- All
- Favorite
- Popular
- Most rated
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-4A |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.5–20 °C/min |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ±0.5 °C |
| Capillary Dimensions | OD Φ1.4 mm, ID Φ0.9 mm |
| Sample Capacity | 3 samples |
| Temperature Resolution | 0.1 °C |
| Brand | YDWG (Shanghai Physical Optics) |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-4 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | Adjustable, up to 320 °C |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ≤±1 °C (<200 °C) |
| Capillary Tube Length | 90 mm |
| Sample Capacity | 1 sample |
| Temperature Resolution | 1 °C |
| Display | LED digital readout (0.1 °C minimum increment) |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | 80 W |
| Optical Configuration | Binocular stereomicroscope with 45° inclined dual eyetubes, adjustable interpupillary distance and right-eye diopter compensation |
| Total Magnification | 40× (4× objective + 10× eyepiece) |
| Working Distance | Optimized for thermal stage integration |
| Brand | YAMATO |
|---|---|
| Origin | Japan |
| Model | DKN313C |
| Instrument Type | Benchtop |
| Temperature Range | Ambient +10°C to 260°C |
| Temperature Uniformity | ±1.0°C (at setpoint) |
| Temperature Fluctuation | ±0.5°C |
| Heating Rate | ~60 min (from ambient to 210°C) |
| Chamber Volume | 27 L |
| Brand | BM |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-1 |
| Temperature Range | 50–320 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.3, 4.5 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.2 °C/min), ±0.3 °C (at 1.0 °C/min) |
| Temperature Accuracy | ±0.5 °C (<200 °C), ±0.8 °C (≥200 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Temperature Resolution | 0.1 °C |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | WNE-1A |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±0.2 °C |
| Standard Water Value | (51 ± 1) s |
| Effluent Volume | (200 ± 0.2) mL |
| Heating Power | 550 W (AC 220 V, 50 Hz) |
| Compliance | GB/T 266, GB/T 514, Q/YXYY11 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2TLV |
| Viscosity Range | 1–200 mPa·s |
| Instrument Type | Benchtop (Not Online) |
| Operating Environment | Ambient Temperature |
| Software | RheoCalc T v3.x |
| Compliance | FDA 21 CFR Part 11 (Electronic Signatures, User Access Control, Audit Trail) |
| Data Storage | Password-Protected Local Database |
| Test Modes | Single-Point, Ramp, Hold, Cycle |
| Mathematical Models | Bingham, Casson, Power Law, Herschel-Bulkley |
| Multi-Sample Comparison | Up to 5 Data Sets |
| Temperature Control | Not Integrated (Requires External Bath or Peltier Accessory) |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XRY-1C |
| Measurement Mode | Isoperibol (Constant-Temperature Jacket) |
| Instrument Type | Oxygen Bomb Calorimeter |
| Intelligence Level | Fully Automated with PC Control |
| Temperature Range | 5°C to 35°C |
| Temperature Detection Threshold | 0.001°C – 0.01°C |
| Temperature Resolution | 0.0001°C |
| Temperature Stability | ≤0.001°C per 30 min |
| Temperature Tracking Rate | ~0.01°C/s – 0.05°C/s |
| Single-Sample Test Duration | ~8 min (Standard Mode), ~3 min (Rapid Mode) |
| Bomb Pressure Rating | 20 MPa |
| Pressure Resolution | 0.001 MPa |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-5 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ±0.5 °C (<200 °C), ±1 °C (≥200 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 0.9 mm |
| Sample Capacity | 3 samples |
| Temperature Resolution | 0.1 °C |
| Brand | MyiP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | NDJ-1 |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–1×10⁵ mPa·s |
| Accuracy | ±5% (for Newtonian fluids) |
| Rotors | No. 0 (optional), No. 1–4 |
| Rotational Speeds | 6, 12, 30, 60 rpm |
| Compliance | GB/T 265–1988 |
| Dimensions | 280 × 290 × 450 mm |
| Sample Temperature Control | External bath required (no integrated Peltier or heater) |
| Brand | MyiP |
|---|---|
| Origin | Shanghai, China |
| Model | DV-1 |
| Instrument Type | Benchtop Fixed Rotational Viscometer |
| Viscosity Range | 1–2×10⁶ mPa·s |
| Accuracy | ±2% (for Newtonian fluids) |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Spindles | LV#1, #2, #3, #4 |
| Operating Environment | Ambient temperature |
| Compliance | Conforms to GB/T 265 and JJG 1002 national standards for kinematic and dynamic viscosity measurement |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | 6811 |
| Instrument Type | Benchtop Viscometer |
| Viscosity Range | 1–2,000 mPa·s (with ULA adapter) |
| Torque Range | 0.0–100.0% (recommended: 10.0–100.0%) |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Rotational Speed | 0.5–250 rpm (20 discrete steps) |
| Viscosity Resolution | 0.01 mPa·s (≤100 mPa·s), 0.1 mPa·s (100–10,000 mPa·s), 1 mPa·s (>10,000 mPa·s) |
| Viscosity Accuracy | ±1% of full scale |
| Power Supply | 4 × AA alkaline batteries (DC 6 V) or AC adapter (100–240 V AC) |
| Battery Life | ~7 hours (continuous operation at 60 rpm) |
| Data Interface | USB to PC |
| Operating Environment | 10–40 °C ambient, 10–40 °C sample temperature |
| Compliance | Designed for ISO 2555 and ASTM D2196-compliant viscosity measurement workflows |