BrandYoke
OriginShanghai, China
ModelRG-3618AA
Wavelength Range190–900 nm
Wavelength Repeatability≤0.05 nm
Wavelength Accuracy±0.1 nm
Photometric Range0–2.0 A (Absorbance)
Optical SystemDual-Beam
Lamp Positions8-position rotating turret (compatible with high-performance hollow cathode lamps)
Background CorrectionCombined deuterium lamp and self-reversal (SR) full-spectrum background correction
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelT3202S
Optical DesignDual-beam
DetectorPhotomultiplier Tube (PMT)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth1 nm (standard), adjustable to 0.5/1/2/4/5 nm
Stray Light≤0.03% at 220 nm (NaI)
Display10.1-inch capacitive touchscreen
Data StorageInternal 8 GB + USB drive support
InterfaceRS-232C, USB Device, USB Host
Onboard MemoryUp to 5000 absorbance measurements or 500 calibration curves
Optional Accessories8-position rotating cuvette changer, integrated flow cell system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUniCo
OriginShanghai, China
Instrument TypeSingle-Beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Spectral Bandwidth1.8 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability≤0.2 nm
Stray Light≤0.05% T
Display7-inch high-resolution color touchscreen
Data InterfaceUSB storage, Bluetooth printing & mobile app integration
Scan SpeedUp to 3000 nm/min (high mode)
Scan Interval Options0.1, 0.2, 0.5, 1, 2, 5 nm
Kinetic Sampling Interval0.5 s minimum
Kinetic DurationUp to 9 hours
Calibration ModesZero-order, first-order (with/without intercept), second-order, third-order polynomial regression
Standard Curve MethodsSingle-wavelength, dual-wavelength (isosbestic point), three-point calibration
File Capacity100 measurement records per test type
ComplianceDesigned for routine QC and R&D use in GLP-aligned laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUniCo
OriginShanghai, China
ModelUV-4802
Optical SystemDual-Beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability±0.1 nm
Spectral Bandwidth1.8 nm
Stray Light≤0.05% T
Photometric Accuracy±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T
Photometric Repeatability±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T
Baseline Drift±0.002 A/h (at 500 nm, after warm-up)
Display320 × 240 graphic LCD
Data InterfaceUSB port
Dimensions (W × D × H)625 × 405 × 280 mm
Weight23 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
Instrument TypeBenchtop Laboratory Conductivity Meter
Measurement ParametersConductivity, TDS, Resistivity, Salinity, Temperature
Conductivity Range0.000 µS/cm to 3000 mS/cm
TDS Range0.000 mg/L to 1000 g/L
Resistivity Range5.00 Ω·cm to 100.0 MΩ·cm
Salinity Range0.00–8.00% (w/w)
Temperature Range−5.0 to 130.0 °C
Accuracy±0.5% of full scale (FS)
Minimum Resolution0.001 µS/cm
CalibrationUp to 5-point conductivity calibration with auto-recognition of GB-standard reference solutions (4 preloaded)
Compensation ModesAutomatic temperature compensation (ATC), pure water conductivity correction, seawater salinity compensation
ConnectivityRS232/USB interface for PC and USB flash drive
Data Management1000 stored measurement records per parameter type
Software CompatibilityLeici LabSuite™ PC software (optional) for data export, statistical analysis, report generation, and 21 CFR Part 11–compliant electronic signatures
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelL6
Optical DesignDual-Beam
DetectorPhotomultiplier Tube (PMT)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth1 nm
Stray Light≤0.03% at 220 nm (NaI)
Automation LevelAutomatic Wavelength Scanning & Lamp Switching
ConnectivityUSB 2.0, Wi-Fi Module, Bluetooth 4.2
Data Storage Capacity500 spectra, 30 calibration curves
Software CompatibilityYokelab PC Suite (optional), Excel-compatible CSV export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUniCo
OriginShanghai, China
ModelUV-3802
Optical SystemPseudo-Double-Beam
Detector TypePhotocell
Wavelength Range190–1100 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability±0.1 nm
Spectral Bandwidth1.8 nm
Stray Light≤0.05% T
Photometric Accuracy±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T
Photometric Repeatability±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T
Baseline Stability±0.002 A/h (at 500 nm, after warm-up)
Display320 × 240 graphical LCD
Data InterfaceUSB port
Dimensions (W×D×H)625 × 405 × 280 mm
Weight22 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBM
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Model9W
Instrument ArchitectureSingle-Beam
Detector TypePhotomultiplier Tube (PMT)
Wavelength Range200–1000 nm
Wavelength AdjustmentManual
Spectral Bandwidth2 nm
Wavelength Accuracy±0.5 nm
Wavelength Repeatability±0.2 nm
Stray Light≤0.5%
Objective Magnifications20× (NA 0.26), 23× (NA 0.30), 26× (NA 0.34), 29× (NA 0.38)
Projection Magnification21×
Illumination Source12 V / 50 W Tungsten-Halogen Lamp
Slit Width Adjustment0–3 mm (graduated to 0.01 mm)
Height Adjustment0–20 mm (graduated to 2 mm)
Stage TravelLongitudinal 0–90 mm (1 mm scale), Transverse 0–220 mm (coarse) + 0–25 mm (fine, 0.01 mm resolution)
Selenium Photocell Active AreaØ25 mm
Sensitivity400–500 µA/lm
Lifetime≥500 h
Galvanometer Sensitivity2.5 × 10⁻⁹ A/mm/m
Oscillation Period1 s
Net Weight50 kg
Dimensions (L × W × H)1500 × 900 × 800 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelT-U6S
Optical SystemDual-beam with CT monochromator
DetectorHamamatsu photomultiplier tube (PMT)
Wavelength Range190–1100 nm
Spectral Bandwidth1 nm (fixed)
Wavelength Accuracy±0.3 nm
Wavelength Repeatability≤0.1 nm
Stray Light≤0.03% at 220 nm (NaI)
Display7-inch TFT-LCD (1024×768) with Omron tactile keypad
Internal Storage32 GB flash memory
Data CapacityUp to 5,000 absorbance measurements or 500 calibration curves
Processor32-bit ARM Cortex-M3 @ 120 MHz
InterfaceRS-232C (printer), USB Device (PC connection), USB Host (U-disk support)
File Export FormatsCSV, QUA, TXT, BMP
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSANXIN
OriginShanghai, China
Instrument TypePortable
Parameter TypespH, ORP, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen, Temperature
pH Range−2.00 to 19.999
pH Resolution0.1 / 0.01
pH Accuracy±0.01
Conductivity Range0–200 mS/cm (5 segments)
Conductivity Accuracy±1.0% FS
DO Range0–40.00 mg/L, 0–199.9% saturation
DO Accuracy±0.10% FS
Temperature CompensationAutomatic (0–100 °C for pH
CalibrationAuto-recognition of 13 pH buffers (US, NIST, Chinese series)
Data Storage100–400 sets
Power2 × AA batteries (1.5 V), >100 h life
Dimensions (meter)65 × 120 × 31 mm
Weight (meter)180 g
Ingress ProtectionIP57
CertificationsISO 9001:2000, CE, CMC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelFP6450
Detection ElementsK, Na, Li, Ca, Ba
Detection LimitsK: 0.001 mmol/L
Na0.001 mmol/L
Li0.005 mmol/L
Ca0.01 mmol/L
Ba0.02 mmol/L (typical)
Response Time<8 s
RepeatabilityRSD ≤1.5%
Sample Uptake Rate6–8 mL/min
Display7-inch capacitive touchscreen LCD
Data StorageUp to 10-point calibration curves and 200 sample results
ConnectivityUSB port, USB flash drive export, cloud-enabled data synchronization
Safety FeaturesAutomatic flame-out detection, gas leak alarm
Calibration ModesLinear and piecewise linear (broken-line)
Power SupplyAC 220 V ±10%, 50 Hz ±1 Hz
Rated Power30 W
PrinterOptional external thermal printer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeichi
OriginShanghai, China
Instrument TypeBenchtop Conductivity Meter
Measurement PrincipleTwo-electrode AC conductivity measurement with frequency auto-switching
Conductivity Range0.000 µS/cm to 200.0 mS/cm
TDS Range0.000 mg/L to 100.0 g/L
Temperature Range−5.0 °C to 110.0 °C
Display6-inch high-resolution LCD
Protection RatingIP54
CalibrationSingle-point calibration with auto-recognition of four standard solutions (146.5 µS/cm, 1408 µS/cm, 12.85 mS/cm, 111.3 mS/cm)
Temperature CompensationAutomatic and manual modes
Data Storage50 measurement sets with recall and deletion
ComplianceJB/T 9366–2017, GB/T 11007–2008, JJG 376–2007, HJ 1396–2024
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
Modeli5
QuotationUpon Request
Optical DesignSingle-Beam
DetectorPhotodiode Array (PDA)
Wavelength Range360–900 nm (Visible Region)
Wavelength ScanningAutomatic
Spectral Bandwidth4 nm
Wavelength Accuracy±2 nm
Wavelength Repeatability≤1 nm
Stray Light≤0.5%T at 420 nm (NaNO₂ reference)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUNICO
OriginShanghai, China
ModelV-1850
Optical SystemSingle-beam
DetectorPhotodiode Array
Wavelength Range315–1100 nm
Spectral Bandwidth2 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability≤0.2 nm
Stray Light≤0.05% T (at 220 nm & 340 nm)
Display Resolution0.1 nm
InterfaceUSB, Bluetooth, Touchscreen (7″ TFT, 800×480)
Power Input80–250 V AC, 50/60 Hz
Dimensions485 × 365 × 200 mm
Weight11 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelT-N6000Plus
Optical SystemDual-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Spectral Bandwidth1 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability≤0.1 nm
Stray Light≤0.03% (at 220 nm, using NaI solution)
Display7-inch color TFT LCD
Data Storage8 GB internal flash memory (supports up to 5000 absorbance readings or 500 calibration curves)
Processor32-bit ARM Cortex-M3 @ 120 MHz
Lamp Life≥2000 hours (automatically switched D₂ and W lamp with usage tracking)
Grating1200 lines/mm holographic plane grating
Sample CompartmentLarge-volume chamber compatible with optional 8-position rotating carousel or 5-position ultra-wide sample holder
ConnectivityRS-232 printer port, USB Host (Type-B), USB Device (Type-A), firmware upgrade via network
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDELEITE
OriginShanghai, China
ModelAPT300
Instrument TypeGeneral-Purpose Potentiometric Titrator
Measurement Range0 to ±1999 mV, 0 to 14.00 pH
Accuracy0.1% F.S. (mV), ±0.01 pH
Control Precision±0.03 pH, ±3 mV
Input Impedance>10¹² Ω
Operating Temperature5–40 °C
Relative Humidity<85% RH
Power SupplyAC 220 V ±10%, 50 Hz
Power Consumption20 W
Weight6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSartorius
OriginGermany
ModelMA100
Heating MethodInfrared (with optional halogen and quartz heating elements)
Readability0.1 mg
CertificationEC Type Approval for heating unit and weighing system
Drive MechanismMotor-driven integrated heating unit
OptionalBuilt-in thermal printer
Cleaning DesignPlug & Dry™ removable heating module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
Instrument TypeBenchtop
Parameter TypesMulti-parameter (pH, mV, Temperature)
Measurement Range(−2.00 to 20.00) pH
Resolution0.01 pH (selectable to 0.1 pH)
Accuracy±0.01 pH
Temperature CompensationAutomatic and Manual
Calibration Points1–5-point pH calibration
Buffer RecognitionAuto-identification of GB, DIN, and NIST standard buffer sets
Data Storage Capacity500 measurement records
ComplianceGLP-compliant data management
ConnectivityRS-232 (for serial printers), USB (for PC communication)
Protection RatingIP54
Standard AccessoriesTri-combination pH electrode, electrode stand, dust cover, calibration buffer solutions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelSCH-02
Instrument TypeMultifunctional Autosampler
Maximum Sample Capacity24 positions
Minimum Injection Volume50 µL
Positioning Accuracy±0.1 mm
Actuation MethodRobotic Arm Drive
Needle Wash ModeAutomated Solvent Rinse (Integrated Wash Station with Dual-Solvent Capability)
Repeat Injection Cycles1–99 (Programmable)
Post-Injection PurgeYes (Automatic Residue Blow-Off)
Compatible Sample Tray Configurations32-position × 50 mL
Stirring FunctionOptional Top or Bottom Magnetic Stirring
Interface OptionsUSB + RS-232
Communication ProtocolASCII-based Command Set (Documented for Third-Party Integration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
Modeli-301
PortabilityPortable
Intended UseLaboratory
Conductivity Range0.000 µS/cm to 200 mS/cm
TDS Range0–100 g/L
Resistivity Range0–10 MΩ·cm
Salinity Range0–80 ppt
Temperature Range−5 to 55 °C
Accuracy±0.5% FS (conductivity), ±0.1 °C (temperature)
Minimum Resolution0.01 µS/cm (conductivity), 0.1 °C (temperature)
Display7-inch color TFT capacitive touchscreen
CalibrationAuto-identification of standard solutions
cell constant options0.01, 0.1, and 1.0 cm⁻¹
ComplianceIP54 ingress protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUniCo
OriginShanghai, China
ModelUV-2800A
Optical SystemSingle-beam with 1200 lines/mm holographic grating
Wavelength Range190–1000 nm
Spectral Bandwidth1.8 nm
Wavelength Accuracy±0.5 nm
Wavelength Repeatability≤1 nm
Stray Light≤0.05% T
Detector TypePhotocell
Wavelength Scanning ModeMotorized automatic wavelength drive
Display320 × 240 graphic LCD
Data InterfaceUSB port for direct data export to USB flash drive
Dimensions (W × D × H)545 × 245 × 260 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelT-N6000
Optical DesignSingle-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth1 nm
Stray Light≤0.03% (at 220 nm, using NaI solution)
Display7-inch color TFT touchscreen
Data StorageInternal 8 GB flash memory (supports ≥5000 absorbance readings or ≥500 calibration curves)
Processor32-bit ARM Cortex-M3 @ 120 MHz
Lamp Life≥2000 hours (dual-lamp auto-switching with usage logging)
Grating1200 lines/mm plane holographic grating
InterfaceRS-232, USB Host (Type-B), USB Device (Type-A), optional thermal printer port
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSANXIN
OriginShanghai, China
ModelPHB-3
Instrument TypePen-style pH Meter
Measurement Range0.0–14.0 pH
Resolution0.1 pH
Accuracy±0.01 pH
CalibrationSingle-point (pH 7.00)
Temperature CompensationNone
Power SupplyTwo AAA batteries (1.5 V × 2)
Dimensions176 × 25 × 39 mm
Weight95 g
IP RatingIP57
Calibration Solution CompatibilityUSA-standard pH buffers (e.g., pH 4.01, 7.00, 10.01)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelCond 3310
PortabilityPortable
ApplicationLaboratory & Field Use
Conductivity Range0.0 – 1000 mS/cm
TDS Range0 – 1999 mg/L, 0 – 199.9 g/L
Resistivity Range0.00 – 20 MΩ·cm
Salinity Range0.0 – 70.0 (IOT-based)
Temperature Range–5.0 – 105.0 °C
Accuracy±0.5% of reading
Minimum Resolution0.001 µS/cm
Calibration1–5 point, auto-buffer recognition (DIN/NIST), electrode constant adjustment range: 0.090–25.000 cm⁻¹
Data Storage200 manual + 5000 interval-logged entries
IP RatingIP66/IP67
Auto-Temperature Compensation (ATC)Yes
DisplayBacklit graphical LCD
PowerUp to 1000 h battery life (non-backlit), 100 h (backlit continuous)
USB InterfaceWaterproof, PC data transfer compliant