| Brand | PULUODY |
|---|---|
| Model | PLD-3535E+ |
| Standard Compliance | ASTM D5950-14, GB/T 3535 |
| Temperature Control Range | 50 °C to –70 °C |
| Control Accuracy | ±0.1 °C |
| Tilt Angles | 45° and 90° (motorized) |
| Temperature Interval | 2 °C, 3 °C or user-defined |
| Power Supply | AC 200 V ±10%, 50 Hz, 2000 W |
| Display | 7″ capacitive touchscreen |
| Operating Environment | 5–35 °C, <85% RH |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-3536A |
| Detection Method | Cleveland Open Cup (COC) |
| Input Power | 1250 W |
| Power Supply | AC 220 V / 50 Hz |
| Fuel Gas Options | Coal gas, butane, hydrogen, or LPG |
| Test Flame Ball Radius | 150 mm |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PLD-3536D |
| Detection Method | Cleveland Open-Cup (COC) |
| Standards Compliance | GB/T 3536–2008, ASTM D92, ISO 2592 |
| Temperature Range | Ambient to 400 °C |
| Ignition Modes | Dual-mode (electronic spark + gas flame, selectable individually or simultaneously) |
| Control System | Dual-core CPU microcontroller |
| Display | 4.0-inch TFT LCD with touch-sensitive keypad |
| Cooling Method | Forced-air cooling |
| Atmospheric Pressure Compensation | Integrated digital barometric sensor with automatic calibration |
| Data Output | Thermal printer (built-in) |
| Software | PV Flash Point (Open) Test v8.0 |
| Flash Point Detector | PULL proprietary open-cup flash sensor |
| Power Supply | AC 220 V ±20 V, 50 Hz ±5 Hz |
| Rated Power | 500 W |
| Dimensions (W×D×H) | 310 × 395 × 303 mm |
| Safety Features | Auto-extinguishing, real-time fault diagnosis, thermal runaway protection, end-of-test forced cooldown |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PLD-3536D |
| Detection Method | Cleveland Open-Cup (COC) |
| Standards Compliance | GB/T 3536–2008, ASTM D92, ISO 2592 |
| Temperature Range | Ambient to 400 °C |
| Ignition Modes | Dual-mode (electronic spark + gas flame, selectable individually or jointly) |
| Display | 4.0-inch TFT LCD with touch keypad |
| Cooling | Forced-air cooling |
| Atmospheric Pressure Compensation | Integrated digital barometric sensor with auto-calibration |
| Power Supply | AC 220 V ±20 V, 50 Hz ±5 Hz |
| Power Consumption | 500 W |
| Dimensions | 310 × 395 × 303 mm |
| Data Output | Thermal printer (built-in) |
| Control System | Dual-core microprocessor-based embedded controller |
| Software | PV Flash Point (Open) Test v8.0 |
| Safety Features | Auto-extinguishing after test completion, real-time fault diagnosis, overtemperature & flame-out protection, self-diagnostics |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | PLD-380C |
| Pricing | Upon Request |
| Standard Compliance | GB/T 380 |
| Sample Type | Light petroleum products with Reid Vapor Pressure ≤ 80 kPa |
| Lamp Holder Capacity | 7 parallel sample positions |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Optical Viewing | Transparent acrylic mounting platform for unobstructed visual monitoring |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-4929A |
| Heating Power | 0–300 W (continuously adjustable) |
| Stirring Speed | 375 rpm |
| Supply Voltage | AC 220 V, 50 Hz |
| Illumination Lamp | 7 W |
| Oil Bath Capacity (Inner) | 600 mL |
| Compliance | GB/T 4929, ISO 2176, ASTM D566 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-508A |
| Heating Power | 4000 W |
| Rated Voltage | AC 220 V / 50 Hz |
| Furnace Chamber Dimensions | 300 × 200 × 120 mm |
| Filter Paper Diameter | 9 cm |
| Porcelain Crucible Capacity | 50 mL |
| Temperature Range | Ambient to 1000 °C |
| Control Method | Analog Pointer-Based Temperature Controller with Integrated Ammeter |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PLD-508A |
| Heating Power | 4000 W |
| Rated Voltage | AC 220 V / 50 Hz |
| Furnace Chamber Dimensions | 300 × 200 × 120 mm |
| Filter Paper Diameter | 9 cm |
| Porcelain Crucible Capacity | 50 mL |
| Temperature Range | Ambient to 1000 °C |
| Control System | Analog Pointer-Based Temperature Controller with Integrated Ammeter |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PLD-5096A |
| Pricing | Upon Request |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.5 °C |
| Heating Power | Main Heating 1000 W, Auxiliary Heating 800 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | PULUODY |
|---|---|
| Model | PLD-5096B |
| Standard Compliance | GB/T 5096, ASTM D130, SH/T 0023 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.5 °C |
| Heating Power | Main Heater 1000 W + Auxiliary Heater 800 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Construction | Stainless Steel Bath Vessel, Platinum RTD Sensor, Integrated Condenser System |
| Sample Capacity | 2 Test Bombs + 6 Copper Strip Tubes (or 2 Silver Strip Tube Sets) |
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Producer |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-509A |
| Pricing | Available Upon Request |
| T-type Delivery Tube Inner Diameter | 6 mm |
| High-form Beaker Capacity (Nozzle-less) | 100 mL |
| Air Flowmeter Range | 10–88 L/min |
| Heating Element Power | 1800 W |
| Input Voltage | AC 220 V, 50 Hz |
| Temperature Control Range | Ambient to 300 °C |
| Temperature Control Accuracy | ≤ ±2.5 °C |
| Operating Ambient Temperature | –10 °C to +45 °C |
| Maximum Relative Humidity | 85 % RH |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-510A |
| Power Input | <800 W |
| Supply Voltage | AC 220 V ±10%, 50 Hz |
| Temperature Control Range | Ambient to –38 °C (Standard) |
| Temperature Stability | ±1 °C |
| Cooling Time to –38 °C | ≤100 min |
| Cold Bath Dimensions | 200 × 90 × 120 mm |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | PLD-510A |
| Power Input | <800 W |
| Supply Voltage | AC 220 V ±10%, 50 Hz |
| Temperature Control Range | Ambient to –38 °C (Standard) |
| Temperature Stability | ±1 °C |
| Cooling Time to –38 °C | ≤100 min |
| Cold Bath Dimensions | 200 × 90 × 120 mm |
| Brand | PULUODY |
|---|---|
| Model | PLD-510C |
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Temperature Range | 60 °C to −38 °C |
| Temperature Resolution | 0.1 °C |
| Sample Channels | 2 |
| Detection Method | Top-mounted photoelectric liquid-level sensor with automated sample tube tilting |
| Cooling System | Mechanical compressor-based refrigeration |
| Cooling Medium | Air-cooled condenser |
| Temperature Differential Control | Programmable ΔT between coolant and sample |
| Tilt Mechanism | Micro-tilt actuation with real-time liquid-level feedback |
| Heating Element | Integrated micro-heater for rapid sample recovery |
| Display | 128×64 dot-matrix LCD (Chinese character support) |
| Printer | 20-column thermal dot-matrix printer (Chinese character support) |
| Power Supply | AC 220 V ±10%, 50 Hz ±2 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | PLD-510C |
| Input Power | <1600 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Control Method | Microcontroller-based digital intelligent control |
| Temperature Range | +30 °C to –68 °C |
| Temperature Stability | ±0.5 °C |
| Cooling Time (30 °C → –68 °C) | ≤100 min |
| Bath Configuration | Dual-sample immersion bath (2-position cold bath槽) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-511A |
| Power Supply | 220 V AC, 50 Hz |
| Input Power | 500 W (Heating: 2 × 100 W) |
| Ultimate Vacuum | ≥0.09 MPa |
| Air Extraction Rate | ≥20 L/min |
| Brand | PULUODY |
|---|---|
| Model | PLD-6001 |
| Origin | Shaanxi, China |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 1–500 µm (optional 0.03–3000 µm) |
| Resolution | >95% (ChP 2015/2020 calibrated) |
| Channel Count | 1000 adjustable channels (user-definable from 4 to 128 size bins) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | <±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Sample Temperature Range | 0–80 °C |
| Environmental Operating Range | −15–50 °C |
| Compliance | ChP 2020 Appendix 0903, USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 21510, GB/T 11446.9–2013, GB 8368, YBB 00272004–2015 |
| Software | V8.9 Particle Analysis Suite (PC & embedded touchscreen), 21 CFR Part 11 compliant with audit trail, electronic signature, role-based 5-level access control, data backup/recovery, and power-fail protection |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, ISO 21501-4 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Laser Source | Dual-narrow-beam laser diode array (8th-generation) |
| Sensor Resolution | 1000 channels, down to 0.01 µm |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Channel Flexibility | User-definable size bins (e.g., 4–70 µm(c), 1–100 µm, or 0.1 µm(c)) |
| Flow Rate Range | Sample: 5–150 mL/min |
| Rinse | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Range | −15–50 °C |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9–2013, YBB00272004–2015, GB 8368 |
| Software | V8.9 Analytical Suite (PC & embedded touchscreen), FDA 21 CFR Part 11 compliant (audit trail, electronic signature, role-based 5-level access, data backup/restore, power-fail recovery) |
| Calibration Standards | NIST-traceable polystyrene latex (PSL) spheres, JJG 1061–2019, ISO 21501-4 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-601 |
| Price | USD 26,500 (FOB) |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 customizable channels (down to 0.01 µm resolution) |
| Flow Accuracy | < ±1% |
| Volumetric Precision | < ±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (CP 2015/2020 calibration), <10% (USP/ISO 21501 calibration) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Temperature | −15–50 °C |
| Compliance | CP 2020 Method 0903, GB 8368, USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, ISO 21501-2, ISO 11171, ASTM D6786, FDA 21 CFR Part 11 (audit trail, e-signature, role-based 5-level access) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-601 |
| Price | USD 29,500 (approx.) |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Particle Sensing |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Regulatory Compliance | ChP 2020 <0903>, USP <788>/<789>, EP 10.0, BP 2019, JP 17, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 21510, ISO 11171 |
| Software | V8.9 Regulatory-Grade Analysis Suite (FDA 21 CFR Part 11 Compliant) |
| Particle Size Range | 1–500 µm (optional extended range: 0.03–3000 µm) |
| Channel Resolution | 1000-user-definable channels (min. bin width: 0.01 µm) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), >90% (ISO 21501-4 calibrated) |
| Data Integrity | Audit Trail, Electronic Signature, Role-Based 5-Tier User Permissions, Auto-Backup/Restore, Power-Fail Recovery |
| Interface | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Sample Compatibility | Aqueous & non-aqueous sterile injectables, lyophilized powders, ophthalmic solutions, vaccines, WFI, pharmaceutical packaging materials, infusion devices, terminal filters, CMP slurries, ultrapure water, electronic-grade chemicals |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-601 |
| Price | USD 32,500 (FOB) |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Particle Sensing |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Regulation |
| Software | V8.9 Regulatory-Compliant Analysis Suite (PC & Touchscreen) |
| Calibration Standards | JJG1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Regulatory Alignment | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21510, GB/T 11446.9-2013, GB 8368 |
| Particle Size Range | 1–500 µm (optional extension: 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (user-definable from 4 to 128 size bins) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020) |
| Resolution | >95% (ChP-calibrated), >90% (ISO 21501-4 calibrated) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Sampling Precision | <±1% volumetric repeatability |
| Data Integrity | 5-Tier User Permission Architecture, Audit Trail, Electronic Signature, Full 21 CFR Part 11 Compliance, Auto-Backup/Restore, Power-Fail Recovery |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601* |
| Sensor | 8th-generation dual-laser narrow-beam particle sensor |
| Detection Principle | Light Blockage (Optical Obstruction) |
| Measurement Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (down to 0.01 µm resolution) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated) |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9-2013, GB 8368, YBB 00272004-2015 |
| Software | V8.9 Regulatory Edition with 5-level user permissions, audit trail, electronic signature, 21 CFR Part 11 compliance, data backup/recovery, and power-fail protection |
| Interface | Touchscreen + optional wireless keyboard/mouse |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, or ISO 21501-4 reference materials |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Resolution | 1000 customizable channels (down to 0.01 µm bin width) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Temperature Range (Fluid) | 0–80 °C |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-2, ISO 11171, GB/T 11446.9–2013, GB 8368, FDA 21 CFR Part 11 (audit trail, e-signature, role-based 5-level access), GLP/GMP-ready software architecture |
| Brand | PULUODY |
|---|---|
| Model | PLD-601 |
| Origin | Shaanxi, China |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Detection Principle | Light Obscuration (LO) per USP <788>, EP 2.9.19, and ChP 0903 |
| Measurement Range | 1–500 µm (optional extension to 0.03–3000 µm) |
| Channel Resolution | 1000 adjustable size channels (down to 0.01 µm resolution) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Accuracy | ±3% typical (per ChP 2020) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | NIST-traceable latex spheres, ISO 21501-4, JJG 1061 |
| Software Compliance | FDA 21 CFR Part 11, ALCOA+ principles, audit trail, electronic signature, 5-level user权限 management |
| Operating Interface | Touchscreen + optional wireless keyboard/mouse |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Range | −15–50 °C |
| Regulatory Alignment | Compliant with ChP 2015/2020, USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 4406, ISO 11171, NAS 1638, SAE AS4059, MIL-STD-1246, ASTM D6786, GB/T 18854, DL/T 432, and more |
| Brand | PULUODY |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PLD-601 |
| Price Range | USD 55,000–69,000 (FOB UK) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Counter |
| Measurement Range | 0.1–800 µm |
| Repeatability | ≥99% |
| Measurement Time | 10–60 s |
| Brand | PULUODY |
|---|---|
| Model | PLD-601 |
| Instrument Type | Optical Particle Counter (Light Obscuration Method) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Sensor Generation | 8th-Generation Dual-Laser Detector |
| Channel Count | 1000 Adjustable Channels (Down to 0.01 µm resolution) |
| Particle Size Range | 1–450 µm (Extended Range: 0.03–3000 µm Optional) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Environmental Operating Range | −15–50 °C |
| Sampling Accuracy | < ±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (Calibrated per ChP 2015/2020), <10% (Calibrated per USP/ISO 21501) |
| Software | V8.9 Integrated PC & Touchscreen Analysis Suite |
| Compliance | FDA 21 CFR Part 11, Annex 11, GLP/GMP Data Integrity Requirements, Audit Trail, Electronic Signature, Five-Tier User Permissions |
| Standards Supported | ChP 0903 (2015 & 2020), USP <788>, <789>, <797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 21501-4, ISO 11171, ISO 4406, NAS 1638, SAE AS4059, MIL-STD-1246, ASTM D6786, GB/T 18854, DL/T 432, GJB/T 420A/B |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-601 |
| Price | USD 34,500 (FOB Shanghai, ex-factory) |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Software Compliance | FDA 21 CFR Part 11, ALCOA+ Data Integrity, Audit Trail, Electronic Signature, 5-Level User Permission Management |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Standards |
| Detection Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 High-Resolution Channels (0.01 µm resolution increment) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range | Fluid 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Repeatability | ≤2.5% coincidence error at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated) |
| Regulatory Alignment | ChP 2020 <0903>, USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 21510, ISO 4406, NAS 1638, ASTM D6786 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Measurement Range | 1–500 µm (optional 0.03–3000 µm) |
| Resolution | >95% (ChP 2015/2020 calibrated) |
| Channel Count | 1000 user-definable channels (down to 0.01 µm bin resolution) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Accuracy | ±3% typical (particle count), ±1% volumetric delivery |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Compliance | ChP 2020 <0903>, USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, GB/T 11446.9–2013, GB 8368, YBB 00272004–2015, FDA 21 CFR Part 11 (audit trail, e-signature, role-based 5-level access, data backup/recovery, power-fail protection) |
| Software | PULUODY V8.9 PC & Integrated Touchscreen Edition |
| Interface | Bilingual (English/Chinese) GUI |
| Calibration Standards | NIST-traceable latex spheres, ISO 21501-4, JJG 1061 |
| Metrology Support | Accredited by NWMS (China National Institute of Metrology Northwest Center) & DFKW Level-1 Particle Metrology Station No. 116 |
| Key | Brand: PULUODY |
|---|---|
| Model | PLD-601 |
| Origin | Shaanxi, China |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 1–450 µm (optional extension to 0.03–3000 µm) |
| Channel Count | 1000 adjustable size channels |
| Flow Rate (Sampling) | 5–150 mL/min |
| Flow Rate (Cleaning) | 5–500 mL/min |
| Accuracy | ±5% typical (per ChP 2020 & USP <788>) |
| Resolution | >95% (ChP-calibrated), <10% RSD (USP/ISO 21501-calibrated) |
| Sample Temperature Range | 0–80 °C |
| Environmental Operating Range | 0–50 °C |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9-2013, YBB00272004-2015, GB 8368 |
| Software | V8.9 PC & Embedded Analysis Suite with 21 CFR Part 11 Compliance (Audit Trail, Electronic Signature, Role-Based 5-Tier Access, Data Backup/Restore, Power-Fail Recovery) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Light Obscuration (LO) Particle Counter |
| Measurement Range | 1–500 µm |
| Repeatability | 1000 particles/mL (2.5% coincidence error) |
| Measurement Time | 60 seconds |