| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DZ-STA 200 |
| Heating Rate | 1–80 °C/min |
| Temperature Range | Ambient to 1150 °C (extendable to 1350 °C) |
| Temperature Stability | ±0.1 °C |
| Max Sample Weight | 5 g |
| Atmosphere Compatibility | Inert, Oxidizing, Reducing |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ-STA 300 |
| Temperature Range | Ambient to 1550 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| TG Sensitivity | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Data Interface | USB |
| Display | 7-inch 24-bit LCD touchscreen |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | DZ-STA200 |
| Coupling Technique | TG-DSC |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 5 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DZ-STA200 |
| Price Range | USD 9,800–13,900 (FOB) |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 2 g (expandable to 5 g) |
| Atmosphere Control | Inert, oxidizing, reducing |
| TG Resolution | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Calibration | Multi-point temperature & enthalpy calibration |
| Gas Control | Dual-channel mass flow control with integrated digital flow meters |
| Display | 7-inch 24-bit color LCD touchscreen |
| Data Interface | Standard USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Crucible Options | Al₂O₃ ceramic, aluminum, platinum (optional) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ-STA200 |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| TG Sensitivity | 0.1 µg |
| DSC Sensitivity | 0.1 µW |
| DSC Range | ±1000 mW |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit Color Touchscreen |
| Gas Control | Dual-channel Mass Flow Control with Built-in MFCs |
| Data Interface | Standard USB |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ-STA200 |
| Price Range | USD 11,200–14,000 (FOB) |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 2 g (expandable to 5 g) |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| TG Resolution | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Atmosphere System | Dual-channel mass flow control with integrated digital flow meters |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-STA200 |
| Price | ¥85,000 |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Options | Inert, Oxidizing, Reducing |
| Brand | Nanjing Dazhan |
|---|---|
| Model | DZ-STA200 |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Compatibility | Inert, Oxidizing, Reducing |
| TG Resolution | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit LCD Touchscreen |
| Gas Control | Dual-channel mass flow control with integrated flow meters |
| Software | Integrated thermal analysis suite with TG, DTG, and TG-DSC overlay, calibration support (temperature & enthalpy), PDF/Excel export, audit-trail-capable data logging |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | DZ-STA200 |
| Price | ¥85,000 |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 2 g (expandable to 5 g) |
| Atmosphere Control | Integrated dual-channel mass flow controller with adjustable flow rate and gas switching (inert, oxidizing, reducing |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DZ-STA200 |
| Price Range | USD 11,200–16,800 (based on exchange rate ~¥80,000–¥120,000) |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Options | Inert, oxidizing, reducing |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| TG Sensitivity | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Sensitivity | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Gas Control | Dual-channel mass flow control with integrated flow meters |
| Display | 7-inch 24-bit color LCD touchscreen |
| Data Interface | Standard USB |
| Calibration | Multi-point temperature and enthalpy calibration |
| Compliance Support | ASTM E1131, ASTM E1269, ISO 11358, ISO 17225, USP <1225>, GLP-compliant audit trail in software |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DZ-STA300 |
| Price Range | USD 16,800–21,000 (FOB) |
| Temperature Range | Ambient to 1550 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Compatibility | Inert, Oxidizing, Reducing |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-STA300 |
| Temperature Range | Ambient to 1550 °C |
| Heating Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 5 g |
| Atmosphere Options | Inert, Oxidizing, Reducing |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DZ-TGA 101 |
| Structure Type | Top-loading / Upper-mounted |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single-sample |
| Instrument Type | General-purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Accuracy | ±0.01 K |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 1–80 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Drift | ≤0.1 mg |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C |
| Mass Range | 0.1 mg–30 g |
| Atmosphere Control | Dual-gas channel with integrated mass flow meters and manual flow regulation |
| Data Interface | Standard USB |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 500×400×430 mm |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Dynamic Weight Range | 0.01 mg to 3 g |
| Balance Sensitivity | 0.01 mg (up to 2 g), extendable to 30 g |
| Mass Accuracy | 0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass Capacity | 30 g |
| Baseline Drift | Negligible (<0.1 µg over 60 min at constant temperature) |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static/dynamic) |
| Cooling Time | ≤15 min (1000 °C → 100 °C) |
| Isothermal Hold Duration | 0–500 min (extendable to 72 h) |
| Data Acquisition | 24-bit quadruple-channel ADC for TG, DTG, DSC (optional), and temperature signals |
| Controller Architecture | 32-bit ARM Cortex-M3 microcontroller + dedicated 8-bit MCU for water-cooling subsystem |
| Interface | USB 2.0 (bidirectional), touch-screen and PC remote control supported |
| Software | Integrated Windows-based analysis suite with ASTM/ISO-compliant reporting, multi-point temperature calibration, Excel/PDF export, GLP audit trail logging |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | DZ-TGA101 |
| Test Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | Excellent |
| Baseline Drift | Negligible |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Dynamic Weighing Range | 0.01 mg to 2 g (extendable to 30 g) |
| Mass Accuracy | 0.01 mg |
| Mass Resolution | 0.1 µg |
| Isothermal Hold Time | 0–500 min (expandable to 72 h) |
| Cooling Time | ≤15 min (from 1000 °C to 100 °C) |
| Atmosphere Control | Dual-gas inlet with integrated mass flow meters |
| Display | 7-inch Chinese-language LCD touchscreen |
| Data Interface | Standard USB port |
| Software | Proprietary TGA analysis suite with multi-point temperature calibration, TG/DTG curve processing, Excel export, PDF report generation, and audit-ready experimental logging |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DZ-TGA101 |
| Test Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g |
| Mass Accuracy | ±0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Mass Resolution | 0.01 mg |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | Excellent |
| Baseline Drift | Negligible |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Atmosphere Control | Dual-Gas Flow Regulation (Inert, Oxidizing, Reducing, Static, Dynamic) |
| Data Interface | USB 2.0 |
| Software | Integrated TG/DTG Analysis Suite with Excel Export, PDF Report Generation, Multi-Point Temperature Calibration, and GLP-Compliant Audit Trail |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Price Range | USD 7,000–14,000 (FOB) |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.1 µg (Resolution), 0.01 mg (Accuracy) |
| Mass Range | 0.01 mg–2 g (expandable to 30 g) |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Isothermal Hold Duration | 0–500 min (extendable to 72 h) |
| Atmosphere Control | Dual-gas inlet with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Data Interface | Standard USB 2.0 |
| Software | Proprietary Windows-based TGA analysis suite with ASTM/ISO-compliant reporting, Excel export, PDF report generation, multi-point temperature calibration, and full remote instrument control |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DZ-TGA101 |
| Testing Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Range | 0.1 mg–3 g (extendable to 30 g) |
| Isothermal Hold Duration | Up to 72 h (0–300 min programmable in 0.1 min increments) |
| Atmosphere Control | Dual-gas manifold with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Data Acquisition | 48-bit quadruple-channel ADC for simultaneous TG, DTG, DSC (optional), and temperature signals |
| Interface | USB 2.0 (bidirectional) |
| Display | 7-inch 24-bit color touchscreen (Chinese/English UI) |
| Calibration | On-screen TG baseline and temperature multi-point calibration |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DZ-TGA101 |
| Price Range | USD 7,000–14,000 (FOB) |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single-sample |
| Instrument Type | General-purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.1 mg to 3 g (standard), extendable to 30 g |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Atmosphere Control | Dual-gas channel with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Data Interface | USB 2.0 |
| Software | Proprietary TGA analysis suite with TG/DTG curve fitting, Excel/PDF export, GLP-compliant audit trail, multi-point temperature calibration, and remote instrument control |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.1 mg to 3 g (standard range), 1 mg to 2 g (high-precision range) |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Accuracy | 0.01 mg |
| Minimum Mass Resolution | 0.1 µg |
| Isothermal Hold Duration | Up to 72 h (0–300 min programmable in 0.1 min increments) |
| Atmosphere Control | Dual-gas channel with integrated mass flow meters |
| Display | 7-inch high-resolution Chinese-language LCD touchscreen |
| Data Interface | Standard USB port |
| Software | Proprietary TGA analysis suite with TG/DTG curve fitting, Excel export, PDF report generation, thermal calibration correction (multi-point), and FDA 21 CFR Part 11–compliant audit trail (optional module) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Balance Range | 0.01 mg–2 g (extendable to 30 g) |
| Balance Resolution | 0.1 µg |
| Isothermal Hold Time | 0–500 min (expandable to 72 h) |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Atmosphere Control | Dual-gas flow regulation with inert/oxidizing/reducing/static/dynamic options |
| Data Interface | USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA103 |
| Sample Capacity | 1 |
| Instrument Type | General-purpose |
| Temperature Range | Ambient to 1450 °C |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Range | 0.1 mg–2 g (extendable to 30 g) |
| Atmosphere Control | Dual-gas manifold with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Data Interface | USB |
| Software | Proprietary TGA analysis suite with TG/DTG curve generation, multi-point temperature calibration, Excel export, report printing, and GLP-compliant audit trail |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TGA-103 |
| Price Range | USD 12,500–16,800 (FOB) |
| Operating Environment | High-Temperature |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Ambient to 1350 °C |
| Temperature Accuracy | ±0.01 K |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA105 |
| Sample Capacity | 1 |
| Instrument Type | Dedicated TGA System |
| Temperature Range | Ambient to 1550 °C |
| Balance Sensitivity | 0.01 mg (full range: 0.1 mg–2 g, extendable to 30 g) |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time | ≤15 min (from 1000 °C to 100 °C) |
| Data Interface | USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | DZ-TGA105 |
| Structure Type | Top-Loading (Upper-Positioned) |
| Test Environment | High-Temperature |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Ambient to 1450 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Balance Range | 1 mg–2 g (expandable to 5 g) |
| Balance Resolution | 0.1 µg |
| Isothermal Hold Time | 0–300 min |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static, Dynamic |
| Gas Control | Dual-channel integrated mass flow controllers with adjustable flow rates |
| Data Interface | RS-232 |
| Software | Proprietary TGA analysis suite with automated curve acquisition, kinetic modeling, derivative (DTG) calculation, report generation, and free periodic updates |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA105 |
| Structure Type | Top-loading (upright) |
| Ambient Pressure Operation | Yes |
| Sample Capacity | 1 sample per run |
| Instrument Class | General-purpose TGA |
| Temperature Range | Ambient to 1550 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | High reproducibility |
| Balance Sensitivity | 0.01 mg |
| Balance Dynamic Range | 0.1 mg–2 g (extendable to 30 g) |
| Cooling Time | ≤15 min (from 1000 °C to 100 °C) |
| Data Interface | USB 2.0 |
| Control Processor | STM32 microcontroller |
| ADC Resolution | 48-bit, quad-channel for TG, DSC (if equipped), and temperature signals |
| Display | 7-inch 24-bit color touchscreen |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ3320A |
| Sample Capacity | Single |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DTA Sensitivity | 0.01 µV |
| DTA Signal Range | 0–±2000 µV (expandable) |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Control Method | PID Temperature Control |
| Furnace Design | Top-opening vertical furnace |
| Atmosphere Control | Programmable internal gas switching |
| Data Interface | Standard USB 2.0 |
| Display | 7-inch 24-bit color LCD touchscreen |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Baseline Adjustment | Adjustable slope and intercept via software |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DZ3320A |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Temperature Range | Ambient to 1200 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DTA Signal Range | 0–±2000 μV (expandable) |
| Temperature Stability | ±0.1 °C |
| DTA Sensitivity | 0.01 μV |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Control Interface | USB bidirectional communication |
| Display | 7-inch 24-bit color LCD touch screen |
| Furnace Design | Top-opening horizontal furnace |
| Sensor Material | Ni-Cr alloy thermocouple pair |
| Power Supply | AC 220 V, 50 Hz (customizable) |