Qingji
Filter
Showing 61–90 of 93 results
| Brand | Qingji |
|---|---|
| Model | QJ210 |
| Type | Electronic Universal Testing Machine |
| Max Load Capacity | 2500 N |
| Load Accuracy | Class 0.5 |
| Effective Test Width | 150 mm |
| Effective Stroke | 300 mm |
| Test Speed Range | 0.01–1000 mm/min |
| Speed Accuracy | ±0.5% of reading |
| Displacement Measurement Accuracy | ±0.5% of reading |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Motor Power | 200 W |
| Dimensions (L×W×H) | 430 × 315 × 855 mm |
| Weight | 40 kg |
| Compliance | GB, ISO, ASTM, JIS |
| Brand | Qingji |
|---|---|
| Model | QJ-210 |
| Type | Electromechanical Universal Testing Machine |
| Load Capacity | 0–2.5 kN |
| Load Accuracy | ±0.5% |
| Speed Range | 0.001–300 mm/min |
| Speed Accuracy | ±0.5% |
| Stroke Accuracy | ±0.5% |
| Displacement Accuracy | ±0.5% |
| Effective Width | 150 mm |
| Max Stroke | 300 mm (extendable) |
| Safety Features | Electronic travel limit protection, emergency stop button |
| Unit Weight | ~45 kg |
| Brand | Qingji |
|---|---|
| Model | QJ210-2KN |
| Max Test Force | 2500 N |
| Force Range | 0–2500 N |
| Force Accuracy | ±0.5% FS |
| Stroke | 300 mm |
| Displacement Resolution | 0.001 mm |
| Test Speed | 0.001–300 mm/min |
| Speed Accuracy | ±0.5% |
| Stroke Accuracy | ±0.5% |
| Displacement Accuracy | ±0.5% |
| Effective Width | 150 mm |
| Safety Features | Electronic Limit Protection, Emergency Stop |
| Unit Weight | ~45 kg |
| Brand | Qingji |
|---|---|
| Model | QJ-210A |
| Type | Electromechanical Universal Tensile Tester |
| Max Load Capacity | 5 kN |
| Load Range | 0–5 kN (Full-Scale) |
| Load Accuracy | ±0.5% FS |
| Stroke | 800 mm |
| Displacement Resolution | ±0.5% FS |
| Test Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% |
| Effective Width | 150 mm |
| Safety Features | Electronic Limit Switches, Emergency Stop Button |
| Weight | ~45 kg |
| Origin | Shanghai, China |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210A |
| Max Test Load | 5 kN |
| Force Range | up to 5000 N |
| Force Accuracy | ±0.5% of reading |
| Travel Distance | 800 mm |
| Displacement Resolution | 0.001 mm |
| Effective Test Width | 150 mm |
| Speed Range | 0.01–500 mm/min |
| Speed Accuracy | ±0.5% of set value |
| Displacement & Deformation Accuracy | ±0.5% of reading |
| Load Cell | High-precision U.S.-sourced sensor |
| Controller | Panasonic full-digital AC servo system |
| Protection | Software diagnostics, electronic limit switches, overload protection (10% above capacity) |
| Power Supply | 200 V, 400 W |
| Dimensions (L×W×H) | 590 × 355 × 1640 mm |
| Weight | ~85 kg |
| Compliance | GB, ISO, ASTM, JIS, DIN, YB, YY, QC, HG, and other international & industry standards |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJ210F |
| Price | USD 9,450 (FOB Shanghai) |
| Test Speed | 0–500 mm/min |
| Max Test Height | 150 mm |
| Displacement Measurement Accuracy | ±1% of reading |
| Minimum Micrometer Adjustment | 0.01 mm |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210K Sponge-Specific |
| Max Test Force | 2 kN |
| Load Rate Range | 0.01–300 mm/min |
| Platen Spacing | 500 mm |
| Platen Dimensions | 300 mm × 300 mm |
| Compliance | GB/T 10807–2006, GB/T 6344–1996, GB/T 20467–2006 |
| Force Sensor Accuracy | ±0.01% FS |
| Force Measurement Class | 0.5 |
| Repeatability | ≤0.5% |
| Displacement Accuracy | ≤0.2% |
| Deformation Accuracy | ≤0.2% |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJ210V |
| Price Range | USD 7,000 – 28,000 |
| Instrument Type | Electromagnetic Fatigue Testing Machine |
| Maximum Test Force | 500 N |
| Frequency Range | 61–2604 Hz |
| Host Weight | 50 kg |
| Load Accuracy Class | 0.5 |
| Voltage Measurement Range | 0–80 V (±1% FS) |
| Current Measurement Range | 0–2600 mA (±1% FS) |
| Response Time Resolution | 0.1 ms |
| Data Sampling Rate | 20 kHz |
| Hysteresis Loop Sampling Rate | 1000 Hz |
| Proportional Power Supply | Output Current 500–2600 mA (programmable), PWM Frequency 61–2604 Hz, Dither Frequency 60–400 Hz |
| Programmable DC Power Supply | 0–32 V / 6 A |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211 |
| Maximum Load Capacity | 30 kN |
| Load Cell Accuracy | 0.01% |
| Measurement Accuracy | < ±0.5% |
| Control System | Windows-based PC control with real-time digital display |
| Effective Test Width | ~420 mm |
| Effective Stroke | ~800 mm |
| Test Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% |
| Displacement Accuracy | ±0.5% |
| Deformation Measurement Accuracy | ±0.5% |
| Safety Features | Electronic stroke limit protection, emergency stop button |
| Unit Weight | ~140 kg |
| Brand | Qingji |
|---|---|
| Model | QJ211 |
| Type | Electromechanical Universal Testing Machine |
| Maximum Load Capacity | 30 kN |
| Load Accuracy | ±0.5% of reading |
| Effective Test Width | 420 mm |
| Effective Test Height (without fixtures) | 800 mm |
| Crosshead Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% of set value |
| Displacement Measurement Accuracy | ±0.5% of reading |
| Strain/Deformation Measurement Accuracy | ±0.5% of reading |
| Force Resolution | 300,000 counts (full-scale, single-range, no auto-ranging) |
| Overload Protection | Activates at >110% of full scale |
| Motor Power | 750 W |
| Dimensions (W×D×H) | 700 × 420 × 1600 mm |
| Weight | 145 kg |
| Compliance | ISO 7500-1, ASTM E4, ASTM E8/E21, GB/T 228.1 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211D |
| Maximum Test Force | 0–500 kN |
| Frequency Range | 0.001–1000 Hz |
| Actuator Stroke | ±200 mm (customizable) |
| Force Measurement Accuracy | ±1% of reading (2–100% FS) |
| Dynamic Force Ripple | ≤2% |
| Displacement Measurement Accuracy | ±0.5% of full scale |
| Closed-Loop Control Bandwidth | 10 kHz |
| Waveform Options | Sine, Square, Triangle, Trapezoidal, Sawtooth, Half-Sine, Half-Triangle, Random, User-Defined, and External Input |
| Control Modes | Force, Displacement, and Strain (seamless mode switching) |
| Host Weight | 150–850 kg |
| Brand | Qingji |
|---|---|
| Model | QJ211S |
| Max Load Capacity | 10 kN |
| Accuracy Class | 0.5 |
| Effective Test Width | 320 mm |
| Stroke (Tensile Space) | 500 / 800 mm |
| Speed Range | 0.01–300 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Force Measurement Range | 0.02–100% of full scale |
| Displacement & Strain Accuracy | ±0.5% of indicated value |
| Load Cell | High-precision sensor (USA-made) |
| Controller | Panasonic全数字交流伺服控制系统 |
| Control Mode | Full-digital closed-loop control (constant stress/strain/displacement) |
| Safety Protection | Software diagnosis, electronic limit switches, overload protection at 110% FS |
| Weight | ~145 kg |
| Power | 2–5 kW |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211S |
| Maximum Load Capacity | 30 kN |
| Load Measurement Range | 0–30 kN |
| Load Accuracy | ±0.5% of reading |
| Crosshead Travel | 800 mm (excluding fixtures) |
| Displacement Resolution | 0.001 mm |
| Effective Test Width | 420 mm |
| Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% of set value |
| Displacement Accuracy | ±0.5% of reading |
| Deformation Measurement Accuracy | ±0.5% of reading |
| Power Supply | 750 W |
| Dimensions (W×D×H) | 700 × 420 × 1600 mm |
| Weight | 145 kg |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QJ211S-5KN |
| Load Capacity | 5 kN |
| Load Accuracy | ±0.5% FS |
| Effective Test Width | 400 mm |
| Effective Stroke | 500 mm |
| Test Speed Range | 0.01–500 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement Resolution | 0.025 µm |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Position Measurement Accuracy | ±0.5% of reading |
| Deformation Measurement Accuracy | ±0.5% of reading |
| Overload Protection | Activates at >110% of rated load |
| Motor | 400 W, 220 V AC |
| Dimensions (L×W×H) | 500 × 450 × 1650 mm |
| Weight | 165 kg |
| Brand | Qingji |
|---|---|
| Model | QJ-211S2 |
| Type | Electromechanical Universal Testing Machine |
| Load Capacity | 0.01 N to 30 kN |
| Load Accuracy | ±0.5% of reading |
| Effective Test Width | 420 mm |
| Effective Test Height (excluding fixtures) | 800 mm |
| Crosshead Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% of set value |
| Displacement Measurement Accuracy | ±0.5% of reading |
| Strain/Deformation Measurement Accuracy | ±0.5% of reading |
| Resolution | 300,000 counts full-scale, no internal range switching |
| Power | 750 W |
| Dimensions (W×D×H) | 700 × 420 × 1600 mm |
| Weight | 145 kg |
| Compliance | Meets ISO 7500-1 Class 0.5, ASTM E4, ASTM E8/E21, GB/T 228.1–2021 |
| Brand | Qingji |
|---|---|
| Model | QJ-212 |
| Type | Electromechanical Universal Testing Machine |
| Load Capacity | 0.02–500 kN |
| Load Accuracy | ±0.5% |
| Effective Test Width | 500 mm |
| Effective Tensile Stroke | 600 mm or 800 mm |
| Test Speed Range | 0.001–1000 mm/min |
| Speed Accuracy | ±0.5% of reading |
| Displacement Measurement Accuracy | ±0.5% of reading |
| Strain/Deformation Measurement Accuracy | ±0.5% of reading |
| Force Resolution | 1/250,000 (full-scale, no range switching) |
| Machine Dimensions (W×D×H) | 1000 × 680 × 2450 mm |
| Machine Weight | 1250 kg |
| Safety Features | Electronic limit protection, overload protection (10% above rated load), manual/auto return, stepless speed control for crosshead movement |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ212-300KN |
| Load Capacity | 0–300 kN |
| Load Accuracy | ±0.5% of full scale |
| Effective Test Width | 520 mm |
| Max Tensile Stroke | 800 mm |
| Test Speed Range | 0.01–1000 mm/min (standard: 300 mm/min) |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement Measurement Accuracy | ±0.5% of indicated value |
| Strain Measurement Accuracy | ±0.5% of indicated value |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Control System | Panasonic全-digital AC servo controller |
| Load Cell | High-precision sensor (USA-sourced) |
| Software | Windows-based closed-loop test control system supporting ISO, ASTM, JIS, DIN standards |
| Safety Protection | Electronic limit switches, software-based overload diagnosis, auto-return function, 10% over-load cutoff |
| Power Requirement | 2–5 kW |
| Dimensions (W×D×H) | 1000 × 680 × 2450 mm |
| Weight | ~1450 kg |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ212-50 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Maximum Test Load | 100 kN |
| Adjustable Load Range | Up to 50 kN (user-selectable) |
| Load Accuracy | ±0.5% of full scale |
| Crosshead Travel | 800 mm |
| Displacement Resolution | ±0.5% of reading |
| Load Cell | High-precision U.S.-sourced transducer |
| Control System | Panasonic all-digital AC servo controller |
| Control Mode | Full-closed-loop digital control enabling constant stress, constant strain, and constant displacement testing |
| Effective Test Width | 520 mm |
| Test Speed Range | 0.01–1000 mm/min (standard speed: 300 mm/min) |
| Speed Accuracy | ±0.5% of set value |
| Displacement Measurement Accuracy | ±0.5% of reading |
| Strain Measurement Accuracy | ±0.5% of reading |
| Safety Protection | Software-based fault diagnosis, electronic limit switches, overload protection at 110% of rated load |
| Fixture Customization | Available per specimen geometry and standard requirements |
| Power Supply | 2–5 kW |
| Dimensions (W×D×H) | 1000 × 680 × 2450 mm |
| Weight | ~1450 kg |
| Compliance | ISO 6892-1, ASTM E8/E21, JIS Z2241, DIN 50125 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ212C |
| Load Capacity | 0–500 kN (selectable) |
| Load Accuracy | ±0.5% of full scale |
| Force Resolution | ±1/250,000 FS (constant across full range) |
| Effective Test Width | 500 mm |
| Max. Tensile Travel | 600 mm or 800 mm (configurable) |
| Test Speed Range | 0.001–1000 mm/min |
| Speed Accuracy | ±1% of indicated value |
| Displacement Measurement Accuracy | ±0.5% of indicated value |
| Strain/Deformation Measurement Accuracy | ±0.5% of indicated value |
| Motor Power | 1.5 kW |
| Dimensions (W×D×H) | 960 × 650 × 2000 mm |
| Weight | 1200 kg |
| Safety Features | Electronic travel limit protection, overload protection at 110% FS, manual/auto return, dual-speed crosshead control |
| Compliance Standards | ISO 6892-1, ASTM E8/E21, JIS Z2241, DIN 50125 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ212C |
| Load Capacity | 50 kN / 100 kN / 200 kN / 300 kN / 500 kN (interchangeable within 500 kN) |
| Load Accuracy | ±0.5% |
| Effective Test Width | 520 mm |
| Max Tensile Travel | 800 mm |
| Speed Range | 0.01–1000 mm/min (standard configuration: 300 mm/min) |
| Speed Accuracy | ±0.5% of reading |
| Displacement Measurement Accuracy | ±0.5% of reading |
| Strain Measurement Accuracy | ±0.5% of reading |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Control System | Panasonic全-digital AC servo controller |
| Sensor Origin | USA |
| Software Architecture | Full-digital closed-loop control supporting constant stress, constant strain, and constant displacement modes |
| Safety Features | Electronic limit switches, software-based overload diagnosis, auto-return function, 110% over-load protection |
| Power | 2–5 kW |
| Dimensions (W×D×H) | 1000 × 680 × 2450 mm |
| Weight | ~1450 kg |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ215 |
| Max Load Capacity | 50–500 kN (configurable) |
| Maximum Test Pipe Diameter | ≤ Φ5000 mm |
| Accuracy Class | Class 1 / Class 0.5 |
| Test Speed Range | 0.01–1000 mm/min (standard speed: 300 mm/min) |
| Load Accuracy | ±1% (±0.5%) of reading |
| Speed Accuracy | ±0.5% (±0.15%) of reading |
| Displacement Resolution | 0.01 mm |
| Control Interface | Full Chinese GUI with PC-integrated real-time curve display, data auto-storage, and report printing capability |
| Structural Configuration | Four-column or six-column universal testing frame |
| Compliance | Designed to meet ISO 9969, ASTM D2412, EN 1446, GB/T 9647, and GB/T 18477 test standards for ring stiffness evaluation |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCK |
| Temperature Range | -70 °C to +350 °C (steady-state at 350 °C) |
| Ramp Rate | ≥5 °C/min |
| Temperature Resolution | 0.1 °C |
| Load Capacity | up to 30 kN |
| Load Cell Accuracy | ±0.01% FS |
| Force Measurement Uncertainty | <±1% or <±0.5% |
| Displacement Accuracy | ±0.5% |
| Strain/Deformation Accuracy | ±0.5% |
| Speed Range | 0.001–500 mm/min (extendable to 1000 mm/min) |
| Speed Accuracy | ±0.5% |
| Effective Width | 420 mm |
| Effective Stroke | ~800 mm (height-adjustable) |
| Safety Features | Electronic travel limit switches, emergency stop circuit |
| Net Weight | 135 kg |
| Brand | Qingji |
|---|---|
| Model | QJCLR8731 |
| Temperature Range (High Zone) | 60–200 °C |
| Temperature Range (Low Zone) | –10 to –65 °C (standard), optional –75 °C |
| Test Chamber Operating Range | –10 to –60 °C |
| Temperature Stability | ±1 °C |
| Temperature Uniformity | ±2 °C |
| Recovery Time | ≤5 min |
| Heating Rate (Typical) | 40 min (from –40 °C to +150 °C) |
| Cooling Rate (Typical) | 60–90 min (from +150 °C to –40 °C) |
| Controller | 7.5″ color LCD touchscreen with bilingual (English/Chinese) interface, 256-color display, adjustable backlight, direct-key operation |
| Safety Protections | Fuseless circuit breaker, compressor high-pressure/overheat/overcurrent protection, chamber overtemperature cutoff, fan overload protection |
| Standard Accessories | Two sample racks, one 50 mm diameter cable port |
| Compliance | GB/T 2423.1–2021, GB/T 2423.2–2001, GJB 150.5A–2009, GB 10592–2008 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJHT |
| Pricing | Available Upon Request |
| Power Supply | 220 V, 50 Hz |
| Time Resolution | 0.0001 s |
| Resilience Coefficient Range | 25–80 % |
| Measurement Accuracy | < ±1 % |
| Sample Dimensions | 100 mm × 100 mm × (50 ± 2) mm |
| Conditioning | 23 ± 2 °C, 45–50 % RH, ≥16 h prior to test |
| Standard Compliance | GB/T 6670–1986 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJIC |
| Voltage | AC 220 V ±5% |
| Power Consumption | 35 W |
| Bending Speed | 29 rpm |
| Test Cycles | 1–999 cycles |
| Angular Displacement (Torsion) | 15° ±1°, bidirectional |
| Dimensions (L×W×H) | 670 × 380 × 220 mm |
| Weight | 70 kg |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJNZ |
| Max Torque Capacity | 0–10,000 N·m |
| Torque Measurement Accuracy | ±0.5% |
| Torque Resolution | 1/350,000 (full-scale, no range switching) |
| Angular Displacement Range | 0 to ±100,000° |
| Angular Measurement Accuracy | ±0.5% |
| Angular Resolution | ±0.001° |
| Angular Precision | 0.009° |
| Torsion Speed Range | 0.01–1,000 °/min (infinitely variable) |
| Speed Accuracy | ±0.2% of indicated value |
| Gauge Length Adjustment | up to 1,500 mm |
| Specimen Clamping Diameter | Φ8–Φ40 mm (expandable) |
| Dimensions (L×W×H) | 2800 × 4700 × 1250 mm |
| Weight | 1,500 kg |
| Compliance | GB/T 9370–1999, GB/T 239–1999, JJG 269–1981 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJNZ-10000 |
| Max Torque | 10000 N·m |
| Torque Measurement Range | 1–10000 N·m |
| Torque Resolution | ±0.001° |
| Torsional Angle Measurement Range | 0 to ±100000° (4-digit display) |
| Angular Resolution | ±0.001° |
| Angular Accuracy | ±0.009° |
| Torsion Speed Range | 0.01–1000 °/min (infinitely variable) |
| Speed Accuracy | ±0.2% of indicated value |
| Torque Measurement Error | ±0.5% |
| Torque Resolution (Full Scale) | 1/350000 (no range switching, constant resolution) |
| Gauge Length | 1500 mm |
| Specimen Clamping Diameter | Φ8–Φ40 mm (extendable) |
| Dimensions (L×W×H) | 2800 × 4700 × 1250 mm |
| Weight | 1500 kg |
| Motor Power | 5 kW |
| Compliance | GB/T 9370–1999, GB/T 239–1999, JJG 269–1981 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJPL-10KN |
| Maximum Test Force | 10 kN |
| Frequency Range | 0.001–100 Hz |
| Actuator Stroke | 50 mm (adjustable) |
| Effective Test Width | 60 mm |
| Max Spring Outer Diameter | ≤60 mm |
| Max Free Length | ≤240 mm |
| Amplitude Range | 0.001–50 mm |
| Load Accuracy Class | 0.5 |
| Load Measurement Range | 0.2–100% of full scale |
| Load Resolution | 1/30,000 (dynamic, 10 kHz sampling) |
| Displacement Measurement Accuracy | ±0.002 mm |
| Deformation Measurement Accuracy | ±1% of reading |
| Safety Features | Overload protection (10% above capacity), mechanical limit switches, programmable return-to-start |
| Power Supply | 220 V AC, 2 kW |
| Host Weight | ≈850 kg |
| Software | Dedicated fatigue test control & data acquisition suite with audit trail capability |
| Compliance | Designed to support ISO 527, ISO 10215, ASTM E466, and GB/T 2611 test protocols |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJWE543L |
| Maximum Test Load | 200 kN |
| Frequency Range | 0.01–1000 Hz |
| Actuator Stroke | ±200 mm (customizable) |
| Load Accuracy | ±1% (2–100% FS) |
| Dynamic Load Ripple | ≤2% |
| Displacement Accuracy | ±0.5% |
| Closed-Loop Control Bandwidth | 10 kHz |
| Waveform Options | Sine, Square, Triangle, Trapezoidal, Sawtooth, Half-Sine, Half-Triangle, Random, User-Defined, and External Input |
| Control Modes | Force, Displacement, and Strain (smooth mode switching) |
| Machine Weight | 850 kg |
| Brand | Qingji |
|---|---|
| Model | QJWK-507 |
| Temperature Range | Ambient to 300 °C |
| Heating Rate Options | (12 ± 1) °C/6 min or (5 ± 0.5) °C/6 min |
| Temperature Accuracy | ±1 °C |
| Deformation Measurement Range | 0–1 mm |
| Deformation Resolution | 0.01 mm |
| Heating Medium | Methyl Silicone Oil |
| Heating Power | 4 kW |
| Cooling Method | Natural cooling above 150 °C |
| Power Supply | AC 220 V, 20 A, 50 Hz |
| Dimensions (L×W×H) | 540 × 520 × 1360 mm |
| Compliance | GB/T 1633, GB/T 1634, GB 8802, ISO 75, ISO 306, ISO 2507 |