LED flash + local buzzer |
| Environmental Rating | IP65 (detector unit) |
| Compliance | Meets GB/T 3836 series for intrinsic safety |
| Brand | PERIC |
|---|---|
| Model | GNF-TR-DP |
| Sensor Principle | Ultra-Thin Aluminum Oxide Capacitive |
| Measurement Range | –100 °C to +20 °C (Td) |
| Accuracy | ±2 °C @ +20 °C to –60 °C Td |
| Repeatability | ±0.5 °C |
| Stability | ±1% F.S. / 7 days |
| Response Time (63% / 90%) | 5 s / 10 s (–60 °C → –20 °C Td) |
| Explosion Protection | Ex db IIC T6 Gb (ATEX-compliant) |
| Ingress Protection | IP66 |
| Power Supply | 24 V DC |
| Communication Interface | TTL-level Serial Port |
| Analog Output | 4–20 mA (hardware-ready, software-configurable) |
| Mechanical Interface | M20×1.5 thread (display unit) |
| Operating Ambient Temperature | –10 °C to +50 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Sample Pressure | Atmospheric ±10% (vented to ambient) |
| Sample Flow Rate | 3–5 L/min |
| Sensor Lifetime | >2 years (normal operation) |
| Instrument Lifetime | >5 years (normal operation) |
| Brand | PERIC |
|---|---|
| Model | GNF-TR-H2 |
| Detection Principle | Thermal Conductivity (TCD) |
| Measurement Range | 0–5.00% H₂ (customizable) |
| Resolution | 0.01% H₂ |
| Accuracy | ≤±2% FS |
| Repeatability | ≤±1% FS |
| Zero Drift | ≤±2% FS/24h |
| Span Drift | ≤±2% FS/24h |
| Response Time (T90) | ≤30 s |
| Sample Pressure | ≤0.2 MPa |
| Sample Flow Rate | 500 ±10 mL/min |
| Sample Temperature | 0–50 °C |
| Ambient Operating Temperature | 0–50 °C |
| Storage Temperature | 0–50 °C |
| Relative Humidity | 20–80% RH (non-condensing) |
| Power Supply | DC 24 V |
| Power Consumption | <5 W |
| Output Signals | 4–20 mA DC (load ≤250 Ω) & RS485 Modbus RTU |
| Explosion Protection | Ex db IIC T6 Gb |
| Enclosure Rating | IP65 |
| Compensation | Integrated temperature & humidity compensation |
| Compliance | ATEX, IECEx, GB 3836.1/3836.4 compliant |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GNF-TR-O2 |
| Price | Upon Request |
| Measurement Principle | Fuel Cell Electrochemical Sensor |
| Measurement Range | 0–5.00% O₂ (customizable) |
| Resolution | 0.01% O₂ |
| Accuracy | ≤ ±1% FS |
| Repeatability | ≤ ±1% FS |
| Response Time (T90) | ≤ 30 s |
| Sample Pressure | ≤ 0.2 MPa |
| Sample Flow Rate | 500 ± 10 mL/min |
| Sample Temperature | 0–50 °C |
| Ambient Temperature | 0–50 °C |
| Storage Temperature | 0–50 °C |
| Relative Humidity | 20–80% RH (non-condensing) |
| Power Supply | 24 V DC ±10% |
| Power Consumption | < 1 W |
| Output Signal | 4–20 mA DC (load ≤ 250 Ω) or RS485 digital interface |
| Enclosure Material | Stainless Steel |
| Dimensions | 68 × 68 × 110 mm (L × W × H) |
| Process Connection | 1/4" NPT internal thread |
| Explosion Protection | Ex d II C T6 Gb |
| Temperature Compensation | Integrated |
| Compliance | ATEX Directive 2014/34/EU, IEC 60079-1, GB 3836.1 & GB 3836.2 |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | GNF-TR-O2-1 |
| Sensor Type | Electrochemical |
| Measurement Range | 0–10 / 0–100 / 0–1000 ppm O₂ |
| Accuracy | ±2% FS |
| Repeatability | ±1% FS |
| Response Time (T₉₀) | ≤30 s |
| Stability | ±1% FS / 7 days |
| Explosion Protection Rating | Ex db IIC T6 Gb (ATEX/IECEx equivalent) |
| Ingress Protection | IP66 |
| Output Signal | 4–20 mA (3-wire), RS485 Modbus RTU |
| Power Supply | 24 VDC |
| Operating Temperature | –10 to +50 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Sample Pressure | Ambient ±10% (outlet vented to atmosphere) |
| Sample Flow Rate | 1.0–1.5 L/min |
| Gas Inlet/Outlet | 1/4″ NPT female, with standard Φ6 stainless steel compression fittings |
| Sensor Lifetime | >2 years (typical operating conditions) |
| Instrument Service Life | >5 years (normal use) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GRS-Fxx |
| Pricing | Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GX-C100X |
| Pricing | Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Custom Software Solution |
| Pricing | Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | OX-01 |
| Pricing | Available Upon Request |
| Oxygen (O2) Detection Principle | Zirconia Electrochemical Cell |
| O2 Range | 90–100 % vol |
| O2 Resolution | 0.01 % |
| CO2 Detection Principle | NDIR (Non-Dispersive Infrared) |
| CO2 Range | 0–2000 ppm |
| CO2 Resolution | 0.1 ppm |
| CO Detection Principle | Electrochemical Sensor |
| CO Range | 0–50 ppm |
| CO Resolution | 0.1 ppm |
| Cl₂ Detection Principle | Electrochemical Sensor |
| Cl₂ Range | 0–10 ppm |
| Cl₂ Resolution | 0.1 ppm |
| Dew Point Temperature Measurement Principle | Capacitive Hygrometry |
| Dew Point Range | –60 to +20 °C |
| Dew Point Resolution | 0.01 °C |
| Particulate Matter (PM) Detection Principle | Laser Light Scattering |
| PM Range | 0–1 mg/m³ |
| PM Resolution | 0.001 mg/m³ |
| Display | 5.6-inch high-resolution TFT LCD |
| Data Logging | Internal storage with timestamped records |
| Portability | Handheld, battery-operated design for field deployment |
| Brand | PERIC |
|---|---|
| Model | PG-TR-H2 |
| Measurement Gas | Hydrogen (H₂) |
| Output Signals | 4–20 mA, RS485, 0–3 V DC |
| Power Supply | 12–24 V DC |
| Measurement Ranges | 0–2000 µmol/mol or 0–5000 µmol/mol (selectable) |
| Response Time | ≤60 s |
| Resolution | 1 µmol/mol |
| Accuracy | ±5% FS |
| Enclosure Rating | Explosion-Proof (certified per GB 12358-2006) |
| Construction | Full 316L Stainless Steel |
| Sampling Method | In-situ diffusion through process pipeline wall |
| Compliance | GB/T 3369.1-2008, GB/T 19582.2-2008 (Modbus RTU), GB 12358-2006, GB/T 11606-2007 |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | PG-TR-O2 |
| Price | Upon Request |
| Detection Principle | Ion Current |
| Measurement Range | 0–1000 μmol/mol (ppm) |
| Accuracy | ±5% FS |
| Resolution | 1 μmol/mol |
| Repeatability | ≤1.5% at 50% FS |
| Response Time (T90) | <20 s |
| Output Signals | 4–20 mA (2-wire), RS485 (Modbus RTU) |
| Power Supply | DC 24 V |
| Compliance | GB/T 3369.1-2008, GB/T 11606-2007, GB 12358-2006, GB/T 19582.2-2008, GB/T 2828.1, GB/T 700-2006, GB/T 191-2008 |
| Expected Service Life | ≥5 years (full unit, including sensor) |
| Sensor Storage Stability | No lifetime degradation when stored unpowered and exposed to ambient air |
| Brand | PERIC |
|---|---|
| Model | PR-CEMS-100 |
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Pricing | Available Upon Request |
| Measurement Principles | UV Differential Optical Absorption Spectroscopy (UV-DOAS), Non-Dispersive Infrared (NDIR), Electrochemical Sensing |
| Measured Gases | SO₂, NO, NO₂, CO, CO₂, O₂, CH₄ (optional) |
| Sample Flow Rate | 60–100 L/min |
| Response Time | ≤30 s |
| Accuracy | ≤±2% FS |
| Zero/ Span Drift | <±2% FS/week |
| S/C Ratio Calculation | Supported |
| Environmental Rating | Marine-grade (salt fog, vibration, acceleration/deceleration) |
| Compliance | MARPOL Annex VI, GB 15097–2016, GD01–2011 |
| Certifications | Recognized by Major Classification Societies (e.g., CCS, DNV, LR, ABS) |
| Output Interfaces | 4–20 mA analog, Modbus TCP/RTU |
| Optional Enclosure | Climate-controlled cabinet with HVAC |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Producer |
| Country of Origin | China |
| Model | PR-CH4-1000 |
| Measurement Range | 0–1000 ppm CH₄ (customizable) |
| Repeatability | ≤ ±1% FS |
| Flow Rate | 1 L/min ±10% |
| Accuracy | ≤ ±1% FS |
| Stability | ≤ ±1% FS/week |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | PR-GDS-100 |
| Pricing | Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PR-GLRSA |
| Quotation | Upon Request |
| Detection Channels | 2 (simultaneous) |
| Target Gases | H₂, CO, C₃H₈, C₃H₆ |
| Concentration Ranges | H₂: 0–50% vol, CO: 0–10% vol, C₃H₈: 0–50% vol, C₃H₆: 0–80% vol |
| Accuracy | ≤ ±3% FS |
| Response Time | ≤ 30 s |
| Explosion Protection | Ex db ec ib pzc II C T3 Gc (Positive-Pressure Purged & Pressurized) |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V / 50 Hz, ≤ 800 W (host only) |
| Purge Gas | Clean, oil-free, dry, particle-free compressed air, 0.4–0.8 MPa |
| Brand | PERIC |
|---|---|
| Model | PR-LM |
| Type | Portable / Handheld Raman Spectrometer |
| Origin | Hebei, China |
| Manufacturer | PERIC Instrument Co., Ltd. |
| Measurement Range | 0–100% (v/v) |
| Detection Limit | 1 µmol/mol |
| Accuracy | ±0.1% (full scale) |
| Analysis Time | 1–300 s (user-configurable) |
| Sample Inlet | Integrated diaphragm pump |
| Dimensions (L×W×H) | 557 × 420 × 330 mm |
| Weight | <23 kg |
| Target Gases | H₂, N₂, O₂, CO, CO₂, CH₄, NH₃, H₂O, H₂S, C₂H₂, C₂H₄, C₂H₆, C₃H₆, and other hydrocarbons and inorganic gases |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Region | Domestic (China) |
| Model | PR-LR |
| Pricing | Upon Request |
| Gas Detection Range | N₂, O₂, H₂, CH₄, CO, CO₂, C₂H₆, C₂H₄, C₂H₂, C₃H₈, C₃H₆, C₄H₁₀, NO, NO₂, SO₂, H₂S |
| Accuracy | ≤±1% FS for components >1% full scale |
| Resolution | ≤0.01% (for >1% FS) |
| Analysis Time | 10–30 s (adjustable) |
| Laser Wavelength | 532 nm |
| Laser Linewidth | ≤0.1 nm |
| Spectral Range | 0–4200 cm⁻¹ |
| Spectral Resolution | 5 cm⁻¹ |
| Power Supply | 220 VAC, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Operating Temperature | 10–35 °C |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | PR-MeOH-1000 |
| Price | Upon Request |
| Measurand | Methanol (0–1000 ppm), Formaldehyde (0–1000 ppm) |
| Response Time | ≤30 s (each) |
| Accuracy | ±5% FS (each) |
| Measurement Principle | UV-DOAS (Formaldehyde, hot/wet sampling), NDIR (Methanol, chilled/dry sampling) |
| Operating Temperature | −10 to 50 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | PR-NH3-1000 |
| Pricing | Upon Request |
| Measured Gases | NH₃, NO, NO₂, N₂O |
| NH₃ Range | 0–2000 ppm |
| NO/NO₂ Range | 0–2000 ppm / 0–200 ppm |
| N₂O Range | 0–2000 ppm |
| Response Time | ≤30 s |
| Accuracy | ≤±5% FS |
| Measurement Principles | UV-DOAS (for NH₃, NO, NO₂), NDIR (for N₂O), Hot-Wet & Cold-Dry Sample Conditioning |
| Operating Temperature | −10 to 50 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PR-RM |
| Instrument Type | Online Raman Spectrometer |
| Gas Species | Benzene, Nitrogen, Hydrogen, Carbon Dioxide, Carbon Monoxide, Carbonyl Sulfide, Hydrogen Sulfide, Oxygen, Methane |
| Range | 0–100 %vol |
| Detection Limit | ≤50–100 ppm (gas-dependent) |
| Accuracy | ≤2 %FS |
| Measurement Cycle | 1–30 s (adjustable) |
| Sampling Method | Pump-aspirated with integrated pre-treatment |
| Environmental Robustness | Rated for high-pressure, high-temperature, high-humidity, high-dust, and hazardous-area operation |
| Maintenance | Consumable-free design |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RGA100 / RGA200 |
| Principle | Electron Ionization (EI) Quadrupole Mass Spectrometry |
| Mass Range | 0–200 amu |
| Minimum Sampling Interval | 0.05 amu |
| Mass Resolution (FWHM) | < 0.5 amu |
| Ion Source | EI Source with Yttria-Coated Iridium Filament (Filament Current: 0–4 A) |
| Detector | Electron Multiplier (Gain > 10³) |
| Scan Speed | 5–1000 ms per data point |
| Compliance | Designed for UHV and HV vacuum environments |
| Brand | PERIC |
|---|---|
| Model | SLAS-01 |
| Measurement Principle | TDLAS |
| Detectable Gases | O₂, CO, CO₂, CH₄, C₂H₂, H₂S, NH₃, HCl, HF |
| Detection Limits | O₂: 0.01% vol |
| CO | 1 µmol/mol |
| CO₂ | 0.01% vol |
| CH₄ | 0.01% vol |
| C₂H₂ | 0.01% vol |
| H₂S | 1 µmol/mol |
| Full-Scale Ranges | O₂/CO/CO₂/CH₄: 0–99.99% vol |
| C₂H₂/H₂S | 0–10% vol |
| Linearity Error | ≤ ±1% FS |
| Repeatability & Drift | ≤ ±1% FS per 6 months |
| Optical Path Length | ≤20 m |
| Sample Temperature | ≤800 °C |
| Sample Pressure | ±5 kPa |
| Ambient Temperature | −20 to +60 °C |
| Ambient Humidity | ≤90% RH |
| Power Supply | DC 24 V |
| Relay Outputs | 3 × (24 V / 1 A) |
| Analog Outputs | 2 × 4–20 mA (max. load 750 Ω) |
| Digital Interface | RS485, Modbus RTU protocol |
| Display | Magnet-controlled graphical interface |
| Enclosure Rating | IP66 |
| Explosion Protection | Ex d IIC T6 |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Custom-Built |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YWT-2024 |
| Pricing | Upon Request |
| Detection Principle | Light Scattering (Multi-Path Compensated) |
| Portability | Portable |
| Application Scope | Marine Engineering, Hydraulic Systems, Engine Rooms, and Industrial Enclosures |
| Target Aerosol Size Range | 1–10 µm |
| Measurement Range | 0–5 mg/L |
| Resolution | 0.01 mg/L |
| Output Interface | RS485 |
| Power Supply | 24 VDC |
| Ingress Protection Rating | IP56 |
| Operating Temperature | 0–70 °C |
| Compliance | IACS Unified Requirement UR67 (Oil Mist Detection in Main Engine Crankcases) |