- All
- Favorite
- Popular
- Most rated
| Brand | Bioridge |
|---|---|
| Origin | Shanghai, China |
| Model | AP-8 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 5000 rpm |
| Max RCF | 2516 × g |
| Dimensions (L×W×H) | 300 mm × 250 mm × 195 mm |
| Net Weight | 15 kg |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 400 W |
| Cooling Method | Air-cooled |
| Tube Capacity | 1.5 mL / 2.0 mL microtubes |
| Control System | Microprocessor-based with automated positioning logic |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | MAGNUS 22 |
| Instrument Type | Floor-standing Centrifuge |
| Maximum Capacity | 4 × 750 mL |
| Maximum Speed | 14,300 rpm |
| Maximum RCF | 21,948 × g |
| Rotor Type | Horizontal (Swinging-Bucket) |
| Acceleration/Deceleration Control | Programmable PCBS with 175 selectable ramp profiles |
| Unbalance Detection | ULS (Unbalance Location System) with positional identification |
| Display | TFT color touchscreen (≥3 m visibility) |
| Timer Range | 1 s to 99 h, programmable in 1 s increments |
| Noise Level | <60 dB(A) |
| Motor | Brushless, maintenance-free |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| EU Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | TD5A |
| Centrifuge Type | Benchtop Low-Speed Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | 4390 × g |
| Max Capacity | 36 × 15 mL |
| Dimensions (L×W×H) | 460 mm × 540 mm × 340 mm |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 500 W |
| Weight | 28 kg |
| Speed Accuracy | ±30 rpm |
| Timer Range | 1 s – 99 min 59 s |
| Rotor Compatibility | 5 standard rotor types (horizontal, swing-out, fixed-angle, microplate, and multi-bucket configurations) |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 7,000 rpm ±5% |
| Max RCF | 3,286 × g |
| Rotor Capacity | Dual-configuration rotor — 12 × (0.2/0.5/1.5/2.0 mL tubes) or 4 × 8-position PCR strip carriers (0.2 mL) + 12 × (0.5/1.0 mL tubes) |
| Dimensions (W×D×H) | 185 × 180 × 135 mm |
| Noise Level | <47 dB(A) at max speed |
| Acceleration/Deceleration Time | <12 s / <15 s |
| Input Power | 25 W |
| Voltage | AC 100–240 V / DC 24 V |
| Operating Environment | 5–40 °C, ≤80% RH |
| Display | Fixed-speed LCD |
| Compliance | Designed for non-medical laboratory use per IEC 61010-1 safety requirements |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Digtor 22 C-U |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 22,000 rpm |
| Max RCF | 48,700 × g (calculated at 22,000 rpm with 100 mm rotor radius) |
| Max Capacity | 4 × 100 mL |
| Rotor Type | Fixed-angle |
| Application Class | Cellular & Bacterial Separation |
| Compliance | ASTM D91, D893, D2273, D2709, D5546 |
| Safety Certifications | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| EU Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Dimensions (W×D×H) | 640 × 650 × 400 mm |
| Net Weight | 77 kg |
| Power Supply | 220–230 V, 50–60 Hz |
| Power Consumption | 400 W |
| Noise Level | <60 dB(A) |
| Temperature Control Range | –10 °C to +40 °C |
| Display | TFT color touchscreen, readable at >3 m |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-36C |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–3600 rpm |
| Max RCF | 3100 × g |
| Rotor Configuration | Horizontal Swing-Out Rotor |
| Max Capacity | 4 × 1000 mL |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 750 W |
| Dimensions (L×W×H) | 715 × 550 × 435 mm |
| Weight | 90 kg |
| Safety | Electronic Lid Lock |
| Construction | Reinforced Polymer Housing |
| Compliance | Designed for GLP-compliant routine separation workflows |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-5C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–5000 rpm |
| Max RCF | 4500 × g |
| Max Capacity | 4 × 250 mL (horizontal rotor) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 460 mm × 450 mm × 680 mm |
| Net Weight | 80 kg |
| Construction | Reinforced polymer housing with electronic safety door lock |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DLT-HS165 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 16,500 rpm) |
| RCF Max | 23,669 × g |
| Max Capacity | 4 × 100 mL |
| Speed Accuracy | ±30 rpm |
| Timer Range | 1 min – 99 min 59 s |
| Display | LCD + Touch Panel Interface |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz, 10 A |
| Dimensions (L×W×H) | 330 mm × 420 mm × 280 mm |
| Net Weight | 20 kg |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5000B-II |
| Type | Benchtop Refrigerated Centrifuge |
| Max. Speed | 5000 rpm |
| Max. RCF | 5000 × g |
| Max. Capacity | 250 mL × 4 (horizontal rotor) |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Dimensions (L×W×H) | 460 mm × 510 mm × 680 mm |
| Net Weight | 245 kg |
| Rotor Type | Horizontal (swing-out) |
| Construction | Reinforced polymer housing |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TGL-16gR |
| Instrument Type | Benchtop Centrifuge |
| Cooling Function | Refrigerated (–20 °C to +30 °C) |
| Rotor Configuration | Fixed-Angle Rotor |
| Maximum Speed | 16,000 rpm |
| Maximum RCF | 17,000 × g |
| Capacity | 12 × 10 mL |
| Timer Range | 0–99 min |
| Power Consumption | 1.25 kW |
| Dimensions (L×W×H) | 640 × 460 × 370 mm |
| Weight | 77 kg |
| Housing Material | Reinforced Engineering Plastic |
| Safety | Electronic Door Lock |
| Centrifugation Class | General-Purpose High-Speed Refrigerated Centrifuge |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TXL-4.7 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 4700 rpm |
| Max RCF | 2300 × g |
| Rotor Capacity | 12 × 7 mL swing-bucket |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 380 × 350 × 360 mm |
| Weight | 20 kg |
| Construction | Reinforced polymer housing with electronic safety interlock door |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TGL-10K |
| Type | Benchtop Centrifuge |
| Cooling | Refrigerated |
| Drive System | Variable-Frequency Motor |
| Control Interface | Touchscreen LCD |
| Max Speed | 10,000 rpm |
| Max RCF | 8,950 ×g |
| Max Capacity | 50 mL × 4 (angle rotor) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 620 × 420 × 385 mm |
| Weight | 57 kg |
| Rotor Types | Fixed-angle rotors (1.5/2/5/10/50 mL configurations) |
| Safety | Electronic door lock, imbalance detection, auto lid lock |
| Brand | BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 21,000 rpm) |
| Max. Capacity | 4 × 750 mL |
| Max. RCF | 30,642 × g |
| Dimensions (L×W×H) | 495 mm × 620 mm × 445 mm |
| Weight | 60 kg |
| Speed Accuracy | ±10 rpm |
| Time Range | 1 s–99 min 59 s / 1 min–99 h 59 min |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 1.2 kW |
| Rotor Recognition | Yes |
| Safety Certifications | FDA Listed, GMP-Compliant Sealing (Food-Grade Silicone Elastomer) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PrepElite-GV |
| Automation Level | Fully Automated |
| Channel Configuration | Multi-channel |
| Extraction Mode | Column-based Solid Phase Extraction (SPE) |
| Flow Rate Control | Intelligent Precision Flow Control (0.1–100 mL/min) |
| Compatible Eluents | Multiple Organic Solvents (e.g., Methanol, Acetonitrile, Dichloromethane, Hexane) |
| Sample Capacity | Up to 96 Samples per Batch |
| Sample Loading Volume | 0.1–1000 mL (method-dependent) |
| Wetted Materials | Chemically Resistant Components (PTFE, 316L Stainless Steel) |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-60D |
| Type | Benchtop Centrifuge |
| Speed Range | 0–6000 rpm |
| Max RCF | 5000 ×g |
| Rotor Type | Fixed-Angle |
| Rotor Capacity | 15 mL × 12 |
| Horizontal Rotor Capacity | 50 mL × 6 |
| Temperature Control | None (Non-refrigerated) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 380 × 480 × 330 mm |
| Weight | 60 kg |
| Construction | Reinforced polymer housing with precision-machined rotor chamber |
| Safety | Electronic lid interlock system |
| Compliance | Designed to meet IEC 61010-1 safety requirements for laboratory electrical equipment |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Model | FC2516 w/R08 |
| Centrifuge Type | Benchtop High-Speed Centrifuge |
| Maximum Speed | 300–16,500 rpm |
| Maximum RCF | 19,080 × g |
| Maximum Capacity | 48 × 1.5/2.0 mL |
| Rotor Type | Fixed-Angle, Airtight (R08, Part No. 30694908) |
| Dimensions (W×D×H) | 245 mm × 280 mm × 380 mm |
| Motor | Brushless DC |
| Safety Features | Imbalance Detection, Automatic Rotor Recognition, Lid Interlock, Airtight Rotor Sealing (Dual-Silicone Gasket), Auto-Open Lid Post-Run |
| Compliance | Designed for GLP-compliant workflows |
| Software Capability | 9-Program Memory, 3-Step Sequential Protocol, Real-Time Speed Adjustment Without Stop |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | DLG-160AT |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 16,000 rpm) |
| Max. RCF | 23,669 × g |
| Max. Capacity | 6 × 50 mL |
| Dimensions (L×W×H) | 330 mm × 420 mm × 280 mm |
| Noise Level | <65 dB(A) |
| Speed Accuracy | ±30 rpm |
| Timer Range | 1 s – 99 min |
| Power Supply | AC 220 V, 50 Hz, 5 A |
| Power Consumption | 750 W |
| Rotor Type | Fixed-angle |
| Safety Certifications | FDA Registered, GMP-compliant sealing (food-grade silicone rubber seal), CE-marked electrical safety |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | TGL-18MS |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 18,000 rpm |
| Max RCF | 23,755 × g |
| Max Capacity | 4 × 100 mL (horizontal rotor) |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Speed Accuracy | ±30 rpm |
| Timer Range | 1 min–9 h 59 min (or 1 min–99 min) |
| Noise Level | <65 dB(A) |
| Dimensions (L×W×H) | 600 × 470 × 330 mm |
| Net Weight | 50 kg |
| Refrigerant | R134a |
| Power Supply | AC 220 V, 50 Hz, 15 A |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-5-Z |
| Type | Benchtop Centrifuge |
| Speed Range | 0–3500 rpm |
| Max RCF | 2602 × g |
| Rotor Type | Horizontal (Swinging-Bucket) |
| Max Capacity | 56 × 2/5 mL vacuum blood tubes |
| Cap-Removal Function | Fully automatic, 100% cap removal rate |
| Timer Range | 0–99 min |
| Noise Level | <70 dB(A) |
| Power Supply | 220 V, 50 Hz, 400 VA |
| Dimensions (L×W×H) | 505 × 450 × 425 mm |
| Weight | 56 kg |
| Construction | High-strength engineering plastic housing |
| Safety | Electronic door lock, imbalance detection, auto-stop on lid open |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-50D |
| Type | Benchtop Centrifuge |
| Speed Range | 0–5000 rpm |
| Max RCF | 3600 × g |
| Rotor Type | Fixed-Angle Rotor (15 mL × 8) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 595 × 400 × 360 mm |
| Weight | 60 kg |
| Construction | Reinforced Polymer Housing |
| Safety | Electronic Door Interlock |
| Cooling | None (Non-refrigerated) |
| Max Capacity | 100 mL × 4 (with optional horizontal rotor) |
| Drive System | Variable-Frequency Motor |
| Control Interface | Touchscreen LCD Panel |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | 800D |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 1430 ×g |
| Rotor Type | Fixed-Angle Rotor |
| Rotor Capacity | 15 mL × 6 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 520 × 375 × 335 mm |
| Net Weight | 45 kg |
| Construction | Reinforced polymer housing with electronic safety door lock |
| Cooling | Non-refrigerated (ambient-temperature operation) |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | KA-1000D |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2220 ×g |
| Rotor Type | Fixed-Angle |
| Rotor Capacity | 15 mL × 8 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 520 × 375 × 335 mm |
| Weight | 45 kg |
| Construction | Reinforced polymer housing with electronic safety door lock |
| Control System | Frequency-converter motor with capacitive touch panel interface |
| Compliance | Designed for GLP-compliant routine separation tasks in academic and QC laboratories |
| Brand | Shanghai Anting |
|---|---|
| Origin | Shanghai, China |
| Model | LXJ-IIC |
| Type | Benchtop Centrifuge |
| Category | Low-Speed Refrigerated Centrifuge |
| Rotor Type | Swing-Bucket (Horizontal) |
| Max Speed | 3600 rpm |
| Max RCF | 3040 ×g |
| Max Capacity | 5 mL × 120 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 750 W |
| Dimensions (L×W×H) | 650 mm × 550 mm × 770 mm |
| Weight | 160 kg |
| Construction | Reinforced polymer housing with electronic lid lock |
| Cooling | Refrigerated operation |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | GL-20B |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 20,000 rpm |
| Max RCF | 43,825 × g |
| Max Capacity | 6 × 500 mL |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz |
| Total Power | 3 kW |
| Dimensions (L×W×H) | 790 × 665 × 950 mm |
| Weight | 277 kg |
Show next