Add to compare
BrandYDWG
OriginShanghai, China
ModelWGZ-1000B
TypePortable
Measurement Range0.000–20.00 NTU
Resolution0.001 NTU
Operating Temperature5–40 °C
Accuracy≤ ±2%
Light SourceLED infrared
Detection PrincipleRatio-based scattered-transmitted light measurement
ComplianceISO 7027, HJ 1075–2019, GLP
Data Storage2000 records
Power Supply4 × AA alkaline batteries or 5 V USB
DisplayBacklit LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelWGZ-200B
TypePortable
Measurement Range0.000–20.00 NTU
Resolution0.01 NTU
Operating Temperature5–40 °C
Accuracy≤ ±3%
Power Supply4×AA alkaline batteries or 5 V USB power
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelWGZ-200
TypePortable
Measurement Range0.000–20.00 NTU
Resolution0.01 NTU
Operating Temperature5–40 °C
Accuracy≤ ±3%
ComplianceISO 7027, HJ 1075–2019, Chinese Pharmacopoeia General Chapter 0902 (Method II)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSanxin Peirui
OriginShanghai, China
ModelTN450
Product TypePortable
Measurement Range0–1000 NTU (FNU), auto-ranging across three sub-ranges: 0.01–19.99 NTU (FNU), 20.0–99.9 NTU (FNU), and 100–1000 NTU (FNU)
Resolution0.01 / 0.1 / 1 NTU (FNU)
Operating Temperature0–50 °C
Accuracy≤ ±6%
ComplianceISO 7027, HJ 1075–2019, DIN 27027
IP RatingIP67
Data Storage200 GLP-compliant records
InterfaceUSB
DisplayTFT color screen with multilingual UI (English, Chinese, Spanish)
Power4 × AA batteries
Dimensions (instrument)90 × 203 × 80 mm
Weight (instrument)385 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOHAUS
OriginShanghai, China
Product TypePortable
ModelAP30
Measurement Range0–1000 NTU
ComplianceISO 7027
Detection PrincipleDual-optical-path nephelometry with integrated transmission compensation
Light SourceNear-infrared LED (850 nm)
DisplayFull-color high-brightness LCD
Data StorageUp to 5,000 measurements with timestamp
InterfaceUSB Type-A for data export
Power SupplyRechargeable Li-ion battery (≥10 hours continuous operation)
Enclosure RatingIP67 dust- and water-resistant housing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelWZB-172E
TypePortable
Measurement Range0.00–9.99 NTU
Resolution0.01 NTU
Operating Temperature5–40 °C
Accuracy±6%
Light SourceTungsten Lamp
Measurement PrincipleNephelometric (90° scattered light) and Ratio Nephelometric (scattered + transmitted light)
ComplianceHJ 1075–2019, USEPA Method 180.1, JJG 880–2006
IP RatingIP65
Data Storage1000 datasets
InterfaceMicro-USB, RS-232
PowerRechargeable Li-ion battery with PC/mobile power bank charging capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandINESA (YDWG)
OriginShanghai, China
ModelWGZ-4000
TypePortable
Measurement Range0.000–20.00 NTU
Resolution0.001 NTU
Operating Temperature5–40 °C
Accuracy≤ ±2%
ComplianceISO 7027, HJ 1075–2019, Chinese Pharmacopoeia General Chapter 0902 (Method II)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
Model600120
Instrument TypeBenchtop Laboratory Turbidimeter
Measurement Range0–1100 FNU/NTU
Resolution0.01 FNU/NTU (0.00–9.99), 0.1 FNU/NTU (10–99.99), 1 FNU/NTU (100–1100)
Operating Temperature+5 to +55 °C (41–131 °F)
Accuracy±0.01 FNU/NTU or ±2% of reading (±3% at 500–1100 FNU/NTU)
Compliance StandardDIN EN ISO 7027-1
Light SourceInfrared LED
Detection Angle90° Nephelometric Scattering
DisplayBacklit Graphic LCD (160 × 104 pixels)
Data Storage2500 datasets with calibration protocols and AQA flags
InterfaceUSB, RS-232, optional printer
GLP SupportFull audit trail, user ID, sample ID, calibration interval tracking, electronic signatures via Turb Data software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
Model750
Instrument TypeBenchtop Laboratory Turbidimeter
Measurement Range0–1100 FNU/NTU
Resolution0.01 FNU/NTU (0.00–9.99), 0.1 FNU/NTU (10–99.99), 1 FNU/NTU (100–1100)
Operating Temperature+5 to +55 °C (41–131 °F)
Accuracy±0.01 FNU/NTU or ±2% of reading (±3% at 500–1100 NTU for Turb 750T)
Compliance StandardsDIN EN ISO 7027-1 (Turb 750IR), US EPA Method 180.1 (Turb 750T)
Data Storage2500 datasets with calibration protocols and AQA flags
InterfaceUSB, RS-232, printer port
GLP-Compliant SoftwareTurb Data PC software (CSV export, LIMS import, user authentication, audit trail)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelWGZ-2000B
TypePortable
Measurement Range0.000–20.00 NTU
Resolution0.001 NTU
Operating Temperature5–40 °C
Accuracy≤ ±2%
Power Supply4 × AA alkaline batteries or 5 V USB power
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Model2100Q
Product TypePortable
Measurement Range0–1000 NTU
Resolution0.01 NTU
Accuracy±2% of reading + stray light contribution
Stray Light< 0.02 NTU (FNU)
ComplianceEPA Method 180.1
Optical PrincipleRatio-based 90° scattered light detection with simultaneous transmission compensation
Ingress ProtectionIP67 (excluding sealed cover and battery compartment)
Data Storage500 measurement records with timestamp, operator ID, sample ID, calibration status, and error logs
Power Options4 × AA alkaline batteries, rechargeable NiMH batteries (with USB+Power Module), or AC adapter (100–240 V, 50/60 Hz)
InterfaceUSB (supports 22 languages including English)
Measurement ModesNormal, Signal Average, Rapid Settling Turbidity (RST)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSANXIN
OriginShanghai, China
ModelTN150
TypePortable
Measurement Range0–1000 NTU (FNU), auto-ranging across three sub-ranges: 0.01–19.99 NTU (FNU), 20.0–99.9 NTU (FNU), 100–1000 NTU (FNU)
Resolution0.01 / 0.1 / 1 NTU (FNU)
Operating Temperature0–50 °C
Accuracy≤ ±8%
IP RatingIP67
DisplayTFT color screen
Light SourceTungsten filament lamp (400–600 nm)
Detection Principle90° nephelometric scattering
ComplianceHJ 1075–2019, EPA Method 180.1, ASTM D6508, ISO 7027–1:2016 (white light mode)
Calibration StandardsCertified polymer standards (0, 20, 100, 400, 800 NTU/FNU), EPA- and ASTM-compliant, 1-year shelf life
BatteryRechargeable 3.7 V Li-ion (7 V system equivalent), >20 h continuous operation
Dimensions (instrument)90 × 203 × 80 mm
Weight (instrument)385 g
CertificationsISO 9001:2015, CE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelWZS-182E
PriceUSD 980 (FOB Shanghai)
Form FactorBenchtop / Laboratory
Measurement Range0.00–9.99 NTU
Resolution0.01 / 0.1 / 1 NTU (auto-ranging)
Operating Temperature5–35 °C
Accuracy±6% of reading
Light SourceTungsten-halogen lamp
Measurement PrincipleNephelometric (90° scatter) and Ratio nephelometric-scatter/transmission
ComplianceUSEPA Method 180.1, HJ 1075–2019, JJG 880–2006
Display5.7-inch color LCD with tactile keypad
Protection RatingIP54
Calibration Standards IncludedLong-life turbidity standards at 20, 200, and 500 NTU
Data Storage1000 measurement records
InterfaceRS-232 (for thermal printer), USB-B (for PC communication)
Software SupportDedicated Leici turbidity data management software (Windows-compatible)
GLP FeaturesAudit-trail enabled timestamped records, user ID logging, calibration history, factory reset with zero & calibration value recovery
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginUSA
Model1720E
Instrument TypeBenchtop Laboratory Turbidimeter
Measurement Range0.0001–9.9999 NTU and 10.000–99.999 NTU (auto-ranging)
Resolution0.0001 NTU (0–9.9999 NTU)
Accuracy±2% or ±0.02 NTU (whichever is greater) for 0–40 NTU
RepeatabilityBetter than ±1.0% of reading or ±0.002 NTU (whichever is greater)
Response TimeStep response, initial response ~75 seconds
Signal Averaging Options6, 30, 60, or 90 seconds (user-selectable
Sample Flow Rate200–750 mL/min
Operating Temperature0–50°C (single-sensor configuration)
Sample Temperature Range0–50°C
Analog Output0/4–20 mA (programmable over 0–100 NTU range)
Relay OutputsThree SPDT relays (230 VAC, 5 A), configurable for alarm or control setpoints
Power Supply100–230 VAC, 50/60 Hz (auto-sensing)
Inlet Fitting1/4" NPT female + 1/4" compression fitting (included)
Drain Fitting1/2" NPT female + 1/2" hose barb (included)
Digital Communication ProtocolsMODBUS RTU over RS-485 and RS-232
Compliance StandardsStandard Method 2130B, USEPA Method 180.1, Hach Method 8195
Enclosure RatingNEMA-4X / IP66
Dimensions (Controller)25.4 × 30.5 × 40.6 cm
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0