Empowering Scientific Discovery

Beijing Pure-Science Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelPRI-503
Detection PrincipleDual-Wavelength Non-Dispersive Infrared (Dual-NDIR)
Measurable GasesCO₂, CH₄, H₂O
CO₂ Range Options0–0.2%, 0.5%, 1%, 5%, 10%, 100%
CH₄ Range Options0–5%, 10%, 30%
H₂O Range0–6%
CO₂/CH₄ Accuracy±2% (±1.5% after calibration)
Zero Stability (CO₂/CH₄)±2% over >12 months
Repeatability (Zero/Span)±0.3%/±1.5%
Zero Drift (Constant Temp.)±2%/year
Zero Drift (Ambient Temp.)±0.03%/°C
H₂O Accuracy±2%
Operating Temperature−20 to +45 °C
Operating Pressure800–1150 mbar
Sample Flow Rate1 L/min (adjustable)
T90 Response Time10 s (adjustable)
Warm-up Time1 min
Humidity Limit<99% RH, non-condensing
OutputsRS-232, Analog (4–20 mA / 0–10 V)
Dimensions250 × 160 × 90 mm
Weight2.2 kg
Power Supply7–28 V DC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelPRI-502
Detection PrincipleDual-Wavelength Non-Dispersive Infrared (Dual-NDIR)
Measurable GasesCH₄ (0–50,000 ppm), H₂O (0–6% vol)
Accuracy±2% FS (CH₄), ±2% FS (H₂O)
Zero Stability (CH₄)±2% FS over >12 months
Repeatability (CH₄)±0.3% FS at zero, ±1.5% FS at span
Temperature Drift (CH₄)±0.03% FS/°C (ambient), ±2% FS/year (thermostated)
Operating Temperature−20 to +45 °C
Operating Pressure800–1150 mbar
Sample Flow Rate1 L/min (adjustable)
T90 Response Time10 s (adjustable)
Warm-up Time1 min
Humidity Range<99% RH, non-condensing
Output InterfacesRS-232, analog (4–20 mA / 0–10 V)
Dimensions250 × 160 × 90 mm
Weight1.2 kg
Power Supply7–28 V DC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelZERO Mobile-Mounted
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Detectable Gases & RangesCH₄ (0–10,000 ppm), C₂H₆ (0–1,000 ppm), H₂O (0–3 %)
Accuracy (1 s)CH₄: 1 ppb, C₂H₆: 0.5 ppb, H₂O: 50 ppm
Data Update Rate1–5 Hz
Sample Flow Rate~330 mL/min
Operating Temperature−10 to +45 °C
Relative Humidity Limit<99 % RH (non-condensing)
PositioningHigh-Accuracy BeiDou GNSS + Wind Correction
Power ConsumptionAnalyzer: 20–40 W
Full System (incl. pump)≤80 W
Weight8.3 kg
Dimensions450 × 350 × 150 mm
Data Storage256 GB–2 TB onboard + unlimited cloud archive
Communication InterfacesWi-Fi, 5G, RS-232, Ethernet
Leak Localization Accuracy<1 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelPRI-5231
PriceUpon Request
Application FieldEnvironmental Monitoring
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Measured Gases and RangesCO₂ (0–3500 ppm), N₂O (0–500 ppb), H₂O (0–3 %v/v)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelZERO Aerial Edition
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Target Gases & RangesCH₄ (0–10,000 ppm), C₂H₆ (0–1,000 ppm), H₂O (0–3 %v/v)
Sensitivity (1-s)CH₄: 1 ppb, C₂H₆: 0.5 ppb, H₂O: 50 ppm
Measurement Update Rate1–5 Hz
Sample Flow Rate~330 mL/min
Operating Temperature−10 to +45 °C
Relative Humidity Limit<99% RH (non-condensing)
Power Supply12–15 V DC
Analyzer Power Consumption20–40 W
UAV Integration Power DrawUp to 500 W
PositioningHigh-Accuracy BeiDou GNSS + Wind Compensation Algorithm
Leak Localization Accuracy<1 m (typical)
Data OutputRS-232, Ethernet
Onboard Storage32 GB
Battery Autonomy≥1.5 h (standalone operation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelPRI-5233
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Measured GasesCH₄ (0–500 ppm), C₂H₆ (0–500 ppm), H₂O (0–3 %v/v)
Precision (1 s)1 ppb CH₄, 0.5 ppb C₂H₆, 50 ppm H₂O
Precision (1 min)0.3 ppb CH₄, 0.10 ppb C₂H₆, 40 ppm H₂O
Precision (5 min)0.2 ppb CH₄, 0.08 ppb C₂H₆, 10 ppm H₂O
Sampling Flow Rate~180 mL/min
Operating Temperature–10 to +45 °C
Relative Humidity Limit<99% RH, non-condensing
Data OutputUSB, RS-232
Power Supply110–230 V AC
Power Consumption50 W (steady-state), 90 W (warm-up)
Weight10.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPRI-ECO
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelPRI-5251e
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Measured GasesCO₂, CH₄, N₂O, H₂O
Measurement Frequency10 Hz
Accuracy (0.1 s)0.25 ppm CO₂, 1 ppb CH₄, 0.4 ppb N₂O, 50 ppm H₂O
24-h Drift1 ppm CO₂, 2 ppb CH₄, 1 ppb N₂O
Sample Temperature Range−10 to 45 °C
Sample Humidity Range<99% RH, non-condensing
Sample Flow Rate~12 L/min
Power Supply110–230 V AC
Power Consumption200 W (steady-state), 250 W (warm-up)
Dimensions440 × 190 × 530 mm
Weight25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPRI-ECO
ModelPRI-5232
Detection PrincipleMid-Infrared Laser Absorption Spectroscopy (MIRLAS)
Measured GasesCO, N₂O, H₂O
Accuracy (1 s)0.6 ppb (CO), 0.4 ppb (N₂O), 50 ppm (H₂O)
Accuracy (1 min)0.4 ppb (CO), 0.08 ppb (N₂O), 40 ppm (H₂O)
Accuracy (5 min)0.2 ppb (CO), 0.05 ppb (N₂O), 10 ppm (H₂O)
Measurement Range0–500 ppm (CO), 0–500 ppm (N₂O), 0–3 %v/v (H₂O)
24-h Drift≤0.3 ppb (CO), ≤0.2 ppb (N₂O)
Sampling Flow Rate~200 mL/min (standard), optional 1000 mL/min pump
Sampling Temperature−10 to +45 °C
Sampling Humidity<99% RH, non-condensing
Data OutputWiFi, USB, RS-232
Power Supply110–230 V AC
Power Consumption40 W (steady-state), 60 W (warm-up)
Dimensions440 × 190 × 530 mm
Weight12 kg
ComplianceWMO GHG Observing Guidelines
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelPRI-5352i
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Target GasCO₂
δ¹³C Precision<0.1 ‰ @ 1 s, 0.03 ‰ @ 300 s
δ¹⁸O Precision<0.2 ‰ @ 1 s, 0.03 ‰ @ 300 s
CO₂ Range0–1000 ppmv
H₂O Range0–3 % (accuracy-critical), 0–7 % (operational)
Max Peak-to-Peak Drift<1 ‰ over >24 h
Sample Temp−10 to +45 °C
Sample Humidity<99 % RH (non-condensing)
Flow Rate~300 mL/min
Output InterfacesUSB, RS-232
Power110–230 V AC or battery
Dimensions440 × 190 × 530 mm
Weight10.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelPRI-6250
Detection PrincipleOptical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS)
Target GasesCO, CO₂, CH₄, H₂O
Measurement RangeCO (0–30 ppm), CO₂ (350–1200 ppm), CH₄ (1–12 ppm), H₂O (0–3 %v/v)
Precision (5-min avg)<1 ppb (CO), <80 ppb (CO₂), <1 ppb (CH₄), <60 ppm (H₂O)
Drift (24 h)<3 ppb (CO), <0.5 ppm (CO₂), <3 ppb (CH₄)
Response Time<4 s
Sampling Flow Rate~200 mL/min
Data OutputEthernet (TCP/IP, Modbus TCP), RS-232/485, Analog (4–20 mA / 0–10 V), USB
Power Supply110–230 VAC, 50–60 Hz
Power Consumption150 VA
Dimensions19″ rack-mount, 4U (height: 178 mm)
Weight20 kg
Operating EnvironmentSample Temp. −10 to +45 °C
Cavity Temp. Stability±0.002 K
Cavity Pressure Stability±0.016 mbar
Mirror Reflectivity>99.999% (three ultra-high-reflectivity cavity mirrors)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPRI-ECO
ModelPRI-5251 PLUS
OriginBeijing, China
ManufacturerPRI-ECO (Domestic)
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Measured GasesCO, CO₂, CH₄, N₂O, H₂O
Precision (1 s)0.6 ppb (CO), 0.2 ppm (CO₂), 1 ppb (CH₄), 0.2 ppb (N₂O), 50 ppm (H₂O)
Precision (1 min)0.4 ppb / 0.05 ppm / 0.3 ppb / 0.05 ppb / 40 ppm
Precision (5 min)0.2 ppb / 0.04 ppm / 0.2 ppb / 0.03 ppb / 10 ppm
Measurement Range0–500 ppm (CO), 0–3500 ppm (CO₂), 0–500 ppm (CH₄), 0–500 ppm (N₂O), 0–3 %v/v (H₂O)
Drift (24 h)0.3 ppb / 0.2 ppm / 2 ppb / 0.2 ppb / —
Sampling Temp.−10 to +45 °C
Sampling Humidity<99% RH, non-condensing
Flow Rate~540 mL/min
Output Frequency1 Hz per gas
Data InterfacesUSB, RS-232
Power Supply110–230 V AC
Power Consumption120 W (steady), 150 W (warm-up)
Dimensions440 × 190 × 530 mm
Weight18.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelELF-600
Detection Gases & RangesCO₂, N₂O, CH₄ (greenhouse gases), CO (combustion byproduct), H₂O (water vapor)
Max Takeoff Weight22.5 kg
Rotor Span (Diagonal)1.6 m
Max Speed45 km/h
Service Ceiling5000 m
Climb Rate5 m/s
Wind ResistanceLevel 6 (Beaufort scale)
Control Link900 MHz RF
Navigation SystemDual-GNSS (GPS + BeiDou)
Endurance80 min (empty), 60 min (5 kg payload)
Control Radius20 km
Payload OptionsFull-frame aerial survey camera (35 mm sensor, 42 MP), multispectral camera (VIS–NIR bands), GHG analyzer module, thermal imager, loudspeaker, spotlight, aerial payload dispenser
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelPRI-5251f
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Measured GasesCO₂ (0–3500 ppm), CH₄ (0–500 ppm), N₂O (0–500 ppm), H₂O (0–3 %v/v)
Precision (1-s)0.5 ppm CO₂, 2 ppb CH₄, 0.3 ppb N₂O, 50 ppm H₂O
Precision (5-s)0.4 ppm CO₂, 0.5 ppb CH₄, 0.25 ppb N₂O, 40 ppm H₂O
Sampling Flow Rate~360 mL/min
Operating Temperature−10 to +45 °C
Relative Humidity Limit<99% RH, non-condensing
Power Consumption35 W
Weight5 kg
Data OutputWiFi, USB, RS-232
Power SupplyDC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
ManufacturerYes
Country of OriginChina
ModelPRI-5251f Plus
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Measured GasesCO, CO₂, CH₄, N₂O, H₂O
Accuracy (1s)0.7 ppb (CO), 0.5 ppm (CO₂), 1 ppb (CH₄), 0.3 ppb (N₂O), 50 ppm (H₂O)
Accuracy (5s)0.5 ppb (CO), 0.4 ppm (CO₂), 0.5 ppb (CH₄), 0.25 ppb (N₂O), 40 ppm (H₂O)
Measurement Range0–500 ppm (CO), 0–3500 ppm (CO₂), 0–500 ppm (CH₄), 0–500 ppm (N₂O), 0–3 %v/v (H₂O)
Sampling Rate1 Hz
Operating Temperature−10 to +45 °C
Relative Humidity Limit<99% RH, non-condensing
Power SupplyDC
Power Consumption50 W
Weight8 kg
Data OutputWi-Fi, USB, RS-232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
ModelAirPlus
Detection PrincipleMid-Infrared Laser Absorption Spectroscopy (MIRLAS)
Measured GasesCO₂, N₂O, H₂O
CO₂ Range0–3500 ppm
N₂O Range0–500 ppb
H₂O Range0–3%
Precision (1s)0.25 ppm CO₂, 0.25 ppb N₂O, 50 ppm H₂O
Precision (5s)0.12 ppm CO₂, 0.12 ppb N₂O, 40 ppm H₂O
Precision (5 min)0.012 ppm CO₂, 0.012 ppb N₂O, 10 ppm H₂O
Sample Flow Rate~180 mL/min (optional 1000 mL/min pump)
Operating Temperature−10 to +45 °C
Relative Humidity Limit<99% RH, non-condensing
Power Consumption15 W (steady-state)
Dimensions29 cm × 20 cm × 9.5 cm
Weight2.75 kg
Response Rate1 or 2 Hz
Data InterfacesWi-Fi, USB, RS-232
Optional OutputsAnalog (4–20 mA), GPS module
Battery Life6 hours (internal Li-ion)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPRI-ECO
ModelPRI-5251
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Measured GasesCO₂ (0–3500 ppm), CH₄ (0–500 ppm), N₂O (0–500 ppm), H₂O (0–3 %v/v)
Precision (1 s)0.2 ppm CO₂, 1 ppb CH₄, 0.2 ppb N₂O, 50 ppm H₂O
Precision (5 min)0.04 ppm CO₂, 0.2 ppb CH₄, 0.03 ppb N₂O, 10 ppm H₂O
Drift (24 h)0.2 ppm CO₂, 2 ppb CH₄, 0.2 ppb N₂O
Sampling Flow Rate~360 mL/min
Operating Temperature−10 to +45 °C
Relative Humidity<99% RH, non-condensing
Output Frequency1 Hz
Power Supply110–230 V AC
Power Consumption80 W (steady-state), 120 W (warm-up)
Dimensions440 × 190 × 530 mm
Weight14.7 kg
ComplianceWMO Greenhouse Gas Observing Network (GGON) specifications
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelPRI-732
Detection PrincipleMid-infrared Quantum Cascade Laser (QCL) coupled with Photoacoustic Spectroscopy (PAS)
Accuracy±1% of reading or LOD (whichever is greater)
Measurable GasesCO₂, CH₄, N₂O, H₂O
Response Time (T90)< 10 s
Repeatability±1% of reading or LOD (whichever is greater)
Measurement Cell Volume1 mL
Gas Consumption< 80 mL/min
Power Consumption75 W
Weight15 kg
Output InterfacesEthernet, Modbus TCP/IP & RTU, USB
Operating Temperature−10 to +45 °C
Relative Humidity< 99% RH (non-condensing)
Detection Limits (LoD)CO₂: 1 ppm, CH₄: 0.4 ppm, N₂O: 0.15 ppm, H₂O: 0.01 % (100 ppm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelPRI-501
Detection PrincipleDual-Wavelength Non-Dispersive Infrared (Dual-NDIR)
Measurable GasesCO₂ (0–2000 ppm), H₂O (0–6 % vol)
Accuracy±2 % of reading (CO₂), ±2 % of reading (H₂O)
Zero Stability (CO₂)±2 % over 12 months
Repeatability (CO₂)±0.3 % at zero, ±1.5 % at span
Temperature Drift (CO₂)±0.03 %/°C (ambient), ±2 %/year (thermostated)
Operating Temperature−20 to +45 °C
Operating Pressure800–1150 mbar
Sample Flow Rate1 L/min (adjustable)
T90 Response Time10 s (adjustable)
Warm-up Time1 min
Humidity Range<99 % RH, non-condensing
Output InterfacesRS-232, analog (0–5 V / 4–20 mA)
Dimensions & Weight250 × 160 × 90 mm, 1.2 kg
Power Supply7–28 V DC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelPRI-8500 CO₂/H₂O
Accuracy±2%, <±1.5% after calibration
Measured GasesCO₂ (0–2000 ppm), H₂O (0–6% vol)
Response Time (T90)10 s (adjustable)
RepeatabilityZero point ±0.3%
Operating Temperature−30 to +45 °C
Operating Pressure80–115 kPa
Relative Humidity Range<99% RH, non-condensing at 45 °C
Sample Flow Rate1 L/min (analyzer), 11 L/min (multiplexer system)
Calibration IntervalRecommended annually
Multiplexer Configuration4+4 dual-channel design with 3 calibration gas ports and 8 sample gas ports
Gas SwitchingDual-pump architecture
InterfaceTablet-based touchscreen control
Inlet/Outlet Fitting1/4″ Swagelok®-compatible compression fittings
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelPRI-701
Detection PrincipleMid-infrared Quantum Cascade Laser (QCL) coupled with Photoacoustic Spectroscopy (PAS)
Target GasNH₃
Detection Limit (3σ, 60 s)0.1 ppm
Repeatability<2% of reading or LOD
Accuracy<2% of reading or LOD
Response Time (10–90%)<130 s
Maximum Measurement Rate>10 Hz
Measurement Range0–100 ppm (customizable)
Sample Cell Volume1 mL
Gas Consumption<80 mL/min
Sample Temperature Range−10 to 45 °C
Sample Humidity Limit<99% RH (non-condensing)
Power SupplyDC
Power Consumption20 W
Weight3 kg
Data OutputEthernet, Modbus TCP/IP & RS, USB
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelZERO Portable
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Target Gases & RangesCH₄ (0–10,000 ppm), C₂H₆ (0–1,000 ppm), H₂O (0–3 %)
Accuracy (1 s)CH₄: 1 ppb, C₂H₆: 0.5 ppb, H₂O: 50 ppm
Data Update Rate1–5 Hz
Sample Temperature Range−10 to +45 °C
Sample Flow Rate330 mL/min
Power Supply9–36 V DC, 2–4 A, 20–40 W
Weight4.1 kg
Dimensions365 × 295 × 170 mm
Battery Runtime>7 h
Onboard Storage32 GB
Cloud IntegrationUnlimited
Data OutputWi-Fi, 5G
Data SecurityEnd-to-end encryption, local server option
Environmental RatingTested for shock, vibration, and thermal cycling per IEC 60068-2 standards
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0