| Key | Origin: USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 670 |
| Maximum Operating Pressure | 40 bar |
| Sample Chamber Dimensions | 10.2 cm (4 in) diameter × 17.8 cm (7 in) depth |
| Pressure Gauge | Analog dial, 40 bar range, ±0.5% full-scale accuracy, 11.4 cm (4.5 in) face diameter |
| Overall Dimensions | 33 × 28 × 24 cm |
| Weight | 7.5 kg |
| Included Accessories | Sealing gaskets (10 pcs, solid), O-ring lubricant, 3/16″ insertion tool, 1.83 m (6 ft) inflation hose, valve adjustment tool, technical manual |
| Optional Accessories | 22 ft³ aluminum high-pressure gas cylinder (4.4 kg), illuminated handheld magnifier, gasket set (1/16″, 1/8″, 3/16″, solid), aluminum-frame backpack (1.8 kg) |
| Key | Origin: USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 1000 |
| Quotation | Available Upon Request |
| Max Operating Pressure | 70 bar |
| Sample Chamber | Stainless Steel, 2.5 in (63.5 mm) diameter × 5 in (127 mm) depth |
| Pressure Gauge | Analog dial, 70 bar range, ±0.5% full-scale accuracy, 6 in (152 mm) face diameter |
| Dimensions (W×D×H) | 33 × 28 × 24 cm |
| Weight | 9.5 kg |
| Key | Origin: USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 610 |
| Price | Upon Request |
| Max Operating Pressure | 40 bar |
| Sample Chamber | Aluminum, 2.5 in (63.5 mm) diameter × 5 in (127 mm) depth |
| Pressure Gauge | Analog dial, 40 bar range, ±0.5% full-scale accuracy, 4.5 in (114 mm) face diameter |
| Dimensions (L×W×H) | 53 × 31 × 22 cm |
| Weight | 12.3 kg |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | RP-400 |
| Spectral Range (UVIS) | 380–780 nm |
| Spectral Range (NIR) | 640–1050 nm |
| Light Source | Pulsed Xenon Lamp (380–1050 nm) |
| Spectral Resolution (FWHM) | 8 nm |
| Stray Light Rejection | −30 dB |
| Display | 2.4″ Color TFT Touchscreen (240 × 320 px, 65,535 colors) |
| Memory | 32 MB Flash (≥8,000 measurements) |
| ADC | 16-bit |
| Dynamic Range | 1:4,300 (high gain), 1:13,000 (low gain) |
| Interface | USB 2.0 |
| Dimensions | 150 × 75 × 40 mm |
| Weight | 300 g |
| Enclosure | Splash-resistant IP54-rated housing |
| Power | Rechargeable Li-ion battery (USB charging) |
| Operating Time | Up to 48 h continuous measurement |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–70 °C |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PolyPen RP-410 |
| Spectral Range (UVIS) | 380–790 nm |
| Spectral Range (NIR) | 640–1050 nm |
| Spectral Resolution (FWHM) | 8 nm |
| Stray Light | –30 dB |
| Optical Aperture | 7 mm |
| Scan Time | ~100 ms |
| Display | 240 × 320 pixel color touchscreen (65,535 colors) |
| Memory | 32 MB (≥8,000 spectra) |
| ADC | 16-bit |
| Dynamic Range | 1:4,300 (high gain), 1:13,000 (low gain) |
| GPS | Integrated |
| Connectivity | USB + Bluetooth |
| Power | Rechargeable Li-ion battery |
| Battery Life | Up to 48 h continuous operation |
| Dimensions | 150 × 75 × 40 mm |
| Weight | 300 g |
| Enclosure | Splash-resistant housing |
| Operating Temperature | 0–50 °C |
| Storage Temperature | –20–70 °C |
| Calibration Standard (optional) | >99% Lambertian reflectance, UV–VIS–NIR flat-field (±1%) |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | DMS-600 |
| Temperature Accuracy | ±0.3 °C |
| Relative Humidity Accuracy | ±3 % RH |
| Operating Temperature Range | −40 °C to +80 °C |
| Spectral Channels | 18 |
| Center Wavelengths (nm) | 410, 435, 460, 485, 510, 535, 560, 585, 610, 645, 680, 705, 730, 760, 810, 860, 900, 940 |
| Bandwidth | 20 nm per channel |
| Field of View | 41° |
| Optical Sensor Type | Diffuse irradiance (cosine-corrected) |
| Number of Spectral Sensor Units | 3 |
| Power Supply | Rechargeable Li-polymer battery (5000 mAh) |
| Operating Current | 80 mA |
| Sleep Current | 180 μA |
| Weight | 600 g |
| Data Transmission | NB-IoT |
| Remote Access | Web-based cloud platform and dedicated mobile application |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | IPS-1000 |
| CO₂ Range | 0–3000 ppmv |
| δ¹³C Precision | <0.2 ‰ @ 1 s, 0.03 ‰ @ 60 s |
| δ¹⁸O Precision | <0.2 ‰ @ 1 s, 0.03 ‰ @ 60 s |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PlantCam |
| Pricing | Available Upon Request |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | RhizoScan |
| Price Range | USD 42,000 – 70,000 |
| Scanning Angle | 360° Full-Circle |
| Optical Resolution | 1200 DPI |
| Max Scan Width | 212 mm |
| Image Color Depth | True Color (24-bit) |
| Onboard Storage | 32 GB microSD |
| Scan Time per Rotation | ~20 s |
| Wireless Connectivity | Integrated Wi-Fi 802.11n |
| Power Supply | Rechargeable Lithium-ion Battery (6200 mAh) |
| Operational Runtime | Up to 12 h per full charge |
| Scanner Body Diameter | 47 mm or 62 mm |
| Compatible Minirhizotron Tube Dimensions | OD/ID = 55/49 mm or 70/64 mm |
| Tube Length | Customizable |
| Software Interface | Web-based (HTML5), compatible with iOS, Android, Windows, and macOS browsers |
| Data Export Formats | JPEG, TIFF, CSV (root metrics) |
| Root Parameter Quantification | Total root length, surface area, tip count, diameter class distribution, live/dead root discrimination |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | RhizoScan Plus |
| Scanning Angle | 360° Full-Circle |
| Optical Resolution | 1200 DPI |
| Max. Scan Width | 212 mm |
| Dual Illumination | White Light + UV (365 nm) |
| Image Output | Simultaneous Color RGB + UV-Induced Fluorescence |
| Storage | 32 GB MicroSD Card (Removable) |
| Scan Time per Rotation | ~20 s |
| Wireless Connectivity | Integrated Wi-Fi 802.11n (AP Mode) |
| Power Supply | Rechargeable Lithium-ion Battery (6200 mAh) |
| Scanner Head Diameter | 47 mm or 62 mm |
| Compatible Minirhizotron Tube Dimensions | OD/ID = 55/49 mm or 70/64 mm |
| Guidance System | Dual Precision Guide Wheels (Non-Scuffing) |
| Remote Control | Web-Based Interface via Smartphone, Tablet, or Laptop (No Cables or Dedicated Software Required) |
| Deployment Modes | Portable Handheld or In Situ Automated (Timer-Triggered Acquisition, Customizable) |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | AlgaeTron AG160 / AG300 |
| Capacity | 163 L (AG160) / 307 L (AG300) |
| Temperature Range | 10–45 °C |
| Illumination | White + 735 nm Far-Red LEDs |
| Max Photosynthetic Photon Flux Density (PPFD) | 1500 µmol/m²·s (top, upgradable) / 500 µmol/m²·s (lower, upgradable) |
| Illumination Layers | 2 (AG160) / 4 (AG300) |
| Total Cultivation Area | 0.38 m² (AG160) / 0.75 m² (AG300) |
| Internal Dimensions | 51 × 45 × 71 cm (AG160) / 51 × 45 × 135 cm (AG300) |
| External Dimensions | 60 × 62 × 114 cm (AG160) / 60 × 62 × 177 cm (AG300) |
| Airflow | 150 L/h |
| Refrigerant | R290 |
| Display | 7″ color LCD touchscreen |
| Programmable Protocols | Up to 100 user-defined sequences including diel cycles, dynamic light gradients, and rapid light fluctuations |
| Brand | PSI (Czech Republic) |
|---|---|
| Model | AquaPen AP110 |
| Probe Types | AP110-C (cuvette-based) & AP110-P (immersion probe) |
| Excitation Wavelengths | 455 nm (blue), 620 nm (red) for fluorescence |
| Detection Limit | 0.5 µg Chl/L |
| Time Resolution | 10 µs (100,000 measurements/s) for OJIP kinetics |
| Data Storage | 16 MB (~149,000 data points) |
| Dimensions | 165 × 65 × 55 mm |
| Weight | 290 g |
| Operating Temperature | 0–55 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Power | Rechargeable Li-ion battery, 48 h continuous operation |
| Communication | Bluetooth + USB + integrated GPS |
| Software | FluorPen v1.1 (Windows 7+) |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | FKM |
| Price Range | USD 68,000 – 136,000 |
| Excitation Light Sources | IR, Red, Orange, Blue, Green, White, UV, Far-Red |
| Spectral Range (SM9000 Spectrometer) | 200–980 nm |
| Wavelength Accuracy | <0.5 nm |
| CCD Resolution | 1360 × 1024 pixels |
| Frame Rate | up to 20 fps at full resolution |
| A/D Depth | 16-bit (65,536 gray levels) |
| Temperature Control Range | 5–70 °C (±0.1 °C) |
| Objective Lenses | 10×, 20×, 40×, 63×, 100× fluorescence-grade |
| Filter Wheel | 6-position, configurable for Chl a, GFP/SYTOX, DAPI/CTC, etc. |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | FL6000 |
| Time Resolution | 4 µs (standard), 1 µs (high-speed option) |
| Detection Limit | 1 µg Chl a/L |
| Excitation Wavelengths | 455 nm (blue), 617 nm & 630 nm (red/orange), optional 735 nm (far-red) |
| Measurement Chamber | 4 mL cuvette, 10×10 mm base |
| AD Converter | 500 kHz / 16-bit |
| Software | FluorWin v5.x |
| Compliance | ASTM E2912-22 (Fluorescence Instrumentation), ISO 10265:2021 (Photosynthetic Performance Testing), GLP-ready audit trail support |
| Brand | PSI (Photosynthesis Systems Instruments) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Closed-Box |
| Imaging Area | 13 × 13 cm |
| CCD Sensor | TOMI-2, 1360 × 1024 px, 16-bit A/D, 20 fps max |
| LED Excitation Sources | 4 high-stability LED panels (standard: 2 red-orange + 2 white) |
| Fluorescence Parameters | >50 quantitative parameters including Fo, Fm, Fv/Fm, Y(II), NPQ, qP, qL, Rfd, ETR, OJIP-derived indices (e.g., PIabs, Vj), QA-reoxidation kinetics, PAR absorption & NDVI (optional modules) |
| Software | FluorCam v8.x with protocol editor, time-stamped automated acquisition, GLP-compliant data logging, export to CSV/HDF5 |
| Compliance | Designed for ISO/IEC 17025-aligned plant phenotyping labs |
| Dimensions | 472 × 479 × 513 mm (W×D×H) |
| Weight | 35 kg |
| Power | 88–264 V AC, 240–300 W |
| Brand | PSI (Photosynthesis Systems Instruments) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Closed-System |
| Imaging Area | 13 × 13 cm |
| Sensor | TOMI-2 high-resolution CCD (1360 × 1024 px, 16-bit A/D, 20 fps max) |
| Light Sources | 4 LED panels (2 × red-orange, 2 × blue) |
| Filter Wheel | 7-position motorized, software-controlled with Chl *a* and GFP filter sets |
| Fluorescence Parameters | >50 chlorophyll fluorescence parameters (Fo, Fm, Fv/Fm, NPQ, qP, ETR, Y(NO), Y(NPQ), Rfd, etc.), all exportable as spatially resolved false-color images |
| Optional Modules | OJIP fast kinetics imaging, QA⁻ reoxidation kinetics, PAR absorption & NDVI imaging, temperature-controlled sample stage (15–75 °C) |
| Software | FluorCam v8.x with protocol editor, time-stamped automated acquisition, GLP-compliant data logging, and multi-parameter image overlay |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam FC 00-C/1010GFP |
| Imaging Area | 13 × 13 cm uniform LED illumination |
| Camera Resolution | 1392 × 1040 pixels (optional: 640 × 480 or 512 × 512) |
| Temporal Resolution | up to 1 µs for fast fluorescence induction kinetics |
| Filter Wheel | motorized 8-position |
| Excitation Wavelengths | 384 nm (BFP), 395–397 nm (wtGFP), 488 nm (EGFP), customizable LED arrays |
| Emission Detection | configurable bandpass filters (e.g., 469/35 nm, 532/28 nm) |
| Software | FluorCam v7.x with automated dark adaptation, ROI-based kinetics, GLP-compliant audit trail, Excel export, barcode support |
| Compliance | Compatible with ASTM E2595-22 (fluorescence imaging standards), supports 21 CFR Part 11–compliant user access control and data integrity workflows |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Large-Scale Plant Chlorophyll Fluorescence and Multispectral Imaging Platform |
| Imaging Area | 35 × 35 cm |
| CCD Resolution | 1360 × 1024 pixels |
| Frame Rate | up to 20 fps at full resolution |
| A/D Depth | 16-bit (65,536 gray levels) |
| Pixel Size | 6.45 µm × 6.45 µm |
| Excitation Wavelengths | 320–400 nm (UV-A), 450 nm (blue), 620 nm (red), white light, 735 nm (NIR) |
| Filter Wheel | 7-position motorized |
| Adjustable Imaging Height | 350–1350 mm |
| Compliance | ASTM E2912, ISO 17025-compatible workflow support, GLP/GMP-ready data audit trail (via software timestamping and protocol versioning) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Large-Scale Version |
| Imaging Area | 35 × 35 cm |
| CCD Resolution | 1360 × 1024 pixels |
| Frame Rate | up to 20 fps at full resolution |
| A/D Depth | 16-bit (65,536 gray levels) |
| Pixel Size | 6.45 µm × 6.45 µm |
| Adjustable Platform Height | 350–1350 mm |
| Excitation Sources | 620 nm red, dual-color (620 nm + cool white), optional blue/UV/IR LEDs |
| Filter Wheel | 7-position motorized |
| Standard Fluorescence Parameters | >50 chlorophyll fluorescence parameters (e.g., Fv/Fm, ΦPSII, NPQ, qP, Rfd) |
| Optional Modules | UV-induced multispectral fluorescence (F440, F520, F690, F740), GFP/YFP imaging, PAR absorption & NDVI imaging, IR thermography (640 × 512, -25 to +150 °C, 30 mK sensitivity) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Mobile |
| Imaging Area | 35 × 35 cm |
| Adjustable Height Range | 20–150 cm |
| CCD Sensor | 2/3″, 1392 × 1040 pixels (15 fps), pixel size 6.45 µm |
| Excitation Sources | Orange, white & NIR LEDs (72 × 72 cm panel, 3 × 64 LEDs) |
| Actinic Lights | Dual-color, 350 & 550 µmol photons·m⁻²·s⁻¹ |
| Saturation Pulse | Up to 3500 µmol photons·m⁻²·s⁻¹ |
| Fluorescence Parameters | >50 including F₀, Fₘ, Fᵥ/Fₘ, NPQ, QY, Rfd, qP, qN, ΦPSII, etc. |
| Data Acquisition | Time-stamped automated protocols, USB 2.0 (480 Mbit/s) |
| Power Supply | 380 V three-phase AC or optional DC generator unit |
| IP Rating | Optional waterproof housing for field use |
| Dimensions | 192 × 125 × 100 cm (H × W × D) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Mobile |
| Imaging Sensor | 1392×1040 CCD, 20 fps, 6.45 µm pixel size |
| Excitation Sources | 4+1 configurable LED array (red, cool white, UV 320–400 nm), optional blue/green/cyan/FAR LEDs |
| Filter Wheel | 7-position motorized, with Chl-F, MCF, GFP/YFP, F440/F520/F690/F740 filters |
| Fluorescence Parameters | >60 quantitative metrics including Fo, Fm, Fv/Fm, NPQ, QY, PARabs, Rfd, BGF, UV-Chl-F ratios |
| NDVI & PAR Absorption | Optional dual-wavelength (630/735 nm) LED module |
| Thermal Imaging (optional) | Uncooled VOx microbolometer, 640×512 pixels, 7.5–13.5 µm, -25 to 150 °C, sensitivity ≤30 mK @ 30 °C |
| RGB Imaging (optional) | 2592×1944 scientific-grade CMOS, 54 dB SNR, 1–40× zoom |
| Power Supply | 90–240 V AC |
| Compliance | CE-marked, ISO/IEC 17025-compatible data acquisition architecture, FDA 21 CFR Part 11-ready software audit trail (with optional configuration) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Open-Field Multispectral Fluorescence Imaging System |
| Imaging Area | 13 × 13 cm (Standard), 20 × 20 cm (Large Format) |
| CCD Resolution | 1392 × 1040 pixels, Pixel Size: 6.45 µm |
| Excitation Wavelengths | UV (320–400 nm), Blue (450 nm), Red (618 nm), Far-Red (735 nm), Green (530 nm), Cyan (490 nm) |
| Emission Detection Bands | F440, F520, F690, F740, GFP (509 nm), YFP (527 nm), Chl-F, BGF, PARabs, NDVI |
| Actinic Light Intensity | Up to 3000 µmol·m⁻²·s⁻¹ (configurable) |
| Saturation Flash | Up to 6000 µmol·m⁻²·s⁻¹ |
| Measurement Pulse Duration | 10–100 µs |
| Filter Wheel | 7-position motorized |
| Software | FluorCam v8.x with GLP-compliant audit trail, protocol editor, ROI-based quantification, dual averaging modes (signal-then-average / average-then-signal), time-stamped automated acquisition |
| Compliance | Designed for ISO/IEC 17025-aligned labs |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Portable |
| Imaging Area | 40 mm × 40 mm |
| Sensor | TOMI-2 CCD, 1360 × 1024 pixels, 16-bit A/D, 20 fps @ full resolution |
| Excitation Light | 610–620 nm (measuring light), 5300 K white light (actinic & saturating light, up to 4500 µmol photons/m²·s), 710–740 nm far-red LEDs (for Fo′ determination) |
| Spectral Detection Range | 400–1000 nm |
| Weight | 2 kg |
| Dimensions | 194 × 182 × 280 mm |
| Power Supply | AC 100–240 V or optional field battery pack (≥10 h operation) |
| Operating Conditions | 5–40 °C, 0–90% RH (non-condensing) |
| Compliance | CE, RoHS, firmware-upgradable BIOS |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Portable |
| CO₂ Range | 0–3000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Leaf Chamber Temp | −5 to 50 °C (±0.2 °C) |
| Air Pump Flow | 100–500 mL/min |
| CO₂ Control | up to 2000 ppm |
| PAR Control | RGB LED up to 2400 µmol·m⁻²·s⁻¹, White LED up to 2500 µmol·m⁻²·s⁻¹ |
| Battery Life | up to 16 h (12 V / 7.5 Ah Li-ion) |
| Imaging Sensor | TOMI-2 CCD, 1360×1024 pixels, 16-bit A/D, 20 fps max |
| Imaging Area | 35×46 mm |
| Excitation Wavelengths | 620 nm (measuring light), 455/620/white (saturating & actinic light), 735 nm (far-red) |
| Spectral Response | 400–1000 nm |
| Quantum Efficiency | 70% at 540 nm |
| Read Noise | <12 e⁻ RMS |
| Full Well Capacity | >70,000 e⁻ (unbinned) |
| Data Interface | Gigabit Ethernet, Mini-B USB, RS232 |
| Display | 480×272 pixel WQVGA touchscreen |
| Storage | SD card (up to 32 GB) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam-96 |
| Measurement Principle | Dual-modality chlorophyll fluorescence imaging + fiber-optic dissolved oxygen sensing |
| Throughput | 96 parallel samples |
| Fluorescence Parameters | >50 including Fo, Fm, Fv/Fm, ΦPSII, NPQ, qL, ETR, Rfd, QY_Ln |
| Oxygen Measurement | Fiber-optic sensor, ±0.1% O₂ @ 1% O₂, 0.01% O₂ resolution, 10–20 Hz sampling rate |
| Chamber Material | Sterilizable transparent polystyrene |
| Dimensions (O₂ module) | 162 × 102 × 32 mm |
| Weight (O₂ module) | 670 g |
| Temperature Sensor | 0–50 °C, ±0.5 °C accuracy, 0.012 °C resolution |
| Pressure Sensor | 300–1100 mbar, ±6 mbar accuracy, 0.11 mbar resolution |
| Software | FluorCam v7.x with GLP-compliant audit trail, protocol editor, ROI-based kinetic analysis, signal averaging mode for low-biomass samples |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam-MultiSpectral Modular Plant Phenotyping Imaging System |
| Thermal Imager | Uncooled VOx microbolometer, 640×512 px, 7.5–13.5 µm, −25 to +150 °C, NETD ≤ 0.03 °C @ 30 °C |
| Fluorescence Imaging | UV/Blue/Red excitation, F440/F520/F690/F740 detection, 1360×1024 CCD, 20 fps |
| RGB Imaging | 2592×1944 sensor, 1–40× zoom, FOV 6.1×7.9 mm (40×) to 20.8×25.4 mm |
| NDVI/PAR Module | 630 nm & 740 nm LEDs |
| Max Sample Height | 50 cm |
| Compliance | CE-marked, ISO/IEC 17025 traceable calibration documentation available |
| Software | FluorCam v7.x with GLP-compliant audit trail, FDA 21 CFR Part 11 optional modules |
| Brand | PSI (Photosynthesis Systems Instruments, Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorPen FP110 |
| Measurement Principle | Pulse-Amplitude-Modulated (PAM) chlorophyll fluorescence kinetics |
| Light Source | 470 nm blue LED (wavelength-selectable option available) |
| Detection | PIN photodiode with 667–750 nm bandpass filter |
| Time Resolution | 10 µs (100,000 measurements/s) |
| Fluorescence Parameters | >50 including F₀, Fₘ, Fᵥ/Fₘ, ΦPSII, NPQ, qP, Rfd, PI_ABS, ABS/RC, TR₀/RC, ETo/RC, DI₀/RC, Mo, Area, Sm, OJIP-derived 26 parameters |
| Excitation Intensities | Measuring light (0.09–0.9 µmol photons·m⁻²·s⁻¹), Actinic light (10–1000 µmol photons·m⁻²·s⁻¹), Saturating pulse (up to 3000 µmol photons·m⁻²·s⁻¹) |
| PAR Sensor (optional) | 400–700 nm, cosine-corrected, ±5% accuracy, output in µmol photons·m⁻²·s⁻¹ |
| Sample Interface | Interchangeable leaf clips (FP110/S fixed, FP110/D split, FP110/P fiber-optic probe, FP110/X custom) |
| Data Storage | 16 MB flash memory (~149,000 data points) |
| Display | Graphical LCD, dual-button interface |
| Power | Rechargeable Li-ion battery, 48 h continuous operation, USB charging |
| Environmental Rating | 0–55 °C, 0–95% RH (non-condensing) |
| Connectivity | Integrated Bluetooth 4.0 + USB 2.0 + GPS module |
| Software | FluorPen 1.1 (Windows 7+), supports data download, kinetic curve visualization, Excel export, remote instrument control, and GLP-compliant audit trail generation |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Fyto-A2/A3/B2/B3/C/MULTI Series |
| Light Source Type | Programmable Multi-Spectral LED Array |
| Active Area Options | 27 × 81 cm or 27 × 41 cm |
| Spectral Channels | Cool White (5000–6500 K), Deep Red (660 nm), Far-Red (735 nm), plus optional Blue (450 nm), Green (530 nm), IR (850 nm) |
| Photon Flux Density | Up to 1600 µmol(photon)·m⁻²·s⁻¹ (at 50 cm, MULTI configuration) |
| Intensity Control Range | 0–100% in 0.1% increments |
| Uniformity | ±5% across active area (measured per ASTM E2917-20) |
| LED Lifetime | 60,000–70,000 h at rated output |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–80% RH (non-condensing) |
| Control Interface | RS-485, USB, Ethernet (Light Studio v4.85) |
| Compliance | CE, RoHS, IEC 61000-6-3 (EMI), IEC 61000-6-2 (Immunity) |
| Software Features | Predefined diurnal cycles, cloud simulation, pulse modulation (µs–h), multi-channel spectral blending, GLP-compliant audit trail (optional) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Fyto-Panel |
| Dimensions | 27 × 81 cm or 27 × 41 cm |
| Maximum Photosynthetic Photon Flux Density (PPFD) | 2400 µmol·m⁻²·s⁻¹ at 50 cm |
| Spectral Channels | Cool White + Far-Red + Deep Red (standard) |
| LED Lifetime | 60,000–70,000 h |
| Power Consumption | 210 W (A), 360 W (B), 580 W (C), 600 W (MULTI) |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–80% RH (non-condensing) |
| Control Interface | USB/RS-485 |
| Software Features | Programmable light regimes (duration, intensity, spectral composition, modulation waveforms), cloud cover simulation, dawn/dusk transition modeling, GLP-compliant audit trail (via Light Studio Pro) |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | FytoScope |
| External Dimensions | 8.6 × 4.3 × 2.78 m (L×W×H) |
| Internal Dimensions | 8.00 × 3.50 × 2.20 m |
| Growing Area | 18 m² |
| Corridor Width | 75 cm |
| Temperature Range | 10–40 °C (±0.2 °C stability) |
| Humidity Range | 40–80 % RH |
| CO₂ Control (optional) | 250–5000 ppm (±2 % accuracy) |
| Light Intensity | 0–1000 µmol/m²/s at 50 cm |
| Spectral Channels | Tunable white + far-red LED arrays |
| Independent Zoning | 4 controllable growth zones |
| Air Filtration | EN779 G4 + G7 dual-stage |
| Thermal Insulation | Polyurethane foam, λ = 0.025 W/m·K |
| Control Interface | Integrated touchscreen + Fytotron software suite (server/client architecture) |
| Data Export | USB, LAN, real-time charting & audit-trail logging |