- All
- Favorite
- Popular
- Most rated
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Ocean HR6 |
| Spectral Range | ~185–1100 nm |
| Optical Resolution | <1.0 nm FWHM (configurable, e.g., with 25 µm slit) |
| Signal-to-Noise Ratio | 3500:1 (on-board averaging mode) |
| Dynamic Range | 12,000:1 (single-scan) |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | NIRQuest+ |
| Spectral Range | 900 nm – 2500 nm |
| Detector | InGaAs linear array |
| Resolution | 3.13 nm FWHM (typical), 5.47 nm FWHM (typical), 6.25 nm FWHM (typical) |
| Signal-to-Noise Ratio | >15,000:1 @ 100 ms integration |
| >13,000 | 1 @ 1000 ms integration |
| Dynamic Range | 7.5 × 10⁶ (system) |
| 10,000 | 1 (single acquisition) |
| Slit Width | 25 µm |
| Grating Options | GRATING_#NIR1, GRATING_#NIR2, GRATING_#NIR3 |
| Order-Sorting Filter | OF1-RG830 long-pass NIR filter (optional) |
| Dimensions | 182 × 110 × 47 mm |
| Weight | 1.18 kg (without power supply) |
| Integration Time | 1 ms – 12 s |
| Dark Noise | 6 RMS counts @ 100 ms |
| Fiber Connector | SMA 905 |
| Thermoelectric Cooling | -20 °C |
| Brand | Ocean Optics |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | HDX |
| Spectral Range | 200–925 nm |
| Detector | Back-Illuminated CCD |
| Resolution | 0.61–0.72 nm FWHM (with 10 µm slit) |
| Signal-to-Noise Ratio | 400:1 |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.1% (typical, 3 AU at 600 nm) |
| A/D Conversion | 16-bit |
| Integration Time | 6 ms – 10 s |
| Thermal Stability | ±1 pixel over 0–40 °C |
| F-number | f/4 |
| Onboard Memory | Up to 50,000 spectra |
| I/O | 8 user-programmable digital I/O lines |
| Communication Interfaces | USB 2.0, Gigabit Ethernet, Wi-Fi (802.11 b/g/n), SPI, RS-232 |
| Operating Temperature | 0–40 °C |
| Dimensions | 88.9 × 63.5 × 52.4 mm |
| Weight | 400 g |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Origin | Domestic (China) |
| Model | NIRQuest |
| Instrument Type | Laboratory |
| Application Field | Grain Analysis |
| Operating Principle | Portable & Online Deployment |
| Wavelength Range | 900–1700 nm (extendable to 2500 nm) |
| Scan Speed | 1 ms |
| Measurement Mode | Diffuse Reflectance / Transmission |
| Detector | InGaAs Linear Array with Integrated Thermoelectric Cooling |
| Optical Platform | Crossed Czerny-Turner |
| A/D Resolution | 16-bit USB |
| Interface | SMA905 Fiber Optic Connector |
| Compliance | Compatible with ASTM E1655, ISO 12099, USP <856>, and GLP/GMP-aligned data workflows |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Spectrophotometer |
| Instrument Type | In-Line |
| Optical Geometry | d/8° (Diffuse Illumination / 8° Viewing) |
| Light Source | Pulsed LED |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | 0.01 ΔE*ab |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | NIRQuest+ |
| Instrument Type | Portable |
| Operating Principle | Grating-Based Scanning Spectrometer |
| Wavelength Range | 900 nm – 2500 nm |
| Detector | Thermoelectrically Cooled InGaAs Linear Array |
| Slit Width | 25 µm |
| Optical Resolution (FWHM) | 3.13 nm (typ.), 5.47 nm (typ.), 6.25 nm (typ.) |
| Integration Time | 1 ms – 12 s |
| Dark Noise | 6–24 RMS counts (dependent on integration time) |
| Dynamic Range | 7.5 × 10⁴ (system) |
| 10,000 | 1 (single acquisition) |
| Signal-to-Noise Ratio | >15,000:1 @ 100 ms |
| >13,000 | 1 @ 1000 ms |
| Dimensions | 182 × 110 × 47 mm |
| Weight | 1.18 kg (without power supply) |
| Fiber Connector | SMA 905 |
| Order-Sorting Filter | OF1-RG830 Longpass NIR Filter (optional) |
| Grating Options | GRATING_#NIR1, GRATING_#NIR2, GRATING_#NIR3 |
| Brand | Ocean Optics |
|---|---|
| Model | LSM |
| Light Source Type | High-Stability Narrowband LED |
| Illumination Mode | Internal Illumination (Fiber-Coupled) |
| Optical Interface | SMA 905 |
| Dimensions (LSM) | 3.0 × 6.4 × 3.3 cm |
| Weight (LSM) | 120 g |
| Power Consumption (LSM) | ≤2 A max |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤85% RH, non-condensing |
| Safety Compliance | CE |
| Dimensions (LDC-1 Controller) | 14.7 × 7.3 × 8.9 cm |
| Weight (LDC-1) | 800 g |
| Power Supply | 15 VDC, 30 W max |
| Display | 3.5″ 480×320 touchscreen |
| Modulation Modes | Internal DC, sine, triangle, square wave |
| Max Drive Current | 350–2000 mA (model-dependent) |
| Typical CW Output Power (into 400 µm, 0.39 NA fiber) | 0.18–20.55 mW |
| Pulsed Output Power (same fiber) | 0.22–20.55 mW |
| Center Wavelength (CWL) Range | 265–880 nm |
| FWHM | 1–44 nm (model-dependent) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DH-2000 |
| Light Source Type | Deuterium + Tungsten-Halogen Hybrid |
| Illumination Mode | External Illumination |
| Spectral Range | 190–1700 nm (UV-enhanced option), 215–2000 nm (standard) |
| Dimensions | 150 mm × 135 mm × 319 mm |
| Weight | 3.5 kg |
| Power Consumption | 25 W (deuterium lamp), 20 W (tungsten-halogen lamp), ~78 VA total |
| Warm-up Time | 40 min (D₂), 20 min (W-Hal) |
| Lamp Lifetime | 1,000 hours |
| Operating Temperature | 5–35 °C |
| Humidity | 5–95% RH at 40 °C (non-condensing) |
| Voltage Stability | <5 × 10⁻⁶ peak-to-peak (0.1–10.0 Hz) |
| Drift | <0.01% per hour |
| Safety Certifications | CE, VDI/VDE 0160, EN 61010 |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Ocean SR4 |
| Detector Type | 3648-pixel CCD linear array |
| Spectral Range | 190–1100 nm (configurable) |
| Optical Resolution (25 µm slit) | 1.36–1.65 nm (FWHM) |
| Signal-to-Noise Ratio | 3000:1 (per second, High-Speed Averaging Mode) |
| Dynamic Range | 1370:1 (single scan) |
| Integration Time | 3.8 ms – 10 s |
| Stray Light | < 2.3 AU |
| Thermal Wavelength Stability | 0.05 pixels/°C |
| Scan Rate | 74 spectra/s |
| ADC | 16-bit |
| Trigger Modes | External TTL, Software, Hardware Synchronization |
| Interface | USB 3.2 Gen 1 (Type-B connector, TFM-108-02-L-DH compliant) |
| Dimensions | 88.1 × 63.5 × 31.4 mm |
| Weight | 254 g |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Ocean SR6 |
| Detector Type | CCD |
| Spectral Range | ~185–1100 nm (configuration-dependent) |
| Optical Resolution (25 µm slit) | 0.50–2.0 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | 3500:1 (on-board averaging mode) |
| Dynamic Range | 12,000:1 (single-scan) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 200–3900 cm⁻¹ (configurable options) |
| Spectral Resolution | 4–12 cm⁻¹ (dependent on grating and spectral window selection) |
| Laser Wavelength | 785 nm ± 0.5 nm, linewidth < 2 cm⁻¹, frequency stability < 0.1 cm⁻¹ |
| Laser Power | Up to 350 mW, 10-step linear adjustment |
| Detector | TE-cooled back-illuminated thin CCD array |
| Signal-to-Noise Ratio | 1000:1 |
| Integration Time | 0.1–30 s |
| Optical NA | 0.22 |
| Working Distance | 7.5 mm |
| Display | 4.5″ capacitive multi-touch LCD (720p) |
| Data Interfaces | USB 2.0, Wi-Fi |
| Data Formats | .pdf, .csv, .txt, .jdx, .rdb |
| Battery Life | >5 hours (rechargeable Li-ion) |
| Weight | 330 g (handheld probe), 3.8 kg (main unit) |
| Dimensions | 15.5 × 7.4 × 2.5 cm (probe), 29 × 22 × 10 cm (main unit) |
| Operating Temperature | 0–45 °C |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Maya 2000 |
| Spectral Range | 200–1100 nm |
| Detector Type | Back-illuminated 2D FFT-CCD (Hamamatsu S9840) |
| Quantum Efficiency | up to 90% @ 250 nm |
| Signal-to-Noise Ratio | 450:1 (full well, with 5 s integration) |
| Dynamic Range | 15,000:1 (typical, A/D-limited) |
| Stray Light | <0.05% @ 600 nm |
| Optical Resolution (FWHM) | ~0.035 nm (configurable via grating and slit selection) |
| Integration Time | 5 ms – 20 s |
| A/D Conversion | 16-bit, 500 kHz sampling |
| Pixel Array | 2048 × 14 active pixels (14 µm × 14 µm) |
| Readout Speed | Optimized for high-throughput acquisition |
| Slit Options | 5, 10, 25, 50, 100, 200 µm |
| Grating Options | 14 standard gratings, including HC-1 broadband grating (175–1100 nm) |
| Onboard Features | 10 user-programmable GPIOs, programmable trigger modes (single/continuous), integrated order-sorting filters, focusing lens assembly for enhanced throughput |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Ocean ST |
| Spectral Range | 185–650 nm (UV-VIS), 350–810 nm (VIS-NIR), 645–1085 nm (NIR) |
| Optical Resolution | 2.2 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | >250:1 (full-scale, single-scan, typical) |
| Dynamic Range | 1000:1 (single-scan) |
| Stray Light | <0.2% at 600 nm (typical) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Nano-Sponge SERS Substrate |
| Pricing | Available Upon Request |
| Brand | Ocean Optics |
|---|---|
| Model | MX Pro |
| Instrument Type | Benchtop |
| Integration | Fully Integrated Multi-Channel Spectrometer |
| Spectral Range | 180–1100 nm |
| Max Channels | 8 |
| Optical Resolution (FWHM) | 0.1 nm (configurable) |
| SNR (single-scan) | 380:1 |
| A/D Resolution | 16-bit |
| Detector Options | Linear CCD or Area CCD |
| Scan Rate | 500 Hz |
| Integration Time | 1 µs – 2 s |
| Trigger Delay Range | –450 ns to +450 ns |
| Trigger Jitter | 20–30 ns |
| Timing Step Resolution | 13.8 ns |
| Trigger Interface | TTL-compatible, <5.5 V |
| Data Interface | USB 3.0 |
| Power Supply | 5 V DC, 5 A |
| Operating Systems | Windows 7/8/10/11 (32-/64-bit) |
| Dimensions (8-ch) | 585 × 165 × 210 mm |
| Weight (8-ch) | 12 kg |
| Dimensions (4-ch) | 345 × 165 × 210 mm |
| Weight (4-ch) | 6.5 kg |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | QE Pro Raman+ |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 150 cm⁻¹ – 4000 cm⁻¹ |
| Spectral Resolution | 0.42 nm (FWHM, typical) |
| Detector | TE-cooled 1044 × 64-pixel back-thinned FFT-CCD |
| Quantum Efficiency | 90% (peak) |
| Signal-to-Noise Ratio | 1000:1 (single acquisition) |
| Integration Time | 8 ms – 3600 s |
| Dynamic Range | ~85,000:1 |
| Optical Interface | SMA 905 |
| Onboard Memory | 15,000 spectra |
| Dimensions | 182 mm × 110 mm × 47 mm |
| Weight | 1.15 kg (instrument only) |
| Power Supply | 0.45 kg |
| Operating Temperature | 0 °C – 50 °C |
| Humidity | ≤90% RH (non-condensing) |
| Communication | USB 2.0 (480 Mbps, USB 1.1 compatible), RS-232 |
| Brand | Ocean Optics |
|---|---|
| Origin | Imported |
| Manufacturer | Ocean Optics |
| Model | HL-2000-CAL |
| Light Source Type | Tungsten-Halogen (Calibrated) |
| Illumination Mode | External Illumination |
| Spectral Range (Calibrated) | 300–1050 nm |
| Output Intensity Unit | µW/cm²/nm |
| Power Supply | 12 VDC, 600 mA |
| Lamp Power | 6.5 W |
| Lamp Lifetime | 900 h |
| Recommended Recalibration Interval | Every 50 h of operation |
| Color Temperature | 3100 K |
| Voltage Stability | ±0.2% |
| Warm-up Time to Stability | ~30 min |
| Fiber Connector | SMA905 |
| Cosine Adapter Interface | 6.35-mm barrel |
| Integrating Sphere Interface | PTFE plug |
| Certifications | NIST-traceable calibration certificate provided (paper + digital) |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | SQUARE ONE |
| Pricing | Upon Request |
| Cuvette Pathlength | 1 cm |
| Enclosure | Light-Tight Lid |
| Filter Slots | 2 (accepts 12.5 mm or 25 mm diameter optical filters) |
| Integrated Mirror | 74-MSP Specular Reflector |
| Diffuse Reflector Option | CVD-DIFFUSE PTFE-coated Surface |
| Collimating Lenses | Three Fused Silica Lenses (200–2000 nm transmission) |
| Fiber Optic Interface | SMA 905 |
| Dimensions | 111 × 90 × 74 mm |
| Weight | 618 g |
| Brand | Ocean Optics |
|---|---|
| Model | HL-2000 |
| Light Source Type | Tungsten-Halogen |
| Spectral Range | 360 nm – 2000 nm |
| Output Power | 7 W (standard), 20 W (HP variant) |
| Lamp Life | 1,500 h (standard), 10,000 h (LL variant), 2,000 h (HP) |
| Stability | ±0.5% |
| Drift | <0.3% per hour |
| Warm-up Time | ~5 min |
| Color Temperature | 2,960 K (standard), 2,800 K (LL), 3,000 K (HP) |
| Operating Temperature | 5–35 °C |
| Relative Humidity | 5–95% at 40 °C |
| Cooling | Integrated fan-cooled thermal management |
| Fiber Interface | SMA905-compatible adjustable coupling |
| Filter Holder | 25.4 mm × 25.4 mm or 50.8 mm × 50.8 mm square, 3 mm thick |
| Control Interface | RS-232 (optional on HP-RS-232), TTL shutter, manual attenuator |
| Shutter Options | Manual and TTL-controlled (HL-2000-FHSA) |
| Power Supply | Integrated stabilized DC supply |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Spectral Measurement Kit |
| Spectral Range | 200–1100 nm (configurable) |
| Detector Type | CCD or CMOS (application-dependent) |
| Optical Resolution | Configurable (typically 0.1–10 nm FWHM, dependent on grating and slit) |
| Sensitivity | Configurable (quantum efficiency up to ~90% in visible range) |
| Signal-to-Noise Ratio | ≥300:1 (full signal, 1 s integration) |
| Dynamic Range | >4.5 OD (optical density) |
| Stray Light | <0.05% at 600 nm, <0.1% at UV edge |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory |
| Optical Principle | Fixed-grating array-detector non-scanning spectrometer |
| Wavelength Ranges | NIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm) |
| Detector | InGaAs linear array (TE-cooled) |
| Resolution | 1.7–4.0 nm FWHM (configuration-dependent) |
| Integration Time | 1 ms to 65 s |
| Interface | USB 3.0 or Ethernet (optional) |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 ready (with compliant software stack) |
| Brand | Ocean Optics |
|---|---|
| Model | HPX-2000 |
| Light Source Type | Xenon Lamp |
| Spectral Range | 185–2200 nm |
| Output Power | 35 W |
| Electrical Input | 60 W AC |
| Dimensions | 145 × 165 × 260 mm |
| Weight | 5000 g |
| Lamp Lifetime | ≥1000 h (typ. 2000 h) |
| Shutter Control | Integrated mechanical shutter with manual switch & TTL-compatible trigger (15-pin D-sub) |
| Filter Holder | Accepts 25 mm round or 25 × 25 mm square filters, up to 14 mm thick |
| Fiber Coupling | SMA 905 connector |
| UV-Optimized Operation | Requires UV-grade optical fiber for sub-300 nm applications |
| Brand | Ocean Optics |
|---|---|
| Model | Flame-NIR+ |
| Type | Portable NIR Spectrometer |
| Principle | Grating-based Scanning Spectrometer |
| Wavelength Range | 970–1700 nm |
| Optical Resolution | ~10 nm FWHM (25 µm slit) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 (single acquisition) |
| Thermal Drift | 0.08 nm/°C |
| Scan Rate | ~400 Hz |
| Integration Time | 1 ms to 45 s |
| Detector | Uncooled InGaAs linear array (128 pixels) |
| Dimensions | 89.1 × 63.3 × 31.9 mm (34.4 mm including feet) |
| Weight | 265 g |
| Interface | Micro-USB |
| Origin | Shanghai, China |
| Manufacturer | Ocean Optics (Shanghai) |
| Brand | Ocean Optics |
|---|---|
| Model | FD-LTMS |
| Wavelength Range | 400–700 nm |
| Detector | 1024-element linear array |
| Optical Design | Asymmetric crossed Czerny-Turner spectrometer |
| Spectral Sampling Interval | 10 nm |
| FWHM | 6 nm |
| Light Source | Pulsed LED (>250 million measurements lifetime) |
| Sample Holders | 10 mm pathlength cuvette & flow-cell interface |
| Connectivity | USB 2.0 |
| OS Compatibility | Windows 7+, 64-bit |
| Enclosure Rating | IP67 |
| Origin | Shanghai, China |
| Manufacturer | Ocean Optics (Shanghai) |
Show next