- All
- Favorite
- Popular
- Most rated
| Key | Brand: Thermal Technology |
|---|---|
| Origin | USA |
| Model | Model 1000 |
| Type | Tube Furnace |
| Max Temperature | 3000 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Max Power | 3000 W |
| Heating Rate to Max Temp | 100 °C/min |
| Heating Zone Material | Graphite or Molybdenum |
| Internal Chamber Dimensions | 30 × 20 × 20 cm |
| Atmosphere Options | Vacuum (mechanical pump standard, high-vacuum optional), Ar, N₂, O₂, H₂ |
| Compliance | ASTM E2550, ISO 8573-1 (for gas purity control), GLP-compliant operation architecture |
| Brand | Thermal Technology |
|---|---|
| Origin | USA |
| Model | HP200 |
| Type | Graphite/W-Mo Heating Crucible-Type Hot Press Furnace |
| Max Temperature | 2500 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Max Power | 3000 W |
| Ramp Time to Max Temp | 30 min |
| Heating Elements | Graphite, Tungsten, Molybdenum |
| Internal Chamber Dimensions | 30 cm × 20 cm × 20 cm |
| Maximum Applied Pressure | 100 tons |
| Effective Hot Zone | 24″ × 24″ × 30″ (610 mm × 610 mm × 762 mm) |
| Brand | Thermal Technology |
|---|---|
| Origin | USA |
| Type | Horizontal/Vertical Tube Furnace |
| Max Temperature | 2500°C |
| Temperature Uniformity | ±1°C (at 2500°C, full hot zone) |
| Control Accuracy | ±0.1°C |
| Ramp Rate (to max temp) | >100°C/min |
| Cool-down Rate | up to 300°C/min |
| Heating Element | Tungsten Rods |
| Power Rating | 3000 W |
| Atmosphere Options | Vacuum (≤10⁻⁶ Torr), H₂ (wet/dry), NH₃ (dissociated), N₂, Ar, forming gas |
| Chamber Design | Cold-wall, double-jacketed stainless steel |
| Heating Zone Configuration | Multi-layer radiation shields with Mo/W reflective shielding |
| Programmable Controller | Microprocessor-based, 50+ stored recipes, real-time edit capability, alarm logging, RS-485/Ethernet interface |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermal Technology |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BJ5 |
| Instrument Type | Crucible-Type Arc Melting Furnace |
| Maximum Temperature | >3000 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Power Supply Requirement | 1000 A DC |
| Heating Rate to Max Temperature | ≤20 min |
| Heating Method | Thoriated Tungsten Electrode Arc Discharge |
| Internal Chamber Dimensions | 23 cm (W) × 24 cm (D) × 29 cm (H) |
| Electrode Diameter | 6.4 mm |
| Water-Cooled Stainless Steel Bell Jar Diameter | 24.4 cm, Height: 29.2 cm |
| Copper Hearth Diameter | 22.9 cm |
| Vacuum Range | 10⁻⁶ Torr (with optional turbomolecular pump) |
| Operating Pressure Range | High vacuum to slight positive pressure (≤1.5 bar gauge) |
| Viewing Port | Quartz window integrated in bell jar top |
| Sample Diameter Range | 13–76 mm |
| System Weight (main unit only) | 20.4 kg |
| Required Cooling Water | 30.4 L/min @ 3.5 bar, 21 °C |
| Vacuum Pump Requirement | ≥56.6 L/min (2 CFM) |
| Inert Gas Flow Range | 56.6–283.2 L/min (2–10 CFM) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Infinite Helium |
| Pricing | Upon Request |
| Brand | Depths of the Earth |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Equipment Type | Tube Furnace |
| Max Temperature | 1800 °C |
| Temperature Control Accuracy | ±2 °C |
| Voltage/Current Rating | 220–240 V, 20 A |
| Ramp Rate to Max Temp | 100 °C/min |
| Heating Method | Electrical Resistance Heating |
| Internal Chamber Dimensions | 120 × 60 × 60 cm |
| Pressure Range | 0.3–4.0 GPa |
| Pressure Control Precision | ±0.03 GPa |
| Temperature Gradient | ±15 °C |
| Quench Rate | up to 300 °C/s |
| Sample Volume Capacity | 90 mm³ (at 4.0 GPa, 10 mm die), 150 mm³ (at 2.5 GPa, 13 mm die), 500 mm³ (at 1.0 GPa, 19 mm die) |
| Continuous Operation Duration | Minutes to Months |
| Cooling System | Integrated Water-Cooled Jacket |
| Thermocouple Compatibility | Type B, J, E, T, L, N, K, W5Re–W26Re, Pt–Pt10Rh, Pt–Pt13Rh |
| Safety Features | Overtemperature, overvoltage, overcurrent, and coolant flow failure interlocks |
Show next