- All
- Favorite
- Popular
- Most rated
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Chamber Type | Dual-Zone (Hot/Cold Separate Chambers) |
| Temperature Range (Hot) | +60°C to +200°C |
| Temperature Range (Cold) | −78°C to 0°C |
| Thermal Shock Range | −55°C to +125°C |
| Temperature Stability | ±0.5°C |
| Heating Rate | +60°C → +200°C (typical ramp) |
| Cooling Rate | +20°C → −75°C (typical ramp) |
| Compliance | Designed to meet GB/T 2423.22–2025, ISO 16750-4, ASTM D5229/D5229M, MIL-STD-810H Method 503.6 |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | ZJ-YW Series |
| Compliance | ASTM B117, ISO 9227, GB/T 10125-2021 |
| Salt Solution | 5% NaCl (automatically prepared) |
| Salt Spray Rate | 1–2 mL/h·cm² |
| Test Temperature | 35°C ± 2°C (standard neutral salt spray) |
| Extended Operation | Up to 5000 hours continuous |
| Control System | Industrial PLC with HMI touchscreen interface |
| Data Logging | Automatic timestamped storage of chamber temperature, humidity, spray rate, and test duration |
| Reporting | Exportable PDF/CSV test reports with audit trail capability |
| Optional Modes | Salt Spray + Elevated Temperature (e.g., 50°C), Dry-Wet Cycling Simulation |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Type | Domestic Environmental Test Chamber |
| Model | JH-TSC Series |
| Price Range | USD 750 – 75,000 (FOB Shanghai) |
| High-Temperature Range | +60 °C to +200 °C |
| Low-Temperature Range | −78 °C to 0 °C |
| Thermal Shock Range | −55 °C to +125 °C |
| Temperature Stability | ±0.5 °C |
| Heating Rate | +60 °C → +200 °C (typical ramp under no-load conditions) |
| Cooling Rate | +20 °C → −75 °C (typical ramp under no-load conditions) |
| Origin | Heilongjiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JH-9055A / JH-9105A / JH-9205A |
| Power Supply | 220 V / 50 Hz or 380 V / 50 Hz |
| Temperature Range | 100–500 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±1 °C |
| Internal Dimensions (W×D×H) | 350×350×400 mm / 450×450×450 mm / 600×600×600 mm |
| Chamber Volume | 50 L / 100 L / 250 L |
| Input Power | 2800 W / 4800 W / 6000 W |
| Operating Ambient Temperature | +5 to +40 °C |
| Timer Range | 1–9999 min |
| Standard Shelving | 2 adjustable stainless steel trays |
| Test Port | Ø50 mm on left side |
| Control Interface | PID-based digital controller with RS485 and 4–20 mA analog output (optional) |
| Safety System | Independent over-temperature cut-off (optional) |
| Brand | Jianhu |
|---|---|
| Model | JH-B4C |
| Chamber Type | Two-Zone Horizontal Thermal Shock Chamber |
| Internal Dimensions (W×D×H) | 500 × 400 × 400 mm |
| High-Temperature Zone Range | +60 °C to +150 °C |
| Low-Temperature Zone Range | –10 °C to –65 °C |
| Temperature Transition Time (–55 °C ↔ +150 °C) | ≤15 s |
| Control System | PID-based Touchscreen Color LCD Controller |
| Compliance | Meets ASTM D5229, ISO 16750-4, MIL-STD-810H Method 503.5, GB/T 2423.22 |
| Third-Party Calibration | Verified by Shanghai Institute of Measurement and Testing Technology (SIMT) |
| CNAS Lab Deployment | Installed in >500 accredited laboratories nationwide |
| Sample Mounting | Static test specimen configuration with external wiring ports |
| Brand | JH Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JH-Professional Environmental Test Chamber |
| Temperature Range | -80°C to +150°C |
| Thermal Shock Range | -40°C to +150°C |
| Temperature Stability | ±0.5°C to ±2.0°C |
| Heating Rate | 1–3°C/min |
| Cooling Rate | ≤2°C/min |
| Humidity Range | 20–98% RH |
| Humidity Control Accuracy | ±2% RH |
| Temperature Uniformity | ±2°C |
| Compliance | ISO 16750-4, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, ASTM D4332, MIL-STD-810H (Section 501.7, 502.7) |
| Brand | Jianhu |
|---|---|
| Model | LS Series |
| Temperature Range | -65°C to +150°C |
| Chamber Configuration | Three-Zone (Hot Zone / Cold Zone / Test Zone) |
| Control System | 7.5" TFT Color Touchscreen with PID Algorithm |
| Compliance | GB/T 2423.22, GJB 150.5, IEC 60068-2-14, MIL-STD-810H, QC/T 17, EIA-364-32 |
| Refrigeration | Dual-Stage Mechanical Refrigeration with R-507/R-23 Eco-Friendly Refrigerants |
| Communication Interface | RS-232 & RS-485 |
| Safety Features | Dual Independent Over-Temp Protection, Compressor High-Pressure/Low-Pressure Cutouts, Air Pressure Monitoring, Leakage Circuit Breaker, PT100 Sensor Redundancy |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JH Thermal Shock Test Chamber |
| Pricing | Available Upon Request |
| High-Temperature Range (°C) | Customizable per application requirements |
| Low-Temperature Range (°C) | Customizable per application requirements |
| Thermal Shock Range (°C) | Configurable based on chamber design |
| Temperature Stability (°C) | ±0.5 °C typical (subject to calibration and load conditions) |
| Heating Rate (°C/min) | Up to 30 °C/min (standard configuration) |
| Cooling Rate (°C/min) | Up to 25 °C/min (standard configuration) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | NJ-CTH Series |
| Temperature Range | -60°C to +150°C |
| Ramp Rate | Up to 15°C/min |
| Temperature Control Accuracy | ±0.5°C |
| Programmable Steps | ≥100 segments |
| Compliance | ISO 16750-4, GB/T 2423.22, IEC 60068-2-14 |
| Data Logging | Real-time curve display & auto-storage |
| Repeatability | ≤1.5% deviation |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH Thermal Shock Test Chamber |
| Temperature Range (High) | Consult for specification |
| Temperature Range (Low) | Consult for specification |
| Transfer Time | Standardized rapid basket transfer (< 10 s typical) |
| Control System | PID-based digital temperature controller with dual-sensor feedback |
| Construction | Stainless steel inner chamber, high-density polyurethane insulation, reinforced structural frame |
| Compliance | Designed to support ASTM D5229, ISO 11357-6, MIL-STD-810H Method 503.5, IEC 60068-2-14, GB/T 2423.22 |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JH-Multi-Zone Thermal Shock Test Chamber |
| Quotation | Available Upon Request |
| High-Temperature Range | 80 °C to 120 °C |
| Low-Temperature Range | –60 °C to 200 °C (Ultra-Wide Range) |
| Thermal Shock Temperature Range | –55 °C to 125 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Uniformity | ±0.5 °C |
| Heating Rate | Rapid |
| Cooling Rate | Rapid |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor & OEM Integrator |
| Product Category | Domestic (PRC-Made) |
| Model | JH-TSC Series (2025–2026 Selection Guide Edition) |
| Price Range | USD 850 – 8,500 (FOB Shanghai) |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-Thermal Shock Test Chamber |
| Temperature Range (High) | Consult Technical Support |
| Temperature Range (Low) | Consult Technical Support |
| Thermal Shock Transition Time | Typically < 15 s (typical for three-zone industrial configurations) |
| Compliance | Designed to meet ISO 16750-4, MIL-STD-810H Method 503.5, IEC 60068-2-14, ASTM D6988, and GB/T 2423.22 |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-TS Series |
| Temperature Range | -60°C to +180°C |
| Control Accuracy | ±0.5°C |
| Touch Interface | 7-inch capacitive touchscreen with multi-touch support and programmable cycling |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.3, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-30 |
| Application Scope | Reliability validation of electronic components (e.g., automotive ICs, sensors), photovoltaic modules, PCB assemblies, and encapsulated optoelectronic devices |
| Data Logging | Real-time parameter display, automatic storage of cycle logs and alarm events |
| Structural Design | Dual-chamber thermal shock architecture with forced-air circulation and rapid transition (<15 s between chambers) |
| Humidity Capability (for combined aging variant) | 40–90% RH, UV irradiance 0.8–1.2 W/m² (340 nm) |
| Software | Embedded control firmware with audit-trail-ready event logging (GLP-compliant metadata tagging) |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-Series |
| Temperature Uniformity | ±0.5 °C |
| High-Temperature Range | +80 °C to +120 °C |
| Low-Temperature Range | −55 °C to +125 °C |
| Thermal Shock Range | −60 °C to +200 °C |
| Temperature Stability | ±0.5 °C (uniformity across working volume) |
| Heating Rate | Rapid |
| Cooling Rate | Rapid |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-TSC Series |
| Temperature Range | -60°C to +150°C |
| Temperature Transition Rate | Up to 20°C/min |
| Temperature Uniformity | ±2°C |
| Control Accuracy | ±0.1°C |
| Programmable Cycles | Up to 1000 segments |
| Compliance | AEC-Q100, JEDEC JESD22-A104, ISO 16750-4, IEC 60068-2-14 |
| Configuration | Three-zone (Hot / Cold / Test) design with platinum RTD sensors |
| Sample Compatibility | Miniaturized semiconductor packages (e.g., QFN, BGA, WLCSP), display modules (OLED/LCD), MEMS devices |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | LS-A3C |
| Internal Chamber Dimensions (W×D×H) | 40×35×30 cm |
| High-Temperature Zone Range | +60 °C to +150 °C |
| Low-Temperature Zone Range | −10 °C to −55 °C |
| Thermal Shock Range Options | −40 °C to +150 °C or −55 °C to +150 °C |
| Transition Time (Hot ↔ Cold) | ≤10 s |
| Cycle Count Setting Range | 1–999 cycles |
| Soak Time per Zone | Programmable up to 999 h 59 min |
| Control Interface | Color TFT LCD Touchscreen Controller with English/Chinese UI |
| Compliance | GJB 150.3-1986, GJB 150.4-1986, GJB 150.5-1986 |
| Configuration | Three-chamber (separate hot chamber, cold chamber, and test chamber) with pneumatic thermal airflow switching |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-Series |
| Temperature Range (High) | +60°C to +200°C |
| Temperature Range (Low) | −70°C to 0°C |
| Thermal Shock Range | −60°C to +150°C |
| Temperature Stability | ±0.5°C to ±2.0°C |
| Heating Rate | 3–20°C/min |
| Cooling Rate | 3–15°C/min |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic |
| Model | JH-TSC Series |
| Price Range | USD 170 – 1,700 |
| High-Temperature Range (°C) | +150 |
| Low-Temperature Range (°C) | -70 |
| Thermal Shock Range (°C) | -70 to +150 |
| Temperature Stability (°C) | ±0.5 |
| Ramp-Up Rate (°C/min) | ≥10 |
| Ramp-Down Rate (°C/min) | ≥10 |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH Thermal Shock Test Chamber |
| Temperature Range | Consult for High/Low/Temperature Transition Specifications |
| Temperature Stability | ±0.5 °C (typical for industrial-grade dual-zone chambers) |
| Ramp Rate | ≥10 °C/min (typical for air-based two-chamber systems) |
| Configuration | Dual-Chamber (Hot/Cold) with Static Test Zone |
| Compliance | Designed to meet ASTM D5229, ISO 16750-4, MIL-STD-810H Method 503.5, IEC 60068-2-14, GB/T 2423.22 |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-Tri-Chamber |
| Temperature Range (High) | Up to +150 °C |
| Temperature Range (Low) | Down to −60 °C |
| Transfer Time (Hot → Cold) | ≤ 15 s |
| Temperature Uniformity in Test Chamber | ±0.5 °C |
| Control Accuracy | ±0.3 °C |
| Compliance | ISO 16750-4, ASTM D5229/D5229M, MIL-STD-810H Method 503.5, IEC 60068-2-14 |
| Cooling Method | Dual-mode (forced-air + optional liquid nitrogen) |
| Heating Method | High-efficiency tubular heaters |
| Chamber Configuration | Independent high-temp, low-temp, and test chambers |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | DV-TC2 |
| High Temperature Range | +60°C to +200°C |
| Low Temperature Range | −78°C to 0°C |
| Thermal Shock Range | −55°C to +125°C |
| Temperature Stability | ±0.5°C |
| Heating Rate | +60°C → +200°C (typical) |
| Cooling Rate | +20°C → −75°C (typical) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model(s) | LS-A3C, LS-B3C, LS-C3C |
| Internal Dimensions (W×D×H) | 40×35×30 cm (LS-A3C), 50×40×40 cm (LS-B3C), 60×50×50 cm (LS-C3C) |
| Temperature Range | High Zone: +60°C to +150°C |
| Low Zone | −10°C to −65°C |
| Transfer Time (Hot ↔ Cold) | ≤15 s |
| Temperature Recovery Time | ≤5 min |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2008, GB 10592–2008, GJB 150.3A–2009 |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-TSC-3C |
| Temperature Range | -55 °C to +180 °C |
| Temperature Transition Rate | ≥20 °C/min (typical, 70 °C ↔ 10 °C in ≤5 min) |
| Temperature Uniformity | ±0.3 °C within test zone |
| Programmable Cycles | Up to 1000 segments per profile |
| Compliance | Designed to support ISO 16750-4, IEC 60068-2-14, MIL-STD-883H Method 1010, SAE J1211, and IEC 62108 testing protocols |
| Control Precision | ±0.3 °C setpoint stability |
| Cooling Method | Liquid nitrogen direct injection + cascade refrigeration |
| Heating Method | High-frequency alloy heating elements |
| Chamber Architecture | Triple-chamber (separate high-temp, low-temp, and test chambers) |
| Data Logging | Real-time temperature traceability with audit trail capability |
Show next