| Key Features | Max. crush force: 50 kN (5 T) |
|---|---|
| Sample chamber | W300 × D300 mm |
| Stroke range | 0–300 mm |
| Crush speed | 1–10 mm/s (adjustable, ±1 mm/s accuracy) |
| Force resolution | 1/500,000 FS |
| Force accuracy | ±0.5% of reading |
| Displacement resolution | 0.01 mm |
| Displacement accuracy | ±0.5% of reading |
| Data acquisition rate | ≥30 Hz |
| Voltage measurement | 0–36 V, ±0.1% FS |
| Temperature measurement | 0–600 °C, ±1 °C |
| Compliance | Designed per UN 38.3, GB/T 31485, IEC 62133, and ISO 12405 test protocols |
| Safety features | Dual-layer tempered explosion-proof observation window (350 × 400 mm), automatic pressure relief port, forced exhaust system, integrated LED lighting |
| Structural enclosure | Heavy-gauge cold-rolled steel (gray + blue epoxy finish) with stainless-steel interior |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-D23 |
| Instrument Type | Electronic Tensile Testing Machine |
| Maximum Test Load | 20 kN |
| Load Measurement Range | 2000 %FS |
| Load Accuracy | ±0.05 %FS |
| Test Stroke | 1000 mm |
| Displacement Resolution | 0.001 mm |
| Load Resolution | 1/500,000 |
| Force Unit Options | N, kgf, lbf, g, ton, MPa |
| Speed Range | 0.01–500 mm/min (PC-controlled) |
| Crosshead Travel Width | 420 mm |
| Power Supply | 220 V, 50/60 Hz, 10 A |
| Motor Drive | Servo Motor + Precision Ball Screw |
| Dimensions (W×D×H) | 880 × 600 × 1600 mm |
| Weight | ~115 kg |
| Standard Accessories | One set of fixtures, PC-based control software, USB interface cable |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-2231 |
| Temperature Range | −70 °C to +150 °C |
| Internal Volume | 80–800 L (5 standard configurations) |
| Heating Rate | ~20 min (0 °C → 100 °C), ~60 min (−70 °C → 100 °C) |
| Cooling Rate | ~20 min (20 °C → 0 °C), ~90 min (20 °C → −70 °C) |
| Control System | Programmable TFT-LCD controller with RS-232 interface, 5 patterns / 50 steps / 999 cycles |
| Construction | Full SUS#304 stainless steel interior and exterior |
| Cooling Configuration | Single-stage air-cooled refrigeration system (≥ −20 °C) |
| Standard Accessories | Two adjustable stainless steel shelves, vacuum-rated observation window, interior LED lighting, anti-fog heater |
| Safety Protections | Over-temperature, compressor overload, over-current, earth leakage |
| Power Supply | 1-phase, 220 V, 50 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | COF-1000 |
| Price | Upon Request |
| Test Speeds | 6, 12, and 24 in/min (15, 30, and 60 cm/min) |
| Static & Kinetic COF Measurement | Simultaneous, automated calculation |
| Stroke Length | 6 in (15.2 cm) |
| Test Platform Dimensions | 5 × 11 in (12.7 × 27.9 cm) |
| Standard Sled Mass | 200 g with ASTM-compliant rubber pad (2.5 in × 2.5 in / 6.35 cm × 6.35 cm) |
| Adjustable Sled Mass Range | 1–1000 g |
| Load Cell Capacity | 5 lbf (22.2 N / ~2.27 kgf) |
| Power Supply | 120 V or 240 V AC, 50/60 Hz |
| Operating Temperature | 0–70 °C |
| Software Interface | EZ-Lab™ compatible |
| Dimensions (H×W×D) | 10 × 26 × 12 in (25.4 × 66.0 × 30.5 cm) |
| Weight | 29 lb (13.2 kg) |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Model | PW-CFT100-40L5 |
| Temperature Range | -40°C to +150°C |
| Temperature Ramp Rate | 5°C/min (linear, unloaded) |
| Temperature Uniformity | ≤2°C (empty) |
| Temperature Stability | ≤±1°C (empty), ≤±2°C (loaded) |
| Temperature Deviation | ≤±2°C (empty) |
| Humidity Range | 20–98% RH |
| Humidity Uniformity | ≤±3% RH |
| Humidity Stability | ≤±2% RH |
| Humidity Deviation | ±3% RH (>75% RH), ±5% RH (≤75% RH) |
| Internal Dimensions (W×H×D) | 500×500×400 mm |
| Nominal Volume | 100 L |
| Refrigeration | Mechanical compression (R404A/R23) |
| Cooling Method | Water-cooled condenser |
| Construction | SUS304 stainless steel inner chamber, powder-coated cold-rolled steel outer shell |
| Insulation | 100 mm rigid polyurethane foam |
| Control System | 7-inch color TFT touchscreen PLC-based controller with multi-segment programmable logic, PID tuning, data logging, USB/CAN/RS-485/Ethernet interfaces |
| Compliance | GB/T 10592-2008, GB/T 2423.1–2423.4, GB/T 2423.22, GJB150.3A–150.9A, GB/T 10586-2006, GB/T 5170.18-2005 |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-1125 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 10 N to 50 kN (dual-range configuration available) |
| Force Resolution | 1/250,000 full scale |
| Force Accuracy | ≤ ±0.5% of reading |
| Crosshead Travel | 1000 mm |
| Test Width | 420 mm |
| Speed Range | 0.5–500 mm/min (computer-controlled) |
| Position Resolution | 0.005 mm |
| Control Mode | Full PC-based operation |
| Power Supply | 220 V, 50/60 Hz, 10 A |
| Motor Type | Servo motor with precision ball screw and timing belt transmission |
| Rated Power | 750 W |
| Dimensions (W×D×H) | 920 × 620 × 1990 mm |
| Weight | ~422 kg |
| Standard Accessories | One set of universal grips, proprietary test software, USB interface cable |
| Force Units | N, kgf, lbf, g, ton, MPa |
| Safety Features | Overload stop, emergency stop button, specimen rupture auto-stop, upper/lower limit programmable stop, automatic return-to-initial-position function |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-S90 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 10 N, 20 N, 50 N, 100 N, 200 N, 500 N, 1 kN (dual-range configuration available) |
| Force Resolution | 1/500,000 full scale |
| Force Accuracy | ±0.30% of reading |
| Displacement Resolution | 1/500,000 full scale |
| Test Stroke | 500 mm / 800 mm (model-dependent) |
| Test Width | 110 mm |
| Speed Range | 0.1–500 mm/min (software-controlled, step motor-driven) |
| Drive System | Precision preloaded ball screw with timing belt transmission |
| Power Supply | 220 V AC, 50/60 Hz, 10 A |
| Power Consumption | 180 W |
| Dimensions (W×D×H) | 40 × 37 × 92 cm (standard) |
| Net Weight | 28 kg / 35 kg |
| Compliance Standards | GB/T 2792, ASTM D3330, GB/T 12914–1991, GB 13022–91, GB/T 1040–92, GB 2792–81, GB/T 14344–9, GB/T 2191–95, QB/T 2171–95, GB/T 10003–2008 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PT-1000 |
| Pricing | Upon Request |
| Brand | PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PW-CTH100-40 |
| Instrument Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −40 °C to +150 °C |
| Humidity Range | 20 %RH to 98 %RH |
| Temperature Uniformity | ±1.0 °C |
| Temperature Stability | ±1.0 °C |
| Humidity Uniformity | ±2.0 %RH |
| Humidity Stability | ±1.0 %RH |
| Heating Rate | −40 °C to +100 °C in ≤45 min (unloaded) |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | RX1 Series |
| Chamber Internal Dimensions | 100 × 100 × 100 cm (W × H × D) |
| Ambient Temperature Range | Room Temperature (RT) |
| Spray Arm Radius | 0.35 m |
| Adjustable Spray Arm Length | 900–2700 mm |
| Stainless Steel Spray Pipe Diameter | 600 mm |
| Pipe Outer Diameter | 20 mm |
| Nozzle Diameter | 0.4 mm |
| Nozzle Spacing | Uniformly Distributed |
| Spray Pressure | 60–100 kPa |
| Turntable Speed | 1–10 rpm |
| Turntable Diameter | 30 mm |
| Power Rating | 1.5 kW |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-8801B |
| Track Angle | 21.3° |
| Ball Diameter | 7/16 in (14# steel ball) |
| Ramp Length | 6.5 in |
| Dimensions | 23 × 6 × 7 cm (L × W × H) |
| Weight | 0.8 kg |
| Compliance | GB/T 4852–2002, PSTC-7 |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-1151 |
| Price Range | USD 14,000 – 42,000 (FOB Guangdong) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Maximum Load Capacity | 100 kN (10 Ton-force) |
| Drive System | Precision Ball-Screw Actuator with AC Servo Motor |
| Control Mode | Closed-Loop Digital PID Control |
| Test Speed Range | 0.001 – 500 mm/min (adjustable in real time) |
| Displacement Resolution | ≤ 0.001 mm |
| Load Accuracy | ±0.5% of full scale |
| Crosshead Travel | 1,200 mm (standard) |
| Data Acquisition Rate | Up to 1,000 Hz |
| Compliance Standards | ASTM E4, ASTM E8/E8M, ISO 6892-1, GB/T 228.1-2021 |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YTS-100-40EC |
| Chamber Type | Vertical |
| Temperature Range | −55 °C to +150 °C |
| Humidity Range | 20 %RH to 98 %RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 %RH |
| Temperature Stability | ±1.0 °C |
| Humidity Stability | ±1.0 %RH |
| Internal Dimensions (W×H×D) | 400 mm × 500 mm × 500 mm |
| Cooling System | Dual-stage cascade refrigeration with two 375 W hermetic compressors (Tecumseh) |
| Refrigerant | R-404A (ozone-friendly) |
| Controller | 7-inch color touchscreen with PID auto-tuning, 12 program groups / 120 segments, data logging, USB export, RS-485 interface |
| Safety Protections | Over-temperature, over-humidity, compressor overheat/overcurrent, high-pressure cut-off, dry-burn prevention, phase-loss protection |
| Construction | Interior – mirror-finish SUS#304 stainless steel |
| Heating | Stainless steel finned tubular heaters (1 kW total) |
| Humidification | Stainless steel immersion heater with carbon-fiber water tank (non-condensing surface, anti-drip design) |
| Air Circulation | Adjustable multi-blade centrifugal fan (60 W), directional louver system |
| Compliance | Designed per IEC 60068-2-1, IEC 60068-2-2, ISO 17025-relevant environmental control requirements for material testing labs |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-1103B |
| Load Capacity Options | 10 N, 20 N, 50 N, 100 N |
| Travel Range | 300 mm |
| Test Speed | 1–500 mm/min (software-controlled) |
| Force Resolution | 1/250,000 full scale |
| Displacement Resolution | 0.005 mm |
| Dimensions | 92 × 30 × 38 cm |
| Weight | 36 kg |
| Power Supply | AC 220 V |
| Interface | USB |
| Sample Width Max | 110 mm |
| Sample Length Max | 400 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AR-2000 |
| Pricing | Available Upon Request |
| Display | 5.7-inch color touchscreen |
| Speed Range | 1–1200 ipm (3–3048 cpm) |
| Peel Angle Selection | 90° to 180° |
| Load Cell Options | 2, 5, 10, or 25 lbf |
| Sample Length Range | 0.5″–12″ (12.7–305 mm) |
| Operating Temperature | 0–70 °C (32–150 °F) |
| Accuracy | ±0.1% of full-scale load cell |
| Power Input | 220 VAC, 50/60 Hz |
| Dimensions (H×W×D) | 61 × 91 × 33 cm |
| Weight | 42 kg |
| Compliance Standards | PSTC-101 (A–F), PSTC-4, PSTC-15, PSTC-55, ASTM D3330, TLMI L-IA1/L-IA2/L-IA3, AFERA 4001 R11, FINAT FTM 1–6, 10, 11 |
| Data Interface | USB 2.0 |
| Software Integration | EZ-Date™ for data export and report generation |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | TF-150 |
| Internal Dimensions (W×H×D) | 50×60×50 cm |
| External Dimensions (W×H×D) | 103×141×91 cm |
| Chamber Volume | 150 L |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 20 %RH to 98 %RH (optional low-humidity configuration down to 5 %RH) |
| Temperature Uniformity | ±0.5 °C |
| Humidity Uniformity | ±3 %RH |
| Temperature Stability | ±0.3 °C |
| Humidity Stability | ±2.5 %RH |
| Heating Rate | −70 °C → +100 °C in approx. 60 min |
| Cooling Rate | +20 °C → −70 °C in approx. 90 min |
| Control System | PID + SSR/SCR bidirectional synchronous output with slope logic |
| Programmability | 150 programs × 1500 segments, segmentable and chainable |
| Cycle Capability | 9999 cycles × 999 repeats, subdivisible into 5 independent partial cycles |
| Safety Monitoring | 15-point real-time system diagnostics with fault logging and remediation guidance |
| Refrigeration | Twin-stage hermetic air-cooled system (R404A/R507) |
| Humidification | Surface evaporation type with auto water recovery and dry-run/overheat protection |
| Construction | SUS#304 stainless steel interior and exterior |
| Insulation | Rock wool + rigid polyurethane foam |
| Compliance | Designed per IEC 60068-2 series, ASTM D4332, ISO 16750-4, and GB/T 2423.1–2423.4 for environmental stress screening |
| Brand | Yuelian |
|---|---|
| Model | YL-1103 |
| Application | Tape peel strength testing for LED packaging carriers |
| Force Capacity Options | 10 N, 20 N, 50 N, 100 N, 200 N (dual-range configuration available) |
| Force Resolution | 1/250,000 full scale |
| Force Accuracy | ≤ ±0.5% of reading |
| Travel Resolution | 0.005 mm |
| Maximum Test Stroke | 500 mm |
| Test Width | Ø140 mm |
| Speed Range | 5–500 mm/min (PC-programmable) |
| Control Interface | PC-based with USB connectivity |
| Data Output | Real-time force–displacement curves, tabular reports (MS-ACCESS compatible), statistical parameters (peak force, average peel force, yield point, modulus approximation) |
| Safety & Stop Modes | Overload cutoff, emergency stop, automatic halt on specimen failure, programmable upper/lower limit stops, auto-return function |
| Drive System | Stepper motor + precision ball screw + timing pulley transmission |
| Power Supply | 220 V, 50/60 Hz, 5 A |
| Rated Power | 180 W |
| Dimensions (W×D×H) | 1063 × 300 × 200 mm |
| Net Weight | ~45 kg |
| Standard Accessories | One set of peel fixtures, proprietary test software, USB interface cable |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PA-1000-180 |
| Pricing | Available Upon Request |
| Load Cell Capacity | 10 lbf (4.5 kgf) |
| Force Resolution | ±0.1% of full scale |
| Test Speeds | 15, 30, and 60 cm/min (6, 12, and 24 in/min) |
| Peel Angle | 180° |
| Sample Platform | 5 × 15 cm (2 × 6 in) |
| Data Acquisition Rate | 400 Hz |
| Force Units | g, kg, oz, lb, N |
| Power Supply | 120 V or 240 V AC |
| Operating Temperature | 0–70 °C |
| Dimensions (H×W×D) | 20.3 × 58.5 × 30.5 cm |
| Weight | 13 kg |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PW-UD20 |
| Price Range | USD 1,400 – 12,800 (FOB Guangdong) |
| Max Load Capacity | 5 kN (optional sensor range: 10 N to 5 kN) |
| Control System | Full PC-based closed-loop servo control |
| Force Resolution | 1/500,000 FS |
| Displacement Resolution | 1/500,000 mm |
| Force Accuracy | ±0.3% of reading (sensor), system compliance with ISO 7500-1 Class 0.5 |
| Displacement Accuracy | ±0.5% of reading |
| Effective Stroke | 800 mm (customizable) |
| Speed Range | 0.01–500 mm/min (adjustable in 0.01 mm/min increments) |
| Test Space (W×D) | 420 mm × — mm (depth customizable) |
| Frame Material | Precision-machined 45# structural steel, sandblasted + electrostatic epoxy coating |
| Protection | Molded aluminum alloy dust cover, anodized surface finish |
| Drive System | High-torque AC servo motor + preloaded precision ground ball screw (C5 grade) |
| Position Feedback | High-line-count optical encoder (≥2,000 PPR), real-time digital interpolation |
| Load Cell | Dual-range or single-range S-type or cantilever load cell, temperature-compensated, bridge output (mV/V), IP65 rated |
| Data Acquisition | 24-bit isolated ADC with continuous unsegmented sampling, 500 kHz max sampling rate |
| Communication Interface | Optically isolated USB 2.0 (USB-B), compatible with Windows 10/11 x64 |
| Software Compliance | Supports 21 CFR Part 11 audit trail (optional configuration), GLP/GMP-ready metadata logging |
| Units | SI (N, mm, MPa), metric (kgf, cm), imperial (lbf, inch, kpsi) |
| Test Modes | Tensile, compression, flexure, peel, tear, shear, puncture, cyclic fatigue (displacement-, load-, or time-controlled) |
| Safety | Dual-channel hardware limit switches, overload cutoff, emergency stop, automatic post-fracture return, programmable upper/lower travel limits |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-1106F |
| Load Capacity | 50 N |
| Measurement Accuracy | ±1% FS |
| Resolution | 0.01 N |
| Crosshead Speed Range | 0.5–500 mm/min |
| Stroke | 200 mm |
| Power | 40 W |
| Voltage/Frequency | 220 V, 50 Hz |
| Dimensions (W×L×H) | 360 × 380 × 520 mm |
| Net Weight | 17 kg |
| Standard Accessories | Host unit, 1 sampling cutter, 10 stainless steel test plates |
| Compliant Test Standards | ASTM D6195, TLMI TT-001, FINAT FTM 1 |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-1161 |
| Pricing | Available Upon Request |
| Compliance | CNS 2276 |
| Operating Temperature Range | Up to 300 °C (configurable with optional furnace chamber) |
| Load Capacity | Standard configurations up to 50 kN |
| Control Mode | Standalone operation or PC-integrated via RS-232/USB |
| Data Acquisition Rate | Up to 100 Hz |
| Test Speed Range | 0.001–500 mm/min (adjustable) |
| Extensometer Compatibility | Dual-point clip-on and non-contact options supported |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-1125 |
| Instrument Type | Electronic Universal Testing Machine |
| Load Capacity Options | 10 N to 50 kN (dual-range configuration available) |
| Force Resolution | 1/500,000 full scale |
| Force Accuracy | ±0.3% of reading |
| Crosshead Travel | 1200 mm |
| Test Width | 420 mm |
| Speed Range | 0.01–1000 mm/min (programmable via PC) |
| Position Resolution | 1/500,000 full stroke |
| Control Interface | PC-based with USB connectivity |
| Compliance Standards | ISO 7500-1, ASTM E4, GB/T 228.1, GB/T 9341, GB/T 1449, ASTM D6109, JJG 475 |
| Power Supply | 220 V, 50/60 Hz, 10 A |
| Motor Drive | Servo motor with precision ball screw and timing belt transmission |
| Dimensions (W×D×H) | 92 × 62 × 199 cm |
| Weight | ~422 kg |
| Software | Windows-based test control & data analysis suite with MS Access database support, real-time curve plotting, multi-sensor input, GLP-compliant audit trail, and automated parameter calculation per ISO, ASTM, GB, JIS, DIN, EN standards |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-D1813Z5 |
| Load Capacity Options | 10 N, 20 N, 50 N, 100 N, 200 N, 500 N, 1 kN, 2 kN (dual-range configuration available) |
| Display Interface | PC-based GUI |
| Axes of Motion | X, Y, Z (independent translational axes) |
| Force Resolution | 1/500,000 full scale |
| Force Accuracy | ±0.5% of reading |
| Stroke Resolution | 1/500,000 |
| Maximum Stroke | 1000 mm |
| Test Width | 1500 mm |
| Speed Range | 0.01–1000 mm/min (programmable via software) |
| Force Unit Conversion | kgf, N, lbf, g, ton, MPa |
| Safety & Control Modes | Overload shutdown, emergency stop, specimen failure detection, upper/lower limit auto-stop, automatic return-to-home |
| Drive System | Servo motor with timing belt and precision ball screw transmission |
| Power Requirement | 220 V AC, 50/60 Hz, 10 A |
| Rated Power | 400 W |
| Standard Accessories | One set of universal grips, proprietary test software, USB interface cable |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HL Series |
| Pricing | Available Upon Request |
| Internal Dimensions (W×H×D, cm) | HL-A: 40×50×40 |
| HL-B | 50×60×50 |
| HL-C | 60×75×60 |
| HL-D | 60×85×80 |
| HL-E | 100×100×80 |
| HL-F | 100×100×100 |
| External Dimensions (W×H×D, cm) | HL-A: 110×136×71 |
| HL-B | 117×146×85 |
| HL-C | 130×166×91 |
| HL-D | 140×176×101 |
| HL-E | 170×186×111 |
| HL-F | 180×196×123 |
| Temperature Range | −70 °C to +150 °C (selectable standard setpoints: 0 °C, −20 °C, −40 °C, −60 °C, −70 °C) |
| Temperature Display Resolution | ±0.1 °C |
| Heating Rate | Approx. 3 °C/min |
| Cooling Rate | Approx. 1 °C/min |
| Construction Material | Full SUS304 stainless steel (matte finish) |
| Insulation | High-density polyisocyanurate foam with high-temperature resistance |
| Refrigeration System | Air-cooled, dual-stage cascade refrigeration with French Tecumseh compressors |
| Refrigerants | R-404A (low-temp stage), R-23 (ultra-low-temp stage) |
| Controller | Imported LCD touchscreen interface with real-time display of setpoint/actual value/time |
| Safety Protections | Fuseless circuit breaker, compressor overload protection, refrigerant high/low pressure switches, over-temperature/over-humidity cut-off, fault diagnostic alarm system |
| Standard Accessories | Double-layer heated observation window with anti-fog heater, internal PL fluorescent lighting, 50 mm diameter test port, adjustable stainless steel shelves, built-in casters with locking mechanism |
| Power Supply | Single-phase 220 VAC ±10%, 50/60 Hz or three-phase 380–415 VAC ±10%, 50/60 Hz |