BrandPri-eco
OriginBeijing, China
ManufacturerYes
Country of OriginChina
ModelPRI-8350
CO₂ Range0–5%
CO₂ PrecisionBetter than 80 ppb or 0.01% of full scale
δ¹³C Precision<0.3‰ (1σ) @ 1 s
H₂O Range0–100% RH
Sampling Frequency4 Hz (high-speed mode), 1 Hz (standard mode)
Response Time (10–90% / 90–10%)15 mL/min (fast), 5 mL/min (standard), down to 0.5 mL/min (ultra-low flow)
Number of Subsurface ChannelsStandard 6-channel
Calibration ChannelsOptional 3-channel configuration, customizable
Sampling Temperature–20 to +45 °C
Sampling Flow Rate1 mL/min at 760 Torr, filter-free operation
Sampling Pressure300–1000 Torr (40–133 kPa)
Operating Temperature–20 to +45 °C (extended range: –30 to +45 °C)
Power Consumption150 W
Input Voltage/Frequency110–220 VAC, 50–60 Hz
Dimensions (Host)483 mm (W) × 800 mm (D) × 476 mm (H)
Weight (Host)25 kg
Multiplexer UnitSame footprint, 20 kg
Diffusion ProbeStandard single-channel 3 × 1 m (length × depth), customizable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelAMBA C123+N
PriceUpon Request
Measurement PrincipleMid-infrared quantum cascade laser absorption spectroscopy coupled with high-speed gas chromatography and micro-combustion
δ¹³C Precision (C₁–C₄)<0.4‰ (1σ)
Sampling Frequency1 Hz
Cycle Time per Sample≤3 min (including C₁, C₂, C₃, and C₄ isotopic analysis)
Measurement Chamber Volume<1 mL
Operating Pressure50 Torr
Concentration RangeCH₄ >0.5% v/v
Operating Temperature0–35 °C (above dew point)
Relative Humidity<100% RH
Dimensions (Isotope Analyzer)740 × 465 × 357 mm (H)
Dimensions (Fast GC Module)675 × 558 × 370 mm (H)
Power Requirement110/220 V AC, 50/60 Hz
Peak Power3 kW
Average Power1 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelU1001
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelI3211E
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Modeli3121
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAG1000-F
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelAMBA i3211
PricingAvailable Upon Request
Measurement PrincipleMid-Infrared Hollow Waveguide Absorption Spectroscopy
Sample Chamber Volume~1 mL
δ¹³C Precision<0.08‰ (1σ, 60 s)
CO₂ Concentration Range380–5000 ppm
Sampling Frequency4 Hz (high-speed mode), 1 Hz (standard mode)
Sample Flow Rate15 mL/min (standard), 5 mL/min (low-flow mode)
Sample Cell Volume0.1 mL
Operating Temperature−10 to +45 °C
Vacuum Pump Capacity100 sccm at 50 Torr
Operating Pressure50–133 kPa
Relative Humidity Tolerance<99% RH (non-condensing at ≤40 °C, no drying required)
CalibrationFully Automated Online Calibration
Data InterfacesRS-232, Ethernet, USB
Inlet/Outlet Fittings1/8″ Swagelok® Compression Ferrules
Dimensions (W×D×H)483 × 800 × 476 mm (19″ × 31.5″ × 18.75″)
Weight25 kg
Power Supply100–240 VAC, <350 W (startup), ~200 W (steady-state)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Modeli3131
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeDistributor
Origin CategoryImported
ModelORION
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeDistributor
Origin CategoryImported
ModelORION NH3
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelI3211W
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelA0214
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelEA-I3211
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelEA-MIR
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPRI-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelPRI-501w
Measurement PrincipleDual-Wavelength Non-Dispersive Infrared (Dual-NDIR)
CO₂ Range0–2000 ppm
CO₂ Accuracy±2% of reading (±1.5% after calibration)
CO₂ Zero Stability±2% over >12 months
CO₂ Repeatability (Zero)±0.3%
CO₂ Repeatability (Span)±1.5%
CO₂ Zero Drift (Constant Temp.)±2% per year
CO₂ Zero Drift (Ambient Temp.)±0.03% per °C
H₂O Range0–6% vol
H₂O Accuracy±2% of reading
Operating Temperature−20 to +45 °C
Operating Pressure800–1150 mbar
Sample Flow Rate1 L/min (adjustable)
T₉₀ Response Time10 s (adjustable)
Warm-up Time1 min
Calibration IntervalRecommended annually
Max. Humidity<99% RH (non-condensing)
OutputsRS-232, Analog (0–5 V / 4–20 mA)
Dimensions250 × 160 × 90 mm
Weight3 kg
Power Supply7–28 V DC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelEA-HWG
PriceUpon Request
δ¹³C Precision (1σ)<0.1–0.2 ‰
CO₂ Measurement Range380–10,000 ppmv
Measurement Frequency4 Hz
Sample Flow Rate0.5 mL/s
Measurement Cell Volume<1 mL
Operating Temperature−10 to 45 °C
Miniature Vacuum Pump100 sccm @ 50 Torr
Sampling Pressure50–133 kPa
Carrier GasUltra-High-Purity N₂ or He
Combustion GasUltra-High-Purity O₂
Relative Humidity Tolerance<99% RH (non-condensing at 40 °C)
CalibrationFully Automated Online Calibration
Interface OptionsRS-232, Ethernet, USB
Inlet/Outlet Fittings1/8″ Swagelok
Dimensions (CO₂ Analyzer)483 × 800 × 476 mm (W×D×H)
Weight25 kg
Dimensions (Elemental Analyzer)813 × 394 × 508 mm
Weight68 kg
Power Requirement100–240 VAC
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelORION CO₂ CH₄
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNC Technologies
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelEA-IRMS-iRIS
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
ManufacturerPri-eco
Country of OriginDomestic (China)
ModelPRI-8400
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHD Rocksand
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
ManufacturerYes
Country of OriginDomestic (China)
ModelPRI-3100
PricingUpon Request
Channels16 independent
Ultimate Vacuum Pressure0.3 Pa
Pressure Range0.1–10⁵ Pa
Pressure Resolution0.1 Pa
HeatingWater Bath, Up to 100 °C
CoolingLiquid Nitrogen, Down to −196 °C
Sample Tube Dimensions25 mm × 150 mm
Collection Tube Dimensions12.7 mm × 150 mm
System Leak Rate≤1 Pa/min
Extraction Recovery Rate99.5–100%
Max Throughput256 samples/day
Vacuum Pump Flow Rate≥8 m³/h
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelORION CH4
PricingAvailable Upon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0