| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MA204E/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability (typ.) | 0.08 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 160 mg |
| Stabilization Time | 2 s |
| Calibration | External |
| Interface | RS232, USB-A, Bluetooth (optional) |
| Display | LCD with hybrid touch control |
| Construction | Corrosion-resistant metal base and robust housing |
| Compliance | Legal-for-trade (OIML R76), USP <41>, GLP/GMP-ready |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Model | S321/S321W |
| Dimensions (L×D×H) | 800 mm × 615 mm × 1106–1292 mm |
| Filtration Efficiency | >99.995% for particles ≥0.3 µm (HEPA/activated carbon hybrid), leakage <0.1 µg/m³ (vs. OEL5 target) |
| Balance Sensitivity Support | up to 1 µg (10⁻⁶ g) |
| Installation | Ductless, freestanding, mobile-ready |
| Compliance | Meets ISO 14644-1 Class 5, ASTM D6377, USP <800>, and EU GMP Annex 1 requirements for OEB3–OEB5 handling |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 6251 |
| Temperature Range | −10 to +60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0 to 100 %RH |
| RH Accuracy | ±2.5 %RH (5–95 %RH) |
| RH Resolution | 0.1 %RH |
| Operating Ambient Temperature | −20 to +50 °C |
| Display | Backlit LCD |
| Power Supply | 9 V battery (approx. 70 h lifetime) |
| Dimensions | 182 × 64 × 40 mm |
| Weight | 195 g |
| Sensor Type | Integrated capacitive humidity sensor + NTC temperature sensor |
| Brand | D&A |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ES-J120D |
| Instrument Type | Density-Specific Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability | ±0.1 mg |
| Density Resolution | 0.0001 g/cm³ |
| Weighing Chamber Height | 210 mm |
| Pan Diameter | Φ90 mm |
| Operating Temperature Range | 13–25 °C |
| Operating Humidity Range | 20–85% RH (non-condensing) |
| Stabilization Time (Avg.) | ≤2.5 s |
| Warm-up Time | 30–60 min |
| Power Supply | 220 V AC / 50 Hz input |
| RS232 Baud Rates | 300, 600, 1200, 2400, 4800, 9600 |
| Construction | Stainless Steel Density Accessories |
| Compliance | Designed for GLP/GMP-aligned workflows, supports ASTM D792, ISO 1183, and USP <841> density determination protocols |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model Series | VLP |
| Instrument Type | Analytical Balance |
| Capacity Range | 20–6000 g |
| Readability | 10 mg / 100 mg / 1 g (model-dependent) |
| Calibration | External |
| Dimensions (W×D×H) | 270 × 190 × 110 mm |
| Pan Diameter | Ø130 mm or Ø160 mm (model-dependent) |
| Compliance | ISO 9001-manufactured |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | PX125DZH |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.01 mg (10 µg) |
| Repeatability | 0.02 mg / 0.1 mg (at full scale and 10% load, respectively) |
| Calibration | Internal and External |
| Display | Dual-line LCD with contextual prompts |
| Interface | USB-B and RS-232 |
| Construction | Die-cast aluminum base, stainless steel weighing pan |
| ESD Mitigation | Integrated red ESD removal bar above weighing chamber |
| Compliance | Designed to support GLP/GMP documentation workflows |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | NVT6200ZH |
| Instrument Type | General-Purpose Portable Balance |
| Maximum Capacity | 6200 g |
| Readability | 1 g |
| Repeatability | ±1 g |
| Calibration Method | External |
| Overload Protection | Up to 400% of rated capacity |
| Transport Lock | Integrated mechanical sensor lock |
| Compliance | Designed to meet ISO 9001 manufacturing standards and supports GLP/GMP documentation workflows |
| Brand | Dante / D&T |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ES-LMZ |
| Instrument Type | Precision Laboratory Balance for Coal Testing |
| Readability | 0.01 mg to 10 mg (model-dependent) |
| Calibration | isoCAL Fully Automatic Internal Calibration |
| Repeatability | 0.04 mg (at 5% load, ES-L55-MZ) |
| Sensitivity Drift | 5 ppm/K (10–30 °C) |
| Stabilization Time | ≤2.5 s |
| Weighing Pan Diameter | Φ48 mm (standard) or custom |
| Dimensions | 227.17 × 144.5 × 94.2 mm |
| Power Input | DC 24 V ±10%, 0.1 A |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 30–85% RH |
| Interface | RS232 / RS485 |
| Communication Protocols | DAT232, DAT485 (MODBUS-compatible), customizable |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1911 |
| Instrument Type | Single-Channel HACCP-Compliant Temperature Data Logger |
| Dimensions | Ø20 × 59 mm |
| Installation | Portable / Immersible |
| Housing Material | Stainless Steel (AISI 316) + PEEK (Polyetheretherketone) |
| IP Rating | IP68 |
| Probe Sleeve Length | 25 mm |
| Probe Diameter | 3 mm |
| Measurement Range | −50 to +140 °C |
| Accuracy | ±0.2 °C (−50 to −40 °C), ±0.1 °C (−40 to +140 °C) |
| Resolution | 0.01 °C |
| Response Time (t₉₀) | 7 s |
| Sampling Interval | 1 s to 24 h |
| Memory Capacity | 60,000 readings |
| Battery | 1/2 AA lithium |
| Operating Life | 2,500 hours (at 10 s interval, +121 °C) |
| Storage Temperature | −20 to +50 °C |
| Sensor Type | Integrated Pt1000 RTD |
| Brand | D&T |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP1204 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability (5% load) | ±0.2 mg |
| Repeatability (near full load) | ±0.3 mg |
| Linearity Error | ±0.3 mg |
| Calibration Method | Internal (isoCAL) |
| Stabilization Time | ≤3 s |
| Pan Diameter | Φ90 mm |
| Dimensions (W×D×H) | 210 × 310 × 315 mm |
| Draft Shield Height | 210 mm |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Temperature Drift | ≤5 ppm/°C |
| Warm-up Time | <15 min |
| Power Supply | 100–240 VAC, 50/60 Hz |
| DC Output | 12 VDC, 1 A |
| Communication Interface | RS232 (configurable baud rates: 300–9600) |
| Display | VA LCD |
| Environmental Compensation | Automatic temperature & time-triggered isoCAL |
| Shock Protection | Four-stage damping system |
| Accuracy Class | ISO 9001-compliant design |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | PX85ZH |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 82 g |
| Readability | 0.01 mg |
| Calibration | Internal Calibration |
| Minimum Weight (USP <0.1% typical) | 20 mg |
| Stabilization Time | 10 s |
| Pan Size | 80 mm |
| Display | Backlit Dual-Line LCD |
| Communication Interfaces | RS232, USB |
| Construction | Die-cast aluminum base, stainless steel pan, glass draft shield, underhook, removable dust cover, anti-theft lock |
| Operating Environment | 10–30 °C, ≤80% RH non-condensing |
| Net Weight | 4.5 kg |
| Dimensions (H×L×W) | 309 × 321 × 209 mm |
| Power Supply | Included AC adapter |
| Weighing Units | g, mg, kg, oz, oz t, lb, ct, N, momme, mesghal, tical, tola, grain, liang (HK/TW/SG), baniwit, taels |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 0104 |
| Temperature Range | -50 to +250 °C |
| Accuracy | ±1.0 °C (-50 to -30.1 °C), ±0.5 °C (-30 to +99.9 °C), ±1% of reading (+100 to +250 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₉) | 10 s (in moving liquid) |
| Operating Temperature | -20 to +60 °C |
| Storage Temperature | -30 to +70 °C |
| IP Rating | IP65 |
| Probe Diameter | 3 mm |
| Probe Tip Diameter | 2.3 mm |
| Probe Sheath Length | 102 mm |
| Folded Dimensions | 163 × 47 × 20 mm |
| Extended Dimensions | 265 × 47 × 20 mm |
| Weight | 165 g (incl. batteries) |
| Power Supply | 2 × AAA batteries |
| Battery Life | 100 h (+25 °C, no backlight) |
| Display | Single-line LCD with backlight |
| Compliance | EN 13485, HACCP, EU Directive 2004/108/EC |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | YP30002 |
| Type | Precision Laboratory Balance |
| Maximum Capacity | 3000 g |
| Readability | 10 mg |
| Calibration | Internal |
| Pan Diameter | 130 mm |
| Dimensions (W×D×H) | 270 × 190 × 110 mm |
| Power Supply | DC 6 V / 0.3 A (AC/DC adapter included |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 1063 |
| Temperature Range | -50 to +275 °C |
| Accuracy | ±0.5 °C (-30 to +99.9 °C), ±1.0 °C (full range) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | -20 to +50 °C |
| Power Source | CR2032 lithium coin cell |
| Dimensions (L×W×H) | 215 × 34 × 19 mm |
| Weight | 80 g |
| IP Rating | IP67 (with protective sleeve 0516 8265) |
| Measurement Rate | 2 readings per second |
| Compliance | ISO/IEC 17025 traceable calibration options available |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GC-C203 |
| Instrument Type | Precision Balance |
| Capacity | 200 g |
| Readability | 0.001 g (1 mg) |
| Internal Calibration | Yes |
| Display | Backlit BTN black-matrix LCD |
| Weighing Functions | Counting, Percentage Weighing, Dual-Range Mode, Unit Conversion (g, oz, ct, etc.) |
| Construction | Sealed draft shield enclosure |
| Sensor Technology | Electromagnetic force compensation sensor with CNC-machined components |
| Microprocessor | ARM32-bit embedded controller |
| Signal Processing | Digital filtering and adaptive data smoothing algorithms |
| PCB Assembly | SMT (Surface Mount Technology) |
| Compliance | Designed to meet ISO 9001 manufacturing standards |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 826-T4 |
| Type | Portable Dual-Mode Thermometer |
| Infrared Temperature Range | −50 to +300 °C |
| NTC Probe Temperature Range | −50 to +230 °C |
| IR Accuracy | ±1.5 °C (−20 to +100 °C), ±2 °C or ±2 % of reading (remaining range) |
| NTC Accuracy | ±0.5 °C (−20 to +99.9 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Resolution | 0.1 °C |
| NTC Resolution | 0.1 °C |
| IR Measurement Time | 0.5 s |
| NTC Measurement Time | 1.25 s |
| Optical Resolution | 6:1 |
| Laser Targeting | Single-point |
| IP Rating | IP67 (with protective sleeve) |
| Dimensions | 148 × 34.4 × 19 mm |
| Weight | 80 g |
| Operating Temperature | −20 to +50 °C |
| Storage Temperature | −40 to +70 °C |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 20 h |
| Display | Monochrome LCD, single-line |
| Compliance | EN 13485, HACCP-aligned |
| Brand | D&TC Dantec |
|---|---|
| Origin | Tianjin, China |
| Model | ES1200 |
| Maximum Capacity | 1200 g |
| Readability | 10 mg |
| Repeatability | ±10 mg |
| Linearity Error | ±10 mg |
| Stabilization Time | ≤2.5 s |
| Pan Diameter | Φ160 mm |
| Dimensions (W×D×H) | 210 × 310 × 90 mm |
| Operating Temperature | 13–25 °C |
| Operating Humidity | 10–70 % RH |
| Warm-up Time | 30–60 min |
| Power Input | 220 V AC / 50 Hz |
| Output | 7.5 V DC / 600 mA |
| RS232 Baud Rates | 300–9600 |
| Accuracy Class | Class II |
| Sensor Type | Gold-plated ceramic variable-capacitance transducer |
| Environmental Compensation | Integrated high-precision humidity & temperature sensors |
| Display | Backlit LCD with intuitive layout |
| Weighing Units | g, ct, oz, lb, etc. |
| Modes | Standard weighing, counting, percentage, checkweighing |
| Construction | Corrosion-resistant stainless-steel pan |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | VLF Series |
| Type | Analytical Balance |
| Capacity | 100 g / 120 g / 200 g / 220 g |
| Readability | 0.1 mg |
| Calibration | External (VLF-E models) or Internal (VLF-C models) |
| Stabilization Time | ≤2 s (fast mode) or ≤4 s (precision mode) |
| Pan Diameter | Φ85 mm |
| Dimensions (W×D×H) | 350 × 210 × 346 mm |
| Display | LED, with real-time ambient temperature indication |
| Leveling | Front-mounted bubble level |
| Interface | RS232C serial port |
| Data Management | Local storage & recall, PC connectivity via dedicated software, optional Bluetooth printer support |
| Weighing Modes | Standard weighing, counting, percentage, density (indirect), animal/weighing-in-motion (via software extension) |
| Units | g, mg, oz, ct, lb, etc. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MA3002/A |
| Maximum Capacity | 3.2 kg |
| Readability | 0.01 g |
| Repeatability (typ.) | 7 mg |
| Stabilization Time | 1 s |
| Pan Size (W×D) | 180 mm × 180 mm |
| Display | Backlit LCD with Touch Interface |
| Connectivity | RS232, USB-A, Optional Bluetooth |
| IP Rating | IP43 |
| Minimum Weight (USP <0.1%, k=2, typical) | 14 g |
| Minimum Weight (U=1%, k=2, typical) | 1.4 g |
| Dimensions (H×W×D) | 100 mm × 209 mm × 354 mm |
| Compliance | Verified for trade use, USP Chapter 41 & 1251, ISO/IEC 17025 traceable calibration support |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | YP6002 |
| Maximum Capacity | 600 g |
| Readability | 0.01 g (10 mg) |
| Accuracy Class | Class II (per OIML R76) |
| Calibration | Manual internal/external calibration |
| Weighing Units | g, oz, ct, lb, pcs, % |
| Connectivity | RS-232 interface (optional printer/PC connection) |
| Construction | Die-cast metal base with reinforced chassis |
| Compliance | CE, ISO 9001, GLP-compliant data logging capability |
| Brand | D&T |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | XE2.7S |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 2.1 g |
| Readability | 0.1 µg |
| Accuracy Class | Class I (per EU Directive 2014/31/EU) |
| Verification Scale Interval (e) | 1 µg |
| Minimum Weight (USP <41>) | 0.82 mg (recommended), 1.3 mg (typical) |
| Sensitivity Drift | 5 ppm/K (10–30 °C) |
| Tare Range | <100% of max capacity |
| Calibration | Internal (IsoCAL™ automatic temperature- and time-controlled calibration) |
| Stabilization Time | 8 s (typical) |
| Measurement Time | 12 s (typical) |
| Pan Diameter | Ø30 mm |
| Chamber Height | 80 mm |
| Dimensions (L×W×H) | 90 mm × 295 mm × 150 mm |
| Net Weight | ~4.7 kg |
| Operating Environment | 18–23 °C, 50–75% RH, temp. drift ≤1 °C/h |
| Power Supply | 100–240 VAC, 50/60 Hz, 0.5–1.0 A |
| Compliance | FDA 21 CFR Part 11 (ALCOA+ principles), GLP/GMP data integrity, OIML R111-1 E1 external calibration standard |
| Brand | D&T Corp |
|---|---|
| Origin | Tianjin, China |
| Model | ES8K |
| Maximum Capacity | 8000 g |
| Readability | 0.1 g |
| Repeatability | ±0.2 g |
| Linearity Error | ±0.2 g |
| Operating Temperature | 13–25 °C |
| Operating Humidity | 10–70 % RH |
| Response Time (avg.) | ≤2.5 s |
| Display Size | 185 × 100 mm |
| Pan Size | 370 × 310 mm |
| Dimensions (W×D×H) | 370 × 310 × 140 mm |
| Warm-up Time | 30–60 min |
| Power Supply | AC 220 V / 50 Hz → DC 7.5 V / 600 mA |
| Accuracy Class | Class II |
| Sensor Type | Gold-plated ceramic variable-capacitance transducer |
| Environmental Compensation | Integrated high-precision humidity & temperature sensors |
| Communication Interface | RS232 bidirectional |
| Weighing Modes | Standard, Piece Counting, Percentage, Checkweighing |
| Units | g, ct, oz, dwt |
| Construction | Anti-static, corrosion-resistant, spill-proof stainless steel pan and reinforced streamlined chassis |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MA204 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.08 mg |
| Calibration | Internal |
| Display | High-contrast LCD with large digits |
| Connectivity | RS232 interface for printers, auxiliary displays, and PCs |
| Weighing Modes | Standard weighing, piece counting, dynamic weighing, below-balance weighing |
| Mechanical Protection | Overload protection, metal base, integrated draft shield |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | LA204/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Accuracy (Linearity) | ±0.2 mg |
| Repeatability | ≤0.08 mg |
| Calibration | Internal motorized calibration with built-in weights |
| Weighing Units | g, mg, kg, oz, ct, etc. |
| Draft Shield | Integrated glass draft shield |
| Compliance | Designed to support GLP/GMP documentation requirements and ISO/IEC 17025-compliant workflows |