Empowering Scientific Discovery

Yuanheng International Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
ModelH500
Instrument TypeIntegrated Circulating Chiller
Cooling MethodWater-Cooled
Temperature Stability±0.2 °C
Design ArchitectureSeparated Refrigeration and Heat Dissipation Units
Low-Temperature Operation CapabilityFunctional at outdoor ambient temperatures down to −25 °C
Control InterfaceFull-Color Touchscreen with Real-Time Multi-Parameter Display
Safety System13 Diagnostic Alarm Codes
Operational Flexibility12 Configurable System Parameter Sets
Hot Gas Bypass TechnologyIntegrated
PID Digital Temperature ControlStandard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIENTZ
OriginZhejiang, China
ModelDLK-2003
Instrument TypeIntegrated Circulating Chiller
Cooling MethodWater-Cooled
Temperature Range−20 °C to +45 °C
Temperature Stability±2 °C
Refrigeration Capacity782 W (at 25 °C ambient)
Circulation Pump Flow Rate20 L/min
Maximum Pump Pressure1.2 bar
Display Resolution0.1 °C
Reservoir Volume3 L
Noise Level≤57 dB(A)
Power Consumption0.55 kW
Dimensions (L×W×H)390×423×445 mm
Weight29 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
ModelH35
Instrument TypeIntegrated Circulating Chiller
Cooling MethodWater-Cooled
Temperature Range−5 to 35 °C
Cooling Capacity350 W (at 20 °C ambient) / 500 W (at 25 °C ambient)
Temperature Stability±0.3 °C
Circulation Pump Pressure1.0 bar
Circulation Flow Rate3.5 L/min
Reservoir Volume1.8 L
Operation ModeContinuous
Control TechnologyPID Digital Temperature Control + Hot Gas Bypass Compressor Modulation
Heat ExchangerPlate-Type
RefrigerantR134a (CFC-free, ozone-friendly)
DisplayBacklit LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYing’an Meicheng
OriginBeijing, China
ModelMC-1000C/BP
Instrument TypeIntegrated Circulating Chiller
Cooling MethodWater-Cooled
Temperature Control Range5–35 °C
Circulating Pump Pressure7 bar
Circulating Pump Flow Rate6 L/min
Reservoir Capacity15 L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandScientz
OriginZhejiang, China
ModelDLK-5001
Instrument TypeIntegrated Circulating Chiller
Cooling MethodAir-Cooled
Temperature Range–10 °C to 25 °C
Refrigeration Capacity1000 W at 20 °C
Temperature Stability±0.5 °C
Circulation Pump Pressure0.04 MPa
Circulation Flow Rate15 L/min
Reservoir Volume15 L
Operating ModeContinuous Duty
Display Resolution0.1 °C
Max. Flow Rate20 L/min
Max. Pump Pressure1.2 bar
Noise Level≤55 dB(A)
Power Input0.2 kW
Dimensions (L×W×H)260×340×300 mm
Weight18 kg
Power Supply220 V / 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandScientz
OriginZhejiang, China
ModelSLC-2030
Instrument TypeIntegrated Circulating Chiller
Cooling MethodAir-Cooled
Temperature Control Range–25 to +45 °C
Temperature Stability±0.1 °C
Refrigeration Capacity3.0 kW (at 25 °C ambient)
Circulating Pump Pressure0–6 bar (adjustable)
Max. Flow Rate30 L/min
Reservoir Volume8–15 L (usable), 18 L (total)
Total Power Consumption1.6 kW
Dimensions (L×W×H)428 × 620 × 890 mm
ConstructionStainless Steel Evaporator Tank, Corrosion-Resistant Tubing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Instrument TypeIntegrated Circulating Chiller
Cooling MethodWater-Cooled
Temperature Control Range–40 °C to +100 °C
Temperature Stability±0.05 °C (at setpoint, under stabilized conditions)
Bath MaterialSeamless 304 Stainless Steel
InterfaceRS485 for Remote Monitoring and Control
Safety FeaturesDual High/Low Temperature Alarm, Low-Level Liquid Alarm
Circulation ModeSwitchable Internal/External Loop via Manual Knob
Power Supply220–240 VAC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
ModelSMART Series
Instrument TypeIntegrated Circulating Chiller
Cooling MethodAir-Cooled
Temperature Range8–35 °C (Low-Temperature Models: −20 to 35 °C)
Refrigeration Capacity1000 W (@25 °C ambient)
Temperature Stability±0.1 °C
Circulation Pump Pressure3 bar (43.5 psi)
Flow Rate6.4 L/min
Reservoir Volume~5 L
Operating ModeContinuous Duty (Hot Gas Bypass Control)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandScientz
OriginShanghai, China
ModelDLK-5003
Cooling TypeWater-cooled
Temperature Range−5 °C to 45 °C
Refrigeration Capacity0.76 kW at 45 °C
Pump Pressure1.2 bar
Flow Rate20 L/min
Reservoir Volume3 L
Temperature Stability±2 °C
Display Resolution0.1 °C
Power Input0.55 kW
Voltage/Frequency220 V / 50 Hz
Noise Level≤57 dB(A)
Dimensions (W×L×H)390 × 423 × 445 mm
Weight29 kg
Connection PortG1/2″ internal thread
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0