BrandHach
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China-manufactured under Hach licensing)
ModelBODTrak II
Instrument TypeLaboratory BOD Analyzer
Measurement PrinciplePressure Differential Method
Measurement Ranges0–35, 0–70, 0–350, 0–700 mg/L
Detection Limit1 mg/L
Accuracy±1 mg/L
Incubation Duration5–10 days (user-selectable)
Incubation Temperature20 °C ±0.5 °C
Repeatability3–5% RSD
Sample ThroughputUp to 6 samples simultaneously
Data Logging IntervalEvery 15 minutes
Total Data Points Storage480
Software InterfaceHachLink™ PC software (Windows-compatible)
ComplianceDesigned to meet ASTM D5210, ISO 5815-1, and EPA Method 405.1 requirements for BOD₅ determination
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelBODTrak II
Instrument TypeLaboratory BOD Analyzer
Measurement PrincipleManometric (Pressure-Difference) Method
Measurement Ranges0–35, 0–70, 0–350, 0–700 mg/L O₂
Detection Limit0.01 mg/L O₂
Accuracy±2% at 235 mg/L BOD
Repeatability±2% at 235 mg/L BOD
Incubation Temperature20 °C (±0.5 °C)
Sample Throughput6 samples per run (473 mL bottles)
Data Storage480 data points per sample
DisplayReal-time graphical trace with cursor readout
Power SupplyAC adapter
Dimensions28.9 × 26.0 × 9.8 cm
Weight3.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelOxiTop-i IS6
Instrument TypeLaboratory BOD Analyzer
Measurement PrinciplePressure Difference Method (Mercury-Free Pressure Sensor)
Measurement Range0–4000 mg/L
Detection Limit≤1 mg/L
Accuracy±10% (relative to certified reference standards)
Measurement Duration2–28 days (user-definable incubation period)
Incubation Temperature20 °C default, adjustable from 15–30 °C
Repeatability≤5% RSD
Channel Capacity6 independent measurement channels per unit
ComplianceCE, EMC Directive 2014/30/EU
Power SupplyIncluded
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelinoLab Oxi 7310
Instrument TypeLaboratory BOD Analyzer
Measurement PrincipleElectrochemical Dissolved Oxygen (DO) Method with StirrOx-G Self-Stirring Sensor
Measurement RangeDO: 0.00–20.00 mg/L (resolution: 0.01/0.1 mg/L)
Saturation0–200.0 % (0.01/0.1 %)
Partial Pressure of O₂0–200.0 mbar (0.01/0.1 mbar)
Accuracy±0.5% of reading for DO, saturation, and pO₂
Data Storage5,000 automatic / 500 manual entries
InterfaceMini-USB
DisplayBacklit LCD with graphical capability
Power Supply4 × 1.5 V alkaline batteries, USB power, or universal AC adapter
Battery Lifeup to 800 h (no backlight), 100 h (continuous backlight)
ComplianceGLP/AQA-compliant data logging with audit trail support