- All
- Favorite
- Popular
- Most rated
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 6251 |
| Temperature Range | −10 to +60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0 to 100 %RH |
| RH Accuracy | ±2.5 %RH (5–95 %RH) |
| RH Resolution | 0.1 %RH |
| Operating Ambient Temperature | −20 to +50 °C |
| Display | Backlit LCD |
| Power Supply | 9 V battery (approx. 70 h lifetime) |
| Dimensions | 182 × 64 × 40 mm |
| Weight | 195 g |
| Sensor Type | Integrated capacitive humidity sensor + NTC temperature sensor |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1911 |
| Instrument Type | Single-Channel HACCP-Compliant Temperature Data Logger |
| Dimensions | Ø20 × 59 mm |
| Installation | Portable / Immersible |
| Housing Material | Stainless Steel (AISI 316) + PEEK (Polyetheretherketone) |
| IP Rating | IP68 |
| Probe Sleeve Length | 25 mm |
| Probe Diameter | 3 mm |
| Measurement Range | −50 to +140 °C |
| Accuracy | ±0.2 °C (−50 to −40 °C), ±0.1 °C (−40 to +140 °C) |
| Resolution | 0.01 °C |
| Response Time (t₉₀) | 7 s |
| Sampling Interval | 1 s to 24 h |
| Memory Capacity | 60,000 readings |
| Battery | 1/2 AA lithium |
| Operating Life | 2,500 hours (at 10 s interval, +121 °C) |
| Storage Temperature | −20 to +50 °C |
| Sensor Type | Integrated Pt1000 RTD |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 0104 |
| Temperature Range | -50 to +250 °C |
| Accuracy | ±1.0 °C (-50 to -30.1 °C), ±0.5 °C (-30 to +99.9 °C), ±1% of reading (+100 to +250 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₉) | 10 s (in moving liquid) |
| Operating Temperature | -20 to +60 °C |
| Storage Temperature | -30 to +70 °C |
| IP Rating | IP65 |
| Probe Diameter | 3 mm |
| Probe Tip Diameter | 2.3 mm |
| Probe Sheath Length | 102 mm |
| Folded Dimensions | 163 × 47 × 20 mm |
| Extended Dimensions | 265 × 47 × 20 mm |
| Weight | 165 g (incl. batteries) |
| Power Supply | 2 × AAA batteries |
| Battery Life | 100 h (+25 °C, no backlight) |
| Display | Single-line LCD with backlight |
| Compliance | EN 13485, HACCP, EU Directive 2004/108/EC |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 1063 |
| Temperature Range | -50 to +275 °C |
| Accuracy | ±0.5 °C (-30 to +99.9 °C), ±1.0 °C (full range) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | -20 to +50 °C |
| Power Source | CR2032 lithium coin cell |
| Dimensions (L×W×H) | 215 × 34 × 19 mm |
| Weight | 80 g |
| IP Rating | IP67 (with protective sleeve 0516 8265) |
| Measurement Rate | 2 readings per second |
| Compliance | ISO/IEC 17025 traceable calibration options available |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 826-T4 |
| Type | Portable Dual-Mode Thermometer |
| Infrared Temperature Range | −50 to +300 °C |
| NTC Probe Temperature Range | −50 to +230 °C |
| IR Accuracy | ±1.5 °C (−20 to +100 °C), ±2 °C or ±2 % of reading (remaining range) |
| NTC Accuracy | ±0.5 °C (−20 to +99.9 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Resolution | 0.1 °C |
| NTC Resolution | 0.1 °C |
| IR Measurement Time | 0.5 s |
| NTC Measurement Time | 1.25 s |
| Optical Resolution | 6:1 |
| Laser Targeting | Single-point |
| IP Rating | IP67 (with protective sleeve) |
| Dimensions | 148 × 34.4 × 19 mm |
| Weight | 80 g |
| Operating Temperature | −20 to +50 °C |
| Storage Temperature | −40 to +70 °C |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 20 h |
| Display | Monochrome LCD, single-line |
| Compliance | EN 13485, HACCP-aligned |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9261 |
| Temperature Measurement Principle | Thermocouple (Type T & K) |
| Measurement Method | Contact |
| Temperature Range | -50 to +400 °C |
| Resolution | 0.1 °C (-50 to +199.9 °C), 1 °C (remaining range) |
| Accuracy | ±0.3 °C (-20 to +70 °C) |
| Stability | ±0.3 °C (-20 to +70 °C) |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| IP Rating | IP65 (with optional protective sleeve) |
| Dimensions | 177 × 64 × 40 mm |
| Weight | 182 g (incl. 9 V battery) |
| Battery Life | 200 h (backlight off), 68 h (backlight on) |
| Compliance | EN 13485, HACCP-ready |
| Data Logging | Max/Min auto-capture, user-defined alarm thresholds with audible alert |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9055 |
| Temperature Measurement Principle | K-type Thermocouple |
| Measurement Method | Contact |
| Temperature Range | −50 to +350 °C (short-term up to +500 °C) |
| Resolution | 0.1 °C |
| Accuracy | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Stability | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Response Time (t₉₉) | 10 s in water |
| Weight | 80 g |
| Dimensions (L×W×H) | 270 × 40 × 70 mm |
| Probe Sheath Length | 200 mm |
| Probe Tip Length | 4 mm |
| Probe Rod Diameter | 3 mm |
| Display | Single-line LCD |
| Operating Temperature | 0 to +40 °C |
| Storage Temperature | −20 to +70 °C |
| Housing Material | ABS |
| Power Supply | 3 × AAA batteries (rechargeable) |
| Battery Life | Up to 1000 h |
| CE Marking | 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1766 |
| Channel Count | 4-channel (2 internal + 2 external probe inputs) |
| Temperature Range | −20 °C to +70 °C |
| Temperature Accuracy | ±0.2 °C (−20 °C to +70 °C), ±0.4 °C (outside range) ±1 digit |
| Temperature Resolution | 0.1 °C |
| Humidity Range | 0–100 %RH |
| Humidity Accuracy | As specified per probe (capacitive sensor) |
| Humidity Resolution | 0.1 %RH |
| IP Rating | IP65 |
| Housing Material | Metal |
| Dimensions | 103 × 63 × 33 mm |
| Weight | 430 g |
| Operating Temperature | −20 °C to +70 °C |
| Storage Temperature | −40 °C to +85 °C |
| Battery Type | TL-5903 lithium battery |
| Battery Life | Up to 8 years (15-min measurement interval, +25 °C) |
| Memory Capacity | 2,000,000 measurement values |
| Measurement Interval | 1 s to 24 h |
| Data Interface | Mini-USB port, SD card slot |
| Compliance | EU Directive 2014/30/EU (EMC), 2011/65/EU (RoHS) |