Other Common Laboratory Equipment
Filter
Showing 1021–1050 of 1896 results
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Model | VTC-600-3HD |
| Target Configuration | 3 independent magnetron cathodes (2 × DC + 1 × RF) |
| Base Pressure | ≤5.0×10⁻³ Pa |
| Ultimate Vacuum | ≤5.0×10⁻⁴ Pa |
| Operating Pressure Range | 0.1–5 Pa |
| DC Power Supply | 2 units, 0–500 W each |
| RF Power Supply | 1 unit, 0–300 W, 13.56 MHz |
| Substrate Heater | RT to 500 °C, ±1 °C stability |
| Rotating Sample Stage | Ø132 mm, 1–20 rpm |
| Adjustable Target-to-Substrate Distance | 85–115 mm |
| Film Uniformity | ±5% over Ø100 mm substrate |
| Cooling | Integrated recirculating chiller (deionized water) |
| Gas Control | Dual-channel mass flow controllers (1–100 sccm & 1–200 sccm, Ar ≥99.999%) |
| Vacuum Chamber | Ø295 mm × 265 mm height |
| Pumping System | Pfeiffer Hipace 80 turbo-molecular pump (67 L/s) + MVP015-2DC diaphragm backing pump (1 m³/h) |
| Total Weight | 160 kg (excl. chiller) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | VTC-600-3HD-1000 |
| Input Power | 220 V / 50 Hz |
| Number of Sputtering Targets | 3 |
| Chamber Inner Diameter | Ø300 mm |
| Target Cooling | Water-Cooled |
| Ultimate Vacuum | 7.4 × 10⁻⁵ Pa |
| Vacuum Chamber Dimensions | Φ300 × 330 mm |
| Vacuum System | VRD-16 Rotary Vane Pump + FF-100/150 Turbo-Molecular Pump |
| Pump-Down Time | ≤30 min (from atmosphere to 5.0 × 10⁻³ Pa) |
| Gas Inlet System | Dual Mass Flow Controllers (Ar: 100 sccm + 200 sccm |
| Target Size | Φ2 inch (50.8 mm), thickness 0.1–5 mm |
| Substrate Holder | Φ70 mm, heated (RT to 1000 °C) |
| Overall Dimensions | 900 mm (W) × 650 mm (D) × 1100 mm (H) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VTC-600GC-AM |
| Vacuum Base Pressure | 6.0 × 10⁻⁵ Pa |
| Leak Rate | ≤0.5 Pa/h |
| Pump-Down Time (Atm → 5.0 × 10⁻³ Pa) | ~5 min |
| Vacuum System | Dual-stage (Mechanical Pump + Turbomolecular Pump) |
| Substrate Holder Diameter | φ140 mm |
| Substrate Temperature Range | Ambient to 500 °C (±1 °C control accuracy) |
| Substrate Rotation Speed | 5–20 rpm |
| Gas Inlet Channels | 2 (Mass Flow Controllers for Ar and N₂) |
| Target-to-Substrate Angle | 34° |
| Number of Target Positions | 3 (120° spacing, customizable) |
| Target Cooling | Water-cooled |
| Target Diameter | 2″ (φ50.8 mm), Thickness: 0.1–5 mm |
| Optional Features | RF Power Supply (for insulating targets), DC Power Supply (for conductive targets), Substrate Bias Module |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VTC-600GD |
| Vacuum Base Pressure | ≤8.0×10⁻⁵ Pa |
| Chamber Inner Diameter | Ø300 mm |
| Substrate Heater Temperature Range | RT–500 °C (±1 °C) |
| Max. Number of Sputter Targets | 4 |
| DC Sputtering Power | Up to 500 W (optional) |
| RF Sputtering Power | Up to 300 W |
| Substrate Holder Diameter | Ø140 mm |
| Substrate Rotation Speed | 1–20 rpm |
| Cooling Method | Water-cooled targets |
| Target Size | Ø2″ (50.8 mm), thickness 0.1–5 mm |
| Gas Inlet Control | Dual MFCs (100 SCCM + 200 SCCM) |
| Process Gases | Ar, N₂, or other inert gases |
| Total Power Consumption | <3.5 kW |
| Dimensions (Main Unit) | 850×760×660 mm |
| Overall Dimensions | 1300×660×1200 mm |
| Weight | 190 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WDW-100D |
| Maximum Test Load | 100 kN |
| Temperature Range (Furnace) | 200–1100 °C |
| Temperature Range (Environmental Chamber) | −70 to 300 °C |
| Control System | Windows-based Closed-Loop Servo Control |
| Accuracy Class | ISO 7500-1 Class 1 / Optional Class 0.5 |
| Load Measurement Range | 2–100% FS |
| Load Resolution | 20,000 counts |
| Displacement Resolution | 0.01 mm |
| Speed Range | 0.01–500 mm/min |
| Effective Tensile Space | 700 mm (customizable) |
| Test Width | 550 mm (customizable) |
| Gripping Options | Manual Lever or Hydraulic |
| Specimen Compatibility | Flat (0–21 mm), Round (Ø9–26 mm) |
| Furnace Uniformity | ≤±2 °C (200–600 °C), ≤±3 °C (600–900 °C), ≤±4 °C (900–1100 °C) |
| Chamber Stability | ±0.5 °C temperature fluctuation, ±2% RH humidity fluctuation |
| Power Supply | 380 V AC, 50 Hz, Grounded |
| Total Power Consumption | <10 kW (furnace), 5 kW (chamber) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Scientific Instrument |
| Model | WKYⅢ Series Single-Channel Adjustable-Volume Micropipette |
| Pricing | Available Upon Request |
| Volume Range | 0.1–10,000 µL (11 models) |
| Accuracy | ±0.3–4.1% (varies by volume range) |
| Precision (CV) | ≤0.3–2.5% (varies by volume range) |
| Increment | 0.1–100 µL (model-dependent) |
| Materials | ABS high-strength polymer body |
| Sealing System | Fluorosilicone rubber + PTFE |
| Spring Mechanism | Piano wire coil spring assembly |
| Tip Ejection Force | Optimized low-resistance design |
| Sterilization | Detachable lower shaft compatible with 70% ethanol immersion |
| Calibration | Field-adjustable micro-tuning mechanism |
| Ergonomics | Hook-equipped handle for vertical rack mounting |
| Tip Compatibility | ISO 8655-compliant universal conical tips |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XRF-S32 |
| Price | Upon Request |
| Power Supply | 220 V AC, 50/60 Hz, Single Phase |
| Dimensions (W×D×H) | 1000 × 800 × 1000 mm |
| Weight | 120 kg |
| Safety Certifications | CE, WEEE, EMC, RoHS (China), FCC (USA), ICES-001 (Canada) |
| Sample Capacity | 32 positions |
| Elemental Range | Ne (Z=10) to Pu (Z=94) |
| Detection Limit | Sub-ppm to ppm level (matrix-dependent) |
| Analysis Modes | Manual, Sequential Auto-Scan, Repetitive Batch |
| X-ray Source Interface | USB-connected handheld XRF spectrometer |
| Motion Control | Dual-axis (X-Y) precision stage with touchscreen HMI |
| Sample Form | Solid blocks or thin films |
| Atmospheric Correction | Real-time air attenuation & absorption compensation |
| Software | Integrated X-ray source control, detector acquisition, and spectral analysis suite supporting qualitative & quantitative analysis |
| Safety Features | Lead-glass viewing window, interlocked front door, status indicator lamp, remote operation capability |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YLJ-150TA |
| Power Supply | 220 V AC, 50/60 Hz |
| Maximum Pressure Capacity | 0–150 metric tons (1,471 kN) |
| Piston Diameter | φ250 mm (chromium-plated cylinder) |
| Cylinder Stroke | 50 mm |
| Hold Time Range | 0–999 seconds or minutes (user-selectable) |
| Pressure Calculation | Automatic conversion from applied force to sample-specific pressure (MPa or psi) based on entered die cavity diameter |
| Display | 4.3-inch TFT LCD touchscreen interface |
| Safety Enclosure | Reinforced steel frame with transparent polycarbonate safety door |
| Overall Dimensions (W×D×H) | 860 × 600 × 1100 mm |
| Net Weight | 680 kg |
| Key | Brand: KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Scientific Instrument |
| Model | YT-01 / YT-02 |
| Vacuum Chamber Area (YT-01 & YT-02) | 100 × 50 mm |
| Vacuum Ports | YT-01 — 2 lower + 2 upper |
| UV Wavelength | 365 nm |
| UV Power Output | 8 W |
| Max Sample Height Capacity | 15 mm |
| Max Applied Clamping Force | 3.5 kg |
| Compliance | Designed for ISO 13485-aligned histology workflows and GLP-compliant hard-tissue preparation |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YTP550-4E16A |
| Power | 550 W |
| Voltage/Frequency | 208–240 V, 50/60 Hz |
| Max Current | 3.6 A |
| Speed | 1400 rpm |
| Pumping Speed | 7.8 CFM (240 L/min) |
| Ultimate Pressure | 4 × 10⁻¹ Pa |
| Oil Capacity | 1100 mL |
| Operating Temperature Range | −5 °C to +60 °C |
| Vacuum Port | KF25 (ISO-KF) |
| Dimensions (L×W×H) | 440 × 160 × 300 mm |
| Weight | 25 kg |
| Optional Accessory | In-line Oil Mist Filter (KF25 compatible) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Model | ZDF-5201V01 |
| Measurement Range | 1.0×10⁵ to 1×10⁻⁸ Pa |
| Effective Range | 3×10³ to 5.0×10⁻⁸ Pa |
| Sensor Configuration | One Pirani (ZJ-52T) + One Hot-Cathode Ionization (ZJ-12) Gauge |
| Display | Dual 5-digit LED, scientific notation |
| Control Outputs | 4 relay channels (expandable to 6), AC220V/3A or DC28V/10A |
| Power Supply | AC 220 V ±10%, 50 Hz, 45 W |
| Dimensions (W×H×D) | 480 × 88 × 260 mm |
| Cutout | 440 × 80 mm |
| Weight | ~4 kg |
| Optional | RS-232/RS-485 interface, 0–5 V / 4–20 mA analog output, custom cable length (standard 5 m), PLC-compatible ionization control, multiple flange interfaces (KF/DN10–40, CF/DN16–35) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Model | ZDF-5214 |
| Measurement Range | 1.0×10⁵ to 1.0×10⁻⁷ Pa (full scale) |
| Effective Range | 3×10³ to 1×10⁻⁶ Pa |
| Reference Ranges | 1.0×10⁵–3×10³ Pa (resistive gauge) and 5×10⁻⁶–1×10⁻⁷ Pa (cold cathode ionization gauge) |
| Compatible Gauges | ZJ-52T (thermocouple/resistive), ZJ-14 (cold cathode) |
| Control Load Capacity | AC 220 V / 3 A or DC 28 V / 10 A |
| Power Supply | AC 220 V ±10 %, 50 Hz, 45 W |
| Dimensions (W×H×D) | 480 × 88 × 260 mm |
| Cutout Size | 440 × 80 mm |
| Weight | ~4 kg |
| Optional | 0–5 V / 4–20 mA analog output, RS-232/RS-485 interface, custom cable length (standard 5 m), multiple flange interfaces (KF/DN10–40, CF/DN16–35, glass/metal direct insertion) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZDF-5227 |
| Pricing | Available Upon Request |
| Measurement Principle | Combined Pirani (thermal conductivity) and Hot-Cathode Ionization (electron impact ionization) |
| Full Range | 1.0×10⁵ to 1×10⁻⁵ Pa |
| Effective Measurement Range | 3×10³ to 1×10⁻⁵ Pa |
| Reference Range (Pirani only) | 1.0×10⁵ to 3×10³ Pa |
| Compatible Gauges | ZJ-52T (Pirani), ZJ-27 (Hot-Cathode Ionization) |
| Sensor Channels | 2 independent measurement channels |
| Display | Dual 5-digit LED, scientific notation (e.g., 1.2E−1 = 1.2×10⁻¹ Pa) |
| Control Outputs | 4 relay channels (expandable to 6), AC220V/3A or DC28V/10A per channel |
| Control Modes | Setpoint (point) or band (region) control with power-loss memory |
| Analog Output Options | 0–5 V or 4–20 mA (optional) |
| Communication Interfaces | RS-232 / RS-485 (optional) |
| Gauge Cable Length | Standard 5 m (custom lengths available) |
| Gauge Flange Options | ZJ-52T — Glass, metal direct-insert, DN16/DN25/DN35 CF, DN10/DN16/DN25/DN40 KF |
| Operating Power | AC 220 V ±10 %, 50 Hz, 45 W |
| Net Weight | ~4 kg |
| Enclosure Dimensions | 480 mm (W) × 88 mm (H) × 260 mm (D) |
| Panel Cutout | 440 mm × 80 mm |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZDF-5227AZ |
| Pricing | Upon Request |
| Measurement Principle | Combined Pirani (thermal conductivity) and Hot-Cathode Ionization (electron impact ionization) |
| Full Range | 1.0×10⁵ to 1×10⁻⁵ Pa |
| Effective Range | 3×10³ to 1×10⁻⁵ Pa |
| Reference Range (Pirani only) | 1.0×10⁵ to 3×10³ Pa |
| Compatible Gauges | ZJ-52T (Pirani), ZJ-27 (Hot-Cathode Ionization) |
| Sensor Channels | 2 independent measurement channels |
| Display | Dual 5-digit LED displays with scientific notation (e.g., 1.2E−1 = 1.2×10⁻¹ Pa) |
| Control Outputs | 4 relay channels (expandable to 6), AC220V/3A or DC28V/10A per channel |
| Control Modes | Setpoint (point control) or band-based (region control) with power-loss memory |
| Analog Output | Optional 0–5 V DC |
| Communication | Optional RS-232 or RS-485 interface |
| Gauge Cable Length | Standard 5 m (custom lengths available) |
| Gauge Flange Options | ZJ-52T — glass envelope, metal direct-insert, DN16/DN25/DN35 CF, DN10/DN16/DN25/DN40 KF |
| Power Supply | AC 85–265 V, 50/60 Hz |
| Weight | ~1.5 kg |
| Enclosure Dimensions | 107 mm (W) × 129 mm (H) |
| Panel Cutout | 104 mm × 110 mm |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZDF-5227BZ |
| Pricing | Upon Request |
| Measurement Principle | Dual Pirani (ZJ-52T) + Hot Cathode Ionization (ZJ-27) |
| Range | 1.0×10⁵ to 1×10⁻⁵ Pa (effective: 3×10³ to 1×10⁻⁵ Pa) |
| Display | Triple 5-digit LED (scientific notation) |
| Control Outputs | 4 relay channels (expandable to 6) |
| Analog Output | 0–5 V (optional) |
| Communication | RS-232 / RS-485 (optional) |
| Power Supply | AC 85–265 V, 50/60 Hz, 15 W |
| Dimensions (H×W) | 129 mm × 107 mm |
| Cutout | 110 mm × 104 mm |
| Weight | ~1.5 kg |
| 规管 Compatibility | ZJ-52T (glass/metal/DN16–35 CF/DN10–40 KF) & ZJ-27 (glass/metal/DN16–35 CF/DN10–40 KF) |
| Gas Dependency | Pirani channels calibrated for N₂/air |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZDF-5227CX |
| Price | Upon Request |
| Measurement Range | 1.0×10⁵ to 1×10⁻⁵ Pa (Effective Range: 3×10³ to 1×10⁻⁵ Pa) |
| Compatible Gauges | ZJ-52T (thermocouple), ZJ-27 (Pirani) |
| Measurement Channels | 4 independent channels |
| Display | 4 five-digit LED windows with scientific notation (e.g., 1.2E−1 = 1.2×10⁻¹ Pa) |
| Control Outputs | 4 relay channels (expandable to 6) |
| Control Modes | Point control & zone control with power-loss memory |
| Relay Load Rating | AC 220 V / 3 A or DC 28 V / 10 A |
| Power Supply | AC 220 V ±10 %, 50 Hz, 45 W |
| Dimensions (W×H×D) | 480 × 88 × 260 mm |
| Cutout Size | 440 × 80 mm |
| Weight | ~4 kg |
| Analog Output Options | 0–5 V / 4–20 mA |
| Communication Interfaces | RS-232 / RS-485 |
| Gauge Cable Length | Standard 5 m (custom lengths available) |
| Gauge Flange Options | ZJ-52T/ZJ-27 compatible with glass, metal direct-insert, DN16/25/35 CF, DN10/16/25/40 KF |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZDK-5227 |
| Pricing | Available Upon Request |
| Measurement Range | 1.0×10⁵ to 1×10⁻⁵ Pa |
| Effective Range | 3×10³ to 1×10⁻⁵ Pa |
| Reference Range | 1.0×10⁵ to 3×10³ Pa |
| Compatible Gauges | ZJ-52T (thermocouple), ZJ-27 (cold cathode ionization) |
| Pressure Control Range | 1.0×10⁰ to 1.0×10⁻³ Pa |
| Control Stability | ±3% |
| Valve Type | TJF-1 Pneumatic Control Valve |
| Control Algorithm | PID |
| Response Time | <2 s |
| Measurement Channels | 3 (1 dedicated thermoresistive channel + 2 composite channels for thermocouple/ionization) |
| Display | Dual 5-digit LED, scientific notation (e.g., 1.2E−1 = 1.2×10⁻¹ Pa) |
| Control Outputs | 4 independent relay channels (expandable to 6) |
| Load Rating | AC 220 V / 3 A |
| Power Supply | AC 60–265 V, 50/60 Hz |
| Weight | ~4 kg |
| Enclosure Dimensions | 480 mm × 88 mm × 260 mm (W×H×D) |
| Panel Cutout | 440 mm × 80 mm |
| Optional Features | 0–5 V / 4–20 mA analog output, RS-232 / RS-485 serial interface, custom gauge cable length (standard: 5 m), multiple flange interfaces (CF DN16/DN25/DN35 |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZG |
| Pricing | Available Upon Request |
| Microwave Frequency | 2.45 GHz |
| Max Operating Temperature | 1150 °C (ZG1512/ZG3012) / 1600 °C (ZG1516/ZG3016) |
| Microwave Output Power Range | 0.01–1.40 kW (ZG15xx) / 0.01–2.80 kW (ZG30xx), continuously adjustable |
| Heating Chamber Dimensions | Ø40×130 mm or Ø60×120–130 mm (diameter × length) |
| Vacuum Level | ≤100 Pa (static) |
| Microwave Leakage | <0.05 mW/cm² (ZG1512/ZG3012) / <0.5 mW/cm² (ZG1516/ZG3016) |
| Temperature Measurement | Type S or B thermocouple (0–1300 °C or 0–1650 °C) / Infrared pyrometer (300–1800 °C) |
| Temperature Control Accuracy | ±0.1% of reading |
| Control System | Mitsubishi PLC + Schneider HMI touchscreen |
| Programmable Steps | 40-segment ramp-soak profile with data logging, export (CSV), real-time curve display, and dynamic screen saver |
| Atmosphere Compatibility | Oxidizing, inert, and mildly reducing gases via rapid pre-vacuum gas exchange |
| Safety Features | Interlocked door switch, over-temperature cutoff, magnetron overcurrent protection |
| External Dimensions (main unit) | ~530×430×380 mm (ZG15xx) / ~550×800×500 mm (ZG3016) |
| Stand Dimensions | ~900×500×700 mm (ZG15xx) / ~1000×600×800 mm (ZG3016) |
| Insulation | Multi-layer low-conductivity ceramic fiber architecture |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ZGS |
| Pricing | Upon Request |
| Voltage | 220±10 V / 380±10 V, 50 Hz |
| Rated Power | 4 kW / 5 kW |
| Microwave Output Power | 0.01–1.40 kW / 0.01–2.80 kW (continuously adjustable) |
| Microwave Frequency | 2.45 GHz |
| Max Operating Temperature | ≤1200 °C |
| Heating Zone Dimensions | Ø40×130 mm / Ø60×130 mm (diameter × length) |
| Temperature Measurement | Type K thermocouple, 0–1300 °C, accuracy ±0.1% of reading |
| Control System | Mitsubishi PLC + Schneider HMI touchscreen |
| Programmable Ramp/Soak Profiles | Up to 40 segments with data logging, export, real-time curve display, and dynamic screen-saver mode |
| Ultimate Static Vacuum | ≤100 Pa |
| Atmosphere Compatibility | Oxidizing, inert, and mildly reducing gases via rapid pre-vacuum gas exchange |
| Microwave Leakage | <0.05 mW/cm² (per IEC 61000-4-3 & GB/T 18317–2001) |
| Safety Interlocks | Door-closed confirmation switch, overtemperature protection, overcurrent protection |
| Main Unit Dimensions (L×W×H) | ~530×1000×1200 mm |
| Support Frame Dimensions (L×W×H) | ~900×1200×1500 mm |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJ-10B |
| Measurement Range | 6.5×10¹ – 1×10⁻⁴ Pa |
| X-ray Limit | 3×10⁻⁴ Pa |
| Sensitivity | 0.015 ±15% Pa⁻¹ |
| Accelerating Electrode Potential (vs. Ground) | 165 V |
| Cathode Potential (vs. Ground) | 50 V |
| Collector Potential (vs. Ground) | 0 V |
| Emission Current | 50 µA (1×10² – 1×10⁻² Pa), 500 µA (1×10⁻² – 1×10⁻⁴ Pa) |
| Max. Baking Temperature | 80 °C (glass/metal/KF flanges), 450 °C (CF flanges) |
| Vacuum Port Options | Φ15.5±0.5 mm glass, Φ15.5±0.1 mm metal, KF10/KF16/KF25/KF40, CF16/CF25/CF35 |
| Brand | KJ GROUP (Shenyang Kejing) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJ-12 |
| Measurement Range | 1×10⁻¹ – 1×10⁻⁸ Pa |
| Accelerating Electrode Potential | +200 V (vs. ground) |
| Cathode Potential | –50 V (vs. ground) |
| Collector Potential | 0 V (vs. ground) |
| Emission Current | 400 µA (1×10⁻¹ – 1×10⁻³ Pa), 4 mA (1×10⁻³ – 1×10⁻⁸ Pa) |
| Gauge Constant | 0.15 ±15% Pa⁻¹ |
| Degassing Method | Electron Bombardment (<30 W) |
| Maximum Bakeout Temperature | ≤400 °C |
| Flange Type | CF35 (ConFlat) |
| Reference-Only Range | 5×10⁻⁸ – 1×10⁻⁸ Pa |
| Brand | KJ GROUP (Shenyang Kejing) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJ-27 |
| Pricing | Available Upon Request |
| Measurement Principle | Hot Cathode Ionization (Bayard-Alpert Configuration) |
| Operating Range | 4×10¹ Pa to 1×10⁻⁵ Pa |
| X-Ray Limit | <1×10⁻⁶ Pa |
| Sensitivity | 0.15 ±15% Pa⁻¹ |
| Accelerator Voltage (vs. ground) | +225 V |
| Cathode Voltage (vs. ground) | +25 V |
| Collector Voltage (vs. ground) | 0 V |
| Emission Current | 100 µA (4×10¹–1×10⁻¹ Pa), 1 mA (1×10⁻¹–1×10⁻⁵ Pa) |
| Valid Measurement Ranges | 4×10¹–1×10⁻¹ Pa (primary) |
| Feedthrough Types & Max Bakeout Temp | Φ15.5±0.5 mm glass envelope (80 °C), Φ15.5±0.1 mm metal envelope (80 °C), KF10/KF16/KF25/KF40 (all ≤80 °C), CF16/CF25/CF35 (all ≤450 °C) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJ-52J |
| Pricing | Available Upon Request |
| Measurement Range | 1×10⁵ to 1×10⁻¹ Pa |
| Filament Material | Tungsten |
| Cold Filament Resistance | 86.5 ± 1.7 Ω at 23 ± 3 °C |
| Filament Operating Temperature | 40–300 °C |
| Accuracy (Scatter) | ≤ ±25% in 3×10³–1×10⁻¹ Pa range |
| Vacuum Port Options | Φ15.5±0.5 mm glass seal (max bakeout: 80 °C) |
| Φ15.5±0.1 mm metal seal (max bakeout | 80 °C) |
| KF10/KF16/KF25/KF40 quick-release flanges (max bakeout | 80 °C) |
| CF16/CF25/CF35 conflat flanges (max bakeout | 450 °C) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJ-52T |
| Pricing | Available Upon Request |
| Measurement Range | 1×10⁵ to 1×10⁻¹ Pa |
| Filament Material | Tungsten |
| Cold Filament Resistance | 86.5 ± 1.7 Ω at 23 ± 3 °C |
| Operating Filament Temperature | 40–300 °C |
| Zero Drift | ≤ ±25% (within 3×10³–1×10⁻¹ Pa) |
| Vacuum Port Options | Φ15.5±0.5 mm Glass Seal (max bakeout: 80 °C) |
| Φ15.5±0.1 mm Metal Seal (max bakeout | 80 °C) |
| KF10/KF16/KF25/KF40 Quick-Release Flanges (max bakeout | 80 °C) |
| CF16/CF25/CF35 Conflat Flanges (max bakeout | 450 °C) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJ-53B |
| Pricing | Available Upon Request |
| Measurement Range | 4×10²–1×10⁻¹ Pa |
| Heating Current | 28 ± 1.5 mA |
| Cold Filament Resistance | 9.5 ± 1 Ω @ 23 ± 3 °C |
| Filament Operating Temperature | 40–150 °C |
| Output Scatter | ≤ ±20 % |
| Vacuum Port | Φ15 ± 0.5 mm Glass Seal |
| Maximum Bakeout Temperature | 80 °C |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJ-54D |
| Pricing | Available Upon Request |
| Measurement Range | 3×10²–1×10⁻¹ Pa |
| Heating Current | 28 ± 1.5 mA |
| Cold Filament Resistance | 9.5 ± 1 Ω at 23 ± 3 °C |
| Filament Operating Temperature | 40–150 °C |
| Output Scatter (Zero Drift) | ≤ ±20 % |
| Vacuum Flange Options | Φ15±0.1 mm Metal Seal (Max Bakeout: 80 °C) |
| KF10–KF40 Quick-Release Flanges (Max Bakeout | 80 °C) |
| CF16–CF35 Conflat Flanges (Max Bakeout | 450 °C) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZK |
| Pricing | Available Upon Request |
| Microwave Frequency | 2.45 GHz |
| Max Operating Temperature (Atmosphere) | ≤1600 °C |
| Max Operating Temperature (Vacuum) | ≤1500 °C |
| Vacuum Level | ≤1×10⁻³ Pa |
| Microwave Power Range | 0.01–5.60 kW (continuous, stepless adjustment) |
| Heating Chamber Dimensions (ZK6016) | Φ180×150 mm |
| Temperature Measurement | Infrared Pyrometer (300–1800 °C, ±0.1% of reading) |
| Control System | Mitsubishi PLC + Schneider HMI Touchscreen |
| Programmable Stages | 40-segment ramp/soak profiles with data logging, export, real-time curve display, dynamic screen saver, and one-touch auto-vacuum initiation |
| Atmosphere Control | Dual-channel mass flow-controlled gas system (O₂, N₂, Ar, H₂, forming gas, etc.) |
| Cooling | Closed-loop recirculating chiller (2 m³/h flow rate, 5.2 kW cooling capacity) |
| Rotation Mechanism | Magnetic fluid rotary seal, 4–6 rpm |
| Microwave Leakage | <0.5 mW/cm² |
| Safety Interlocks | Door-closed sensor, overtemperature protection, overcurrent cutoff, coolant flow monitoring, magnetron fault alarm |
| Brand | KJ GROUP |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZWDL-900X |
| Rated Voltage | AC 380 V, 50/60 Hz |
| Rated Power | 50 kW |
| Maximum Operating Temperature | 1350 °C |
| Recommended Heating Rate | ≤5 °C/min |
| Temperature Uniformity | ±1 °C (at 1280 °C, steady state) |
| Heating Element | Silicon Carbide Rods (Φ30 mm × 1200 mm + 350 mm, delta-connected) |
| Chamber Dimensions | 1300 mm × 1200 mm × 1200 mm (W×D×H) |
| External Dimensions (Furnace Body) | 2100 mm × 2100 mm × 2300 mm |
| Control Cabinet Dimensions | 640 mm × 550 mm × 1600 mm |
| Net Weight | ~350 kg |
| Cooling System | Integrated Closed-Loop Chiller (deionized water or purified water) |
| Atmosphere Requirement | Argon (≥99.99% purity), supplied via external cylinder with 6 mm double-ferrule compression fitting |
| Ambient Requirements | Altitude ≤1000 m |
| Electrical Supply | 3-phase AC 380 V, 63 A circuit breaker with dedicated grounding |
| Minimum Circuit Breaker Rating | 250 A |
| Workbench Requirement | ≥1500 mm × 600 mm × 700 mm, load capacity ≥200 kg |
| Ventilation | Local exhaust ventilation required for inert gas purge management |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 833 |
| Pricing | Available Upon Request |
| Brand | Advantec |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Imported |
| Model | KDC2-D01 |
| Power Supply | Single-phase AC 100 V, 50/60 Hz |
| Dimensions (W×D×H) | 250 × 280 × 260 mm |
| Weight | 9 kg |
| Airflow Capacity | 1.3 m³/min |
| Maximum Static Pressure | 9.0 kPa |
| Hose Diameter | Φ50 mm (Φ38 mm optional) |
| Packaging Dimensions | 400 × 390 × 310 mm |
| Gross Weight | 10 kg |