- All
- Favorite
- Popular
- Most rated
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA100 |
| Heating Method | Infrared (with optional halogen and quartz heating elements) |
| Readability | 0.1 mg |
| Certification | EC Type Approval for heating unit and weighing system |
| Drive Mechanism | Motor-driven integrated heating unit |
| Optional | Built-in thermal printer |
| Cleaning Design | Plug & Dry™ removable heating module |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA160-1CN |
| Heating Method | Infrared |
| Application Category | Laboratory & QC Moisture Analysis |
| Compliance Context | Designed for GLP/GMP environments, supports 21 CFR Part 11–compliant data integrity workflows (when integrated with optional software) |
| Method Storage Capacity | Up to 100 user-defined methods |
| Method Development Time | ≤45 minutes per new method (3-step guided workflow) |
| Cleaning Design | Removable heating module and sample chamber base plate, dishwasher-safe |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-5 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–50 g |
| Readability | 5 mg |
| Temperature Range | 50–160 °C |
| Heating Time | 1–99 min (1-min increments) |
| Sample Capacity | 0.5–10 g (recommended: 3–10 g) |
| Repeatability (3 g sample) | ±0.3% |
| Display | Backlit dot-matrix LCD |
| Interface | RS232 |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| End-point Modes | Timed & Automatic |
| Heating Profile | Standard |
| Display Outputs | Moisture %, Solid %, Sample Weight, Elapsed Time |
| Brand | Deleite |
|---|---|
| Origin | Shanghai, China |
| Model | HE100-1 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–100 g |
| Readability | 1 mg |
| Repeatability | ±0.30% (with 3 g sample) |
| Temperature Range | 40–180 °C |
| Heating Time | 1–99 min (1 min increments) |
| Sample Pan Diameter | 100 mm |
| Communication Interface | RS232 |
| Displayed Parameters | % Moisture, % Solids, Time, Temperature, Weight, Date |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-10A |
| Heating Method | Halogen Lamp |
| Display | High-Resolution Backlit Dot-Matrix LCD |
| Interface | RS-232C |
| Features | Automatic Tare, Zero Drift Compensation, Real-Time Dryness Monitoring |
| Compliance | Designed for ISO 5725 (accuracy & reproducibility), ASTM E1447 (moisture in solids), and USP <921> (Loss on Drying) |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DMS-4KEA |
| Price | USD 2,150 (FOB Shanghai) |
| Heating Method | Halogen Lamp |
| Weighing Range | 0–110 g |
| Weighing Accuracy | ±0.001 g |
| Moisture Determination Range | 0.001–100% |
| Temperature Control Range | 40–200 °C |
| Typical Measurement Time | ≤8 min |
| Display | 7-inch capacitive touchscreen |
| Language Support | English & Chinese |
| Built-in Functions | Auto-tare, one-touch preheat, temperature calibration, label printing, silent cooling fan, dual-drive automatic door opening |
| Optional Connectivity | Bluetooth 5.0 & Wi-Fi 802.11 b/g/n |
| User Management | Administrator & operator accounts with password protection |
| Internal Calibration | Scheduled interval setting with audit trail |
| Compliance | ASTM D4052, ISO 1183, USP <921>, GB/T 29246–2012 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | TSF-50A-5 |
| Heating Source | Halogen Lamp |
| Display | 4.3-inch Capacitive Touchscreen LCD |
| Readability | 0.01% / 1 mg |
| Compliance | GB/T 29249–2012 (Electronic Moisture Analyzer Based on Drying Method) |
| Interface | RS232 for Printer & PC Connectivity |
| Data Output | Real-time Drying Curve, Auto-finalization, Lock-on-Completion |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-1 |
| Heating Source | Halogen Lamp |
| Readability | 1 mg |
| Weighing Range | 0–50 g |
| Repeatability (3 g sample) | ±0.2% |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| Endpoint Modes | Timed & Automatic |
| Display | Moisture %, Solid %, Weight, Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Interface | RS232 |
| Brand | D&T |
|---|---|
| Origin | Tianjin, China |
| Model | EX-FH104A |
| Heating Source | Halogen Lamp |
| Weighing Range | 120 g |
| Readability | 0.1 mg |
| Repeatability (2 g sample) | 0.05% SD, ±0.1% |
| Repeatability (10 g sample) | 0.01% SD, ±0.05% |
| Moisture Readability | 0.001% MC |
| Calibration | Fully Automatic Internal Calibration |
| Drying Temperature Range | Single-Glass Mode: 40–160 °C |
| Dual-Glass Mode | 40–200 °C |
| Increment | 1 °C |
| Pan Diameter | Φ90 mm |
| Dimensions (W × D × H) | 200 × 385 × 120 mm |
| Moisture Range | 0.01–100% MC |
| Method Storage | 300 methods |
| Result Storage | 3000 records |
| Heating Programs | Standard, Stepwise, Rapid |
| Drying Termination Modes | Timed, Auto (5 preset weight-loss thresholds + user-defined threshold) |
| Warm-up Time | 20–30 min |
| Display Modes | %MC, %DC, g |
| Output Interfaces | RS232/RS485, LAN, USB1 (data export/firmware update), USB2 (dedicated printer) |
| Touchscreen | 7-inch capacitive |
| Sensor Type | Integrated electromagnetic force compensation sensor |
| Design | Separated weighing and display units |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB120 |
| Heating Method | Halogen Lamp |
| Capacity | 120 g |
| Readability | 0.01% / 0.001 g |
| Repeatability | 0.05% (3 g sample) / 0.015% (10 g sample) |
| Moisture Range | 0.01–100% (Moisture), 0.01–1000% (Regain) |
| Temperature Range | 40–230 °C |
| Display | 4.3″ QVGA TFT Color Touchscreen |
| Sample Pan Diameter | 90 mm |
| Dimensions (W×H×D) | 211 × 180 × 355 mm |
| Net Weight | 5.23 kg |
| Power Supply | 240 VAC, 50/60 Hz |
| Interface | RS232 (2 ports), USB Host (2 ports), USB Device |
| Operating Environment | 10–40 °C |
| Brand | Sartorius |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MA37-1CN |
| Price | USD 2,950 (approx.) |
| Heating Method | Infrared Metal Heater |
| Maximum Sample Capacity | 70 g |
| Readability | 1 mg / 0.01% |
| Voltage | 115 V / 230 V AC |
| Moisture Range | 0.01–99.99% |
| Programmable Methods | Yes |
| Compliance | Designed for GLP/GMP environments with audit-ready operation log |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-100A-1 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–100 g |
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.3% |
| Recommended Sample Mass | 3–10 g |
| Minimum Sample Mass | 0.5 g |
| Heating Time Setting | 1–99 min (1 min increments) |
| Temperature Range | 50–160 °C |
| End Point Control | Timer-based or Auto-termination |
| Display | Backlit dot-matrix LCD showing moisture %, solids %, weight, elapsed time |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-1 Halogen Moisture Analyzer |
| Heating Source | Halogen Lamp |
| Readability | 1 mg |
| Weighing Range | 0–50 g |
| Repeatability (3 g sample) | ±0.2% |
| Recommended Sample Mass | 3–10 g |
| Heating Time | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| End Point Modes | Timed & Automatic |
| Display | Moisture %, Solid %, Weight (g), Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication | RS232 |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB27ZH |
| Heating Method | Halogen Lamp |
| Capacity | 90 g |
| Readability | 1 mg / 0.01% |
| Pan Diameter | 90 mm |
| Part Number | 30128007 |
| Dimensions (W×D×H) | 17 × 14 × 28 cm |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA37 |
| Heating Method | Infrared |
| Weighing Capacity | 70 g |
| Heating Source | Metal Heater |
| Power Consumption | 640 VA |
| Line Voltage | 115 V / 230 V |
| Line Frequency | 50 / 60 Hz |
| Hood | Removable with Wide Opening Angle & SoftClose Mechanism |
| Weighing Accuracy | > 1 g: ±0.2 % |
| > 5 g | ±0.05 % |
| Recommended Moisture Range | 1–100 % |
Show next