| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SP-15VSC |
| Pricing | Upon Request |
| Input Voltage | 220 V AC, 50/60 Hz, single-phase |
| Max Operating Current | 40 A |
| Max Oscillation Power | 15 kW |
| Max Input Power | 7 kW |
| Output Frequency Range | 30–80 Hz (adjustable) |
| Duty Cycle | 80% |
| Induction Coil Dimensions | 70 mm OD × 65 mm ID × 80 mm H |
| Programmable Timings | Heating (1–99 s), Holding (1–99 s), Cooling (1–99 s) |
| Cooling | Rear-mounted fan + external chiller (16 L/min flow, 2–35 °C range, 6 L stainless steel tank) |
| Safety Protections | Automatic water-pressure interlock, overtemperature cutoff, over-power shutdown |
| Vacuum System | Dual-stage rotary vane pump (156 L/min, ultimate vacuum ≤10⁻⁴ Torr, 208–240 V AC, 4 kW) |
| Vacuum Chamber | Semi-open quartz tube (7 mm OD × 4 mm ID × 500 mm L), mounted via KF25 flange with high-temp silicone O-ring seal, integrated vacuum gauge & dual needle valves |
| Suction Casting Capability | Produces 3–5 mm diameter alloy rods up to 150 mm in length via manual piston-driven suction |
| Maximum Casting Temperature | <1200 °C (to prevent quartz degradation) |
| Crucible | 1.5″ OD × 1.25″ ID × 3.75″ deep graphite crucible (30 mm OD × 24 mm ID × 26 mm H) |
| Refractory Liner | 5 mm alumina-based insulating liner (base support, crucible sleeve, and lid included) |
| Observation Port | Φ12 mm viewport on top flange |
| Pressure Relief | Integrated safety valve (max operating pressure ≤0.02 MPa) |
| Overall Footprint | Induction unit: 800 × 600 × 1000 mm |
| Chiller | 460 × 475 × 762 mm |
| Mobile platform | 600 × 800 mm |
| Net Weight | 135 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-25TC |
| Pricing | Upon Request |
| Maximum Input Power | 25 kW |
| Operating Frequency Range | 30–80 kHz |
| Continuous Working Temperature | 1000–2000 °C |
| Max. Short-Term Temperature | 1700 °C (<30 min) |
| Temperature Control Accuracy | ±5 °C |
| Programmable Ramp Segments | 30 |
| Max. Heating Rate | 1 °C/s (0–1000 °C), 0.5 °C/s (1200–1700 °C) |
| Quartz Tube Dimensions | Ø100 mm OD × Ø92 mm ID × 355 mm L |
| Graphite Crucible | Ø40 mm OD × Ø37.1 mm ID × 100.5 mm H |
| Vacuum System | Dual-stage rotary vane pump (120 L/min, base pressure 10⁻² torr) |
| Cooling | Recirculating chiller (12 L stainless steel tank, 16 L/min flow, 5–30 °C setpoint) |
| Safety Protections | Auto water-pressure cutoff, over-temperature shutdown, over-power limiter, thermocouple break detection |
| Compliance | Designed for ISO/IEC 17025-compliant lab environments |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SP-25VIM |
| Pricing | Available Upon Request |
| Induction Heater | SP-25A (2–25 kW, 30–80 kHz) |
| Cooling System | Integrated Chiller (4 L/min, 4 L reservoir, 5–35 °C) |
| Vacuum System | 550 W Pump (226 L/min) with KF25 Flange |
| Quartz Crucible | Ø36 mm ID × 78 mm H (79 mL capacity) |
| Quartz Tube | Ø75 mm ID × 300 mm L |
| Induction Coil | Ø85 mm ID × 50 mm H |
| Operating Vacuum Level | ≤5 × 10⁻² mbar (with standard pump) |
| Argon Purity Requirement | ≥99.99% |
| Max Sample Mass | ~100 g (steel equivalent) |
| Safety Protections | Auto-shutdown on overpressure, overtemperature, coolant flow loss, and power overload |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | SP-MSM-130 |
| Pricing | Upon Request |
| Brand | KJ GROUP |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-MSM32 |
| Pricing | Upon Request |
| Vacuum Glove Box Dimensions | 1200 × 900 × 750 mm (W×D×H), Front-Opening |
| Transition Chamber | 360 × 600 mm / 150 × 300 mm |
| Purification Capacity | H₂O/O₂ < 1 ppm (auto-regenerating) |
| Oxygen Analyzer Accuracy | ±0.1 ppm (0–999 ppm range) |
| Arc Electrode | Ø4 mm tungsten, water-cooled |
| Electrode Travel Range | ≥200 × 400 × 50 mm (X-Y-Z) |
| Water-Cooled Crucibles | 32 × Ø25 mm |
| Max Melting Temperature | 3000 °C |
| Adjustable Output Current | 10–250 A (AC 220 V, 50 Hz) |
| Optional Power Supply | 300 A (AC 380 V, 50 Hz) |
| Cooling System | KJ-5000 recirculating chiller |
| Protective Atmosphere | 5N Ar or 5% H₂ + 95% Ar |
| Safety | Integrated UV/IR shielding, mandatory eyewear during operation |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPC-1 |
| Pricing | Upon Request |
| Max Print Area | 70 mm × 50 mm |
| Min Print Area | 16 mm × 12 mm |
| X/Y Adjustment Range | ±20 mm (±0.01 mm resolution) |
| Z Adjustment Range | 3 mm (±0.05 mm resolution) |
| Screen Angle Adjustment | ±10° |
| Substrate Holding | Vacuum Chuck |
| Frame Dimensions (Top Outer) | 180 mm × 130 mm |
| Frame Dimensions (Bottom Outer) | 125 mm × 108 mm |
| Overall Dimensions (Closed) | 300 mm × 240 mm × 170 mm |
| Overall Dimensions (Open) | 300 mm × 240 mm × 330 mm |
| Weight | 11 kg |
| Operating Ambient | Altitude < 1000 m, Temperature 10–40 °C, Relative Humidity 45–65 %RH |
| Power Supply | AC 380 V, 50 Hz, 63 A circuit breaker with dedicated earth ground |
| Cooling | Integrated recirculating chiller (deionized or distilled water) |
| Process Gas | High-purity argon (≥99.99 %), supplied via Ø6 mm double-ferrule fitting |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPC-32 |
| Pricing | Upon Request |
| Power Supply | Single-phase AC 208–240 V, 50/60 Hz |
| Rated Power | 2500 W |
| Print Table Dimensions | 330 mm × 400 mm |
| Maximum Print Area | 200 mm × 300 mm |
| Print Height Adjustment Range | 30 mm |
| Production Throughput | 300–500 pcs/h |
| Repeatability Accuracy | ±0.03 mm |
| Environmental Operating Conditions | Altitude <1000 m |
| Cooling | Integrated recirculating chiller (deionized or purified water) |
| Gas Requirement | Argon purge (≥99.99% purity), supplied via external cylinder with Ø6 mm dual-ferrule compression fitting |
| Electrical Safety | Dedicated 63 A circuit breaker, mandatory earth grounding |
| Mechanical Guidance | Precision linear rails with variable-frequency motor drive |
| 刮刀 System | Pneumatically assisted floating squeegee assembly with adjustable pressure and stroke speed |
| Alignment | Micrometer-driven X/Y/Z fine alignment stage for PCB-to-screen registration |
| Dual-side Independent Adjustment | Left/right independent lateral offset control for asymmetric or multi-size mesh frame compatibility |
| Brand | KJ GROUP |
|---|---|
| Model | SR-C Series |
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-Made) |
| Light Source | High-Intensity Halogen Lamp |
| Spectral Range | SR-CV: 380–800 nm |
| SR-CN | 650–1100 nm |
| Thickness Measurement Range | SR-CV: 50 nm – 20 µm |
| SR-CN | 100 nm – 200 µm |
| Measurement Time | <1 s |
| Spot Size | 0.5–3 mm |
| Repeatability | 0.1 nm (on 100 nm SiO₂/Si reference) |
| Absolute Accuracy | ±1 nm or 0.5% |
| Incidence Geometry | Normal Incidence (0°) |
| Key Algorithms | FFT-based thick-film analysis |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | STX-1200-A |
| Pricing | Available Upon Request |
| Rated Load Capacity | ≤30 kg |
| A-Axis Rotation Speed | 0–30 rpm (adjustable) |
| A-Axis Oscillation Angle | ±5° to ±23° (adjustable) |
| A-Axis Oscillation Frequency | 20 cycles/min |
| Rotary Platform Diameter | Ø200 mm / Ø400 mm |
| Max. Rotary Cutting Diameter | Ø380 mm |
| Max. Oscillating Cutting Envelope | 180 mm (Y) × 260 mm (X) × 260 mm (Z) |
| Operating Ambient | Altitude ≤1000 m |
| Structural Material | Anodized Aluminum Alloy |
| Noise Level | Low |
| Power Consumption | Low |
| Positional Stability | High Reproducibility |
| Compliance | Designed for integration with STX-1203 Fully Automated Diamond Wire Saws |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Model | STX-203 |
| Power Supply | AC 220 V, 50 Hz, 10 A |
| Total Power Consumption | 120 W (excl. air compressor) |
| Diamond Wire Length | ≤45 m |
| Wire Diameter | ≤0.45 mm |
| Wire Tensioning | Pneumatically adjustable |
| Main Spindle Rotation | Reciprocating |
| Spindle Speed | 2–300 rpm (adjustable) |
| Cutting Feed Rate | 0.05–40 mm/min |
| Return Speed | 1–40 mm/min |
| Z-axis Stroke | ≤60 mm |
| Y-axis Stroke | 0.01–50 mm |
| Rotary Stage | 0–360° horizontal (motorized) |
| Tilt Stage | ±10° (motorized) |
| Maximum Workpiece Size | Φ50 × 50 mm |
| Sample Holder Dimensions | 80 × 51 × 12 mm |
| Max Cutting Depth | ≤50 mm |
| Control System | PLC + 7-inch HMI touchscreen |
| Integrated Video Monitoring | 7-inch display |
| Frame Material | Aluminum alloy with sheet metal enclosure |
| Machine Dimensions (L×W×H) | 730 × 680 × 970 mm |
| Net Weight | 130 kg |
| Operating Environment | 0–45 °C, 10–85% RH (non-condensing) |
| Required Utilities | Compressed air ≥0.6 MPa, cutting oil coolant, grounded AC supply, stable vibration-isolated bench (≥150 kg capacity) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | STX-605B |
| Pricing | Upon Request |
| Wire Length | 150 m |
| Maximum Sample Diameter | Φ150 mm |
| Max Sample Weight | 3 kg |
| Wire Speed | 0–5 m/s |
| Z-Axis Travel | ≤160 mm |
| Y-Axis Travel | ≤180 mm |
| Pneumatic Tension Range | 0.1–0.4 MPa |
| Diamond Wire Diameter Compatibility | <0.45 mm |
| Electric Rotary Stage | 0–360°, Repeatability ±0.02° |
| Electric Tilting Stage | ±10°, Repeatability ±450″ |
| Ambient Operating Conditions | Altitude <1000 m, Temp. 25°C ±15°C, RH 55% ±10%, AC220V/50Hz, Compressed Air (0–1 MPa), Ventilation Required |
| Dimensions (W×D×H) | 617×620×1500 mm |
| Net Weight | 183 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYJ-01DS |
| Pricing | Available Upon Request |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYJ-200H Manual High-Speed Cutting Machine + UNIPOL-830 Dual-Plate Grinding/Polishing Machine |
| Pricing | Contact for Quotation |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Series | Economy-Series Integrated Metallography System |
| Pricing | Contact for Quotation |
| Brand | KJ GROUP |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYJ-D8000 |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 0.75 kW |
| Motor | AC 220 V Variable-Frequency Drive, 1390 rpm |
| Max Wire Speed | 15 m/s (adjustable) |
| Main Platform Dimensions | 500 mm × 425 mm |
| Sliding Stage Dimensions | 240 mm × 200 mm |
| Y-Axis Travel | >200 mm |
| Max Cutting Depth | 200 mm (main platform), 150 mm (sliding stage) |
| Max Sample Volume (sliding stage) | 200 mm × 200 mm × 200 mm |
| Standard Diamond Band Blade | 0.9 mm diamond segment thickness / 0.45 mm base band thickness × 10 mm width × 2780 mm length |
| Control Interface | Front-panel tactile buttons |
| Unit Dimensions (W×D×H) | 920 mm × 700 mm × 1600 mm |
| Net Weight | ≈245 kg |
| Operating Environment | 0–45 °C, 10–85 % RH (non-condensing) |
| Cooling | Integrated recirculating pump + reservoir (no external water supply required) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SYJ-DS100 |
| Pricing | Upon Request |
| Cutting Stroke | 100 mm |
| Adjustable Diamond Scribe Height | Yes |
| Spring-Loaded Downforce Control | Yes |
| Operating Environment | Altitude ≤ 1000 m, Temperature 25 °C ± 15 °C, Relative Humidity 55 %RH ± 10 %RH |
| Footprint | 300 mm × 300 mm Work Surface |
| Dimensions (L×W×H) | 210 mm × 210 mm × 140 mm |
| Power Requirement | None |
| Water/Gas Requirements | None |
| Ventilation | Required |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYU-3 |
| Price | Upon Request |
| Operating Frequency | 38 kHz |
| Maximum Sample Load | 1 kg |
| Total Current Draw | ≤0.6 A |
| Motor Speed | 1400 RPM |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Included Sieves | 100, 200, and 450 mesh (ID 200 mm × H 50 mm) |
| System Dimensions | 360 × 300 × 740 mm |
| Ultrasonic Generator Dimensions | 350 × 300 × 200 mm |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Target Head |
| Pricing | Upon Request |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TEM-APT Holder |
| Pricing | Available Upon Request |
| Sample Compatibility | FIB-prepared needle specimens & electrochemically sharpened tips |
| Rotation Range | 360° continuous tilt |
| TEM Interface | Standard 3.5 mm diameter Gatan-style or JEOL-compatible double-tilt compatible geometry |
| APT Transfer Compatibility | Direct insertion into CAMECA LEAP or AMETEK IVAS systems |
| Structural Material | High-purity molybdenum alloy with low-outgassing surface finish |
| Vacuum Compatibility | UHV-rated (≤1×10⁻¹⁰ mbar) |
| Thermal Stability | Engineered for cryogenic operation (77 K–100 K) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TF200 |
| Pricing | Available Upon Request |
| Wavelength Ranges | TF200-VIS: 380–1050 nm |
| TF200-EXR | 380–1700 nm |
| TF200-DUV | 190–1100 nm |
| TF200-XNIR | 900–1700 nm |
| Thickness Range | 1 nm – 3 mm (model-dependent) |
| Accuracy | Max(0.4% of thickness, 2 nm) for TF200-VIS/EXR/DUV |
| Precision | 0.2 nm (VIS/EXR/DUV), 3 nm (XNIR) |
| Incidence Angle | 90° (normal incidence) |
| Sample Compatibility | Transparent or semi-transparent films |
| Measurement Modes | Reflectance and transmittance |
| Spot Size | 2 mm (optional micro-spot accessory available) |
| In-line Capability | Yes |
| Scanning Options | XY motorized stage (optional) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TMVS-1S |
| Pricing | Upon Request |
| Test Forces | 10 gf (0.098 N), 25 gf (0.245 N), 50 gf (0.49 N), 100 gf (0.98 N), 200 gf (1.96 N), 300 gf (2.94 N), 500 gf (4.9 N), 1 kgf (9.8 N) |
| Standards Compliance | GB/T 4340, ASTM E92 |
| Measurement Resolution | 0.01 µm |
| Hardness Range | 8–2900 HV |
| Indentation Force Application | Fully Automatic (Loading–Dwell–Unloading) |
| Dwell Time | 1–99 s |
| Max Specimen Height | 100 mm |
| Distance from Indenter to Column | 130 mm |
| X-Y Stage | 100 × 100 mm (25 × 25 mm travel) |
| Optical Magnifications | 100× (observation), 400× (measurement) |
| Illumination | Continuously Adjustable LED Brightness |
| Hardness Scale Conversion | HV ↔ HK ↔ HRB/HRC ↔ HB |
| Dimensions | 540 × 260 × 650 mm |
| Weight | ~50 kg |
| Power Supply | AC 220 V ±5%, 50–60 Hz |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TW-3A |
| Pricing | Available Upon Request |
| Power Supply | 110 V / 220 V AC, 360 W |
| Pumping Speed | 6.6 CFM (187 L/min) |
| Ultimate Vacuum | 0.075 Torr (10 Pa) |
| Motor Speed | 1720 rpm |
| Oil Reservoir Capacity | 20 mL |
| Operating Temperature Range | –5 °C to 40 °C |
| Inlet Port Diameter | 6.35 mm (¼″ NPT compatible) |
| Inlet Thread | M12 × 1.25 mm |
| Dimensions (L × W × H) | 340 × 135 × 260 mm |
| Net Weight | 9.8 kg |
| Optional Accessory | Oil Mist Filter (KJ-FIL-OMF) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | U-Series |
| Pricing | Available Upon Request |
| High-Pressure Chamber ID | 100 mm / 150 mm |
| Effective Chamber Depth | 300 mm |
| Max Operating Pressure | 100–400 MPa |
| Pressure Control Accuracy | High-Precision Programmable Ramp/Soak Profile |
| Pressure Cycling Data Logging | Full Traceability with Timestamped Curve Export |
| Lifting Mechanism | Fully Automated Sample Handling |
| Pressurization Method | Single-Stage Hydraulic Intensification |
| Pressure Ramp Rate | Segment-wise Adjustable (MPa/s) |
| Stored Process Recipes | Multiple User-Defined Protocols |
| Working Fluid | Hydraulic Oil or Water-Based Emulsion |
| Fluid Replenishment | Auto-Refill During Cycle |
| Chamber Construction | Pre-Stressed Steel Wire-Wound Vessel |
| Frame Construction | Pre-Stressed Steel Wire-Wound Monocoque |
| Safety Valves | Redundant Fail-Safe Design |
| HMI | 7-inch Full-Color Touchscreen Interface |
| Data Export | USB 2.0 Port |
| Emergency Functions | Dual-Channel E-Stop + Rapid Depressurization |
| Drive Power | 9 kW |
| Footprint | ≤2.5 m² |
| Height | <1.5 m |
| Overall Dimensions (CIP-100MA) | 1750 × 1190 × 1370 mm |
| Overall Dimensions (CIP-150MA) | 2000 × 1350 × 1500 mm |
| Net Weight (CIP-100MA) | <2.5 t |
| Net Weight (CIP-150MA) | <3.75 t |
| Benchtop Variant Dimensions | 450 × 420 × 1010 mm |
| Benchtop Variant Weight | 200 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VGB-1 |
| Pricing | Available Upon Request |
| Chamber Dimensions | 560 mm × 430 mm × 410 mm |
| Front-Loading Antechamber Dimensions | Standard Integrated |
| Construction Material | 304 Stainless Steel (3 mm thickness) |
| Chamber Reinforcement | Internal Structural Ribs |
| Vacuum Performance (Main Chamber) | ≤0.5 torr (with mechanical pump) |
| Vacuum Performance (Antechamber) | ≤0.05 torr |
| Moisture Level (under inert purge) | <180 ppm H₂O |
| Oxygen Level (under inert purge) | <200 ppm O₂ |
| Leak Rate | 6 torr/h |
| Maximum Positive Pressure | 1.1 atm |
| Power Interface | 3-pin IEC C14 inlet (external) feeding internal 1500 W rated 3-outlet power strip |
| Certified | CE compliant |
| Net Weight | 95 kg |
| Overall Footprint | 940 mm × 480 mm × 490 mm |
| Standard Accessories | 2 pairs nitrile/rubber gloves (1 pair pre-installed) |
| Optional Accessories | Rotary vane vacuum pump, stainless steel bellows |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VGB-10-I |
| Pricing | Available Upon Request |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 3000 W |
| Main Chamber Dimensions (W×D×H) | 1200 mm × 800 mm × 930 mm |
| Overall Unit Dimensions (W×D×H) | 2150 mm × 970 mm × 1900 mm |
| Standard Transfer Chamber | 385 mm × 588 mm |
| Tool Transfer Chamber | Ø150 mm × 300 mm |
| Viewing Window | Dual-laminated tempered safety glass, 12 mm thick, corrosion-resistant film laminated on interior surface |
| Lighting | Philips fluorescent lamp |
| HEPA Filter | ISO Class 5 compliant, 0.3 µm particle retention efficiency ≥99.99% |
| Organic Solvent Filtration | Integrated activated carbon + HEPA dual-stage filter |
| Moisture Sensor | GE probe, 0–1000 ppm range, ±0.1 ppm resolution, touchscreen display |
| Oxygen Sensor | AII probe, 0–1000 ppm range, ±0.1 ppm resolution, touchscreen display |
| Pressure Transducer | Setra model, −2500 to +2500 Pa range, ±1 Pa accuracy, touchscreen readout |
| Vacuum Pump | Edwards scroll pump, 8.4–12 m³/h pumping speed |
| Gas Purification System | BASF oxygen scavenger + UOP molecular sieve desiccant, fully automated regeneration cycle |
| Internal H₂O Level | ≤1 ppm (at 20 °C, 1 atm) |
| Internal O₂ Level | ≤1 ppm (at 20 °C, 1 atm) |
| Leak Rate | ≤0.05 vol%/h (measured via O₂ ingress rate) |
| Transfer Chamber Ultimate Vacuum | ≤100 Pa |
| Compatible Process Gases | N₂, Ar, He |
| Control Gas | Compressed air or inert gas |
| Reducing Gas | H₂/inert gas mixture (configurable per purification module) |
| Auxiliary Port | KF40 vacuum flange |
| Gloves | North synthetic rubber, certified for chemical resistance and low permeability |
| Shelving | Ceiling-mounted, laterally adjustable, 300 mm × 250 mm tray, positioned ~300 mm below ceiling |
| Control Interface | 6-inch color touchscreen, PLC-based, bilingual (English/Chinese) UI |
| Alarms & Logging | Real-time parameter monitoring, configurable threshold alerts, event-triggered data logging with timestamp |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | VGB-10-II |
| Pricing | Upon Request |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | ~3000 W |
| Main Chamber Dimensions | 2400 mm × 800 mm × 930 mm (W×D×H) |
| Overall Footprint | 3115 mm × 830 mm × 1830 mm (W×D×H) |
| Standard Transfer Chamber | 385 mm × 588 mm |
| Tool Transfer Chamber | Ø150 mm × 300 mm |
| Viewing Window | 12 mm thick laminated tempered safety glass with corrosion-resistant film |
| Lighting | Philips fluorescent tubes |
| HEPA Filter | ISO Class 5 compliant, 0.3 µm particle retention efficiency ≥99.999% |
| Organic Solvent Filtration | Integrated activated carbon + HEPA dual-stage filter |
| Moisture Sensor | GE probe, 0–1000 ppm, resolution 0.1 ppm, touchscreen display |
| Oxygen Sensor | AII probe, 0–1000 ppm, resolution 0.1 ppm, touchscreen display |
| Pressure Transducer | Setra, −2500 to +2500 Pa, accuracy ±1 Pa, touchscreen display |
| Vacuum Pump | Edwards, pumping speed 8.4–12 m³/h |
| Gas Purification System | BASF oxygen scavenger + UOP molecular sieve desiccant, auto-regeneration cycle |
| Leak Rate | ≤0.05 vol%/h (measured via O₂ ingress) |
| Transfer Chamber Vacuum Rating | ≤100 Pa |
| Compatible Process Gases | N₂, Ar, He |
| Reductive Gas Compatibility | H₂/N₂ or H₂/Ar mixtures |
| Control Interface | 6-inch color touchscreen, PLC-based, bilingual (English/Chinese) |
| Glove Material | North-brand synthetic elastomer |
| Optional Accessory | 304 stainless steel universal feedthrough plate with KF40 flanges |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VGB-2Y |
| Pricing | Upon Request |
| Power Supply | AC 110 V / 220 V |
| Main Chamber Dimensions | 875 mm × 480 mm × 500 mm |
| Airlock Chamber Dimensions | 230 mm × 230 mm × 230 mm |
| Overall Footprint | 1150 mm × 500 mm × 500 mm |
| Weight | 25 kg |
| Main Chamber Pressure Control Range | 95 kPa to 101 kPa (adjustable via dual solenoid valves) |
| Operating Pressure Range Relative to Ambient | 98 kPa to 101 kPa |
| Airlock Maximum Positive Pressure | 10 kPa |
| Vacuum Gauges | Dual digital vacuum gauges (main chamber + airlock) |
| Valves | 2 solenoid valves + 1 manual valve (main chamber) |
| Viewing Window Material | Optical-grade polycarbonate |
| Standard Accessories | Pair of elastomeric gloves |
| Optional Accessories | Additional pressure/temperature/humidity sensors |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VGB-3 |
| Pricing | Available Upon Request |
| Construction Material | 304 Stainless Steel (3 mm thickness) |
| Main Chamber Dimensions | 780 × 700 × 650 mm (31" × 28" × 26") |
| Antechamber Dimensions | Not Specified |
| Vacuum Level (Antechamber) | 0.05 Torr (0.067 mbar) |
| Vacuum Level (Main Chamber) | 0.5 Torr (0.67 mbar) |
| Leak Rate | < 6 Torr/hour |
| Inert Gas Retention Time | > 12 hours |
| Maximum Positive Pressure | 1.1 atm (≈ 810 Torr) |
| Internal Power Outlet | 1500 W rated strip with external 3-pin IEC C14 inlet |
| Standard Accessories | Two 6" elastomeric gloves (one installed, one spare) |
| Net Weight | 520 lbs (236 kg) |
| Structural Reinforcement | Integrated stiffening ribs |
| Port Configuration | Two KF25 vacuum ports + three ball valves (main chamber) |
| Operating Limitation | Not designed for high-vacuum applications (< 10⁻³ Torr) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VGB-4 |
| Pricing | Upon Request |
| Chamber Material | 3 mm 304 stainless steel with welded reinforcement ribs |
| Main Chamber Dimensions | 1120 × 800 × 1000 mm (L×W×H) |
| Antechamber Dimensions | Ø360 × 600 mm |
| Main Chamber Ultimate Vacuum | 0.5 torr |
| Antechamber Ultimate Vacuum | 0.05 torr |
| Maximum Positive Pressure | 1.1 atm |
| Inert Atmosphere Retention Time | >12 h |
| Glove Port Inner Diameter | Ø203 mm |
| Integrated Power Outlet | 1500 W, 3-pin, feedthrough-mounted |
| Vacuum Ports | 2 × KF25 + 3 × KF40 on main chamber rear wall |
| Antechamber Fittings | Vacuum gauge, ball valve, 1 × KF25 port |
| Certification | CE compliant |
| Weight | 360 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | VGB-6 |
| Pricing | Upon Request |
| Power Supply | AC 110–220 V, 50/60 Hz |
| Chamber Material | AISI 304 Stainless Steel |
| Internal Chamber Dimensions | 1220 × 760 × 900 mm (L×W×H) |
| Antechamber Configuration | Dual antechambers — large: Ø360 × 600 mm |
| small | 150 × 300 mm |
| Ambient Conditions | 20 °C, 1 atm |
| H₂O Level | <1 ppm (measured via GE 0–1000 ppm sensor, resolution 0.1 ppm) |
| O₂ Level | <1 ppm (measured via AII 0–1000 ppm sensor, resolution 0.1 ppm) |
| Working Gases | N₂, Ar, He |
| Purge/Control Gas | Compressed air or inert gas |
| Reduction Gas | Inert gas + H₂ mixture (H₂ concentration configurable) |
| Purification Media | BASF oxygen scavenger (Germany), UOP molecular sieve desiccant (USA) |
| Regeneration | Fully automated PLC-controlled cycle |
| Pressure Control | Siemens PLC + 6″ color touchscreen interface |
| Filtration | 0.3 µm particulate filters on both inlet and exhaust lines |
| Vacuum Pump | Edwards dual-stage rotary vane pump (8.4–12 m³/h) |
| Gloves | North Butyl rubber (USA), mounted on stainless steel flanges |
| Lighting | Philips fluorescent tubes |
| Overall Footprint | 2300 × 1500 × 1900 mm (L×W×H) |