Empowering Scientific Discovery

Yuanheng International Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanghai Shen
OriginShanghai, China
ModelDZ10Z
Instrument TypeSub-boiling Distiller
Heating MethodCopper Immersion Heating Element
Cooling MethodHelical Coil Condenser
Distillation Rate≥10 L/h
Power Supply3-phase 380 V / 50 Hz
Rated Power7.5 kW
Construction MaterialAISI 304 Stainless Steel
Safety FeaturesAutomatic Low-Water Cut-off, Recirculating Cooling Water System, Drain Valve for Concentrate Removal
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeiou
OriginShanghai, China
ModelSKD-180
Heating MethodElectric (stainless steel heating element)
Cooling MethodRecirculating water cooling
Distillation Speed5–8 min per 250 mL sample
Warm-up Time10–15 min
Endpoint ControlQuantitative volume detection + automatic termination
Heating PowerAdjustable up to 1500 W
Distillation Flow Rate15–30 mL/min
Sample Capacity≤20 g (solid) or ≤30 mL (liquid) per run
Nitrogen Measurement Range0.1–240 mg N
Recovery Rate>99.5%
RepeatabilityRSD ≤0.5%
Data Storage10 programmable distillation/acid-addition protocols
Safety FeaturesReal-time liquid level monitoring, overpressure protection, dry-run prevention, emergency stop
Housing MaterialMolded ABS engineering plastic (acid- and alkali-resistant)
TubingCustom corrosion-resistant polymer tubing (rated for long-term HCl/NaOH exposure)
Power SupplyAC 220 V ±10%, 50 Hz
Water Supply Requirement≥0.15 MPa pressure, inlet temperature <20 °C
Net Weight15 kg
Dimensions (W×D×H)370 × 300 × 680 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeiou
OriginShanghai, China
ModelSKD-3800
Instrument TypeQuartz Glass Distillation Apparatus
Heating MethodElectric heating (stainless steel heating element)
Cooling MethodRecirculating water cooling
Distillation Rate15–30 mL/min (adjustable)
Heating-up Time10–15 min
End-point ControlQuantitative volume-based automatic termination
Steam Power750–1500 W (adjustable)
Dimensions~370 × 300 × 680 mm
Housing MaterialAcid- and alkali-resistant ABS
Nitrogen Detection Range0.1–210 mg per sample
Sample Capacity≤5 g solid or ≤15 mL liquid per run
Distillation Time per Sample3–9 min
RSD≤0.5%
Recovery Rate≥99.5%
Reagent Dispensing Accuracy±0.05 mL
Titration Range0–99 mL standard acid (with 10× acid replacement capability)
Display10.1-inch touchscreen with Chinese UI
Data OutputThermal printer + USB export + LIMS-compatible interface
Safety FeaturesDry-run protection for steam generator, condensate flow & temperature monitoring, reagent level sensing, safety door & digestion tube presence detection, condensate interruption shutdown
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYarong
OriginShanghai, China
ModelSZ-96A
Distillation Rate1800 mL/h
Heating MethodQuartz Tube Heating
Cooling MethodClosed-Loop Condensation System (Water Path Metal-Free)
Endpoint ControlDual-Sensor System (Temperature Controller + Reed-Type Water Level Sensor) with Relay Protection
Power1.5 kW
Voltage220 V / 50 Hz
Dimensions (L×W×H)70 × 20 × 68 cm
Weight5.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYarong
OriginShanghai, China
ModelSZ-93
Distillation Rate1600 mL/h
Heating MethodQuartz Tube Heater
Cooling MethodClosed-Loop Condensation System (Metal-Free Pathway)
Endpoint ControlDual-Sensor System (Temperature Controller + Reed-Type Water Level Sensor) with Relay Protection
Construction MaterialsStainless Steel Frame, Engineering Thermoplastics, Borosilicate & Fused Quartz Glass Components
ComplianceDesigned for GLP-Compliant Laboratory Environments
Instrument TypeStandard Quartz Glass Distillation Unit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanghai Shen
OriginShanghai, China
ModelDZ5Z
Instrument TypeSub-boiling Distiller
Heating MethodElectric (Stainless Steel Immersion Heater)
Cooling MethodTap Water Circulation
Distillation Rate5 L/h
Warm-up Time20–30 min
Endpoint ControlManual
Power SupplyAC 220 V / 50 Hz
Rated Power4.5 kW
Safety FeatureAutomatic Dry-run Protection (Water-Level-Dependent Power Cutoff)
Condenser TypeCoiled Tube Design
Water RecoveryCondensate Return to Evaporation Chamber
Drain ValveIntegrated Concentrate Drain
Construction MaterialFull 304 Stainless Steel Body and Components
Net Weight7 kg
Packing Dimensions35 × 34 × 78 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYarong
OriginShanghai, China
ModelSZ-97
Distillation Rate1500 mL/h
Heating MethodQuartz Tube Heater
Cooling MethodCirculating Water Condensation System (Metal-Free Pathway)
Endpoint ControlDual-Sensor System (Temperature Controller + Reed-Type Water Level Sensor) with Relay-Based Power Cut-Off Protection
Construction MaterialHigh-Purity Fused Quartz (Distillation Chamber & Condenser)
ComplianceDesigned for GLP-Compatible Laboratory Water Purification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYarong
OriginShanghai, China
ModelSZ-93A
Distillation Rate1600 mL/h
Input Power3.0 kW
Voltage/Frequency220 V / 50 Hz
Dimensions (L×W×H)70 × 34 × 80 cm
Weight10 kg
Heating MethodQuartz Tube Heater
Cooling MethodRecirculating Condensation System
Material Contact PathAll-Quartz + High-Purity Borosilicate Glass + Non-Metallic Structural Components
Safety ControlsBimetallic Temperature Controller + Reed-Type Water-Level Sensor + Relay-Based Dry-Run Protection
ConstructionStainless Steel Frame with Engineering Plastic Mounting Hardware + Heat-Resistant Insulation Jacket
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYarong
OriginShanghai, China
ModelSZ-93-1
Distillation Rate1600 mL/h
Heating MethodQuartz Tube Heater
Cooling MethodRecirculating Condensation System
Endpoint ControlDual-sensor (Temperature Controller + Reed-Type Water Level Sensor) with Relay Protection
Power Input3 kW
Voltage/Frequency220 V / 50 Hz
Dimensions (L×W×H)70 × 34 × 80 cm
Weight10 kg
ConstructionHigh-Purity Quartz Glass Body & Condenser
Instrument TypeBenchtop Automatic Dual-Distillation Unit for High-Purity Water Production
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYarong
OriginShanghai, China
ModelSZ-96
Distillation Rate1800 mL/h
Heating MethodQuartz Tube Heater
Cooling MethodRecirculating Condensation System
End-Point ControlDual-mode via Temperature Controller + Reed-Type Water Level Sensor with Relay Protection
Heating ElementIntegrated Quartz Tube Heating Unit
Construction MaterialHigh-Purity Quartz Glass Body
Instrument TypeBenchtop Automatic Distiller for Purified Water Production
ComplianceDesigned for GLP-compliant laboratory environments requiring trace-metal-free water
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYarong
OriginShanghai, China
ModelSZ-97A
Instrument TypeStandard Quartz Glass Distillation Apparatus
Heating MethodQuartz Tube Heating
Cooling MethodCirculating Condensation System
Distillation Rate1500 mL/h
Endpoint ControlTemperature Controller + Reed-Type Water Level Sensor with Relay Protection
Heating ElementQuartz Tube Heater
Input Power4.5 kW
Voltage/Frequency220 V / 50 Hz
Dimensions (L×W×H)78 × 45 × 90 cm
Net Weight15.8 kg
Construction MaterialsStainless Steel Body, Engineering Plastic Clamps & Supports, Borosilicate Glass Control Panel & Flask Housing
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0