PULUODY
Filter
Showing 211–240 of 412 results
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601Y |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 1–450 µm (customizable to 0.03–3000 µm) |
| Channel Count | 1000 adjustable size channels |
| Sampling Flow Rate | 5–150 mL/min |
| Cleaning Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Accuracy | ±5% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), >90% (ISO 21501-2 compliant) |
| Software | V8.9 Regulatory-Compliant Analysis Suite |
| Compliance | FDA 21 CFR Part 11, GMP/GLP Audit Trail, Electronic Signature, Five-Tier User Access Control |
| Standards Supported | ChP 0903 (2015/2020), USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-2, ISO 11171, GB/T 11446.9-2013, YBB00272004-2015, GB 8368 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601Z |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Sample Introduction | Disposable Needle Sampling Probe |
| Channel Resolution | 1000 Adjustable Channels (Down to 0.01 µm) |
| Detection Range | 1–450 µm (Extended options: 0.03–3000 µm) |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Repeatability | ≤3% coincidence error at 1000 particles/mL |
| Flow Rate | 5–150 mL/min (sampling), 5–500 mL/min (rinse) |
| Temperature Range | Fluid 0–80 °C |
| Compliance | Meets ChP 0903, USP <788>/<789>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9–2013, YBB00272004–2015, GB 8368 |
| Software | V8.9 Regulatory-Grade Analysis Suite (FDA 21 CFR Part 11 Compliant) |
| Data Integrity | Audit Trail, Electronic Signature, Role-Based 5-Tier User Permissions, Auto Backup/Restore, Power-Fail Recovery |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601ZY |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Particle Sensing |
| Channel Count | 1000 adjustable channels |
| Detection Range | 1–450 µm |
| Minimum Detectable Size | 0.01 µm (c) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Temperature | 0–50 °C |
| Accuracy | ±5% typical (per USP <788>, ISO 21501) |
| Coincidence Limit | ≤5% at 1000 particles/mL |
| Resolution | >95% (ChP 2020 calibration), <10% (USP/ISO 21501 calibration) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Software Compliance | FDA 21 CFR Part 11, ALCOA+ principles, audit trail, electronic signature, data backup & restore, power-fail recovery |
| Regulatory Standards Supported | ChP 0903 (2015/2020), USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, WHO IntPh IV, YBB00272004-2015, ISO 4406, ISO 11171, NAS 1638, SAE AS4059, MIL-STD-1246C, GB/T 14039, DL/T 432, GJB/T 420A/B, GB/T 18854 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PLD-6532A |
| Pricing | Available Upon Request |
| Standard Compliance | GB/T 6532–2019 |
| Temperature Control | Digital PID-controlled heating system (range: ambient to 80 °C, ±0.5 °C stability) |
| Extraction Configuration | Dual independent extraction units with synchronized solvent delivery |
| Pressure Regulation | Precision digital pressure controller (0–0.6 MPa, resolution 0.01 MPa) |
| Display Interface | Backlit LCD with real-time parameter monitoring |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-6536B |
| Heating Power | 0–1200 W (continuously adjustable) |
| Heating Mantle Vertical Adjustment Range | 35 mm |
| Flask Support Plate Aperture Options | Ø37.5 mm and Ø50 mm |
| Condensate Bath Temperature Range (with chiller) | –5 to 80 °C |
| Power Supply | AC 220 V, 50 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-6536B |
| Heating Power | 0–1200 W (continuously adjustable) |
| Heating Mantle Vertical Adjustment Range | 35 mm |
| Flask Support Plate Apertures | Ø37.5 mm and Ø50 mm |
| Condensate Bath Temperature Range | –5 °C to 80 °C (with integrated refrigeration unit) |
| Power Supply | AC 220 V, 50 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-6536C |
| Heating Power | 0–2000 W (continuously adjustable) |
| Heating Chamber Vertical Adjustment Range | 35 mm |
| Flask Support Plate Aperture | Ø37.5 mm |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Display Resolution | 0.1 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Refrigeration System | Imported Compressor |
| Condensate Bath Temperature Range | 0–80 °C |
| Compliance | GB/T 6536, ASTM D86, ISO 3405 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PLD-820X |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Measurement Range | 1–450 µm |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Channel Resolution | 1000 adjustable channels (16 user-selectable) |
| Viscosity Handling | Up to 1850 mm²/s (cSt) without dilution or heating |
| Sample Volume | 1 mL to unlimited (user-defined) |
| Sampling Flow Rate | 5–60 mL/min |
| Accuracy | ±1% volumetric delivery |
| Coincidence Limit | 10,000 particles/mL (≤5% coincidence error) |
| Standards Compliance | ISO 4406, ISO 11500, ISO 11171, NAS 1638, GJB 420A/B, DL/T 432, MIL-STD-1246, ASTM D6786 (referenced), GB/T 18854-2002 |
| Calibration Reference | NIST-traceable GBW standard reference materials |
| Operating Temperature | Ambient to 65°C (sample), 0–50°C (ambient) |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PLD-820X-1 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Measurement Range | 1–450 µm |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Channel Resolution | 1000 adjustable channels (up to 16 active per test) |
| Viscosity Handling | ≤1850 mm²/s (cSt) |
| Sample Volume | 1 mL to unlimited (user-defined) |
| Flow Control | Precision piston pump + electromagnetic flow regulation (5–60 mL/min, accuracy ±1%) |
| Test Duration | Configurable, default 20 s |
| Repeatability | ≤5% coincidence error at 10,000 particles/mL |
| Operating Temp. | Ambient to 65 °C |
| Ambient Temp. | 0–50 °C |
| Power | 220 V, 50 Hz, <80 W |
| Compliance Standards | ISO 11500, ISO 4406, ISO 11171, NAS 1638, GJB 420A/B, GJB 380, MIL-STD-1246, DL/T 432, DL/T 1096, ROCT 17216, GB/T 18854–2002 |
| Calibration Reference | NIST-traceable GBW standard particles |
| Data Storage | 3000 tests onboard (industrial PC), unlimited via external PC |
| Interface | RS232, optional Wi-Fi/Bluetooth (customizable) |
| Display | 8.2″ color TFT-LCD touch interface running PULUODY ColorOS v8.2 |
| Software | P6.4 Particle Analysis Suite (embedded & PC versions) |
| Optional Modules | Water saturation detection, moisture content analysis |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | PLD-CX |
| Measurement Parameters | Gasoline Octane Number (RON), Diesel Cetane Number |
| Portability | Portable |
| Measurement Range | 40–120 (Octane), 20–100 (Cetane) |
| Measurement Accuracy | ±0.5–1.0 units |
| Measurement Time | ≤10 seconds per sample |
| Sample Volume | 10 mL |
| Compliance Standard | GB/T 18339–2001 (Gasoline Octane Number Determination by Dielectric Constant Method) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PLD-CX-a |
| Measurement Parameters | Gasoline Research Octane Number (RON), Diesel Cetane Number (CN) |
| Portability | Handheld |
| Measurement Range | 40–120 (RON/CN scale) |
| Accuracy | ±0.5 RON/CN |
| Measurement Time | ≤10 seconds |
| Sample Volume Required | 10 mL |
| Operating Environment | 0–30 °C, ≤85% RH |
| Repeatability | ±0.2 RON |
| Reproducibility | ±0.4 RON |
| Resolution | 0.1 RON/CN |
| Response Time | <1 s |
| Power Input | 100–240 VAC, 50/60 Hz |
| DC Output | 5 VDC / 1000 mA |
| Compliance Standard | GB/T 18339–2001 (Gasoline Octane Determination by Dielectric Constant Method) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-FX-801 |
| Instrument Type | Optical Particle Counter (Light Obscuration & Light Scattering Dual-Mode) |
| Detection Range | 0.5–100 µm |
| Channel Resolution | Up to 1000 user-configurable size channels (16 standard) |
| Sampling Flow Rate | 5–150 mL/min |
| Counting Accuracy | ±3% |
| Sizing Accuracy | ≥90% |
| Sample Volume Precision | ±1% |
| Measurement Time | 5 s to user-defined |
| Calibration Standard | NIST-traceable latex spheres |
| Operating System | Windows-based control software |
| Communication Interface | Standard TCP/IP |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-FX-801PL |
| Detection Principle | Dual-mode (Light Scattering + Light Obscuration) |
| Sensor Generation | 8th-generation dual-laser narrow-beam particle sensor |
| Measuring Range | 0.5–100.0 µm |
| Customizable Channels | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | <±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision metering pump with dual-stage automatic dilution |
| Data Output | 4–20 mA analog interface with configurable alarm trigger |
| Calibration Standards | JJG 1061, ISO 21501, or NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Compliance Support | GLP/GMP audit trail logging, FDA 21 CFR Part 11-ready configuration options |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Model | PLD-FX-801 |
| Detection Principle | Dual-mode (Light Obscuration + Light Scattering) |
| Sensor Generation | 8th-generation dual-laser collimated beam sensor |
| Measuring Range | 0.5–100.0 µm |
| Customizable Channels | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision metering pump |
| Output | 4–20 mA analog interface with configurable alarm |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Compliance Support | GLP/GMP audit trail, FDA 21 CFR Part 11 ready (optional configuration) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Model | PLD-FX-801LX |
| Detection Principle | Dual-mode (Light Obscuration + Light Scattering) |
| Sensor Generation | 8th-generation dual-laser narrow-beam particle sensor |
| Measurement Range | 0.5–100.0 µm |
| Customizable Sub-ranges | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Sample Delivery | Precision metering pump |
| Output | 4–20 mA analog interface with configurable alarm triggers |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen GUI) |
| Compliance Support | GLP/GMP audit trail logging, FDA 21 CFR Part 11–ready configuration options |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-FX-801ZX |
| Instrument Type | Optical Particle Counter (Dual-Mode: Light Scattering + Light Obscuration) |
| Detection Range | 0.5–100.0 µm |
| Customizable Sub-Ranges | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | <±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output | 4–20 mA analog interface with configurable超标 alarm |
| Calibration Standards | JJG 1061, ISO 21501, or NIST-traceable latex sphere reference |
| Software | V8.3 Integrated Analysis & Calibration Platform (PC + touchscreen UI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Model | PLD-GS2 |
| Type | Orbital Shaker |
| Display | LED Digital Speed & Timer |
| Drive Mechanism | Eccentric Cam with Belt-Driven Motion |
| Platform Size | 300 × 300 mm (standard) |
| Speed Range | 30–300 rpm |
| Speed Accuracy | ±1 rpm |
| Timer Range | 1–999 min |
| Platform Load Capacity | ≤5 kg |
| Noise Level | ≤50 dB(A) |
| Construction | Powder-Coated Steel Frame with Stainless Steel Platform |
| Compliance | CE, ISO 9001, GB/T 12803–2021 (Laboratory Equipment – Orbital Shakers) |
| Brand | PULUODY |
|---|---|
| Model | PLD-GS2 |
| Drive Type | Orbital (Circular) Motion |
| Speed Range | 40–350 rpm |
| Display | Digital LED Speed & Timer |
| Timer Range | 1–10 h or Continuous Operation |
| Platform Dimensions | 360 × 360 mm |
| Oscillation Amplitude | 20 mm (customizable eccentricity available) |
| Max Load Capacity | 8 kg |
| Motor Power | 32 W |
| Input Voltage | AC 100–220 V, 50/60 Hz |
| Platform Material | Stainless Steel with Adjustable Spring-Loaded or Belt-Type Clamps (custom fixtures supported) |
| Noise Level | <55 dB(A) |
| Dimensions (L×W×H) | 450 × 390 × 110 mm |
| Net Weight | 11 kg |
| Compliance | CE-marked design principles |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-GS2 |
| Drive Type | Belt-driven orbital motion |
| Display | Digital speed & timer display |
| Speed Range | 30–300 rpm (adjustable) |
| Timer Range | 1–999 minutes |
| Platform Size | 300 × 300 mm |
| Load Capacity | ≤5 kg |
| Operating Noise | <50 dB(A) |
| Construction | Stainless steel platform with corrosion-resistant frame |
| Clamp System | Stainless steel spring clamps (customizable for vials, flasks, tubes, microplates) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Compliance | CE-marked design principles |
| Brand | PULUODY |
|---|---|
| Model | PLD-IGS-2025 |
| Origin | Shaanxi, China |
| Housing Material | 316L Stainless Steel |
| Sample Volume | 1 L |
| Maximum Working Pressure | ≥1.3 MPa |
| Vacuum Pump Control Threshold | 1.3 MPa (auto-shutoff with overpressure cutoff and audible/visual alarm) |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows, compatible with ASTM D6164 (gas sampling for radionuclide analysis), USP <661>, and IAEA Safety Standards RS-G-1.7 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-IGS-2025 |
| Price | USD 3,650 (FOB) |
| Vessel Material | 316L Stainless Steel |
| Vessel Capacity | 1 L |
| Maximum Working Pressure | ≥1.3 MPa |
| Vacuum Pump Control Threshold | 1.3 MPa (auto-shutoff with audible/visual alarm) |
| Safety Features | Overpressure cutoff, leak-resistant isolation valve, pressure relief mechanism |
| Compliance | Designed to meet ASTM D6159–22 (Standard Practice for Sampling Gaseous Effluents), ISO 8573-1:2010 (Compressed Air – Part 1: Contaminants and Purity Classes), and IAEA Safety Standards Series No. SSG-24 (Radiation Protection and Safety of Radiation Sources) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | PLD-MPCS Series |
| Instrument Type | Optical Microscopy-Based Particle Counter |
| Key Imaging Resolution | 0.1 µm |
| Measurement Range | 1–500 µm |
| Magnification | 40×–1000× |
| CCD Sensor | ≥5 MP (standard configuration) |
| Repeatability Error | < 5% (excluding sample preparation variability) |
| Particle Segmentation Speed | < 1 s per field |
| Segmentation Success Rate | > 93% |
| Software Platform | Windows OS-compatible image analysis suite with RS232/USB interface |
| Compliance Standards | ISO 16232, ISO 4406, VDA 19, GME 7061, GMW 16037-2017, JB/T 7858, GB/T 20110, DL 432 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0 |
| Measurement Principle | Digital Microscopy + Automated Image Analysis |
| Particle Detection Range | 1–500 µm |
| Magnification | 40×–1000× |
| Maximum Resolution | 0.1 µm |
| Microscope Accuracy | ±0.02 µm (excluding sample preparation effects) |
| Repeatability Error | <5% (excluding sample preparation effects) |
| CCD Camera | 5–18 MP |
| Particle Segmentation Speed | <1 s per frame |
| Segmentation Success Rate | >93% |
| Software Platform | Windows 10 |
| Interface | RS232 or USB |
| Measurement Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Classification Resolution | >95% |
| Compliance Support | ISO 4406, NAS 1638, ISO 16232, VDA 19.1, SAE AS4059, ASTM F3217 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-MPCS2.0 |
| Price | USD 51,200 (FOB China) |
| Compliance | ChP 2020 Appendix 0903 Method 2 (Microscopic Particle Counting), USP <788>, USP <789>, EP 8.0, ISO 21501-4, ISO 21510, GB/T 11446.9-2013 |
| Measurement Principle | Bright-field Microscopy + Digital Image Analysis |
| Particle Detection Range | 1–500 µm |
| Magnification | 40×–1000× |
| Resolution | 0.1 µm |
| Repeatability Error | <5% (excluding sample preparation variability) |
| CCD Sensor | 3 MP monochrome digital camera |
| Calibration Traceability | Northwest Metrology & Testing Center (Civil Products) |
| Software Platform | Windows XP/7/10 (32/64-bit), RS232/USB interface |
| Image Processing Speed | <1 sec per frame segmentation |
| Segmentation Success Rate | >93% |
| Accuracy | ±3% typical (ChP 2020 reference), >95% resolution (ChP 2020), <10% misclassification rate (USP/ISO 21501-4) |
| Reporting | ASTM E2457-compliant output, GLP audit trail enabled, FDA 21 CFR Part 11 optional module available |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-MPCS2.0 |
| Price | USD 50,000 (FOB) |
| Measurement Principle | Brightfield Microscopy + Digital Image Analysis |
| Compliance | Chinese Pharmacopoeia ChP 0903 Method 2 (Microscopic Particle Counting), USP <788>, USP <789>, EP 2.9.19, ISO 21501-4, ISO 21510, GB/T 11446.9-2013 |
| Particle Detection Range | 1–500 µm |
| Magnification | 40×–1000× |
| Resolution | 0.1 µm |
| Repeatability Error | <5% (excluding sample preparation variability) |
| CCD Sensor | 3 MP monochrome digital camera |
| Calibration Traceability | Northwest Metrology & Testing Center (Civil Products) |
| Software Platform | Windows 2000/XP compatible |
| Interface | RS-232 or USB 2.0 |
| Automatic Field Stitching | Full membrane scan with seamless mosaic generation |
| Particle Segmentation Speed | <1 s per image |
| Segmentation Success Rate | >93% |
| Accuracy | ±3% typical (ChP 2020 reference calibration) |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Resolution Performance | >95% (ChP 2020), <10% false-negative rate (USP/ISO 21501-4) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Microscopy-Based Particle Counting System |
| Measurement Range | 1 µm – 500 µm |
| Repeatability | < 5% (excluding sample preparation variability) |
| Analysis Time | 60 seconds |
| Magnification | 40× – 1000× |
| Resolution | 0.1 µm |
| Microscope Accuracy | ±0.02 µm |
| CCD Camera | 3 MP |
| Calibration Standard | NIST-traceable stage micrometer (0.1 µm division) |
| Software Environment | Windows OS (XP through 11) |
| Interface | RS-232 or USB |
| Particle Recognition Accuracy | >95% (per ChP 2020), <10% misclassification (per USP <788> & ISO 21501-1) |
| Overlap Tolerance | ≤5% at 10,000 particles/mL |
| Image Stitching | Fully automated, seam-free membrane scanning |
| Segmentation Speed | <1 second per field |
| Segmentation Success Rate | >93% |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0 |
| Magnification Range | 40×–1000× |
| Resolution | 0.1 µm |
| Measurement Range | 1–500 µm |
| Repeatability Error | <5% |
| Accuracy | ±3% (typical) |
| Particle Segmentation Speed | <1 s |
| Segmentation Success Rate | >93% |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0 |
| Instrument Type | Optical Microscopy-Based Particle Counter |
| Measurement Principle | ISO 21501-4 / USP <788> Microscopic Particle Counting Method |
| Test Range | 1–500 µm |
| Magnification | 40×–1000× |
| Resolution | 0.1 µm |
| Microscope Accuracy | ±0.02 µm (excluding sample preparation variability) |
| Repeatability Error | <5% (excluding sample preparation variability) |
| CCD Camera | 3 MP |
| Calibration Standard | NIST-traceable stage micrometer (0.1 µm graduation) |
| Particle Segmentation Speed | <1 s per field |
| Segmentation Success Rate | >93% |
| Detection Resolution | >95% (per ChP 2020), <10% false-negative rate (per USP <788>, ISO 21501) |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Software Platform | Windows 2000/XP-compatible proprietary image analysis suite |
| Interface | RS-232 or USB 2.0 |
| Compliance | USP <788>, <789>, EP 6.0–8.0, JP 14–16, BP 2009–2013, IP 2010, IntPh V, ChP 2015 & 2020, GB/T 11446.9–2013, GB 8368, ISO 21501-4, ISO 21510, ISO 11171 |
| Brand | PULUODY |
|---|---|
| Model | PLD-MPCS2.0 |
| Origin | Shaanxi, China |
| Microscope Magnification | 40×–1000× |
| Measurement Range | 1–500 µm |
| Resolution | 0.1 µm |
| Repeatability Error | <5% |
| CCD Camera | 3 MP |
| Particle Segmentation Speed | <1 s |
| Segmentation Success Rate | >93% |
| Accuracy | ±3% (typical) |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Resolution Compliance | >95% (ChP 2020), <10% (USP <788>, ISO 21501) |
| Interface | RS232 or USB |
| Software Platform | Windows 2000/XP |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-MPCS2.0-1 |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Digital Image-Based Microscopy with Polarized Light |
| Detection Range | 1–500 µm |
| Magnification | 40×–1000× |
| Maximum Resolution | 0.1 µm |
| Microscope Accuracy | ±0.02 µm (excluding sample preparation variability) |
| Repeatability Error | < 5% (excluding sample preparation variability) |
| Camera | ≥5 MP CCD sensor |
| Calibration Scale | 0.1 µm per pixel |
| Particle Segmentation Speed | < 1 s per image |
| Segmentation Success Rate | > 93% |
| Software Platform | Windows 2000/XP |
| Interface | RS-232 or USB |
| Compliance | ISO 16232, ISO 4406, VDA 19, GME 7061, GMW 16037, JB/T 7858, GB/T 3821, DL 432 |