| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JT-108SYFM |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Format | Single-format Strip-Based Assay |
| Wavelength Range | 380–680 nm |
| Detection Time per Sample | ≤ 180 s |
| Photometric Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 8 parallel optical paths |
| Measurement Speed per Channel | < 1 s |
| Inter-batch CV | < 3% |
| Sensitivity Limit | ≤ 0.001 ng/mL (typical for chloramphenicol in honey matrix) |
| Output Metrics | Colorimetric intensity, C/T ratio, Test line (T) signal, Control line (C) signal |
| Power Supply | AC 220 V ±10%, 50 Hz (optional Li-ion battery pack available) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, RJ45 Ethernet, optional 4G LTE module |
| Data Storage | Internal eMMC + microSD slot (up to 128 GB), ≥ 1,000,000 test records |
| Compliance | Designed to support ISO/IEC 17025-aligned laboratory workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | JT-108Y |
| Price | USD 9,200 (approx.) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Compatibility | Universal for Solid & Liquid Food Matrices |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤ 180 seconds per test strip |
| Repeatability | ≤ 0.3% CV |
| Detection Channels | 10 independent optical channels |
| Measurement Speed | < 1 second per channel |
| Output Metrics | Colorimetric intensity, C/T ratio, Test line (T) signal, Control line (C) signal |
| Interface | USB 2.0 |
| Network | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, Optional 4G LTE module |
| Positioning | Integrated GPS/AGPS |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Data Storage | Internal eMMC + microSD slot (up to 512 GB), ≥ 1,000,000 records |
| Display | 10.1-inch capacitive touchscreen, Android OS 11 |
| Printing Options | Thermal label printer (adhesive), thermal roll paper, A4 inkjet-compatible export |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JT-DB10NY |
| Price | USD 1,050 (FOB Shanghai) |
| Measurement Range | 0–1000 ppm |
| Number of Detection Channels | 1 |
| Detection Method | Colloidal Gold Immunochromatography |
| Measurement Accuracy | ±5% |
| Limit of Detection (LOD) | 0.01 ppm |
| Detection Time | <2 s per test |
| Display | 5-inch capacitive touchscreen (Android OS) |
| Power Supply | Rechargeable Li-ion battery (operational autonomy ≥8 h) |
| Data Output | C/T line intensity ratio, chromaticity value, qualitative/quantitative result classification |
| Connectivity | Wi-Fi, Bluetooth 4.2, USB 2.0 |
| Data Management | Cloud synchronization, local storage (≥10,000 records), CSV export |
| Compliance | Aligned with MOA Notice No. 102 (2022), “Three-Year Action Plan for Illegal Drug Control and Residue Reduction in Edible Agricultural Products”, and Technical Guidance for Quality & Safety Control of Cowpea, Leek, and Celery (MOA, 2023) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-K100 |
| Detection Method | Colloidal Gold Immunochromatography |
| Measurement Range | 0.5–1000 ppb |
| Number of Test Lines | 1 |
| Quantitative Accuracy (CV) | ≤1% |
| Limit of Detection (LOD) | 0.5 ppb |
| Brand | Ruixin |
|---|---|
| Model | JT-K10SY |
| Origin | Shanghai, China |
| Type | Lateral Flow Immunoassay (LFIA) Test Strip |
| Format | Single-use, qualitative/semi-quantitative rapid detection card |
| Pack Size | 20 tests per box |
| Detection Principle | Colloidal gold-labeled antibody-based competitive or sandwich immunoassay |
| Target Analytes | Chloramphenicol (0.1 ppb), Malachite Green (0.5 ppb), Diazepam (0.5 ppb), Fluoroquinolones (3 ppb), Olaquindox metabolite (2 ppb), Furazolidone metabolite (0.5 ppb), Furaltadone metabolite (0.5 ppb), Nitrofurantoin metabolite (0.5 ppb), Nifursol metabolite (0.5 ppb), Sulfonamides (5 ppb), Tetracyclines (10 ppb), Penicillins (20 ppb), Diethylstilbestrol (10 ppb), Enrofloxacin (10 ppb), Ofloxacin (1 ppb), Ciprofloxacin (10 ppb), Sarafloxacin (40 ppb), Danofloxacin (50 ppb), Amantadine (2 ppb), Dexamethasone (1 ppb), Chlorpromazine (10 ppb), Florfenicol (0.2 ppb), Metronidazole (3 ppb), Tilmicosin (10 ppb), Clopidol (200 ppb), Streptomycin (20 ppb), Gentamicin (10 ppb), Erythromycin (20 ppb), Oxytetracycline (20 ppb), Chlortetracycline (100 ppb), Sulfadimidine (25 ppb), Ceftiofur (100 ppb), Cefotaxime (200 ppb), Ceftriaxone (50 ppb), Ampicillin (50 ppb), Amoxicillin (20 ppb), Sodium Pentachlorophenate (1 ppb), Avermectins (20 ppb), Thiamphenicol (50 ppb), Apramycin (100 ppb), Methyltestosterone (100 ppb), Nicarbazin (20 ppb), Hydrocortisone (1 ppb), Albendazole (10 ppb), Tylosin (100 ppb), Microcystin-LR (1 ppb), Rosiglitazone (50 ppb), Trimethoprim (50 ppb) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | NC-32ZD |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 32 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm (for methamidophos) |
| Wavelength Options | 340, 410, 450, 510, 546, 630 nm |
| Reaction Temperature | 37 ± 1 °C (software-adjustable) |
| Transmittance Accuracy | ±1.5% |
| Transmittance Repeatability | ≤0.5% |
| Absorbance Drift | ≤0.005 Abs/3 min |
| Inhibition Rate Repeatability | ≤5% |
| Power Supply | AC 100–240 V, 50/60 Hz, 102 W |
| Dimensions | 468 × 270 × 290 mm |
| Weight | ~13 kg |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NCD-100A |
| Price | USD 10,800 (FOB Shanghai) |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Broad-spectrum food & agricultural matrices |
| Wavelength Range | 410–630 nm (with fixed filters at 410, 450, 540, 630 nm |
| Assay Time | ≤180 seconds per 96-well plate |
| Photometric Repeatability | ±1.0% CV or ±0.007 Abs |
| Detection Channels | 96 / 48 / 24-well configurable microplate format |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | NCD-96DY |
| Detection Principle | Enzyme-Linked Immunosorbent Assay (ELISA) |
| Wavelength Range | 400–1100 nm |
| Optical Channels | 96-well microplate format |
| Photometric Accuracy | ±0.005A (repeatability, 0–2A) |
| Measurement Range | 0.000–4.000 Abs |
| Resolution | 0.001 Abs |
| Wavelength Accuracy | ±2.0 nm |
| Bandwidth | 8 ±1.0 nm |
| Inter-channel Variation | ≤0.02A |
| Stability | ≤0.005A/hour |
| Stray Light | ≥2.0A at 510 nm (50.0 g/L NaNO₂) |
| Read Time | ≤5 s per plate |
| Data Storage | ≥100,000 test records |
| Calibration Curves | Up to 126 stored protocols |
| Analysis Modes | Qualitative (positive/negative), quantitative (concentration, P/CO, cutoff), semi-quantitative |
| Curve Fitting Algorithms | 9 methods including linear, logit-log, 4PL, quadratic, exponential regression |
| Interface | RS-232, USB |
| Software Compliance | Supports FDA 21 CFR Part 11 audit trail (via PC-hosted Ruixin ELISA Manager v3.x), GLP/GMP data integrity features |
| Regulatory Alignment | Compatible with ISO 15197, CLSI EP12-A2, and veterinary diagnostic validation frameworks per OIE Terrestrial Manual |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | NCD-96S |
| Function Type | Multi-analyte Quantitative & Qualitative Detection |
| Sample Compatibility | Universal for Animal-Derived Food Matrices |
| Wavelength Range | 400–1100 nm |
| Detection Time | ≤3 min per 96-well plate |
| Photometric Repeatability | ±0.005 A (0–2 A) |
| Detection Channels | 96-well microplate format |
| Optical System | Auto-calibrating 8-channel photometric system with standard filters at 405/450/492/630 nm (expandable to 10 filters) |
| Light Source | Quartz halogen lamp with auto-dimming idle mode |
| Absorbance Range | 0.000–4.000 A |
| Resolution | 0.001 A |
| Accuracy | ±1% (0–2 A) |
| Linearity Error | ±0.1% (0–2 A) |
| Inter-channel Variation | ≤0.02 A |
| Stability | ≤0.005 A/h |
| Stray Light | ≥2.0 A at 510 nm using 50.0 g/L sodium nitrite solution |
| Plate Read Time | 5 s |
| Data Storage | ≥100,000 test records |
| Analysis Methods | 9 algorithmic models including linear regression, semi-log, log-log, ratio-based, exponential, and quadratic curve fitting |
| Compliance Support | Configurable audit trail, user access levels, and data export compliant with GLP documentation workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RFE-3 |
| Price Range | USD 4,200 – 7,000 |
| Detection Range | 0–9999 RLU |
| LOD | 1×10⁻¹⁶ mol ATP |
| Detection Time | 10 s |
| Repeatability | CV ≤ 8% |
| Detection Channels | 1 |
| Display | LCD |
| Detection Principle | Bioluminescent reaction between ATP and luciferin-luciferase complex |
| Communication Interface | RS232 (Wi-Fi optional per firmware upgrade) |
| Power Supply | Rechargeable Li-ion battery |
| Form Factor | Handheld |
| Net Weight | 400 g |
| Light Source | LED |
| Sample Volume | 1 mL per swab |
| Swab Tube Dimensions | Ø12 × 155 mm |
| Data Storage | 2000 records |
| Limit Sets | 100 user-defined thresholds |
| Operating Temperature | 0–60 °C |
| Relative Humidity | 15–95% RH |
| Battery Life | ≥200 h (AA alkaline, 2 pcs) or equivalent Li-ion cycle |
| Output Units | RLU and configurable CFU (via user-defined conversion factor) |
| Compliance | ISO 15161:2001 (Food & Beverage sector application of ISO 9001), aligned with ISO 22000 hygiene validation requirements |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | RSY-1 |
| Price Range | USD 1,400–2,800 |
| Function Type | Single-parameter Detection |
| Sample Type | Single-species Dedicated |
| Detection Time | ≤3 min per sample |
| Repeatability | ≤0.3% (70–80% w/w moisture range) |
| Measurement Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RXHGZ-V1.0 |
| Detection Method | Rapid Colorimetric Assay |
| Measurement Range | 0–100% (Relative Inhibition) |
| Number of Channels | Multi-channel |
| Measurement Error | ±10% |
| Limit of Detection (LOD) | 0.05 ppm |
| Printing Medium | Thermal Adhesive Label Paper |
| Connectivity | Bluetooth 4.2 |
| Paper Width | 25–80 mm |
| Printable Width | 72 mm |
| Max Roll Diameter | 50 mm |
| Print Speed | 70 mm/s (Receipt), 40 mm/s (Label) |
| Power Supply | Rechargeable Built-in Lithium-ion Battery |
| Brand | RuiXin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SJ-LH221 |
| Price | USD 37 (excl. tax & shipping) |
| Detection Range | 1–50 ppm |
| Limit of Detection (LOD) | 1 ppm |
| Assay Format | Colorimetric Lateral Flow Immunoassay |
| Test Capacity | 50 tests per kit |
| Intended Use | Qualitative/semi-quantitative detection of residual oxalic acid in rinse water or surface swabs from Chinese mitten crab (*Eriocheir sinensis*) processed with oxalic acid–containing washing powder |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-1001AC |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Function Type | Multi-analyte Quantitative Detection System |
| Sample Compatibility | Solid and Liquid Extracts from Tea, Leafy Produce, and Herbal Matrices |
| Wavelength Range | 410–630 nm |
| Detection Time per Sample | ≤ 180 s |
| Photometric Repeatability | ≤ 1.0% (Transmittance) |
| Optical Channels | 8 independent photometric channels |
| Absorbance Accuracy | ±2.0% T |
| Dark Current Drift | ≤0.5% over 3 min |
| Detection Limits | 5.0 mg/kg for all listed analytes |
| Linear Dynamic Range | 0–200 mg/kg (pyrethroids, organophosphates) |
| Brand | Ruixin |
|---|---|
| Model | SP-1001T |
| Origin | Shanghai, China |
| Wavelength Range | 400–680 nm |
| Detection Time | <2 min |
| Repeatability | <5% |
| Detection Channels | 8 |
| Photometric Accuracy | ±2.0% T |
| Photometric Repeatability | 1.0% T |
| Dark Current Drift | 0.5% (3 min) |
| Dimensions | 470 × 280 × 150 mm |
| Function Type | Single-analyte Quantitative Detection |
| Sample Compatibility | Multi-sample Universal Format |
| Interface | USB |
| Data Output | Built-in Thermal Printer + PC Software Integration |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SP-1218D |
| Function Type | Multi-parameter rapid detection (spectrophotometric + dry immunochromatographic gold nanoparticle assay) |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per sample |
| Repeatability | ≤0.3% (photometric), CV <1% (colloidal gold) |
| Detection Channels | 12 independent optical channels |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±0.5% T |
| Photocurrent Drift | ≤0.2% (3 min) |
| Overall Measurement Accuracy | ±5% (vs. reference standards) |
| Colloidal Gold Module | 3 dedicated readers with CT-ratio, colorimetric, and T/C line quantification |
| Connectivity | USB ×3, Wi-Fi, Bluetooth 4.2, 4G LTE |
| Power Supply | AC 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SP-2418D |
| Function Type | Multi-parameter rapid detection (expandable to 100+ assays) |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per assay |
| Photometric Repeatability | ≤0.2% T |
| Optical Channels | 24 independent photometric channels |
| Colloidal Gold Reader Modules | 3 standard (expandable to 10) |
| Display | 10.1″ capacitive touchscreen (Android OS) |
| Data Connectivity | RJ45 Ethernet, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, 4G LTE Cat.4 |
| Power Supply | AC 220 V ±10% |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±2.0% T |
| Photocurrent Drift | ≤0.2% (3 min) |
| Overall Measurement Accuracy | ±5% (relative to reference methods) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SP-801B |
| Function Type | Multi-parameter (60+ configurable assays) |
| Sample Compatibility | Universal for liquid, extract, and homogenized food matrices |
| Wavelengths | 410 nm, 510 nm, 630 nm |
| Detection Time per Channel | ≤ 180 s |
| Photometric Repeatability (Transmittance) | ≤ 0.2% |
| Absorbance Resolution | 0.001 AU |
| Transmittance Resolution | 0.01% |
| Optical Accuracy (Transmittance) | ±2.0% |
| Baseline Stability (3 min) | ≤0.2% |
| Detection Channels | 24 simultaneous cuvette-based optical paths |
| Display | 7.0-inch capacitive touch TFT-LCD (800×480) with full Chinese UI |
| Data Output | Embedded thermal printer, RS232, USB 2.0 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SP-801D |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per assay |
| Photometric Repeatability | ≤0.3% (T) |
| Optical Channels | 8 independent photometric channels + 1 integrated colloidal gold lateral flow reader |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Absorbance Resolution | 0.001 A |
| Transmittance Resolution | 0.01% T |
| Photometric Accuracy | ±2.0% (T) |
| Dark Current Drift | ≤0.3% over 3 min |
| Measurement Accuracy | ±5% (relative to reference standards) |
| Operating System | Android 9.0 or Windows 10 IoT Enterprise (pre-installed) |
| Storage | 32 GB eMMC (expandable to 64 GB) |
| RAM | 2 GB DDR4 |
| Connectivity | Dual-band Wi-Fi (802.11 a/b/g/n/ac), Bluetooth 5.0, optional 3G/4G LTE module |
| Power Supply | AC 220 V ±10% / Internal rechargeable Li-ion battery (5 h continuous operation) |
| Display | 10.6-inch capacitive multi-touch LCD (1920×1080) |
| Compliance | Designed for GLP-aligned workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | SP-801SC |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-analyte Rapid Detection System |
| Sample Format | Single-sample per test cycle |
| Wavelengths | 410 nm, 510 nm, 630 nm |
| Assay Time | ≤ 180 s per sample |
| Photometric Repeatability | ≤ 0.2% (Transmittance), ≤ 0.3% (Absorbance) |
| Detection Channels | 8 parallel optical paths |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-B |
| Price | USD 1,800 (approx.) |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Universal for Fresh and Processed Meat Samples |
| Wavelength Range | 410–630 nm |
| Assay Time | ≤ 3 min per sample |
| Photometric Repeatability | ≤ 0.2% |
| Detection Channels | 8 independent optical channels |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-CHN |
| Price | USD 780 (approx.) |
| Functionality | Single-analyte, dedicated assay |
| Sample Format | Homogenized tissue extract (liquid phase) |
| Wavelength Range | 400–680 nm |
| Assay Time | <120 s per sample |
| Coefficient of Variation (CV) | <5% |
| Detection Channels | 1 |
| Detection Limit | 10 mg/100 g in fish and aquatic animal tissues |
| Linear Range | 10–200 mg/100 g (typical for enzymatic/colorimetric histamine assays) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-FM2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-analyte Quantitative Detection |
| Sample Type | Dedicated to Honey Matrix Only |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds per sample |
| Photometric Repeatability | ≤ 0.2% CV |
| Detection Channels | 1 |
| Display | 4.3-inch Color TFT Touchscreen |
| Absorbance Range | 0.000–4.000 (Resolution: 0.001) |
| Transmittance Range | 0.00–100.00% (Resolution: 0.01%) |
| Photometric Accuracy | ±2.0% T |
| Photometric Stability | ≤0.3% drift over 3 min |
| Detection Limits & Ranges | Fructose + Glucose — LOD 12.0%, Range 0–95.0% w/w |
| Interface | RS-232, USB 2.0 |
| Power Options | Internal Rechargeable Li-ion Battery, DC 5 V Input, AC 220 V ±10% 50/60 Hz |
| Dimensions & Weight | 220 × 160 × 85 mm |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SP-GYS2 |
| Wavelength Range | 400–680 nm |
| Detection Time | <2 min |
| Repeatability | <5% |
| Detection Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Stability (3 min) | ≤0.3% |
| Peroxide Value Detection Limit | 0.05 g/100g |
| Peroxide Value Range | 0.05–5.00 g/100g |
| Acid Value Detection Limit | 0.1 mg KOH/g |
| Acid Value Range | 0.0–30.0 mg KOH/g |
| Interface | RS232, USB |
| Power Supply | AC 220 V |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-NH2 |
| Price | USD 780 (FOB Shanghai) |
| Functionality | Single-Analyte Detection System |
| Sample Format | Single-sample cuvette-based assay |
| Wavelength Range | 400–680 nm |
| Analysis Time | <120 s per sample |
| Relative Standard Deviation (RSD) | <5% |
| Detection Channels | 1 |
| Detection Limit | 200.0 mg/kg |
| Quantification Range | 0–15,000 mg/kg |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Photometric Repeatability | ≤1.0% |
| Dark Current Drift | ≤0.5% over 3 min |
| Power Supply | AC 220 V / DC 12 V (with rechargeable 12 V Li-ion battery) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SP-Z2 |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Type | Dedicated to Milk Powder & Liquid/Processed Dairy Matrices |
| Wavelength | 540 nm (Fixed-Channel Photometric Detection) |
| Assay Time | ≤180 seconds per sample |
| Photometric Repeatability | ≤0.2% CV |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | SPb-201FM |
| Wavelength Range | 400–680 nm (discrete fixed wavelengths at 410 nm, 510 nm, 630 nm) |
| Detection Time | <2 min per sample |
| Repeatability | ≤5% CV |
| Optical Resolution | Absorbance 0.001 AU |
| Absorbance Range | 0.000–4.000 AU |
| Transmittance Range | 0.00–100.00% |
| Photometric Accuracy | ±2.0% T |
| Photometric Stability | ≤0.2% T (3 min) |
| Detection Channels | 1 |
| Sample Type | Liquid honey (pre-diluted or direct injection per protocol) |
| Compliance | Designed for routine QC in food processing labs compliant with GB 14963–2011 (Chinese National Standard for Honey), supports internal GLP documentation workflows |
| Connectivity | USB interface for data export |
| Power Supply | 220 V ±10%, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-AJ2 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Throughput | Single-Sample Mode |
| Optical Wavelength | 410 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% (Transmittance) |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-BH2 |
| Price | USD 1,080 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Type | Dedicated Single-Sample Format |
| Wavelength | 540 nm |
| Detection Time | ≤ 3 minutes |
| Photometric Repeatability | ≤ 0.2% |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-BJ2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Format | Single-Sample Mode |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% (at 540 nm) |
| Detection Channels | 1 |