PULUODY
Filter
Showing 121–150 of 412 results
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0203-3 |
| Price | USD 27,800 (approx.) |
| Compliance | ISO 4406, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Calibration Standards | JJG 1061, ISO 11171, ASTM F658-87 (PSL), GB/T 18854 |
| Detection Principle | Light Obscuration (LO) |
| Laser Source | 7th-generation dual-laser narrow-beam sensor |
| Measurement Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 resolution channels |
| Sensitivity | 1 µm (ISO 4402) / 4 µm(c) (ISO 11171, GB/T 18854) |
| Accuracy | < ±3% |
| Sample Volume Precision | ±1% |
| Max. Online Pressure | 31.5 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Flow Rate | Sampling 5–60 mL/min |
| Operating Temp. | Sample 20–65°C |
| Power | 220 VAC, 50 Hz, <80 W |
| Data Storage | Up to 6000 test records |
| Output Interfaces | RS232, RS485, USB, 4–20 mA, 0–5 V, MODBUS |
| Regulatory Certification | CALIBRATED by NW National Metrology Center (civil) or CMC Level-1 Particle Metrology Station (defense) |
| Brand | PULUODY |
|---|---|
| Model | PLD-0221A |
| Power Supply | AC 220 V |
| Power Consumption | 1750 W |
| Temperature Control Range | 15 °C to 20 °C |
| Temperature Stability | ±0.2 °C |
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Key | Brand: PULUODY |
|---|---|
| Model | PLD-0248A |
| Origin | Shaanxi, China |
| Manufacturer | Yes |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Input Power | <1250 W |
| Cooling Range | Ambient to –40 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Power | 400 W |
| Refrigerant | Anhydrous Ethanol |
| Filtration Pressure | 1961 Pa (200 mmH₂O) |
| Filter Mesh | 363 mesh (≈40 µm nominal aperture) |
| Standard Compliance | SH/T 0248 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-0248B |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Input Power | <1250 W |
| Cooling Bath Temperature Range | Ambient to –40 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Power | 400 W |
| Refrigerant | Anhydrous Ethanol |
| Refrigeration System | Cascade Compressor-Based |
| Brand | PULUODY |
|---|---|
| Model | PLD-11132A |
| Standard Compliance | GB/T 11132 |
| Measurement Principle | Fluorescent Indicator Adsorption (FIA) Chromatography |
| Capillary Adsorption Column | Conforms to GB/T 11132 specifications |
| Fluorescent Indicator | Imported silica gel impregnated with fluorescent dye or fluorescent indicator solution |
| Silica Gel Mesh Size | 100–200 mesh |
| Electric Oscillator | Frequency 100 Hz ± 2 Hz, Amplitude > 1.5 mm |
| UV Light Source | 365 nm ± 5 nm (3650 Å ± 50 Å) |
| Structural Frame | Stainless steel square tubing, mobile and modular |
| Pressure Regulation | Adjustable per test requirements |
| Power Supply | AC 220 V, 50 Hz |
| Operating Environment | 10–30 °C, ≤80% RH |
| Sample Compatibility | Liquid petroleum products including gasoline, naphtha, kerosene, and diesel fractions |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | PLD-11132A |
| Pricing | Upon Request |
| Capillary Adsorption Column | Compliant with GB/T 11132 |
| Fluorescent Indicator | Imported silica gel or solution pre-impregnated with fluorescent dye |
| Silica Gel Mesh Size | 100–200 mesh |
| Oscillator Frequency | 100 Hz ± 2 Hz, Amplitude > 1.5 mm |
| UV Light Source Wavelength | 365 nm ± 5 nm |
| Structural Frame | Stainless steel square tubing, modular and mobile |
| Pressure Regulation | Adjustable per test requirement |
| Power Supply | AC 220 V, 50 Hz |
| Operating Environment | 10–30 °C, ≤80% RH |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | PLD-11143A |
| Pricing | Upon Request |
| Power Supply | 220 V ±10%, 50 Hz |
| Temperature Control Range | 0–100 °C |
| Temperature Display | Digital |
| Timing Range | 1 min – 24 h |
| Timer Display | Digital |
| Main Heating Power | 600 W / 220 V |
| Auxiliary Heating Power | 1000 W / 220 V |
| Temperature Control Accuracy | ±1.0 °C |
| Stirrer Speed | 1000 ±50 rpm |
| Test Stations | 4 |
| Ambient Operating Temperature | ~25 °C |
| Relative Humidity | ≤85% |
| Rust Specimen Polishing Unit Power | AC 220 V ±20 V, 90 W |
| Polishing Motor Speed | 1750 ±50 rpm |
| Brand | PULUODY |
|---|---|
| Model | PLD-11143B |
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Control Range | 0–100 °C |
| Temperature Accuracy | ±1.0 °C |
| Temperature Display | Digital |
| Timing Range | 1 min – 24 h |
| Time Display | Digital |
| Main Heating Power | 600 W / 220 V |
| Auxiliary Heating Power | 1000 W / 220 V |
| Stirrer Speed | 1000 ±50 rpm |
| Test Stations | 4 |
| Ambient Operating Temperature | ~25 °C |
| Relative Humidity | ≤85% |
| Rust Specimen Polishing Motor | AC 220 V ±20 V, 90 W, 1750 ±50 rpm |
| Construction | Stainless Steel Water Bath Chamber, Precision Electromechanical Drive System, Dual-Zone Thermal Regulation |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-11901 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Filtration Pore Size | 0.45 µm |
| Filter Diameter | φ50 mm or φ60 mm |
| Drying Temperature Control | 104 ± 1 °C |
| Gravimetric Accuracy | ≥0.1 mg |
| Maximum Vacuum Pressure | ≥80 kPa |
| Vacuum Adjustment Range | 20–80 kPa |
| Airflow Rate | ≥20 L/min |
| Acoustic Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Detection Limit | 2 mg/L |
| Recommended Sample Mass Range | 5–100 mg (corresponding to 100 mL sample volume at typical concentrations) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-11901 |
| Instrument Type | Portable Suspended Solids Analyzer |
| Detection Principle | Gravimetric Filtration (0.45 µm membrane) |
| Filtration Membrane | Glass fiber or quantitative filter paper (φ50 mm or φ60 mm, pore size 0.45 µm) |
| Drying Temperature | 104 ± 1 °C |
| Weighing Accuracy | ≥ 0.1 mg |
| Vacuum Pressure Range | 20–80 kPa |
| Maximum Vacuum | ≥ 80 kPa |
| Airflow Rate | ≥ 20 L/min |
| Noise Level | ≤ 60 dB(A) |
| Power Supply | AC 220 V ± 10%, 50 Hz |
| Detection Range | 2–1000 mg/L (practical optimal range: 5–100 mg suspended solids per sample) |
| Sample Volume | 100 mL (adjustable based on expected concentration) |
| Compliance Basis | ASTM D5907, ISO 11923, EPA Method 160.2, GB/T 11901–1989 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PLD-11901 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameter | Suspended Solids (SS) in Surface Water, Groundwater, Domestic Wastewater, and Industrial Effluents |
| Filtration Pore Size | 0.45 µm |
| Filter Diameter | φ50 mm or φ60 mm |
| Drying Temperature Range | 103–105 °C |
| Weight Precision | ≥0.1 mg |
| Maximum Vacuum Pressure | ≥80 kPa |
| Vacuum Adjustment Range | 20–80 kPa |
| Airflow Rate | ≥20 L/min |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Detection Limit | 2 mg/L |
| Gravimetric Accuracy Endpoint | ≤0.4 mg mass difference between consecutive weighings |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-12579A |
| Input Power | 2300 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Control Range | 24 °C (low) to 93.5 °C (high) |
| Temperature Stability | ±0.5 °C |
| Stirring Motor Power | 25 W |
| Adjustable Temperature Setpoint Range | 0–99.9 °C |
| Timer Range | 0–99.99 hours |
| Portable Chiller Power | 200 W |
| Air Flow Rate | 16–160 mL/min |
| Brand | PULUODY |
|---|---|
| Model | PLD-1884B |
| Temperature Control Range | 5–80 °C |
| Temperature Stability | ±0.2 °C |
| Heating Power | 600 W |
| Input Power | <1000 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Construction | Stainless Steel Bath with Optical Clarity |
| Cooling System | Imported Hermetic Compressor |
| Circulation | Magnetic Drive Circulating Pump |
| Compliance | GB/T 1884, ASTM D1298, ISO 3675 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PLD-1885A |
| Instrument Type | True Density Calculator |
| Form Factor | Portable |
| Sample Type | Liquid |
| Density Measurement Range | 0.0005 g/mL |
| Density Accuracy | ±0.0005 g/mL |
| Compliance Standard | GB/T 1885–1998 “Petroleum Measurement Tables” |
| Application Scope | Crude oil, gasoline, diesel, lubricating oils, water content (mₛ) and net oil mass (m꜀) calculation |
| Temperature Range | –55 °C to +50 °C |
| Power Supply | Rechargeable battery or 220 V AC adapter |
| Brand | PULUODY |
|---|---|
| Model | PLD-1885B |
| Origin | Shaanxi, China |
| Power Supply | AC 220 V, 50 Hz or 4 × AAA batteries (1.5 V each) |
| Dimensions | 195 mm × 100 mm × 45 mm |
| Interface | USB 2.0 |
| Accuracy | ±0.0005 g/mL |
| Operating Temperature Range | User-defined (theoretical input range unrestricted |
| Compliance | GB/T 1884–2000, GB/T 1885–1998, GB/T 11139–1989 |
| Application Databases | Crude oil, petroleum products, lubricating oils, and distillate fuel cetane index |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | PLD-201 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Measurement Range | 0.01 µm – 1000 µm (sensor-dependent, up to 1000 channels) |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Sample Flow Control | Precision Piston Pump + Ultra-Precise Electromagnetic Flow Regulation |
| Calibration Standards | ISO 11171, ISO 4402, ISO 4406, NAS 1638, GB/T 14039, GJB 420A/B, DL/T 432, JJG/T 066 |
| Compliance | Meets GLP-relevant data integrity requirements |
| Software | PULL 8.1 Multi-Language Analysis Platform (English, Chinese, Japanese, Korean, etc.), 3000-test onboard storage, RS232 interface, touchscreen GUI with dual input (touch + keypad), integrated thermal printer |
| Operating Temperature | 0–50 °C |
| Sample Viscosity Limit | ≤450 mm²/s |
| Pressure Range | −0.08 to 0.8 MPa |
| Sampling Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (test), 10–100 mL/min (cleaning) |
| Repeatability | ≤5% coincidence error at 10,000 particles/mL |
| Data Output | Particle count per mL, contamination grade (ISO/NAS), histogram, cumulative distribution, raw pulse data |
| Brand | PULUODY |
|---|---|
| Model | PLD-259A |
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Rated Power | 500 W |
| Operating Voltage | 220 V AC, 50 Hz |
| Temperature Control Range | TR+10 °C to 100 °C |
| Temperature Display Accuracy | ±0.2 °C |
| Separatory Funnel Capacity | 250 mL |
| Graduated Cylinders | 50 mL and 100 mL |
| Test Tube Diameter Compatibility | φ15–20 mm |
| pH Measurement Range | 0.00–14.00 |
| pH Accuracy | ±0.1 pH |
| mV Range | ±1999 mV |
| mV Accuracy | ±10 mV |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PLD-260G |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Measurement Range | 1 µg – 500 mg H₂O |
| Sensitivity | 0.1 µg |
| Accuracy | ±5% ±1 µg |
| Electrode System | Dual Platinum Indicator Electrodes |
| Titration Cell Volume | 150 mL |
| Stirring Method | Magnetic Stirring |
| Control System | PULL T 8.0 Embedded Test Platform |
| Analysis Time per Sample | 2–4 min |
| Endpoint Detection | Real-time Current Monitoring with Audio-Visual Alert |
| Display | 20×2 Character LCD (Date, Time, Electrolysis Rate, µg H₂O) |
| Printer Output | 16-Character Thermal Printer |
| Power Supply | 220 V ±10%, 50 Hz ±0.5 Hz |
| Power Consumption | 40 W |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤70% RH |
| Compliance Standards | GB/T 7600, GB/T 11133, GB/T 6283, SH/T 0207, SH/T 0246, SH/T 0255 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PLD-261A |
| Detection Method | Closed Cup (Tagliabue Cleveland Open Cup not applicable) |
| Standards Compliance | GB/T 261, ASTM D93 |
| Input Power | 1250 W |
| Supply Voltage | AC 220 V ±10%, 50 Hz |
| Max. Heating Power | 0–1200 W (continuously adjustable) |
| Ignition Gas Source | Coal gas, butane, or LPG |
| Stirring Motor | 6 W, 105 rpm |
| Stirring Speed | 105 rpm |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-261D |
| Price | USD 7,800 (FOB) |
| Brand | PULUODY |
|---|---|
| Model | PLD-265B |
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Power Input | <1850 W |
| Supply Voltage | AC 220 V ±10%, 50 Hz |
| Main Heating Power | 1000 W |
| Auxiliary Heating Power | 800 W |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Capillary Type | Ubbelohde (Ostwald-type) viscometer |
| Number of Capillary Holders | 4 |
| Conformance | GB/T 265–1988 (equivalent to ASTM D445 and ISO 3104) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PLD-265H |
| Power Input | <1850 W |
| Supply Voltage | AC 220 V ±10%, 50 Hz |
| Main Heating Power | 1000 W |
| Auxiliary Heating Power | 800 W |
| Temperature Control Range | 40–100 °C |
| Temperature Stability | ±0.1 °C |
| Capillary Type | Ubbelohde (Ostwald-type) viscometer |
| Number of Capillary Holders | 4 |
| Compliance Standard | GB/T 265 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-265I |
| Power Supply | 220 V ±10%, 50 Hz |
| Heating Power | 1.8 kW |
| Stirring Motor | 15 W, 1400 rpm |
| Illumination | 9 W energy-saving fluorescent lamp |
| Temperature Control | Microcontroller-based digital display controller |
| Temperature Range | −38 °C to ambient |
| Temperature Stability | ±0.1 °C |
| Test Positions | 2 |
| Ambient Operating Conditions | 5–35 °C, <85% RH |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-268A |
| Ceramic Crucible | Low-form, 30 mL |
| Inner Iron Crucible | Galvanized steel, 75 ± 5 mL with lid |
| Outer Iron Crucible | Galvanized steel, 190 ± 10 mL with lid |
| Tripod Stand | Stainless steel, height 250 ± 10 mm, ring diameter Φ130 ± 5 mm |
| Flame Shield | Stainless steel, conical bore — top opening Φ90 ± 2 mm, bottom opening Φ82 ± 2 mm |
| Stainless Steel Cover | Lower cylindrical section height 50–53 mm |
| Gas Burner | Metric-pattern gas blowpipe (Conradson-type) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-268A |
| Ceramic Crucible | Low-form, 30 mL |
| Inner Iron Crucible | Galvanized steel, 75 ± 5 mL with lid |
| Outer Iron Crucible | Galvanized steel, 190 ± 10 mL with lid |
| Tripod Stand | Stainless steel, height 250 ± 10 mm, ring diameter Φ130 ± 5 mm |
| Flame Shield | Stainless steel, conical bore—top opening Φ90 ± 2 mm, bottom opening Φ82 ± 2 mm |
| Stainless Steel Cover | Lower cylindrical section height 50–53 mm |
| Gas Burner | Metric-pattern gas blowtorch (Conradson-type) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PLD-269C |
| Pricing | Available Upon Request |
| Maximum Penetration Range | 75 mm |
| Penetration Resolution | ±0.1 mm |
| Timing Accuracy | 0.1 s |
| Standard Cone | Compliant with GB/T 269 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-3535A |
| Input Power | < 800 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Control Range | Ambient to –35 °C |
| Temperature Control Accuracy | ±1 °C |
| Cooling Time | ≤ 100 min |
| Cold Bath Dimensions | 200 × 90 × 120 mm |
| Bath Configuration | Dual-Position Single Bath (1 pour point station + 1 cloud point station) |
| Compliance | GB/T 3535, GB/T 6986 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-3535D |
| Temperature Range | 60 °C to −38 °C |
| Temperature Resolution | 0.1 °C |
| Sample Channels | 2 |
| Cooling Method | Air-Cooled Compressor System |
| Detection Method | Top-Mounted Photoelectric Liquid-Level Sensor with Micro-Tilt Mechanism |
| Temperature Interval Setting | 1–10 °C (user-defined) |
| Power Supply | AC 220 V ±10%, 50 Hz ±2 Hz |
| Display | 128×64 Dot-Matrix LCD (Chinese Characters) |
| Printer | 20-Column Dot-Matrix Thermal Printer (Chinese Characters) |
| Compliance Standard | GB/T 510 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | PLD-3535E |
| Power Input | <1600 W |
| Supply Voltage | AC 220 V ±10%, 50 Hz |
| Temperature Control Method | Microcontroller-Based Digital PID Control |
| Temperature Range | +30 °C to –38 °C |
| Temperature Stability | ±0.5 °C |
| Cooling Time (30 °C → –38 °C) | ≤100 min |
| Bath Configuration | Dual-Position Single-Bath Design |
| Compliance Standards | GB/T 3535, GB/T 510, GB/T 6986, SH/T 0248, ASTM D97, ASTM D2500, ASTM D5853, ASTM D6371 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-3535E-2 |
| Input Voltage | AC 200 V ±10%, 50 Hz |
| Power Consumption | 2000 W |
| Temperature Control Range | +50 °C to –70 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Detection Method | Optical Liquid Surface Detection |
| Test Bath Configuration | Dual independent 2-hole cold baths |
| Tube Tilt Angles | 45° and 90° (motorized mechanical actuation) |
| Temperature Step Interval | 2 °C, 3 °C or user-defined |
| Display | 7″ capacitive touch LCD panel |
| Printer | Built-in thermal printer |
| Ambient Operating Conditions | 5–35 °C, <85% RH (non-condensing) |