Empowering Scientific Discovery

Yuanheng International Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeiou
OriginShanghai, China
ModelSKD-2000
Instrument TypeKjeldahl Nitrogen Determinator
Automation LevelFully Automated
Nitrogen Determination Range0.1–300 mg N
Sample Weight CapacitySolids 0.1–5 g
Distillation Time per Sample2–6 min
Repeatability≤ ±0.3% RSD
Recovery Rate≥99.8%
Linearity Range0.1–300 mg N
Linearity Error at 4× Nitrogen Load≤ ±0.8%
Compatible Standard Acid Concentration0.01–1.0 mol/L HCl or H₂SO₄
Power Consumption~1800 W
Dimensions (L×W×H)500×450×600 mm
Titration Precision±0.15%
Adjustable Alkali Addition Steps1–10 segments with 0–15 s intervals
Delay Time Setting0–1800 s
Reagent Pump Volume Range0–150 mL (1 mL resolution)
Distillation Steam ContinuityContinuous steam generation with auto-refill without interruption
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeiou
OriginShanghai, China
ModelSKD-5000
Instrument TypeFully Automated Kjeldahl Nitrogen Determinator
Nitrogen Determination Range0.1–500 mg N per sample
Cation Exchange Capacity (CEC) Range1–100 cmol/kg
Sample WeightSolid (e.g., soil): 0.5–10 g
Liquid1–100 mL
Distillation Time2–5 min per sample
Repeatability≤±0.2% for nitrogen
Recovery Rate≥99.8% for nitrogen
Linear Range0.1–500 mg N
Linearity Error at 4× Nitrogen Load≤±0.5%
Compatible Standard Acid Concentration0.01–1.5 mol/L HCl or H₂SO₄
Power Consumption~2000 W
Dimensions (L×W×H)~550×500×650 mm
Titration Resolution0.8 µL/step
Pump AccuracyRSD <0.002 µL/step
Repeatability (RSD)<0.5%
Delay Time Setting0–1800 s
Digestion Tube Compatibility300 mL and 650 mL tubes
Dual-Mode OperationManual & Automatic
Distillation PowerAdjustable
Safety FeaturesReal-time distillation cup temperature monitoring, condenser water flow/pressure auto-detection, acid/alkali/boric acid/diluent level sensors, door-closed status verification, dry-burn prevention via dual liquid-level modeling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeiou
OriginShanghai, China
ModelSKD-1000
Instrument TypeKjeldahl Nitrogen Determinator
Automation LevelFully Automated
Nitrogen Determination Range0.1–200 mg N per sample
Distillation Time3–8 min per sample
Repeatability≤ ±0.5% RSD
Sample Weight CapacitySolids 0.1–2 g
Nitrogen Recovery Rate≥99.5%
Power Consumption~1500 W
Dimensions (L×W×H)450 × 400 × 550 mm
Linear Range0.1–200 mg N
Linearity Error at 4× Nitrogen Load≤ ±1%
Compatible Standard Acid Concentrations0.01–0.5 mol/L HCl or H₂SO₄
Titration Resolution0.8 µL/step
Acid Delivery Precision≤0.002 µL/step
Alkali AdditionProgrammable segmented dosing (1–10 pulses, 0–15 s interval)
Delay Time Setting0–1800 s (for nitrate-nitrogen analysis)
Reagent Pump Volume Range0–150 mL (1 mL increments)
Steam Power AdjustmentContinuously variable
Safety FeaturesDual-level steam chamber monitoring, condensate flow interruption protection, door interlock sensing, real-time cooling water pressure/flow detection, reagent level monitoring, and jacket temperature control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeiou
OriginShanghai, China
ModelSKD-1800
Instrument TypeKjeldahl Nitrogen Determinator
Automation LevelFully Automated
Nitrogen Determination Range0.1–240 mg
Distillation Time per Sample3–8 min
Repeatability (RSD)≤0.5%
Sample Weight Capacity≤5 g (solid) or ≤15 mL (liquid)
Nitrogen Recovery Rate≥99.5%
Power Consumption750–1500 W
Dimensions (L×W×H)370 × 300 × 680 mm
Linearity Range0.1–240 mg nitrogen
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeiou
OriginShanghai, China
ModelSKD-1100
Instrument TypeKjeldahl Nitrogen Determinator
Automation LevelFully Automated
Nitrogen Determination Range0.1–200 mg N
Linear Range0.1–200 mg N
Sample Weight (Solid)0.1–5 g
Distillation Time per Sample3–5 min
Repeatability≤0.5% CV
Recovery Rate≥99.5%
Power Consumption~800 W
Dimensions (L×W×H)450 × 350 × 500 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelLeici KDN-1
Instrument TypeKjeldahl Nitrogen Determinator
Automation LevelFully Automated
Nitrogen Determination Range0.1 mg – 240 mg N
Steam Distillation TimeProgrammable up to 60 min
Sample Weight Capacity≤6 g (solid), ≤16 mL (liquid)
Nitrogen Recovery Rate≥99.5%
Power Consumption1.3 kW
Dimensions (L×W×H)400 mm × 385 mm × 735 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDELEITE
OriginShanghai, China
ModelAKN-3240
Automation LevelFully Automated
Nitrogen Determination Range0.01–240 mg N per sample
Distillation Time0–9 min/sample
Titration PrecisionRSD < 0.0012 µL/step
Minimum Titration Volume1–20 µL/step (auto-adjusted based on standard acid concentration)
Recovery Rate>99.5%
Power Adjustment Range0–1500 W
LinearityRSD <1.0% across 1× to 4× sample mass (same matrix)
Repeatability (RSD)<0.5%
Digestion Tube CompatibilityØ42 × 300 mm (supports both 300 mL and 650 mL tubes)
Data Storage Capacity≥200,000 sample records (≥7 years at typical lab throughput)
ComplianceSupports audit-trail-enabled operation per GLP/GMP requirements
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0