BrandYoke
OriginShanghai, China
ModelFP6450
Detection ElementsK, Na, Li, Ca, Ba
Detection LimitsK: 0.001 mmol/L
Na0.001 mmol/L
Li0.005 mmol/L
Ca0.01 mmol/L
Ba0.02 mmol/L (typical)
Response Time<8 s
RepeatabilityRSD ≤1.5%
Sample Uptake Rate6–8 mL/min
Display7-inch capacitive touchscreen LCD
Data StorageUp to 10-point calibration curves and 200 sample results
ConnectivityUSB port, USB flash drive export, cloud-enabled data synchronization
Safety FeaturesAutomatic flame-out detection, gas leak alarm
Calibration ModesLinear and piecewise linear (broken-line)
Power SupplyAC 220 V ±10%, 50 Hz ±1 Hz
Rated Power30 W
PrinterOptional external thermal printer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelFP6440
Detection ElementsK, Na, Li, Ca
Detection LimitsK: 0.001 mmol/L
Na0.001 mmol/L
Li0.005 mmol/L
Ca0.01 mmol/L
Response Time<8 s
RepeatabilityRSD ≤1.5%
Nebulization Flow Rate6–8 mL/min
Display7-inch capacitive touch LCD
Safety FeaturesFlame-out protection, gas leakage alarm
Data InterfaceUSB port, U-disk export, PC connectivity
Cloud ConnectivityYes
Calibration FunctionAutomatic correlation coefficient calculation
Optional AccessoryThermal printer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelFP6432
Measurement RangeK: 0–100 µg/mL
Na0–100 µg/mL
Ba0–3000 µg/mL
Detection LimitK ≤ 0.004 mmol/L
Response Time< 8 s
Repeatability≤ 3%
Sample Flow Rate< 6 mL/min
Wavelength AccuracyK/Li/Ca/Ba ≤ ±7 nm
Bandwidth (FWHM)≤ 15 nm for all elements
Background Transmittance≤ 0.5%
Power SupplyAC 220 ± 22 V, 50 ± 1 Hz
Rated Power30 W
Display7-inch capacitive touch LCD
Data Storage10-point calibration curves (max), 200 sample records
ConnectivityUSB port, U-disk export, cloud-enabled interface
Safety FeaturesFlame-out detection, gas leak alarm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoke
OriginShanghai, China
ModelFP6431
Detection ElementsK, Na, Ca
Detection LimitsK: 0.001 mmol/L
Na0.001 mmol/L
Ca0.01 mmol/L
Response Time≤5 s
RepeatabilityRSD ≤1.5%
Sample Flow Rate6–8 mL/min
Display7-inch capacitive touch LCD
Data ExportUSB port & U-disk support
Safety FeaturesFlame-out protection & gas leakage alarm
Operating Temperature10–35 °C
Relative Humidity≤85% RH
Power SupplyAC 220 V ±10%, 50 Hz, 250 W