Empowering Scientific Discovery

Qingdi Quantum Scientific Instruments (Beijing) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLake Shore
OriginUSA
Model336
Sensor Inputs4 (expandable to 8 with Scan Option)
Control Outputs4 (2 high-power, 2 low-power)
Max Heating Power150 W (100 W + 50 W)
Temperature Range0.3 K to 1505 K
PID ControlDigital, Auto-Tuning & Zone-Based
Supported SensorsDiodes, RTDs (Pt100, Pt1000, Carbon-Glass, Cernox®, Rox™), Thermocouples (DT-470, DT-670, E, K, T, AuFe/Cr), Capacitance (with option card)
InterfaceEthernet, USB, IEEE-488 (GPIB)
Analog Output±10 V, 16-bit, 0.3 mV RMS noise
Display240 × 64 pixel graphical LCD
ComplianceGLP/GMP-ready architecture, supports audit trail via software logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLake Shore
OriginUSA
Model350
Input Channels4 (expandable to 8 with Scan Option)
Sensor CompatibilityCernox®, Rox™, DT-470, DT-670, PT-100/1000, carbon-glass, germanium, silicon diodes, thermocouples (with option cards), capacitive sensors
Measurement Range10 mK to 1000 K (sensor-dependent)
Excitation CurrentAs low as 10 nA for Cernox®
Noise PerformanceUltra-low-noise input circuitry optimized for ≤100 mK operation
Control Outputs4 independent PID-controlled outputs — Output 1: 75 W (25 Ω load), Output 2: 1 W (100 Ω load), Outputs 3 & 4: ±10 V analog (1 W max, 100 mA)
PID Auto-tuningPer-loop, real-time adjustment
Current ReversalEliminates thermoelectric offset in resistive sensors
ComplianceCE certified
InterfaceRS-232, USB, Ethernet (LXI-compliant)
Display240 × 64 pixel graphical LCD (8 × 40 characters), LED backlit
Data LoggingLocal buffer + remote streaming at up to 10 Hz per active channel
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLake Shore
OriginUSA
Model335
Temperature Range0.3 K to 1505 K
Sensor Inputs2 standard (expandable to 4 with optional thermocouple card)
Control Outputs2 independent PID channels
Heater Power75 W total (configurable as 50 W + 25 W or 75 W + 1 W)
InterfaceEthernet, USB, IEEE-488 (GPIB)
Analog Output±10 V
ComplianceGLP/GMP-ready with audit-trail-capable logging via software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandINTERHERENCE
OriginGermany
ModelVAHEAT
Temperature RangeRT–200 °C
Temperature Stability±0.01 °C (RMS)
Power ConsumptionStandard Version < 2500 mW
Heating RateUp to 100 °C/s (local), 40 °C/s (in liquid)
Compatible Microscopy ModesWidefield, Confocal, TIRF, iSCAT, STED, SIM, PALM, STORM, PAINT, AFM