BrandSartorius
OriginGermany
ModelMA100
Heating MethodInfrared (with optional halogen and quartz heating elements)
Readability0.1 mg
CertificationEC Type Approval for heating unit and weighing system
Drive MechanismMotor-driven integrated heating unit
OptionalBuilt-in thermal printer
Cleaning DesignPlug & Dry™ removable heating module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSartorius
OriginGermany
ModelMA160-1CN
Heating MethodInfrared
Application CategoryLaboratory & QC Moisture Analysis
Compliance ContextDesigned for GLP/GMP environments, supports 21 CFR Part 11–compliant data integrity workflows (when integrated with optional software)
Method Storage CapacityUp to 100 user-defined methods
Method Development Time≤45 minutes per new method (3-step guided workflow)
Cleaning DesignRemovable heating module and sample chamber base plate, dishwasher-safe
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelDSH-50A-5
Heating SourceHalogen Lamp
Weighing Range0–50 g
Readability5 mg
Temperature Range50–160 °C
Heating Time1–99 min (1-min increments)
Sample Capacity0.5–10 g (recommended: 3–10 g)
Repeatability (3 g sample)±0.3%
DisplayBacklit dot-matrix LCD
InterfaceRS232
Pan Diameter100 mm
Dimensions (W×D×H)265 × 160 × 150 mm
Net Weight5 kg
Gross Weight6 kg
End-point ModesTimed & Automatic
Heating ProfileStandard
Display OutputsMoisture %, Solid %, Sample Weight, Elapsed Time
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDeleite
OriginShanghai, China
ModelHE100-1
Heating SourceHalogen Lamp
Weighing Range0–100 g
Readability1 mg
Repeatability±0.30% (with 3 g sample)
Temperature Range40–180 °C
Heating Time1–99 min (1 min increments)
Sample Pan Diameter100 mm
Communication InterfaceRS232
Displayed Parameters% Moisture, % Solids, Time, Temperature, Weight, Date
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelDSH-10A
Heating MethodHalogen Lamp
DisplayHigh-Resolution Backlit Dot-Matrix LCD
InterfaceRS-232C
FeaturesAutomatic Tare, Zero Drift Compensation, Real-Time Dryness Monitoring
ComplianceDesigned for ISO 5725 (accuracy & reproducibility), ASTM E1447 (moisture in solids), and USP <921> (Loss on Drying)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDELEITE
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelDMS-4KEA
PriceUSD 2,150 (FOB Shanghai)
Heating MethodHalogen Lamp
Weighing Range0–110 g
Weighing Accuracy±0.001 g
Moisture Determination Range0.001–100%
Temperature Control Range40–200 °C
Typical Measurement Time≤8 min
Display7-inch capacitive touchscreen
Language SupportEnglish & Chinese
Built-in FunctionsAuto-tare, one-touch preheat, temperature calibration, label printing, silent cooling fan, dual-drive automatic door opening
Optional ConnectivityBluetooth 5.0 & Wi-Fi 802.11 b/g/n
User ManagementAdministrator & operator accounts with password protection
Internal CalibrationScheduled interval setting with audit trail
ComplianceASTM D4052, ISO 1183, USP <921>, GB/T 29246–2012
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelTSF-50A-5
Heating SourceHalogen Lamp
Display4.3-inch Capacitive Touchscreen LCD
Readability0.01% / 1 mg
ComplianceGB/T 29249–2012 (Electronic Moisture Analyzer Based on Drying Method)
InterfaceRS232 for Printer & PC Connectivity
Data OutputReal-time Drying Curve, Auto-finalization, Lock-on-Completion
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDeleite
OriginShanghai, China
ModelDR-506
Measurement PrincipleMicrobial Electrode Method
Standard ComplianceHJ/T 86–2002
Measuring Range2–50 mg/L (up to 4000 mg/L with dilution)
Repeatability≤10% RSD
Accuracy±5% of reading
Resolution0.1 mg/L
Sample Throughput Time5–8 min per sample
Sample Volume Required50 mL per assay
Flow RateConstant-flow continuous injection (5 mL/min buffer consumption)
Operating Temperature5–40 °C
Relative Humidity≤90% RH
Power SupplyAC 220 V, 50 Hz
Power Consumption100 W
Dimensions (W×D×H)560 × 360 × 210 mm
Net Weight16 kg (shipping weight ~20 kg)
Sample HandlingNo pretreatment required
Microbial SensorNon-pathogenic, immobilized nitrifying bacteria strain
Data OutputIntegrated thermal printer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelDSH-50A-1
Heating SourceHalogen Lamp
Readability1 mg
Weighing Range0–50 g
Repeatability (3 g sample)±0.2%
Recommended Sample Mass3–10 g
Heating Time Range1–99 min (1 min increments)
Temperature Range50–180 °C
Endpoint ModesTimed & Automatic
DisplayMoisture %, Solid %, Weight, Time, Date
Pan Diameter100 mm
Dimensions (W×D×H)265 × 160 × 150 mm
Net Weight5 kg
Gross Weight6 kg
InterfaceRS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandD&T
OriginTianjin, China
ModelEX-FH104A
Heating SourceHalogen Lamp
Weighing Range120 g
Readability0.1 mg
Repeatability (2 g sample)0.05% SD, ±0.1%
Repeatability (10 g sample)0.01% SD, ±0.05%
Moisture Readability0.001% MC
CalibrationFully Automatic Internal Calibration
Drying Temperature RangeSingle-Glass Mode: 40–160 °C
Dual-Glass Mode40–200 °C
Increment1 °C
Pan DiameterΦ90 mm
Dimensions (W × D × H)200 × 385 × 120 mm
Moisture Range0.01–100% MC
Method Storage300 methods
Result Storage3000 records
Heating ProgramsStandard, Stepwise, Rapid
Drying Termination ModesTimed, Auto (5 preset weight-loss thresholds + user-defined threshold)
Warm-up Time20–30 min
Display Modes%MC, %DC, g
Output InterfacesRS232/RS485, LAN, USB1 (data export/firmware update), USB2 (dedicated printer)
Touchscreen7-inch capacitive
Sensor TypeIntegrated electromagnetic force compensation sensor
DesignSeparated weighing and display units
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOHAUS
OriginUSA
ModelMB120
Heating MethodHalogen Lamp
Capacity120 g
Readability0.01% / 0.001 g
Repeatability0.05% (3 g sample) / 0.015% (10 g sample)
Moisture Range0.01–100% (Moisture), 0.01–1000% (Regain)
Temperature Range40–230 °C
Display4.3″ QVGA TFT Color Touchscreen
Sample Pan Diameter90 mm
Dimensions (W×H×D)211 × 180 × 355 mm
Net Weight5.23 kg
Power Supply240 VAC, 50/60 Hz
InterfaceRS232 (2 ports), USB Host (2 ports), USB Device
Operating Environment10–40 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSartorius
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelMA37-1CN
PriceUSD 2,950 (approx.)
Heating MethodInfrared Metal Heater
Maximum Sample Capacity70 g
Readability1 mg / 0.01%
Voltage115 V / 230 V AC
Moisture Range0.01–99.99%
Programmable MethodsYes
ComplianceDesigned for GLP/GMP environments with audit-ready operation log
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelDSH-100A-1
Heating SourceHalogen Lamp
Weighing Range0–100 g
Readability1 mg
Repeatability (3 g sample)±0.3%
Recommended Sample Mass3–10 g
Minimum Sample Mass0.5 g
Heating Time Setting1–99 min (1 min increments)
Temperature Range50–160 °C
End Point ControlTimer-based or Auto-termination
DisplayBacklit dot-matrix LCD showing moisture %, solids %, weight, elapsed time
Pan Diameter100 mm
Dimensions (W×D×H)265 × 160 × 150 mm
Net Weight5 kg
Communication InterfaceRS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelDSH-50A-1 Halogen Moisture Analyzer
Heating SourceHalogen Lamp
Readability1 mg
Weighing Range0–50 g
Repeatability (3 g sample)±0.2%
Recommended Sample Mass3–10 g
Heating Time1–99 min (1 min increments)
Temperature Range50–180 °C
End Point ModesTimed & Automatic
DisplayMoisture %, Solid %, Weight (g), Time, Date
Pan Diameter100 mm
Dimensions (W×D×H)265 × 160 × 150 mm
Net Weight5 kg
CommunicationRS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOHAUS
OriginUSA
ModelMB27ZH
Heating MethodHalogen Lamp
Capacity90 g
Readability1 mg / 0.01%
Pan Diameter90 mm
Part Number30128007
Dimensions (W×D×H)17 × 14 × 28 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSartorius
OriginGermany
ModelMA37
Heating MethodInfrared
Weighing Capacity70 g
Heating SourceMetal Heater
Power Consumption640 VA
Line Voltage115 V / 230 V
Line Frequency50 / 60 Hz
HoodRemovable with Wide Opening Angle & SoftClose Mechanism
Weighing Accuracy> 1 g: ±0.2 %
> 5 g±0.05 %
Recommended Moisture Range1–100 %