Gas Detector
Filter
Showing 1441–1470 of 3002 results
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | iTrans iTrans |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iTX |
| Pricing | Available Upon Request |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109A |
| Detection Principle | Dual Flame Ionization Detection (FID) |
| Operating Temperature | 190 °C (heated sample path, detector chambers, and filter) |
| Filter Material | Stainless Steel |
| Filter Pore Size | 2 µm |
| Filtration Mode | Compressed Air or Nitrogen Back-Pulse Cleaning |
| Sample Inlet Configuration | Integrated Heated Sample Line with Adjustable Backplate Condensation Prevention System |
| Compliance | EN 14181, EN ISO 14956, EN 12619, EN 13526, EPA Method 25A, US EPA Reference Method 503 |
| Application Scope | Continuous Emission Monitoring (CEM), Stack Gas Analysis, Ambient Air NMHC Quantification, High-Purity Gas Purity Verification |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109A-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Emission Monitoring (CEM) Analyzer |
| Typical Configuration | Total Volatile Organic Compounds (TVOC) Analyzer |
| Measurement Range | 0–100,000 ppm (as propane or methane equivalent) |
| Resolution | 100 ppb |
| Accuracy | ±5% of reading |
| Response Time (T90) | <1 s |
| Operating Temperature of Sample Path & Detectors | 190 °C |
| Filter Material | Stainless Steel |
| Filter Pore Size | 2 µm |
| Purge Gas | Compressed Air or Nitrogen |
| Integrated Combustion Air Supply | Yes |
| Sample Pump | Integrated |
| Zero/Calibration Gas Management | Overload Protection with Automatic Calibration Sequence |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109A-OVE |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Configuration | Total VOC (TVOC) Monitoring System |
| Measurement Range | 0–1000 ppm (as propane equivalent) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109L |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Configuration | Total VOC / THC / NMHC / CH₄ Analyzer |
| Measurement Range | 0–1000 ppm (selectable up to 100,000 ppm) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Heating Chamber Temperature | 190 °C |
| Detector Sensitivity | ≤1 ppm full-scale for CH₄ |
| Carrier/Air Supply | Integrated zero-air generator |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 155-15 |
| Sample Flow Range | 10–30 mL/min |
| Operating Temperature | 180 °C (heated sample path) |
| Detector Type | Flame Ionization Detector (FID) |
| Compliance | Designed for ASTM D5114, ISO 8712, and EPA Method 25A-compliant SHED testing |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure | 19″ rack-mountable (5 U) or top-mount configuration |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 155-15FID |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Detection Range | 0–10,000 ppm C₁–C₁₀ (as methane equivalent) |
| Resolution | 0.1 ppm |
| Accuracy | ±0.1 ppm (at low end), ±1% FS (full scale) |
| Response Time (T₉₀) | ≤3 s at 15 mL/min sample flow |
| Sample Flow Rate | Adjustable 10–30 mL/min (600–1,800 L/h) |
| Heating Zone Temperature | 180 °C (uniform, thermostatically controlled) |
| Integrated Combustion Air Supply | Yes (built-in compressor, no external air source required) |
| Brand | CHINYEE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3-200-3 |
| Instrument Type | Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-200 |
| Detection Principle | Flame Ionization Detection (FID) |
| Operating Temperature | 190 °C (heated sample path & detector chamber) |
| Response Time | < 1 s |
| Fuel | Hydrogen (low-pressure metal-hydride cartridge, 40 h runtime) |
| Combustion Air | Integrated air generator (no external cylinder required) |
| Sample Filtration | 2 µm stainless steel filter (permanent or replaceable) |
| Filter Cleaning | Automated compressed air or nitrogen back-purge (measurement uninterrupted) |
| Compliance | EPA Method 25A, EN 12619, ISO 8573-1 (gas purity), GLP/GMP-ready data handling |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-200 |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 to 0–100,000 ppm (selectable full-scale ranges) |
| Sensitivity | ≤1 ppm CH₄ full-scale |
| Response Time (T₉₀) | ≤0.2 s |
| Oven Temperature | 190 °C |
| Carrier/Air Supply | Integrated zero-air generator |
| Compliance | EN 12619, EN 13526, EPA Method 25A, EPA Method 503, 2nd/13th/17th BImSchV |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-200-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Portable Online Analyzer |
| Detection Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Operating Heater Temperature | 190 °C |
| Sensitivity (CH₄) | ≤1 ppm full-scale |
| Carrier/Combustion Air | Integrated zero-air generator |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-200-a |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Portable Online Analyzer |
| Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Detector Temperature | 190 °C |
| Carrier/Air Supply | Integrated zero-air generator |
| Sensitivity (CH₄) | 1 ppm full-scale |
| Flow Stability | Precision back-pressure regulation |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-300A |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Detection Range | 0–1000 ppm (expandable to 100,000 ppm) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Operating Heater Temperature | 190 °C |
| Carrier/Combustion Air | Integrated compressed air supply |
| Filter Design | Pneumatically actuated reverse-pulse backflush system |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Instrument Type | Online Analyzer |
| Detection Principle | Flame Ionization Detection (FID) |
| Detection Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Typical Configuration | Total VOC (TVOC) Monitoring System |
| Heating Chamber Temperature | 190 °C |
| Detector Sensitivity | ≤1 ppm (CH₄ full scale) |
| Combustion Air Supply | Integrated, self-contained |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-600 |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | ppm-level total hydrocarbons (THC), non-methane hydrocarbons (NMHC), and ethane-adjusted NMHC |
| Operating Temperature | Heated FID chamber (typically 180–220 °C) |
| Sample Flow Stability | Precision back-pressure regulator integrated |
| Combustion Air Supply | Internal zero-air generator |
| Compliance | Designed for continuous emission monitoring (CEM) in industrial and environmental applications |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-600-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Configuration | Total VOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Sensitivity | ≤1 ppm (CH₄ full scale) |
| Heater Chamber Temperature | 190 °C |
| Carrier/Air Supply | Integrated zero-air generator |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-900-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Portable Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Heating Chamber Temperature | 190 °C |
| Sensitivity (CH₄) | Up to 1 ppm full scale |
| Burner Air Supply | Integrated compressed air generator |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 5-100 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Detector Sensitivity | 1 ppm full-scale for CH₄ |
| Oven Temperature | 190 °C |
| Carrier/Combustion Air | Integrated air supply |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | OVF3000 |
| Detection Principle | Flame Ionization Detection (FID) |
| Operating Temperature | 180 °C (heated sample path & detector) |
| Fuel System | Low-pressure solid-state metal hydride hydrogen storage |
| Fuel Runtime | 40–50 h continuous operation |
| Max Fill Pressure | 30 bar (430 PSI) |
| Response Time | ≤ 0.2 s |
| Sample Filter | Front-panel accessible, tool-free heated filter |
| Combustion Air | Integrated zero-air generator |
| Safety Features | Flame-out detection with automatic gas shutoff |
| Compliance | Designed for EPA Method 25A, ASTM D6348, ISO 8573-5, and EU EN 15267-3 applicable environments |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | OVF3000 |
| Detection Principle | Flame Ionization Detection (FID) |
| Sensitivity | 1 ppm full-scale for CH₄ |
| Response Time | 0.2 s |
| Measurement Ranges | 0–10, 0–100, 0–1,000, 0–10,000, 0–100,000 ppm (selectable) |
| Oven Temperature | 190 °C |
| Carrier/Air Supply | Integrated zero-air generator |
| Fuel Gas | Hydrogen (stored in low-pressure metal hydride cartridge, >40 h operation per cartridge) |
| Compliance | BImSchV 2nd, 13th & 17th Ordinances, EN 12619, EN 13526, EPA Method 25A, EPA Method 503 |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | OVF3000-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Portable Real-Time Analyzer |
| Typical Configuration | Total Volatile Organic Compounds (TVOC) Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Detector Sensitivity | 1 ppm full-scale for CH₄ |
| Heating Chamber Temperature | 190 °C |
| Built-in Air Supply | Yes |
| Operating Time per Hydrogen Cartridge | >40 h |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | VE7 |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10, 0–100, 0–1,000, 0–10,000, 0–100,000 ppm (CH₄ equivalent) |
| Full-Scale Sensitivity | ≤1 ppm CH₄ |
| Response Time (T₉₀) | ≤0.2 s |
| Oven Temperature | 190 °C |
| Carrier/Combustion Air Supply | Integrated zero-air generator |
| Compliance | BImSchV 2nd, 13th & 17th Ordinances |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Instrument Type | Online Analyzer |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Target | Total Volatile Organic Compounds (TVOC) and Non-Methane Hydrocarbons (NMHC) |
| Detection Range | 0–1000 ppm (expandable to 0–100,000 ppm) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| FID Sensitivity | ≤1 ppm CH₄ full scale |
| Oven Temperature | 190 °C |
| Carrier/Combustion Air | Integrated zero-air generator |
| Sample Conditioning | Heated sample line & filter with automated back-purge |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VE7-2 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Typical Configuration | Total VOC Analyzer |
| Measurement Range | 0–1000 ppm (expandable to 0–100,000 ppm) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Detector Sensitivity | ≤1 ppm CH₄ full-scale |
| Oven Temperature | 190 °C |
| Carrier/Burner Air Supply | Integrated zero-air generator |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | W600 |
| Instrument Type | Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Detection Principle | Flame Ionization Detection (FID) |
| Full-Scale Sensitivity (CH₄) | 1 ppm |
| Heating Chamber Temperature | 190 °C |
| Dimensions (W×D×H) | 483 mm × 600 mm × 132 mm |
| Carrier/Air Supply | Integrated zero-air generator |
| Compliance | BImSchV 2nd, 13th & 17th Ordinances (Germany), EN 12619, EN 13526, EPA Method 25A, EPA Method 503 |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | W600-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Configuration | TVOC Monitoring System |
| Measurement Range | 0–1000 ppm (expandable to 100,000 ppm) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Heater Chamber Temperature | 190 °C |
| Dimensions (W×D×H) | 483 × 600 × 132 mm |
| Sensitivity | ≤1 ppm CH₄ full-scale |
| Carrier/Air Supply | Integrated zero-air generator |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-220E |
| Measurement Principle | Photometric Method (based on acetylacetone derivatization) |
| Chamber Volume | 1 m³ |
| Temperature Control Range | 15–30 °C (±0.5 °C uniformity) |
| Relative Humidity Control Range | 30–70 % RH (±3 % RH stability) |
| Air Exchange Rate | 0.5–1.5 h⁻¹ (adjustable, calibrated per ISO 12460-1) |
| Internal Surface Material | Stainless Steel 316L with electropolished finish |
| Sample Capacity | Up to 1.0 m² test specimen (standardized board or furniture panel) |
| Compliance | ISO 12460-1, GB/T 17657–2013, ASTM D6007–22, JIS A 1460 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-220E |
| Price Range | USD 14,000 – 42,500 (FOB Shanghai) |
| Detection Principle | Dynamic Chamber Method with Integrated PID/EC Sensor Array |
| Instrument Type | Continuous Online Monitoring System |
| Standard Configuration | Integrated TVOC + Formaldehyde Dual-Channel Analysis Module |
| Humidity Control Range | 30–70% RH |
| Humidity Control Accuracy | ±3.0% RH |
| Humidity Resolution | ±2% RH |
| Airflow Velocity in Chamber | 0.1–0.3 m/s |
| Chamber Volume | 1 m³ (standard), configurable to 0.5–5 m³ |
| Temperature Control Range | 15–35°C (±0.5°C stability) |
| Material | Electropolished 316L Stainless Steel Interior with Silicone-Free Sealing |
| Compliance | Meets ASTM D6007–22, ISO 16000-9:2022, GB/T 18883–2022, and JIS A 1912:2020 requirements for chamber-based emission testing |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-220E |
| Measurement Principle | Photometric Method (Based on Hantzsch Reaction) |
| Temperature Control Range | 15–30 °C (±0.5 °C stability) |
| Humidity Control Range | 40–70 % RH (±3 % RH uniformity) |
| Internal Volume | 220 L |
| Chamber Construction | Stainless Steel 304 inner chamber with double-wall insulation and PID-controlled heating/cooling + humidification/dehumidification system |
| Compliance | Designed to meet ISO 16000-9, GB/T 18204.2–2014, JIS A 1912, and ASTM D6007 requirements for formaldehyde emission testing preconditioning |
