| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 191-T2 HACCP |
| Measurement Range | −50 to +140 °C |
| Accuracy | ±0.2 °C (−50 to −40 °C), ±0.1 °C (−40 to +140 °C) |
| Resolution | 0.01 °C |
| Probe Length | 115 mm |
| Probe Diameter | 3 mm |
| Housing Diameter × Height | 20 × 59 mm |
| IP Rating | IP68 |
| Sensor Type | Pt1000 |
| Response Time t₉₀ | 6 s |
| Memory Capacity | 60,000 readings |
| Battery | 1/2 AA lithium |
| Battery Life | 2,500 h (10 s interval at +121 °C) |
| Operating Temperature | −50 to +140 °C |
| Storage Temperature | −20 to +50 °C |
| Measurement Interval | 1 s to 24 h |
| Certifications | CE |
| Brand | The Great Wall |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CLZZ-50 |
| Vacuum Level | −0.098 MPa (98 kPa) |
| Operating Pressure Range | −0.1 MPa to 0.0 MPa |
| Temperature Range | −80 °C to +200 °C |
| Construction Material | Borosilicate Glass 3.3 (DIN ISO 3585) |
| Frame Material | Powder-Coated Q235 Steel + Anodized 6061-F Aluminum |
| Mobility | Locking Casters with Brake |
| Capacity | 50 L |
| Compliance | Designed for GLP-compliant laboratory filtration workflows |
| Brand | MICHEM (MechaTech) |
|---|---|
| Origin | United Kingdom |
| Model | Hyscan II |
| Measurement Principle | Quantitative Pressure-Reduction Solidification Method |
| Analysis Time | ≤ 5 min per sample |
| Detection Limit | 0.01 cm³/100 g Al |
| Accuracy | ±<5% RSD |
| Compliance | Designed for GLP/GMP-aligned foundry QA workflows |
| Portability | Benchtop with integrated vacuum system and field-deployable rugged chassis |
| Brand | Beijing Liuyi / LY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model No. | 130-0360 |
| Pricing | Available Upon Request |
| UV Emission Wavelengths | 254 nm (reflective), 365 nm (reflective), 302 nm (transmissive) |
| Transillumination Area | 200 × 200 mm |
| UV Lamp Power | 8 W (302 nm), 6 W (254/365 nm) |
| White Light Illumination | >100 lx, 200 × 200 mm area |
| UV Irradiance | ≥10 µW/cm² per wavelength |
| Dimensions (W × D × H) | 425 × 430 × 380 mm |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYD-0607 |
| Pricing | Upon Request |
| Operating Mode | Dual-channel |
| Filtration Method | Adjustable Vacuum Pump Suction |
| Filter Membrane | Glass Fiber, 0.65 µm Pore Size |
| Solvent | Trichloroethylene (TCE) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | ≤100 W |
| Ambient Operating Temperature | 15–35 °C |
| Relative Humidity | ≤85% |
| Dimensions (L×W×H) | 420 × 320 × 360 mm |
| Net Weight | 8.8 kg |
| Brand | Kylin-Bell |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | QB-118 |
| Instrument Type | Wrist-Action Shaker |
| Timing Range | 0–120 min or Continuous Operation |
| Oscillation Frequency | 10–80 rpm |
| Oscillation Amplitude | 2.0 ± 0.1 mm |
| Platform Configuration | Single Integrated Wrist-Motion Platform |
| Operating Angle | 30° |
| Power Supply | 110–220 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 240 × 390 × 240 mm |
| Net Weight | 7 kg |
| Brand | Hamilton |
|---|---|
| Origin | USA |
| Model | GFGJ-81000 |
| Capacity | 10–500 µL |
| Needle Gauge Options | 26s (OD 0.47 mm, ID 0.13 mm), 22s, 22 (OD 0.72 mm, ID 0.41 mm), 25 |
| Needle Length | 2 in (51 mm) |
| Volume per Inch (26s) | 0.26 µL/in |
| Volume per Inch (22) | 3.35 µL/in |
| Type | N-type (fixed needle, gas-tight plunger seal) |
| Brand | Supmile |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KBS-650 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 20 kHz |
| Maximum Ultrasonic Power Output | 650 W |
| Adjustable Power Range | 0–100% |
| Sample Volume Capacity | 0.5–500 mL |
| Processing Volume per Cycle | Up to 600 mL |
| Probe Diameter Options | Φ2, Φ3, Φ8 (standard), Φ10, Φ12, Φ15 mm |
| Duty Cycle Adjustment | 1–999 s |
| Timer Range | 0–24 h |
| Transducer Material | TC4 Titanium Alloy |
| Safety Features | Overload Protection, Audible/Visual Alarm, LED Illuminated Touch Interface, Motorized Vertical Probe Positioning with Wireless Remote Control |
| Structural Design | Modular Stackable Assembly (Optional Integrated or Separated Generator–Transducer Configuration) |
| Brand | Shanghai Shen |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region | Domestic (China) |
| Model | FY50 |
| Pricing | Upon Request |
| Construction | Stainless Steel (AISI 304) |
| Power Supply | ~220 V / 50 Hz |
| Heating Power | 3.8 kW |
| Chamber Volume | 50 L |
| Minimum Water Supply Pressure | ≥0.20 MPa |
| Maximum Operating Pressure | ≤0.35 MPa |
| Temperature Range | Ambient +5 °C to 135 °C |
| Programmable Holding Time | 1–99 min or 1–99 h |
| Internal Temperature Uniformity | ±1.5 °C |
| Dimensions (W×D×H) | 155 × 66 × 100 cm |
| Packing Size (Wooden Crate) | 76 × 86 × 118 cm |
| Safety Features | Dual-limit thermal cutoff (±2 °C over setpoint), pressure relief valve (0.23 MPa), low-water auto-refill with audible/visual alarm, gravity-assisted steam exhaust, radial self-sealing silicone gasket, integrated cold-water spray cooling system (135 °C → ambient in 8–10 min), optional air counter-pressure module, drain valve for condensate removal, casters with brakes |
| Brand | Yuyi Instrument (Gongyi Yuyi) |
|---|---|
| Origin | Henan, China |
| Model | DLSB(EX) |
| Temperature Range | -20°C to -120°C |
| Reservoir Capacity | 10 L – 100 L |
| Power Supply | 220 V / 380 V, 50 Hz |
| Explosion Protection Rating | Ex d IIB T4 |
| Compliance | GB 3836.2–2000, Q/SHJFO2–2009 |
| Construction | Stainless Steel Fluid Circuit |
| Control | Digital PID Temperature Controller |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYD-5096A |
| Price | Upon Request |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±1 °C |
| Sample Capacity | 4–12 copper strips (4 test bomb positions, each accommodating 1 bomb or up to 3 glass tubes) |
| Display | LCD temperature controller with integrated timer and audible alarm |
| Reference Standard | GB/T 5096 |
| Calibration Reference | NIST-traceable ASTM D130-compliant copper strip color chart (imported from USA) |
| Brand | The Great Wall |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LT-50-80 |
| Cooling Capacity at −80 °C | 1000 W |
| Temperature Range | −80 °C to −40 °C |
| Temperature Stability | ±2 °C |
| Power Supply | 3~ 380 V, 50 Hz |
| Total Power Consumption | 9.8 kW |
| Refrigerant | R404A/R23 |
| Pump Flow Rate | 30 L/min |
| Max. Pressure | 1.0 bar |
| Reservoir Volume | 10 L |
| Dimensions (L×W×H) | ≈1200×710×1280 mm |
| Weight | 350 kg |
| Evaporator | Brazed Plate Heat Exchanger |
| Pump Type | Cryogenic-Optimized Magnetic Drive Circulating Pump |
| Construction | SUS304 Stainless Steel Reservoir & Tubing |
| Cabinet Material | SPCC Electrostatic Powder-Coated Steel |
| Cooling Method | Air-Cooled |
| Safety Protections | High/Low Pressure, Oil Pressure, Leakage, Overload, Overheat |
| Refrigerant Compliance | GB/T 7778–2008, EU F-Gas Regulation Compliant |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | MX-C |
| Temperature Range | 0–60 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 0–300 W |
| Sample Volume per Tube | 0.5–50 mL |
| Throughput | 8 samples (max. 2 mL/tube) |
| Vortex Motion | Orbital shaking with 4 mm orbit diameter |
| Speed Range | 0–3000 rpm (adjustable) |
| Power Input | 60 W |
| Voltage | 100–120 V / 200–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 127 × 130 × 160 mm |
| Weight | 2.0 kg |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Model | 531 |
| Compliance | NFX 15-211 (France), JG/T 385–2012 (China), SEFA 9 (USA), BS 7989 (UK) |
| Filtration Efficiency | <1% of OEL (Occupational Exposure Limit) / PC-TWA |
| Adjustable Shelf Height | Two Configurations — 10 cm clearance (e.g., 72 × 20 mL vials) or 20 cm clearance (e.g., 10 × 500 mL bottles) |
| Installation Type | Benchtop, modular mounting (above/below reagent shelving) |
| Power Supply | Standard 100–240 V AC, 50/60 Hz |
| Airflow | Continuous recirculating airflow with dual-stage molecular filtration |
| Filter Technology | Hybrid adsorption (physical + chemisorption) using activated carbon and impregnated media |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-950E |
| Temperature Range | 0–99°C |
| Operating Frequency | 20–25 kHz (auto-tracking & adaptive) |
| Ultrasonic Power Output | 5–950 W (adjustable) |
| Sample Volume Capacity | 100 µL – 600 mL (probe-dependent) |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3160 |
| Detection Principle | Catalytic Bead (Contact Combustion) |
| Detection Method | Pump-Aspirated |
| Measurable Gases | Combustible gases & vapors of combustible organic solvents (e.g., diesel, propane, methane, hexane) |
| Range | 0–5000 ppm or 0–1 vol% (auto-ranging) |
| Accuracy | ±5% FS (H-range), ±10% FS (L-range) |
| Alarm Thresholds | 250 ppm / 500 ppm (user-selectable) |
| Display | Backlit LCD with dual-mode output — numeric (0–5000 ppm / 0–1 vol%) and bar-graph scale (auto-switching between L-range: 0–500 ppm / 0–1000 ppm and H-range: 0–5000 ppm / 0–1 vol%) |
| Alarm Output | Audible buzzer + red LED flash (gas/fault) |
| Intrinsic Safety Rating | Ex ib d IIB T3 (combined intrinsic safety + flameproof enclosure) |
| Operating Temperature | −20 °C to +50 °C |
| Power Supply | Four AA alkaline batteries or optional Ni–Cd rechargeable pack |
| Battery Life | ~20 h (alkaline, no alarm/backlight), ~5 h (Ni–Cd, no alarm/backlight) |
| Dimensions | 82 × 162 × 36 mm (W × H × D) |
| Weight | ~450 g (without batteries) |
| Data Logging | Internal memory (standard) |
| Flow Anomaly Self-Check | Yes |
| Accessories Included | Leather carrying case, 4 × AA alkaline batteries, 1 m sampling hose, filter cartridge, filter disc, stainless steel probe tube, rubber suction tip |
| Optional Accessories | Extended sampling hose, gas mixer, data download kit (CD-ROM + USB cable), Ni–Cd battery pack, charger |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 190-P1-CFR |
| Absolute Pressure Range | 1 mbar to 4 bar abs |
| Accuracy | ±20 mbar |
| Resolution | 1 mbar |
| Response Time (t₉₀) | 0.2 s |
| Memory Capacity | 60,000 measurements |
| Measurement Interval | 1 s – 24 h |
| Operating Temperature | 0 – 140 °C |
| Storage Temperature | −20 – +50 °C |
| Housing Material | Stainless steel body with PEEK battery cap |
| Ingress Protection | IP68 |
| Battery | 1/2 AA lithium |
| Battery Life | 2,500 operating hours (10 s cycle at +121 °C) |
| Dimensions | Ø22 × 83 mm |
| Channel Count | 1 |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-100 |
| Housing Material | Monolithic ABS engineering plastic |
| Sample Capacity | ≤5 g (solid) or ≤15 mL (liquid) per run |
| Distillation Time | 3–8 min/sample |
| Nitrogen Measurement Range | 0.1–240 mg N |
| Alkali Addition Time | 0–99 s |
| Distillation Duration Setting | 0–99 min |
| Distillate Flow Rate | 14–28 mL/min |
| Heating Power Adjustment | 750–1500 W |
| Data Storage | 10 programmable distillation/alkali-addition protocols |
| Recovery Rate | >99.5% |
| Repeatability | RSD ≤0.5% |
| Safety Features | Real-time liquid-level monitoring, dry-run protection, overpressure relief, emergency stop |
| Compliance | Designed for ISO 8968, AOAC 981.10, and ASTM D1122-compliant workflows |
| Brand | Kylin-Bell |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TS-2 |
| Instrument Category | Orbital Shaker (Non-Incubated) |
| Oscillation Frequency Range | 30–240 rpm |
| Orbital Diameter | 30 mm (15 mm radius) |
| Platform Quantity | 1 |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power | 30 W |
| Speed Control | Continuous digital adjustment with LED display |
| Platform Dimensions | 280 × 260 mm |
| External Dimensions | 350 × 260 × 150 mm |
| Construction | Reinforced engineering plastic housing, brushless DC motor, nylon 1010 shaft core, brass eccentric bushing, molded natural rubber platform |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | TSF-50A-1 |
| Weighing Range | 0–50 g |
| Readability | 1 mg |
| Moisture Resolution | 0.01% |
| Display | 4.3-inch capacitive touchscreen LCD |
| Heating Source | Halogen lamp (adjustable power output) |
| Drying Modes | Standard & Rapid |
| Interface | USB Type-B (for printer, PC, and data export) |
| Compliance | GB/T 29249–2012 (Electronic Moisture Analyzer Based on Gravimetric Drying Method) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1914 |
| Measurement Principle | Pt1000 Resistance Thermometry |
| Temperature Range | –50 to +140 °C |
| Accuracy | ±0.2 °C (–50 to –40 °C), ±0.1 °C (–40 to +140 °C) |
| Resolution | 0.01 °C |
| Response Time t₉₀ | 6 s |
| Probe Length | 775 mm |
| Probe Diameter | 1.5 mm |
| Housing Diameter × Height | 20 × 72 mm |
| IP Rating | IP68 |
| Battery | 1/2 AA lithium |
| Operating Life | 2,500 h (10 s measurement interval at +121 °C) |
| Memory Capacity | 30,000 readings per channel |
| Enclosure Material | Stainless steel housing with PEEK-coated battery cap |
| Compliance | CE-marked, designed for HACCP-critical thermal validation |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MB90 |
| Price | USD 2,950 (approx.) |
| Maximum Capacity | 90 g |
| Readability | 1 mg / 0.01% |
| Temperature Range | 40–200 °C |
| Heating Source | Halogen |
| Display | 4.3" Color Touchscreen |
| Method Storage | 100 methods |
| Result Storage | 1000 records |
| User Management | 3-Level Access Control |
| Interface | RS232, USB |
| Shut-off Modes | Manual, Timed, Auto (A30/A60/A90), Custom |
| Heating Modes | Standard, Rapid |
| Chamber Cleaning | Tool-free disassembly |
| Construction | Die-cast aluminum base |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ZYD-DGY-100 |
| Pricing | Upon Request |
| Brand | Kylin-Bell |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | KB-1 |
| Instrument Type | Decolorization & Transfer Shaker |
| Oscillation Frequency | 40–240 rpm (adjustable, continuous) |
| Temperature Compatibility | Non-thermostatic — designed for use inside external incubators, cold rooms, or environmental chambers |
| Number of Platforms | 1 |
| Power Supply | 110–220 V AC (default 220 V) |
| Drive Mechanism | DC motor with nylon 1010 shaft core and brass eccentric sleeve |
| Transmission | Silicone timing belt |
| Platform Material | Molded natural rubber (acid/alkali resistant) |
| Platform Dimensions | 265 × 330 mm |
| Overall Dimensions (W×D×H) | 330 × 330 × 135 mm |
| Weight | 5 kg |
| Rated Power | 30 W |
| Motion Type | Horizontal orbital shaking |
| Speed Control | Stepless (analog knob) |